142 resultados para Pelvic Floor Ultrasound
em Université de Lausanne, Switzerland
Resumo:
Pelvic floor anatomy is complex and its three-dimensional organization is often difficult to understand for both undergrad- uate and postgraduate students. Here, we focused on several critical points that need to be considered when teaching the perineum. We have to deal with a mixed population of students and with a variety of interest. Yet, a perfect knowledge of the pelvic floor is the basis for any gynecologist and for any surgical intervention. Our objectives are several-fold; i) to estab- lish the objectives and the best way of teaching, ii) to identify and localize areas in the female pelvic floor that are suscepti- ble to generate problems in understanding the three-dimensional organization, iii) to create novel approaches by respecting the anatomical surroundings, and iv) prospectively, to identify elements that may create problems during surgery i.e. to have a closer look at nerve trajectories and on compression sites that may cause neuralgia or postoperative pain. A feedback from students concludes that they have difficulties to assimilate this much information, especially the different imaging tech- niques. Eventually, this will lead to a severe selection of what has to be taught and included in lectures or practicals. Another consequence is that more time to study prosected pelves needs to be given.
Resumo:
INTRODUCTION AND HYPOTHESIS: This study aims to estimate fecal, urinary incontinence, and sexual function 6 years after an obstetrical anal sphincter tear. METHODS: Among 13,213 women who had a vaginal delivery of a cephalic singleton at term, 196 women sustained an anal sphincter tear. They were matched to 588 controls. Validated questionnaires grading fecal and urinary incontinence, and sexual dysfunction were completed by the participants. RESULTS: Severe fecal incontinence was more frequently reported by women who had sustained an anal sphincter tear compared to the controls. Women with an anal sphincter tear had no increased risk of urinary incontinence, but reported significantly more pain, difficulty with vaginal lubrication, and difficulty achieving orgasm compared to the controls. A fetal occiput posterior position during childbirth was an independent risk factor for both severe urinary incontinence and severe sexual dysfunction. CONCLUSIONS: Fecal incontinence is strongly associated with an anal sphincter tear. A fetal occiput posterior position represents a risk factor for urinary incontinence and sexual dysfunction.
Resumo:
Patients referred for chronic constipation frequently report symptoms of straining, feeling of incomplete evacuation, or the need to facilitate defecation digitally (dyschezia). When such patients show manometric evidence of inappropriate contraction or failure to relax the pelvic floor muscles during attempts to defecate, they are diagnosed as having pelvic floor dyssynergia (Rome I). To evaluate long-term satisfaction of patients with pelvic floor dyssynergia after biofeedback. Forty-one consecutive patients referred for chronic constipation at an outpatient gastrointestinal unit and diagnosed as having pelvic floor dyssynergia who completed a full course of biofeedback. Data have been collected using a standardised questionnaire. A questionnaire survey of patients' satisfaction rate and requirement of aperients was undertaken. Mean age and symptom duration were respectively 41 and 20 years. Half of patients reported fewer than 3 bowel motions per week. Patients were treated with a mean of 5 biofeedback sessions. At the end of the therapy pelvic floor dyssynergia was alleviated in 85% of patients and 49% were able to stop all aperients. Satisfaction was maintained at follow-up telephone interviews undertaken after a mean period of 2 years, as biofeedback was helpful for 79% of patients and 47% still abstained from intake of aperients. Satisfaction after biofeedback is high for patients referred for chronic constipation and diagnosed with pelvic floor dyssynergia. Biofeedback improves symptoms related to dyschezia and reduces use of aperients.
Resumo:
Vaginal delivery can cause lesions of the various pelvic structures responsible for the mechanisms of continence. These lesions may perhaps be prevented in the future by measuring pressure generated during childbirth. Tear of the anal sphincter during childbirth is a marker of a global impairment of the urinary, ano-rectal and sexual pelvic functions in the short and medium term. Persistence of a defect of the anal sphincter is frequent in spite of immediate suture. The correlation between these defects and ano-rectal incontinence are not established in our experience. The quality of the contraction of the sphincter complex and pubo-rectal sling seems to play a more important role in ano-rectal continence after a traumatic childbirth.
Resumo:
Abstract: The aim of the study was to assess the effects of epidural analgesia on pelvic floor function. Eighty- two primiparous women (group 1, consisting of 41 given an epidural, and group 2 of 41 not given an epidural) were investigated during pregnancy and at 2 and 10 months after delivery by a questionnaire, clinical examination, and assessment of bladder neck behavior, urethral sphincter function and intravaginal/intra-anal pressures. The prevalence of stress urinary incontinence was similar in both groups at 2 months (24% vs. 17%, P = 0.6) and 10 months (22% vs. 7%, P = 0.1), as was the prevalence of decreased sexual vaginal response at 10 months (27% vs. 10%, P= 0.08). Bladder neck behavior, urethral sphincter function and intravaginal and intra-anal pressures showed no significant differences between the two groups. Ten months after spontaneous delivery, there were no significant differences in the prevalence of stress urinary incontinence and decreased sexual vaginal response, or in bladder neck behavior, urethral sphincter function and pelvic floor muscle strength between women who had or had not had epidural analgesia.
Resumo:
BACKGROUND: Abdominoperineal resection (APR) following radiotherapy is associated with a high rate of perineal wound complications. The anterolateral thigh (ALT) flap, combined with the vastus lateralis (VL) muscle, can cover complex perineal and pelvic anteroposterior defects. This is used for the first time transabdominally through the pelvis and the perineum (TAPP) in the infero-posterior directions; this technique has been described and illustrated in this study. METHODS: Among over 90 patients who underwent perineal reconstruction between May 2004 and June 2011, six patients presented high-grade tumours invading perineum, pelvis and sacrum, thereby resulting in a continuous anteroposterior defect. ALT + VL TAPP reconstructions were performed after extended APR and, subsequently, sacrectomy. Patients were examined retrospectively to determine demographics, operative time, complications (general and flap-related), time to complete healing and length of hospital stay. Long-term flap coverage, flap volume stability and functional and aesthetic outcomes were assessed. RESULTS: Mean operating time of the reconstruction was 290 min. No deaths occurred. One patient presented partial flap necrosis. Another patient presented a novel wound dehiscence after flap healing, due to secondary skin dissemination of the primary tumour. Following volumetric flap analysis on serial post-operative CT scans, no significant flap atrophy was observed. All flaps fully covered the defects. No late complications such as fistulas or perineal hernias occurred. Donor-site recovery was uneventful with no functional deficits. CONCLUSIONS: The use of the ALT + VL flap transabdominally is an innovative method to reconstruct exceptionally complex perineal and pelvic defects extending up to the lower back. This flap guarantees superior bulk, obliterating all pelvic dead space, with the fascia lata (FL) supporting the pelvic floor.
Resumo:
Purpose: Dynamic high-field magnetic resonance (MR) defecography including the evacuation phase is a promising tool for the assessment of functional pelvic disorders, nowadays seen with increasing frequency in elderly women in particular. Learning objectives: 1. To describe the adequate technique of dynamic high-field MRI (3T) in assessing pelvic floor disorders. 2. To provide an overview of the most common pathologies occurring during the evacuation phase, especially in comparison with results of conventional defecography. Methods and materials: After description of the ideal technical parameters of MR defecography performed in supine position after gel rectal filling with a 3 Tesla unit and including the evacuation phase we stress the importance of using a standardized evaluation system for the exact assessment of pelvic floor pathophysiology. Results: The typical pelvic floor disorders occurring before and/or during the evacuation phase, such as sphincter insufficiency, vaginal vault and/or uterine prolapse, cystourethrocele, peritoneo-/ entero-/ sigmoïdocele or rectal prolapse, are demonstrated. The difference between the terms "pelvic floor descent" and "pelvic floor relaxation" are pictorially outlined. MR results are compared with these of conventional defecography. Conclusion: Exact knowledge about the correct technique including the evacuation phase and the use of a standardized evaluation system in assessing pelvic floor disorders by dynamic high-field MRI is mandatory for accurate and reproducible diagnosis.
Resumo:
Overactive bladder (OAB) is a prevalent condition with 16% of adults having one or more symptoms that significantly affect quality of life. Transcutaneous electrical nerve stimulation and neuromodulators have had success in treating OAB but are expensive, invasive, and sometimes cumbersome. We developed an alternative neuromodulatory technique that involves electromagnetic stimulation of the sacral nerve roots with a portable electromagnetic device to produce trans-sacral stimulation of the S3 and S4 sacral nerve roots. The aim of this study was to evaluate the impact of this device on OAB symptoms in women with a prospectively randomised double-blind controlled study. Following a power analysis, women with symptoms of OAB were prospectively recruited with ethical approval for randomisation to an active treatment (n = 33) or placebo group (n = 30) in a double-blind trial. The patient, at home, used the belt device daily for 20 min over 12 weeks. Outcome measures included a 3-day voiding diary, 1 h pad test, visual analogue score (VAS) for symptom impact (0-100%), Kings Health Questionnaire (KHQ) and Australian Quality of Life questionnaire (AQOL) at baseline, 6 and 12 weeks. Overall, no difference was found between groups for any of the research questions. Specifically, we were unable to demonstrate any difference between the active and sham device groups in frequency, nocturia, urinary leakage, or quality of life, nor was there any evidence of a placebo effect. The quality of the data was high with the number of missing observations (especially for disease specific KHQ and general AQOL) being few. This attempt to promote trans-sacral electromagnetic neuromodulation with a specially created device was ineffective on the symptoms of OAB.
Resumo:
INTRODUCTION AND HYPOTHESIS: The objective of this study is to assess anatomical and functional results of the extraperitoneal uterosacral ligament suspension (USL) in women with post-hysterectomy vaginal vault prolapse. METHODS: One hundred and twenty-three consecutive women were included. Concurrent procedures were anterior colporraphy with fascial repair (20%) and mesh reinforcement (49%), posterior colporraphy with fascial repair (38%) and mesh reinforcement (56%) and a sling procedure (29%). Women were assessed using Baden and Walker and pelvic organ prolapse quantification classification pre- and post-operatively. RESULTS: One hundred and ten patients (89%) were available for follow-up. Mean follow-up was 2 years. Objective success rate regarding the vaginal cuff is 95.4%. Global anatomical success rate was 85.5%. Urinary, coital and bowel symptoms were improved following surgery. Mesh exposure rate was 19.3%, with all cases managed conservatively or with minor interventions. CONCLUSION: Bilateral extraperitoneal USL is an effective operation to restore apical support with low morbidity, which avoids potential risks associated with opening the peritoneal cavity.
Resumo:
Parameters of intrarectal pressure (surface area under pressure curve and peak pressure) recorded with a microsystem device during the second phase of labor showed no significant correlations with baby's weight or mode of delivery. AIM OF THE STUDY: Was to assess the biomechanical pressures delivered against pelvic floor structures during the second phase of labor in nulliparae women, and to correlate them with obstetrics parameters, i.e. baby'sweight and mode of delivery. MATERIAL: Using a microsystem device placed into the rectum at the beginning of the second phase of labor, two parameters were assessed during the bearing efforts in 59 nulliparae women: the surface area under the pressure curve and the peak pressure. RESULTS: During 11.5±9 bearing efforts of 99.1±16s duration, the mean value of surface area under the pressure curve was 32677±26058cm/s and the mean value of the peak pressure was 60.7±24cmH(2)O, exceeding 100cmH(2)O in 10% of women. These two parameters were not correlated with baby's weight (R: 0.19, P: 0.15 and R: 0.05, P: 0.71). In the same way, these two parameters were not correlated with the mode of delivery (spontaneous or forceps/vacuum-assisted). Furthermore, the individual values of these two parameters showed great variation from one woman to another. CONCLUSION: This study has showed that parameters of biomechanical pressures recorded into the rectum during second phase of labor had no significant correlations with obstetricals parameters, explaining why these latter have poor predicitive value of further pelvic floor problems.
Resumo:
OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.
Resumo:
PURPOSE: To evaluate a diagnostic strategy for pulmonary embolism that combined clinical assessment, plasma D-dimer measurement, lower limb venous ultrasonography, and helical computed tomography (CT). METHODS: A cohort of 965 consecutive patients presenting to the emergency departments of three general and teaching hospitals with clinically suspected pulmonary embolism underwent sequential noninvasive testing. Clinical probability was assessed by a prediction rule combined with implicit judgment. All patients were followed for 3 months. RESULTS: A normal D-dimer level (<500 microg/L by a rapid enzyme-linked immunosorbent assay) ruled out venous thromboembolism in 280 patients (29%), and finding a deep vein thrombosis by ultrasonography established the diagnosis in 92 patients (9.5%). Helical CT was required in only 593 patients (61%) and showed pulmonary embolism in 124 patients (12.8%). Pulmonary embolism was considered ruled out in the 450 patients (46.6%) with a negative ultrasound and CT scan and a low-to-intermediate clinical probability. The 8 patients with a negative ultrasound and CT scan despite a high clinical probability proceeded to pulmonary angiography (positive: 2; negative: 6). Helical CT was inconclusive in 11 patients (pulmonary embolism: 4; no pulmonary embolism: 7). The overall prevalence of pulmonary embolism was 23%. Patients classified as not having pulmonary embolism were not anticoagulated during follow-up and had a 3-month thromboembolic risk of 1.0% (95% confidence interval: 0.5% to 2.1%). CONCLUSION: A noninvasive diagnostic strategy combining clinical assessment, D-dimer measurement, ultrasonography, and helical CT yielded a diagnosis in 99% of outpatients suspected of pulmonary embolism, and appeared to be safe, provided that CT was combined with ultrasonography to rule out the disease.
Resumo:
Purpose: The purpose of this study was to compare the plaque morphology between coronary and peripheral arteries using intravascular ultrasound (IVUS). Methods: IVUS was performed in 68 patients with coronary and 93 with peripheral artery lesions (29 carotid, 50 renal, and 14 iliac). Plaques were classified as fibroatheroma (VH-FA) (further subclassified as thin-capped [VH-TCFA] and thick-capped [VH-ThCFA]), fibrocalcific plaque (VH-FC) and pathological intimal thickening (VH-PIT). Results: Plaque rupture (13% of coronary, 7% of carotid, 6% of renal, and 7% of iliac arteries; P=NS) and VH-TCFA (37% of coronary, 24% of carotid, 16% of renal, and 7% of iliac arteries; P=0.02) was observed in all arteries. Compared to coronary arteries, VH-FA was less frequently observed in renal (P<0.001) and iliac arteries (P<0.006), while VH-PIT and VH-FC were prevalent in both of these peripheral arteries. Lesions with positive remodeling demonstrated more characteristics of VH-FA in coronary, carotid, and renal arteries compared to those with intermediate/negative remodeling (all P<0.01). There was positive relationship between RI and percent necrotic core area in all four arteries. Conclusions: Atherosclerotic plaque phenotypes were heterogeneous among four different arteries. In contrast, the associations of remodeling mode with plaque phenotype and composition were similar among the various arterial beds.