45 resultados para Phosphorus Extraction
em Université de Lausanne, Switzerland
Resumo:
ABSTRACT : During my SNSF-funded Ph.D. thesis project, I studied the evolution of redox conditions and organic-carbon preservation in the western Tethyan realm during three major positive excursions in the Cretaceous δ13C record, corresponding to the Valanginian, Early Aptian and Late Cenomanian. These periods were characterized by important global environmental and climate change, which was associated with perturbations in the carbon cycle. For the period of the Valanginian δ13C excursion, total organic carbon (TOC) contents and the quality of preserved organic matter are typical of oxic pelagic settings in the western Tethys. This is confirmed by the absence of major excursions in the stratigraphic distribution of RSTE during the δ13C shift. Published TOC data from other parts of the Valanginian oceans indicate that dys- to anaerobic zones were restricted to marginal seas within the Atlantic and Southern Ocean, and to the Pacific. Phosphorus (P) and mineralogical contents suggest a stepwise climatic evolution during the Valanginian, with a humid and warm climate prior to the δ13C shift leading to an increase in continental runoff. During the δ13C shift, a decrease in detrital input and P contents suggests a change in the climate towards more and conditions. During the early Aptian oceanic anoxic event (OAE 1a), a general increase followed by a rapid decrease in P contents suggests enhanced nutrient input at the beginning of OAE 1a. The return to lower values during OAE 1 a, associated with an increase in RSTE contents, may have been related to the weakened capacity to retain P in the sedimentary reservoir due to bottom-water oxygen depletion. In basinal settings, the RSTE distribution indicates well-developed anoxic conditions during OAE la, whereas in the shallower-water environments, conditions were oxic to suboxic, rather than anoxic. Furthermore, in the deeper part of the Tethys, two distinct enrichments have been observed, indicating fluctuations in the intensity of water column anoxia during the δ73C excursion. We also studied the effect of the end-Cenomanian oceanic anoxic event (OAE 2) on an expanded section in the Chrummflueschlucht (E of Euthal, Ct Switzerland). The goal here was to identify paleoceanographic and paleoenvironmental conditions during OAE 2 in this part of the northern Tethyan margin. The results show that this section is one of the most complete sections for the Cenomanian-Turonian boundary interval known from the Helvetic realm, despite a small hiatus between sediments corresponding to peaks 1 and 2 in the δ13C record. The evolution of P contents points to an increase in the input of this nutrient at the onset of OAE 2. The trends in RSTE contents show, however, that this part of the Helvetic realm was not affected by a strong depletion in oxygen conditions during OAE 2, despite its hemipelagic position. A further goal of this project was to submit the samples to a total extraction method (a combined HF/HNO3/HCI acid digestion) and compare the results obtained by the partial HNO3 acid extraction in order to standardize the analytical prócedures in the extraction of RSTE. The obtained results for samples of OAE 1 a suggest that RSTE trends using the partial HNO3 digestion are very comparable to those obtained by the total digestion method and subsequently normalized with regards to AI contents. RÉSUMÉ : Durant ce projet de thèse, financé par le Swiss National Science Funding (SNSF), j'ai étudié l'évolution des conditions redox et de la préservation de carbone organique dans le domnaine ouesttéthysien pendant trois excursions majeures du δ13C au Crétacé correspondant au Valanginien, à l'Aptien inférieur et à la limite Cénomanien-Turonien. Ces périodes sont caractérisées par des changements climatiques et environnementaux globaux associés à des perturbations dans le cylce du carbone. Pour L'excursion positive en δ13C du Valanginien, les analyses du carbone organique total (COT) et les observations palynologiques du domaine téthysien ont présenté des indications d'environnement pélagique relativementbienoxygéné. L'absence d'enrichissements en éléments traces sensibles aux conditions redox (TE) pendant l'excursion positive en δ13C confirme ces interprétations. Les données publiées de COT dans d'autres partie du globe indiquent cependant l'existence de conditions dys- à anaérobiques dans certains bassins restreints de l'Atlantique, l'Océan Austral et du Pacifique. L'évolution du phosphore (P) et la composition minéralogique des sédiments semblent indiquer un climat relativement chaud et humide avant l'excursion en δ13C entraînant une augmentation de l'altération continentale. Pendant le shift isotopique, une diminution des apports détritiques et du P suggèrent une transition vers des conditions plus arides. À l'Aptien Inférieur, le début de l'événement anoxique (OAE 1a) est marqué par une augmentation générale du P dans les sédiments indiquant une augmentation du niveau trophique à la base de l'excursion isotopique. Durant l'événement anoxique, les sédiments sont relativement appauvris en P. Cette diminution rapide associée à des enrichissements en TE est probablement liée à une remobilisation plus importante du P lors de la mise en place de conditions anoxiques dans les eaux de fond. Dans les environnements de bassin, le comportement des TE (enrichissements bien marqués) attestent de conditions réductrices bien marquées alors que dans les environnements moins profonds, les conditions semblent plutôt oxiques à dysoxiques. De plus, deux niveaux d'enrichissement en TE ont été observés dans la partie plus profonde de la Téthys, indiquant des fluctuations assez rapides dans l'intensité de l'anoxie de la colonne d'eau. Nous avons ensuite étudié les effets de l'événement anoxique de la fin du Cenomanien (OAE 2) dans un basin marginal de la marge nord de la Téthys avec la coupe de Chrummflueschlucht (à l'est de Euthal, Ct Schwyz). Les résultats ont montré que cette coupe présente un des enregistrements sédimentaires des plus complets de l'OAE 2 dans le domaine helvétique malgré un hiatus entre le pic 1 et 2 de l'excursion en δ13C. L'évolution du P montre une augmentation au début de l'OAE 2. Cependant, la distribution des TE indique que cette région n'a pas été affectée par des conditions réductrices trop importantes. Un second aspect de ce travail a été l'étude des différentes méthodes sur l'analyse de la distribution des TE. Des échantillons de l'OAE 1a ont été soumis à deux types d'extractions, l'une dite «totale » (attaque combinée d'acides HF/HNO3/HCI) et l'autre dite partielle » (HNO3). Les résultats obtenus suggèrent que les courbes de tendances des TE acquises par extraction partielle sont semblables à celle obtenues par extraction totale et normalisées par l'AI.
Resumo:
We present a new method for lysis of single cells in continuous flow, where cells are sequentially trapped, lysed and released in an automatic process. Using optimized frequencies, dielectrophoretic trapping allows exposing cells in a reproducible way to high electrical fields for long durations, thereby giving good control on the lysis parameters. In situ evaluation of cytosol extraction on single cells has been studied for Chinese hamster ovary (CHO) cells through out-diffusion of fluorescent molecules for different voltage amplitudes. A diffusion model is proposed to correlate this out-diffusion to the total area of the created pores, which is dependent on the potential drop across the cell membrane and enables evaluation of the total pore area in the membrane. The dielectrophoretic trapping is no longer effective after lysis because of the reduced conductivity inside the cells, leading to cell release. The trapping time is linked to the time required for cytosol extraction and can thus provide additional validation of the effective cytosol extraction for non-fluorescent cells. Furthermore, the application of one single voltage for both trapping and lysis provides a fully automatic process including cell trapping, lysis, and release, allowing operating the device in continuous flow without human intervention.
Resumo:
Estimating the time since the last discharge of firearms and/or spent cartridges may be a useful piece of information in forensic firearm-related cases. The current approach consists of studying the diffusion of selected volatile organic compounds (such as naphthalene) released during the shooting using solid phase micro-extraction (SPME). However, this technique works poorly on handgun car-tridges because the extracted quantities quickly fall below the limit of detection. In order to find more effective solutions and further investigate the aging of organic gunshot residue after the discharge of handgun cartridges, an extensive study was carried out in this work using a novel approach based on high capacity headspace sorptive extraction (HSSE). By adopting this technique, for the first time 51 gunshot residue (GSR) volatile organic compounds could be simultaneously detected from fired handgun cartridge cases. Application to aged specimens showed that many of those compounds presented significant and complementary aging profiles. Compound-to-compound ratios were also tested and proved to be beneficial both in reducing the variability of the aging curves and in enlarging the time window useful in a forensic casework perspective. The obtained results were thus particularly promising for the development of a new complete forensic dating methodology.
Resumo:
Retained T-tubes are rare complications after biliary surgery. The authors present three cases of retained T-tubes in patients with transplanted liver that could not be removed by a standard manual traction. The authors describe a new simple percutaneous method that allows removal of these T-tubes without complication.
Resumo:
In this study we evaluate the dynamics of the biophile element phosphorus (P) in the catchment and proglacial areas of the Rhone and Oberaar glaciers (central Switzerland). We analysed erosion and dissolution rates of P-containing minerals in the subglacial environment by sampling water and suspended sediment in glacier outlets during three ablation and two accumulation seasons. We also quantified biogeochemical weathering rates of detrital P in proglacial sedimentary deposits using two chronosequences of samples of fresh, suspended, material obtained from the Oberaar and Rhone water outlets, Little-Ice-Age (LIA) moraines and Younger Dryas (YD) tills in each catchment. Subglacial P weathering is mainly a physical process and detrital P represents more than 99%, of the precipitation-corrected total P denudation flux (234 and 540 kg km(-2) yr(-1) for the Rhone and Oberaar catchments, respectively). The calculated detrital P flux rates are three to almost five times higher than the world average flux. The precipitation-corrected soluble reactive P (SRP) flux corresponds to 1.88-1.99 kg km(-2) yr(-1) (Rhone) and 2.12-2.44 kg km(-2) yr(-1) (Oberaar), respectively. These fluxes are comparable to those of tropical rivers draining transport-limited, tectonically inactive weathering areas. In order to evaluate the efficiency of detrital P weathering in the Rhone and Oberaar proglacial areas, we systematically graded apatite grains extracted from the chronosequence in each catchment relative to weathering-induced changes in their surface morphologies (grades 1-4). Fresh apatite grains are heavily indented and dissolution rounded (grade 1). LIA grains from two 0-10 cm deep moraine samples show extensive dissolution etching, similar to surface grains from the YD profile (mean grades 2.7, 3.5 and 3.5, respectively). In these proglacial deposits, the weathering front deepens progressively as a function of time due to biocorrosion in the evolving acidic pedosphere, with mechanical indentations on grains acting as sites of preferential dissolution. We also measured iron-bound, organic and detrital P concentrations in the chronosequence and show that organic and iron-bound P has almost completely replaced detrital P in the top layers of the YD profiles. Detrital P weathering rates are calculated as 3 10 and 280 kg km(-2) yr(-1) for LIA moraines and 10 kg km(-2) yr(-1) for YD tills. During the first 300 years of glacial sediment exposure P dissolution rates are shown to be approximately 70 times higher than the mean global dissolved P flux from ice-free continents. After 11.6 kyr the flux is 2.5 times the global mean. These data strengthen the argument for substantial changes in the global dissolved P flux on glacial-interglacial timescales. A crude extrapolation from the data described here suggests that the global dissolved P flux may increase by 40-45% during the first few hundred years of a deglaciation phase
Resumo:
Solid-phase extraction (SPE) in tandem with dispersive liquid-liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography-flame ionization (GC-FID) detection system. In the hyphenated SPE-DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500-mg octadecyl silane (C(18) ) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5-500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85-118%.
Resumo:
ABSTRACT: In sexual assault cases, autosomal DNA analysis of gynecological swabs is a challenge, as the presence of a large quantity of female material may prevent the detection of the male DNA. A solution to this problem is differential DNA extraction, but as there are different protocols, it was decided to test their efficiency on simulated casework samples. Four difficult samples were sent to the nine Swiss laboratories active in the forensic genetics. They used their routine protocols to separate the epithelial cell fraction, enriched with the non-sperm DNA, from the sperm fraction. DNA extracts were then sent to the organizing laboratory for analysis. Estimates of male to female DNA ratio without differential DNA extraction ranged from 1:38 to 1:339, depending on the semen used to prepare the samples. After differential DNA extraction, most of the ratios ranged from 1:12 to 9:1, allowing the detection of the male DNA. Compared to direct DNA extraction, cell separation resulted in losses of 94-98% of the male DNA. As expected, more male DNA was generally present in the sperm than in the epithelial cell fraction. However, for about 30% of the samples, the reverse trend was observed. The recovery of male and female DNA was highly variable depending on the laboratories. Experimental design similar to the one used in this study may help for local protocol testing and improvement.
Resumo:
In most pathology laboratories worldwide, formalin-fixed paraffin embedded (FFPE) samples are the only tissue specimens available for routine diagnostics. Although commercial kits for diagnostic molecular pathology testing are becoming available, most of the current diagnostic tests are laboratory-based assays. Thus, there is a need for standardized procedures in molecular pathology, starting from the extraction of nucleic acids. To evaluate the current methods for extracting nucleic acids from FFPE tissues, 13 European laboratories, participating to the European FP6 program IMPACTS (www.impactsnetwork.eu), isolated nucleic acids from four diagnostic FFPE tissues using their routine methods, followed by quality assessment. The DNA-extraction protocols ranged from homemade protocols to commercial kits. Except for one homemade protocol, the majority gave comparable results in terms of the quality of the extracted DNA measured by the ability to amplify differently sized control gene fragments by PCR. For array-applications or tests that require an accurately determined DNA-input, we recommend using silica based adsorption columns for DNA recovery. For RNA extractions, the best results were obtained using chromatography column based commercial kits, which resulted in the highest quantity and best assayable RNA. Quality testing using RT-PCR gave successful amplification of 200 bp-250 bp PCR products from most tested tissues. Modifications of the proteinase-K digestion time led to better results, even when commercial kits were applied. The results of the study emphasize the need for quality control of the nucleic acid extracts with standardised methods to prevent false negative results and to allow data comparison among different diagnostic laboratories.
Resumo:
The aim of this study was to evaluate the forensic protocol recently developed by Qiagen for the QIAsymphony automated DNA extraction platform. Samples containing low amounts of DNA were specifically considered, since they represent the majority of samples processed in our laboratory. The analysis of simulated blood and saliva traces showed that the highest DNA yields were obtained with the maximal elution volume available for the forensic protocol, that is 200 ml. Resulting DNA extracts were too diluted for successful DNA profiling and required a concentration. This additional step is time consuming and potentially increases inversion and contamination risks. The 200 ml DNA extracts were concentrated to 25 ml, and the DNA recovery estimated with real-time PCR as well as with the percentage of SGM Plus alleles detected. Results using our manual protocol, based on the QIAamp DNA mini kit, and the automated protocol were comparable. Further tests will be conducted to determine more precisely DNA recovery, contamination risk and PCR inhibitors removal, once a definitive procedure, allowing the concentration of DNA extracts from low yield samples, will be available for the QIAsymphony.
Resumo:
Objectifs: Exposer une nouvelle technique permettant le retrait de ciment extra-vertebral par fuite accidentelle lors du retrait du matériel. Matériels et méthodes: Nous injectons le ciment lorsque sa densité est celle d'une pâte dentifrice pour éviter les passages vasculaires. Lorsque la vertèbre est parfaitement remplie,nous patientons quelques minutes pour éviter la fuite de ciment le long du trajet (environ 4 a 6 cc en moyenne par vertèbre sont injectés). Malgré ces précautions,une fuite de ciment peut survenir lors du retrait du trocart. Cette complication est rare lorsque l'on prend les précautions nécessaires. Cependant, si la pressionintra-vertébrale est importante, le ciment peut être aspiré en dehors de la vertèbre. Résultats: L'aiguille du trocart est retirée pour être remplacée par une pince d'endoscopie 13 gauges. Sous guidage scopique, l'extraction se fait sous contrôle continu ; lapince retirant la fuite de ciment. Conclusion: La connaissance de cette intervention peut être très utile pour les équipes de radiologie interventionnelle , d'orthopédie et de neurochirurgie réalisant desvertébroplasties, pouvant être confrontées à ce type de problèmes.
Resumo:
The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.