7 resultados para Permian Coal Measures

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Mont Collon mafic complex is one of the best preserved examples of the Early Permian magmatism in the Central Alps, related to the intra-continental collapse of the Variscan belt. It mostly consists (> 95 vol.%) of ol+hy-nonnative plagioclase-wehrlites, olivine- and cpx-gabbros with cumulitic structures, crosscut by acid dikes. Pegmatitic gabbros, troctolites and anorthosites outcrop locally. A well-preserved cumulative, sequence is exposed in the Dents de Bertol area (center of intrusion). PT-calculations indicate that this layered magma chamber emplaced at mid-crustal levels at about 0.5 GPa and 1100 degrees C. The Mont Collon cumulitic rocks record little magmatic differentiation, as illustrated by the restricted range of clinopyroxene mg-number (Mg#(cpx)=83-89). Whole-rock incompatible trace-element contents (e.g. Nb, Zr, Ba) vary largely and without correlation with major-element composition. These features are characteristic of an in-situ crystallization process with variable amounts of interstitial liquid L trapped between the cumulus mineral phases. LA-ICPMS measurements show that trace-element distribution in the latter is homogeneous, pointing to subsolidus re-equilibration between crystals and interstitial melts. A quantitative modeling based on Langmuir's in-situ crystallization equation successfully duplicated the REE concentrations in cumulitic minerals of all rock facies of the intrusion. The calculated amounts of interstitial liquid L vary between 0 and 35% for degrees of differentiation F of 0 to 20%, relative to the least evolved facies of the intrusion. L values are well correlated with the modal proportions of interstitial amphibole and whole-rock incompatible trace-element concentrations (e.g. Zr, Nb) of the tested samples. However, the in-situ crystallization model reaches its limitations with rock containing high modal content of REE-bearing minerals (i.e. zircon), such as pegmatitic gabbros. Dikes of anorthositic composition, locally crosscutting the layered lithologies, evidence that the Mont Collon rocks evolved in open system with mixing of intercumulus liquids of different origins and possibly contrasting compositions. The proposed model is not able to resolve these complex open systems, but migrating liquids could be partly responsible for the observed dispersion of points in some correlation diagrams. Absence of significant differentiation with recurrent lithologies in the cumulitic pile of Dents de Bertol points to an efficiently convective magma chamber, with possible periodic replenishment, (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attrition in longitudinal studies can lead to biased results. The study is motivated by the unexpected observation that alcohol consumption decreased despite increased availability, which may be due to sample attrition of heavy drinkers. Several imputation methods have been proposed, but rarely compared in longitudinal studies of alcohol consumption. The imputation of consumption level measurements is computationally particularly challenging due to alcohol consumption being a semi-continuous variable (dichotomous drinking status and continuous volume among drinkers), and the non-normality of data in the continuous part. Data come from a longitudinal study in Denmark with four waves (2003-2006) and 1771 individuals at baseline. Five techniques for missing data are compared: Last value carried forward (LVCF) was used as a single, and Hotdeck, Heckman modelling, multivariate imputation by chained equations (MICE), and a Bayesian approach as multiple imputation methods. Predictive mean matching was used to account for non-normality, where instead of imputing regression estimates, "real" observed values from similar cases are imputed. Methods were also compared by means of a simulated dataset. The simulation showed that the Bayesian approach yielded the most unbiased estimates for imputation. The finding of no increase in consumption levels despite a higher availability remained unaltered. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary : 1. Measuring health literacy in Switzerland: a review of six surveys: 1.1 Comparison of questionnaires - 1.2 Measures of health literacy in Switzerland - 1.3 Discussion of Swiss data on HL - 1.4 Description of the six surveys: 1.4.1 Current health trends and health literacy in the Swiss population (gfs-UNIVOX), 1.4.2 Nutrition, physical exercise and body weight : opinions and perceptions of the Swiss population (USI), 1.4.3 Health Literacy in Switzerland (ISPMZ), 1.4.4 Swiss Health Survey (SHS), 1.4.5 Survey of Health, Ageing and Retirement in Europe (SHARE), 1.4.6 Adult literacy and life skills survey (ALL). - 2 . Economic costs of low health literacy in Switzerland: a rough calculation. Appendix: Screenshots cost model

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intensification of pharmacotherapy in persons with poorly controlled chronic conditions has been proposed as a clinically meaningful process measure of quality. OBJECTIVE: To validate measures of treatment intensification by evaluating their associations with subsequent control in hypertension, hyperlipidemia, and diabetes mellitus across 35 medical facility populations in Kaiser Permanente, Northern California. DESIGN: Hierarchical analyses of associations of improvements in facility-level treatment intensification rates from 2001 to 2003 with patient-level risk factor levels at the end of 2003. PATIENTS: Members (515,072 and 626,130; age >20 years) with hypertension, hyperlipidemia, and/or diabetes mellitus in 2001 and 2003, respectively. MEASUREMENTS: Treatment intensification for each risk factor defined as an increase in number of drug classes prescribed, of dosage for at least 1 drug, or switching to a drug from another class within 3 months of observed poor risk factor control. RESULTS: Facility-level improvements in treatment intensification rates between 2001 and 2003 were strongly associated with greater likelihood of being in control at the end of 2003 (P < or = 0.05 for each risk factor) after adjustment for patient- and facility-level covariates. Compared with facility rankings based solely on control, addition of percentages of poorly controlled patients who received treatment intensification changed 2003 rankings substantially: 14%, 51%, and 29% of the facilities changed ranks by 5 or more positions for hypertension, hyperlipidemia, and diabetes, respectively. CONCLUSIONS: Treatment intensification is tightly linked to improved control. Thus, it deserves consideration as a process measure for motivating quality improvement and possibly for measuring clinical performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.