115 resultados para Parallel hyperspectral unmixing method

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. METHODS: Quadratic phase is imparted to the image to spread the signals in k-space (aka phase scrambling). By rewriting the Fourier transform as a convolution operation, a window can be introduced to the convolved chirp function, allowing a low-resolution image to be reconstructed from phase-scrambled data without prominent aliasing. This image (for each RF channel) can be used to derive coil sensitivities to drive existing parallel imaging techniques. As a proof of concept, the quadratic phase was applied by introducing an offset to the x(2) - y(2) shim and the data were reconstructed using adapted versions of the image space-based sensitivity encoding and GeneRalized Autocalibrating Partially Parallel Acquisitions algorithms. RESULTS: The method is demonstrated in a phantom (1 × 2, 1 × 3, and 2 × 2 acceleration) and in vivo (2 × 2 acceleration) using a 3D gradient echo acquisition. CONCLUSION: Phase scrambling can be used to perform parallel imaging acceleration without acquisition of separate coil calibration data, demonstrated here for a 3D-Cartesian trajectory. Further research is required to prove the applicability to other 2D and 3D sampling schemes. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Ischemic stroke is the leading cause of mortality worldwide and a major contributor to neurological disability and dementia. Terutroban is a specific TP receptor antagonist with antithrombotic, antivasoconstrictive, and antiatherosclerotic properties, which may be of interest for the secondary prevention of ischemic stroke. This article describes the rationale and design of the Prevention of cerebrovascular and cardiovascular Events of ischemic origin with teRutroban in patients with a history oF ischemic strOke or tRansient ischeMic Attack (PERFORM) Study, which aims to demonstrate the superiority of the efficacy of terutroban versus aspirin in secondary prevention of cerebrovascular and cardiovascular events. METHODS AND RESULTS: The PERFORM Study is a multicenter, randomized, double-blind, parallel-group study being carried out in 802 centers in 46 countries. The study population includes patients aged > or =55 years, having suffered an ischemic stroke (< or =3 months) or a transient ischemic attack (< or =8 days). Participants are randomly allocated to terutroban (30 mg/day) or aspirin (100 mg/day). The primary efficacy endpoint is a composite of ischemic stroke (fatal or nonfatal), myocardial infarction (fatal or nonfatal), or other vascular death (excluding hemorrhagic death of any origin). Safety is being evaluated by assessing hemorrhagic events. Follow-up is expected to last for 2-4 years. Assuming a relative risk reduction of 13%, the expected number of primary events is 2,340. To obtain statistical power of 90%, this requires inclusion of at least 18,000 patients in this event-driven trial. The first patient was randomized in February 2006. CONCLUSIONS: The PERFORM Study will explore the benefits and safety of terutroban in secondary cardiovascular prevention after a cerebral ischemic event.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contemporary coronary magnetic resonance angiography techniques suffer from signal-to-noise ratio (SNR) constraints. We propose a method to enhance SNR in gradient echo coronary magnetic resonance angiography by using sensitivity encoding (SENSE). While the use of sensitivity encoding to improve SNR seems counterintuitive, it can be exploited by reducing the number of radiofrequency excitations during the acquisition window while lowering the signal readout bandwidth, therefore improving the radiofrequency receive to radiofrequency transmit duty cycle. Under certain conditions, this leads to improved SNR. The use of sensitivity encoding for improved SNR in three-dimensional coronary magnetic resonance angiography is investigated using numerical simulations and an in vitro and an in vivo study. A maximum 55% SNR enhancement for coronary magnetic resonance angiography was found both in vitro and in vivo, which is well consistent with the numerical simulations. This method is most suitable for spoiled gradient echo coronary magnetic resonance angiography in which a high temporal and spatial resolution is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Résumé : Cette thèse de doctorat est le fruit d'un projet de recherche européen financé par le quatrième programme cadre de la Commission Européenne (DG XII, Standards, Measurement and Testing). Ce projet, dénommé SMT-CT98-2277, a été financé pour la partie suisse par l'Office Fédéral de l'Education et de la Science (OFES, Berne, Suisse). Le but de ce projet était de développer une méthode harmonisée et collaborativement testée pour le profilage des impuretés de l'amphétamine illicite par chromatographie capillaire en phase gazeuse. Le travail a été divisé en sept phases majeures qui concernaient la synthèse de l'amphétamine, l'identification d'impuretés, l'optimisation de la préparation de l'échantillon et du système chromatographique, la variabilité des résultats, l'investigation de méthodes mathématiques pour la classification et la comparaison de profils et finalement l'application de la méthode à des réels échantillons illicites. La méthode résultant de ce travail n'a pas seulement montré que les données étaient interchangeables entre laboratoires mais aussi qu'elle était supérieure en de nombreux points aux méthodes préalablement publiées dans la littérature scientifique. Abstract : This Ph.D. thesis was carried out in parallel to an European project funded by the fourth framework program of the European Commission (DG XII, Standards, Measurement and Testing). This project, named SMT-CT98-2277 was funded, for the Swiss part, by the Federal Office of Education and Science (OFES, Bern, Switzerland). The aim of the project was to develop a harmonised, collaboratively tested method for the impurity profiling of illicit amphetamine by capillary gas chromatography. The work was divided into seven main tasks which deal with the synthesis of amphetamine, identification of impurities, optimization of sample preparation and of the chromatographic system, variability of the results, investigation of numerical methods for the classification and comparison of profiles and finally application of the methodology to real illicit samples. The resulting method has not only shown to produce interchangeable data between different laboratories but was also found to be superior in many aspects to previously published methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé : Les progrès techniques de la spectrométrie de masse (MS) ont contribué au récent développement de la protéomique. Cette technique peut actuellement détecter, identifier et quantifier des milliers de protéines. Toutefois, elle n'est pas encore assez puissante pour fournir une analyse complète des modifications du protéome corrélées à des phénomènes biologiques. Notre objectif était le développement d'une nouvelle stratégie pour la détection spécifique et la quantification des variations du protéome, basée sur la mesure de la synthèse des protéines plutôt que sur celle de la quantité de protéines totale. Pour cela, nous volions associer le marquage pulsé des protéines par des isotopes stables avec une méthode d'acquisition MS basée sur le balayage des ions précurseurs (precursor ion scan, ou PIS), afin de détecter spécifiquement les protéines ayant intégré les isotopes et d'estimer leur abondance par rapport aux protéines non marquées. Une telle approche peut identifier les protéines avec les plus hauts taux de synthèse dans une période de temps donnée, y compris les protéines dont l'expression augmente spécifiquement suite à un événement précis. Nous avons tout d'abord testé différents acides aminés marqués en combinaison avec des méthodes PIS spécifiques. Ces essais ont permis la détection spécifique des protéines marquées. Cependant, en raison des limitations instrumentales du spectromètre de masse utilisé pour les méthodes PIS, la sensibilité de cette approche s'est révélée être inférieure à une analyse non ciblée réalisée sur un instrument plus récent (Chapitre 2.1). Toutefois, pour l'analyse différentielle de deux milieux de culture conditionnés par des cellules cancéreuses humaines, nous avons utilisé le marquage métabolique pour distinguer les protéines d'origine cellulaire des protéines non marquées du sérum présentes dans les milieux de culture (Chapitre 2.2). Parallèlement, nous avons développé une nouvelle méthode de quantification nommée IBIS, qui utilise des paires d'isotopes stables d'acides aminés capables de produire des ions spécifiques qui peuvent être utilisés pour la quantification relative. La méthode IBIS a été appliquée à l'analyse de deux lignées cellulaires cancéreuses complètement marquées, mais de manière différenciée, par des paires d'acides aminés (Chapitre 2.3). Ensuite, conformément à l'objectif initial de cette thèse, nous avons utilisé une variante pulsée de l'IBIS pour détecter des modifications du protéome dans des cellules HeLa infectée par le virus humain Herpes Simplex-1 (Chapitre 2.4). Ce virus réprime la synthèse des protéines des cellules hôtes afin d'exploiter leur mécanisme de traduction pour la production massive de virions. Comme prévu, de hauts taux de synthèse ont été mesurés pour les protéines virales détectées, attestant de leur haut niveau d'expression. Nous avons de plus identifié un certain nombre de protéines humaines dont le rapport de synthèse et de dégradation (S/D) a été modifié par l'infection virale, ce qui peut donner des indications sur les stratégies utilisées par les virus pour détourner la machinerie cellulaire. En conclusion, nous avons montré dans ce travail que le marquage métabolique peut être employé de façon non conventionnelle pour étudier des dimensions peu explorées en protéomique. Summary : In recent years major technical advancements greatly supported the development of mass spectrometry (MS)-based proteomics. Currently, this technique can efficiently detect, identify and quantify thousands of proteins. However, it is not yet sufficiently powerful to provide a comprehensive analysis of the proteome changes correlated with biological phenomena. The aim of our project was the development of ~a new strategy for the specific detection and quantification of proteomé variations based on measurements of protein synthesis rather than total protein amounts. The rationale for this approach was that changes in protein synthesis more closely reflect dynamic cellular responses than changes in total protein concentrations. Our starting idea was to couple "pulsed" stable-isotope labeling of proteins with a specific MS acquisition method based on precursor ion scan (PIS), to specifically detect proteins that incorporated the label and to simultaneously estimate their abundance, relative to the unlabeled protein isoform. Such approach could highlight proteins with the highest synthesis rate in a given time frame, including proteins specifically up-regulated by a given biological stimulus. As a first step, we tested different isotope-labeled amino acids in combination with dedicated PIS methods and showed that this leads to specific detection of labeled proteins. Sensitivity, however, turned out to be lower than an untargeted analysis run on a more recent instrument, due to MS hardware limitations (Chapter 2.1). We next used metabolic labeling to distinguish the proteins of cellular origin from a high background of unlabeled (serum) proteins, for the differential analysis of two serum-containing culture media conditioned by labeled human cancer cells (Chapter 2.2). As a parallel project we developed a new quantification method (named ISIS), which uses pairs of stable-isotope labeled amino acids able to produce specific reporter ions, which can be used for relative quantification. The ISIS method was applied to the analysis of two fully, yet differentially labeled cancer cell lines, as described in Chapter 2.3. Next, in line with the original purpose of this thesis, we used a "pulsed" variant of ISIS to detect proteome changes in HeLa cells after the infection with human Herpes Simplex Virus-1 (Chapter 2.4). This virus is known to repress the synthesis of host cell proteins to exploit the translation machinery for the massive production of virions. As expected, high synthesis rates were measured for the detected viral proteins, confirming their up-regulation. Moreover, we identified a number of human proteins whose synthesis/degradation ratio (S/D) was affected by the viral infection and which could provide clues on the strategies used by the virus to hijack the cellular machinery. Overall, in this work, we showed that metabolic labeling can be employed in alternative ways to investigate poorly explored dimensions in proteomics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this retrospective study was to compare the clinical and radiographic results after TKA (PFC, DePuy), performed either by computer assisted navigation (CAS, Brainlab, Johnson&Johnson) or by conventional means. Material and methods: Between May and December 2006 we reviewed 36 conventional TKA performed between 2002 and 2003 (group A) and 37 navigated TKA performed between 2005 and 2006 (group B) by the same experienced surgeon. The mean age in group A was 74 years (range 62-90) and 73 (range 58-85) in group B with a similar age distribution. The preoperative mechanical axes in group A ranged from -13° varus to +13° valgus (mean absolute deviation 6.83°, SD 3.86), in group B from -13° to +16° (mean absolute deviation 5.35, SD 4.29). Patients with a previous tibial osteotomy or revision arthroplasty were excluded from the study. Examination was done by an experienced orthopedic resident independent of the surgeon. All patients had pre- and postoperative long standing radiographs. The IKSS and the WOMAC were utilized to determine the clinical outcome. Patient's degree of satisfaction was assessed on a visual analogous scale (VAS). Results: 32 of the 37 navigated TKAs (86,5%) showed a postoperative mechanical axis within the limits of 3 degrees of valgus or varus deviation compared to only 24 (66%) of the 36 standard TKAs. This difference was significant (p = 0.045). The mean absolute deviation from neutral axis was 3.00° (range -5° to +9°, SD: 1.75) in group A in comparison to 1.54° (range -5° to +4°, SD: 1.41) in group B with a highly significant difference (p = 0.000). Furthermore, both groups showed a significant postoperative improvement of their mean IKSS-values (group A: 89 preoperative to 169 postoperative, group B 88 to 176) without a significant difference between the two groups. Neither the WOMAC nor the patient's degree of satisfaction - as assessed by VAS - showed significant differences. Operation time was significantly higher in group B (mean 119.9 min.) than in group A (mean 99.6 min., p <0.000). Conclusion: Our study showed consistent significant improvement of postoperative frontal alignment in TKA by computer assisted navigation (CAS) compared to standard methods, even in the hands of a surgeon well experienced in standard TKA implantation. However, the follow-up time of this study was not long enough to judge differences in clinical outcome. Thus, the relevance of computer navigation for clinical outcome and survival of TKA remains to be proved in long term studies to justify the longer operation time. References 1 Stulberg SD. Clin Orth Rel Res. 2003;(416):177-84. 2 Chauhan SK. JBJS Br. 2004;86(3):372-7. 3 Bäthis H, et al. Orthopäde. 2006;35(10):1056-65.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used massively parallel signature sequencing (MPSS) to sample the transcriptomes of 32 normal human tissues to an unprecedented depth, thus documenting the patterns of expression of almost 20,000 genes with high sensitivity and specificity. The data confirm the widely held belief that differences in gene expression between cell and tissue types are largely determined by transcripts derived from a limited number of tissue-specific genes, rather than by combinations of more promiscuously expressed genes. Expression of a little more than half of all known human genes seems to account for both the common requirements and the specific functions of the tissues sampled. A classification of tissues based on patterns of gene expression largely reproduces classifications based on anatomical and biochemical properties. The unbiased sampling of the human transcriptome achieved by MPSS supports the idea that most human genes have been mapped, if not functionally characterized. This data set should prove useful for the identification of tissue-specific genes, for the study of global changes induced by pathological conditions, and for the definition of a minimal set of genes necessary for basic cell maintenance. The data are available on the Web at http://mpss.licr.org and http://sgb.lynxgen.com.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dispersal mechanisms and competition together play a key role in the spatial distribution of a population. Species that disperse via fission are likely to experience high levels of localized competitive pressure from conspecifics relative to species that disperse in other ways. Although fission dispersal occurs in many species, its ecological and behavioural effects remain unclear. We compared foraging effort, nest spatial distribution and aggression of two sympatric ant species that differ in reproductive dispersal: Streblognathus peetersi, which disperse by group fission, and Plectroctena mandibularis, which disperse by solitary wingless queens. We found that although both species share space and have similar foraging strategies, they differ in nest distribution and aggressive behaviour. The spatial distribution of S. peetersi nests was extremely aggregated, and workers were less aggressive towards conspecifics from nearby nests than towards distant conspecifics and all heterospecific workers. By contrast, the spatial distribution of P. mandibularis nests was overdispersed, and workers were equally aggressive towards conspecific and heterospecific competitors regardless of nest distance. Finally, laboratory experiments showed that familiarity led to the positive relationship between aggression and nest distance in S. peetersi. While unfamiliar individuals were initially aggressive, the level of aggression decreased within 1 h of contact, and continued to decrease over 24 h. Furthermore, individuals from near nests that were not aggressive could be induced to aggression after prolonged isolation. Overall, these results suggest that low aggression mediated by familiarity could provide benefits for a species with fission reproduction and an aggregated spatial distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clenbuterol is a β2 agonist agent with anabolic properties given by the increase in the muscular mass in parallel to the decrease of the body fat. For this reason, the use of clenbuterol is forbidden by the World Anti-Doping Agency (WADA) in the practice of sport. This compound is of particular interest for anti-doping authorities and WADA-accredited laboratories due to the recent reporting of risk of unintentional doping following the eating of meat contaminated with traces of clenbuterol in some countries. In this work, the development and the validation of an ultra-high pressure liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the quantification of clenbuterol in human urine is described. The analyte was extracted from urine samples by liquid-liquid extraction (LLE) in basic conditions using tert butyl-methyl ether (TBME) and analyzed by UHPLC-MS/MS with a linear gradient of acetonitrile in 9min only. The simple and rapid method presented here was validated in compliance with authority guidelines and showed a limit of quantification at 5pg/mL and a linearity range from 5pg/mL to 300pg/mL. Good trueness (85.8-105%), repeatability (5.7-10.6% RSD) and intermediate precision (5.9-14.9% RSD) results were obtained. The method was then applied to real samples from eighteen volunteers collecting urines after single oral doses administration (1, 5 and 10μg) of clenbuterol-enriched yogurts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a semisupervised support vector machine (SVM) that integrates the information of both labeled and unlabeled pixels efficiently. Method's performance is illustrated in the relevant problem of very high resolution image classification of urban areas. The SVM is trained with the linear combination of two kernels: a base kernel working only with labeled examples is deformed by a likelihood kernel encoding similarities between labeled and unlabeled examples. Results obtained on very high resolution (VHR) multispectral and hyperspectral images show the relevance of the method in the context of urban image classification. Also, its simplicity and the few parameters involved make the method versatile and workable by unexperienced users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Q-sort is a research method which allows defining profiles of attitudes toward a set of statements, ordered in relation to each other. Pertaining to the Q Methodology, the qualitative analysis of the Q-sorts is based on quantitative techniques. This method is of particular interest for research in health professions, a field in which attitudes of patients and professionals are very important. The method is presented in this article, along with an example of application in nursing in old age psychiatry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In contemporary society, religious signification and secular systems mix and influence each other. Holistic conceptions of a world in which man is integrated harmoniously with nature meet representations of a world run by an immanent God. On the market of the various systems, the individual goes from one system to another, following his immediate needs and expectations without necessarily leaving any marks in a meaningful long term system. This article presents the first results of an ongoing research in Switzerland on contemporary religion focusing on (new) paths of socialization of modern that individuals and the various (non-) belief systems that they simultaneously develop

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.