49 resultados para PRESSURE MEASUREMENTS

em Université de Lausanne, Switzerland


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Ubiquitylation plays an important role in the control of Na⁺ homeostasis by the kidney. It is well established that the epithelial Na⁺ channel ENaC is regulated by the ubiquitin-protein ligase NEDD4-2, limiting ENaC cell surface expression and activity. Ubiquitylation can be reversed by the action of deubiquitylating enzymes (DUBs). One such DUB, USP2-45, was identified previously as an aldosterone-induced protein in the kidney and is also a circadian output gene. In heterologous expression systems, USP2-45 binds to ENaC, deubiquitylates it, and enhances channel density and activity at the cell surface. Because the role of USP2-45 in renal Na⁺ transport had not been studied in vivo, we investigated here the effect of Usp2 gene inactivation in this process. We demonstrate first that USP2-45 protein has a rhythmic expression with a peak at ZT12. Usp2-KO mice did not show any differences from wild-type littermates with respect to the diurnal control of Na⁺ or K⁺ urinary excretion and plasma levels either on a standard diet or after acute and chronic changes to low- and high-Na⁺ diets, respectively. Moreover, they had similar aldosterone levels on either a low- or high-Na⁺ diet. Blood pressure measurements using telemetry did not reveal variations compared with control mice. Usp2-KO mice did not display alterations in expression of genes involved in sodium homeostasis or the ubiquitin system, as evidenced by transcriptome analysis in the kidney. Our data suggest that USP2 does not play a primary role in the control of Na⁺ balance or blood pressure.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

CONTEXT: Fatigue-induced alterations in foot mechanics may lead to structural overload and injury. OBJECTIVES: To investigate how a high-intensity running exercise to exhaustion modifies ankle plantar-flexor and dorsiflexor strength and fatigability, as well as plantar-pressure distribution in adolescent runners. DESIGN: Controlled laboratory study. SETTING: Academy research laboratory. PATIENTS OR OTHER PARTICIPANTS: Eleven male adolescent distance runners (age = 16.9 ± 2.0 years, height = 170.6 ± 10.9 cm, mass = 54.6 ± 8.6 kg) were tested. INTERVENTION(S): All participants performed an exhausting run on a treadmill. An isokinetic plantar-flexor and dorsiflexor maximal-strength test and a fatigue test were performed before and after the exhausting run. Plantar-pressure distribution was assessed at the beginning and end of the exhausting run. MAIN OUTCOME MEASURE(S): We recorded plantar-flexor and dorsiflexor peak torques and calculated the fatigue index. Plantar-pressure measurements were recorded 1 minute after the start of the run and before exhaustion. Plantar variables (ie, mean area, contact time, mean pressure, relative load) were determined for 9 selected regions. RESULTS: Isokinetic peak torques were similar before and after the run in both muscle groups, whereas the fatigue index increased in plantar flexion (28.1%; P = .01) but not in dorsiflexion. For the whole foot, mean pressure decreased from 1 minute to the end (-3.4%; P = .003); however, mean area (9.5%; P = .005) and relative load (7.2%; P = .009) increased under the medial midfoot, and contact time increased under the central forefoot (8.3%; P = .01) and the lesser toes (8.9%; P = .008). CONCLUSIONS: Fatigue resistance in the plantar flexors declined after a high-intensity running bout performed by adolescent male distance runners. This phenomenon was associated with increased loading under the medial arch in the fatigued state but without any excessive pronation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: We have sought to develop an automated methodology for the continuous updating of optimal cerebral perfusion pressure (CPPopt) for patients after severe traumatic head injury, using continuous monitoring of cerebrovascular pressure reactivity. We then validated the CPPopt algorithm by determining the association between outcome and the deviation of actual CPP from CPPopt. DESIGN: Retrospective analysis of prospectively collected data. SETTING: Neurosciences critical care unit of a university hospital. PATIENTS: A total of 327 traumatic head-injury patients admitted between 2003 and 2009 with continuous monitoring of arterial blood pressure and intracranial pressure. MEASUREMENTS AND MAIN RESULTS: Arterial blood pressure, intracranial pressure, and CPP were continuously recorded, and pressure reactivity index was calculated online. Outcome was assessed at 6 months. An automated curve fitting method was applied to determine CPP at the minimum value for pressure reactivity index (CPPopt). A time trend of CPPopt was created using a moving 4-hr window, updated every minute. Identification of CPPopt was, on average, feasible during 55% of the whole recording period. Patient outcome correlated with the continuously updated difference between median CPP and CPPopt (chi-square=45, p<.001; outcome dichotomized into fatal and nonfatal). Mortality was associated with relative "hypoperfusion" (CPP<CPPopt), severe disability with "hyperperfusion" (CPP>CPPopt), and favorable outcome was associated with smaller deviations of CPP from the individualized CPPopt. While deviations from global target CPP values of 60 mm Hg and 70 mm Hg were also related to outcome, these relationships were less robust. CONCLUSIONS: Real-time CPPopt could be identified during the recording time of majority of the patients. Patients with a median CPP close to CPPopt were more likely to have a favorable outcome than those in whom median CPP was widely different from CPPopt. Deviations from individualized CPPopt were more predictive of outcome than deviations from a common target CPP. CPP management to optimize cerebrovascular pressure reactivity should be the subject of future clinical trial in severe traumatic head-injury patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: Ankle arthrodesis (AD) and total ankle replacement (TAR) are typical treatments for ankle osteoarthritis (AO). Despite clinical interest, there is a lack of their outcome evaluation using objective criteria. Gait analysis and plantar pressure assessment are appropriate to detect pathologies in orthopaedics but they are mostly used in lab with few gait cycles. In this study, we propose an ambulatory device based on inertial and plantar pressure sensors to compare the gait during long-distance trials between healthy subjects (H) and patients with AO or treated by AD and TAR. Methods: Our study included four groups: 11 patients with AO, 9 treated by TAR, 7 treated by AD and 6 control subjects. An ambulatory system (Physilog®, CH) was used for gait analysis; plantar pressure measurements were done using a portable insole (Pedar®-X, DE). The subjects were asked to walk 50 meters in two trials. Mean value and coefficient of variation of spatio-temporal gait parameters were calculated for each trial. Pressure distribution was analyzed in ten subregions of foot. All parameters were compared among the four groups using multi-level model-based statistical analysis. Results: Significant difference (p <0.05) with control was noticed for AO patients in maximum force in medial hindfoot and forefoot and in central forefoot. These differences were no longer significant in TAR and AD groups. Cadence and speed of all pathologic groups showed significant difference with control. Both treatments showed a significant improvement in double support and stance. TAR decreased variability in speed, stride length and knee ROM. Conclusions: In spite of a small sample size, this study showed that ankle function after AO treatments can be evaluated objectively based on plantar pressure and spatio-temporal gait parameters measured during unconstrained walking outside the lab. The combination of these two ambulatory techniques provides a promising way to evaluate foot function in clinics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a review of different methods enabling the monitoring of cerebral function in neonatal and paediatric intensive care. EEG, evoked potentials, conventional radiological studies, computerized tomography, ultrasound, intracranial pressure measurements, nuclear magnetic resonance, Doppler ultrasound, radioisotope studies, angiography, infra-red spectral analysis and last, but not least, clinical examination produce information regarding the neurological state of the patient which must be critically analysed in order to ensure optimal management of the case. Unfortunately, and in spite of impressive progress in non-invasive monitoring of the cerebral function, we are still forced to make important medical and ethical decisions without precise information about the neurological state of our patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To characterize the pathogenesis and clinical features of optic disc edema associated with obstructive sleep apnea syndrome (SAS). METHODS: A series of 4 patients with SAS and papilledema (PE) underwent complete neuro-ophthalmologic evaluation and lumbar puncture. In 1 patient, continuous 24-hour intracranial pressure (ICP) monitoring was also performed. RESULTS: All 4 patients had bilateral PE that was asymmetric in 2. Three patients had optic nerve dysfunction, asymmetric in 1, unilateral in 2. Daytime cerebrospinal fluid pressure measurements were within normal range. Nocturnal monitoring performed in one patient, however, demonstrated repeated episodes of marked ICP elevation associated with apnea and arterial oxygen desaturation. CONCLUSIONS: We propose that PE in SAS is due to episodic nocturnal hypoxemia and hypercarbia resulting in increased ICP secondary to cerebral vasodilation. In these individuals, intermittent ICP elevation is sufficient to cause persistent disc edema. These patients may be at increased risk for developing visual loss secondary to PE compared with patients with obesity-related pseudotumor cerebri because of associated hypoxemia. The diagnosis of SAS PE may not be appreciated because daytime cerebrospinal fluid pressure measurements are normal and because patients tend to present with visual loss rather than with symptoms of increased ICP.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: There are no time trends in prevalence, unawareness, treatment, and control of hypertension in Switzerland. The objective of this study was to analyze these trends and to determine the associated factors. METHODS/FINDINGS: Population-based study conducted in the Canton of Geneva, Switzerland, between 1999 and 2009. Blood pressure was measured thrice using a standard protocol. Hypertension was defined as mean systolic or diastolic blood pressure ≥140/90 mmHg or self-reported hypertension or anti-hypertensive medication. Unawareness, untreated and uncontrolled hypertension was determined by questionnaires/blood pressure measurements. Yearly age-standardized prevalences and adjusted associations for the 1999-2003 and 2004-2009 survey periods were reported. The 10-year survey included 9,215 participants aged 35 to 74 years. Hypertension remained stable (34.4%). Hypertension unawareness decreased from 35.9% to 17.7% (P<0.001). The decrease in hypertension unawareness was not paralleled by a concomitant absolute increase in hypertension treatment, which remained low (38.2%). A larger proportion of all hypertensive participants were aware but not treated in 2004-2009 (43.7%) compared to 1999-2003 (33.1%). Uncontrolled hypertension improved from 62.2% to 40.6% between 1999 and 2009 (P = 0.02). In 1999-2003 period, factors associated with hypertension unawareness were current smoking (OR = 1.27, 95%CI, 1.02-1.59), male gender (OR = 1.56, 1.27-1.92), hypercholesterolemia (OR = 1.31, 1.20-1.44), and older age (OR 65-74yrs vs 35-49yrs  = 1.56, 1.21-2.02). In 1999-2003 and 2004-2009, obesity and diabetes were negatively associated with hypertension unawareness, high education was associated with untreated hypertension (OR = 1.45, 1.12-1.88 and 1.42, 1.02-1.99, respectively), and male gender with uncontrolled hypertension (OR = 1.49, 1.03-2.17 and 1.65, 1.08-2.50, respectively). Sedentarity was associated with higher risk of hypertension and uncontrolled hypertension in 1999-2003. CONCLUSIONS: Hypertension prevalence remained stable since 1999 in the canton of Geneva. Although hypertension unawareness substantially decreased, more than half of hypertensive subjects still remained untreated or uncontrolled in 2004-2009. This study identified determinants that should guide interventions aimed at improving hypertension treatment and control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To compare the prevalence and management of cardiovascular risk factors (CVRFs) between immigrant groups and Swiss nationals. METHODS: The Swiss Health Surveys (SHS, N = 49,245) and CoLaus study (N = 6,710) were used. Immigrant groups from France, Germany, Italy, Portugal, Spain, former Yugoslavia, other European and other countries were defined. RESULTS: Immigrants from Italy, France, Portugal, Spain and former Yugoslavia presented a higher prevalence of smoking than Swiss nationals. Immigrants reported less hypertension than Swiss nationals, but the differences were reduced when blood pressure measurements were used. The prevalence of dyslipidaemia was similar between immigrants and Swiss nationals in the SHS. When eligibility for statin treatment was assessed, immigrants from Italy were more frequently eligible than Swiss nationals. Immigrants from former Yugoslavia presented a lower prevalence of diabetes in the SHS, but a higher prevalence in the CoLaus study. Most differences between immigrant groups and Swiss nationals disappeared after adjusting for age, leisure-time physical activity, being overweight/obesity and education. CONCLUSIONS: Most CVRFs are unevenly distributed among immigrant groups in Switzerland, but these differences are due to disparities in age, leisure-time physical activity, being overweight/obesity and education.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS: For a collapsible caval model, a very flexible plastic material was selected, and a model with nine afferent veins was designed according to the anatomy of the vena cava. A flow bench was built including a lower reservoir holding the caval tree, built by taking into account the main afferent vessels and their flow provided by a reservoir 6 cm above. A cannula was inserted in this caval tree and connected to a centrifugal pump that, in turn, was connected to a reservoir positioned 83 cm above the second lower reservoir (after-load = 60 mmHg). Using the same pre-load, the simulated venous drainage for cardiopulmonary bypass was realized using a 24 F wall-less cannula (Smartcanula) and 25 F percutaneous cannula (Biomedicus), and stepwise increased augmentation (1500 RPM, 2000 and 2500 RPM) of venous drainage. RESULTS: For the thin wall and the wall-less cannulas, 36 pairs of flow and pressure measurements were realized for three different RPM values. The mean Q-values at 1500, 2000 and 2500 RPM were: 3.98 ± 0.01, 6.27 ± 0.02 and 9.81 ± 0.02 l/min for the wall-less cannula (P <0.0001), versus 2.74 ± 0.02, 3.06 ± 0.05, 6.78 ± 0.02 l/min for the thin-wall cannula (P <0.0001). The corresponding inlet pressure values were: -8.88 ± 0.01, -23.69 ± 0.81 and -70.22 ± 0.18 mmHg for the wall-less cannula (P <0.0001), versus -36.69 ± 1.88, -80.85 ± 1.71 and -101.83 ± 0.45 mmHg for the thin-wall cannula (P <0.0001). The thin-wall cannula showed mean Q-values 37% less and mean P values 26% more when compared with the wall-less cannula (P <0.0001). CONCLUSIONS: Our in vitro water test was able to mimic a negative pressure situation, where the wall-less cannula design performs better compared with the traditional thin-wall cannula.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: It is still debatable whether anemia predicts stroke outcome. AIM: To describe the characteristics of patients with acute ischemic stroke (AIS) and anemia and identify whether hemoglobin status on admission is a prognostic factor of AIS outcome. METHODS: All 2439 patients of the Acute Stroke Registry and Analysis of Lausanne (ASTRAL) between January 2003 and June 2011 were selected. Demographics, risk factors, prestroke treatment, clinical, radiological and metabolic variables in patients with and without anemia according to the definition of the World Health Organization were compared. Functional disability and mortality were recorded up to 12 months from admission. RESULTS: Anemic patients (17.5%) were older, had lower body mass index, higher rates of coronary artery disease (CAD), atrial fibrillation, diabetes mellitus and peripheral artery disease. Anemia was associated with more severe stroke manifestations, lower systolic and diastolic blood pressure measurements, worse estimated glomerular filtration rate and elevated C-reactive protein concentrations upon admission and with increased modified Rankin scores during the follow-up. Anemic patients had higher 7-day, 3-month and 12-month mortality, which was associated with hemoglobin status and other factors, including age, CAD, stroke severity, and baseline C-reactive levels. Hemoglobin levels were inversely associated with recurrent stroke and mortality throughout the 12-month follow-up. CONCLUSION: Anemia is common among AIS patients and is associated with cardiovascular comorbidities. Low hemoglobin status independently predicts short and long-term mortality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: Chronic critical limb ischemia (CLI) often requires venous bypass grafting to distal arterial segments. However, graft patency is influenced by the length and quality of the graft and occasionally patients may have limited suitable veins. We investigated short distal bypass grafting from the superficial femoral or popliteal artery to the infrapopliteal, ankle or foot arteries, despite angiographic alterations of inflow vessels, providing that invasive pressure measurement at the site of the planned proximal anastomosis revealed an inflow-brachial pressure difference of <or=10 mmHg. METHODS: Four hundred and twenty-three consecutive infrainguinal bypass grafts were performed for CLI between June, 1999 and November, 2002 at our institution. All patients underwent preoperative clinical examination, arteriography and assessment of the veins by duplex ultrasound. The study group are patients in whom the proximal and distal anastomoses of the bypass are below the femoral bifurcation and the popliteal artery, respectively. Invasive arterial pressure measurements were recorded at the level of the planned proximal anastomosis which was performed at that level if the difference of the inflow-brachial pressure was <or=10 mmHg, irrespective of angiographic alterations of the inflow vessels proximal to the planned anastomosis. All patients had a clinical follow-up included a duplex examination of their graft, at 1 week, 3, 9 and 12 months and, thereafter, annually. No patient was lost to follow-up. RESULTS: Sixty-seven patients underwent 71 short distal bypass grafts in 71 limbs with reversed saphenous vein grafts in 52, in situ saphenous veins in 11, reversed cephalic vein in 1 and composite veins in 7, respectively. Surgical or endovascular interventions to improve inflow were required in 4 limbs (5.6%). The mean follow-up time was 22.5 months and the two-year survival was 92.5%. Primary and secondary patency rates at 2 years were 73% and 93%, respectively, and the limb salvage rate was 98.5%. CONCLUSION: In appropriately selected patients, short distal venous bypass grafts can be performed with satisfactory patency and limb salvage rates even in the presence of morphologic alterations of the inflow vessels providing that these are not hemodynamically significant, or can be corrected intraoperatively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diagnosis and treatment of arterial hypertension are essential in order to reduce the mortality and the morbidity associated with this condition. The decision to treat hypertension is often based on serial office blood pressure measurements, but new non-invasive measurements such as pulse wave velocity or central blood pressure measurement using pulse wave analysis can be useful to assess the cardiovascular risk with more precision. Indeed, pulse vawe velocity, which is a marker of arterial stiffness, is an independent risk factor for future cardiovascular events. Non-pharmacological and pharmacological therapies can affect both pulse wave velocity and central pressure. However, more studies are needed in order to determine if these measurements can be use as surrogate marker of cardiovascular disease.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel laboratory technique is proposed to investigate wave-induced fluid flow on the mesoscopic scale as a mechanism for seismic attenuation in partially saturated rocks. This technique combines measurements of seismic attenuation in the frequency range from 1 to 100?Hz with measurements of transient fluid pressure as a response of a step stress applied on top of the sample. We used a Berea sandstone sample partially saturated with water. The laboratory results suggest that wave-induced fluid flow on the mesoscopic scale is dominant in partially saturated samples. A 3-D numerical model representing the sample was used to verify the experimental results. Biot's equations of consolidation were solved with the finite-element method. Wave-induced fluid flow on the mesoscopic scale was the only attenuation mechanism accounted for in the numerical solution. The numerically calculated transient fluid pressure reproduced the laboratory data. Moreover, the numerically calculated attenuation, superposed to the frequency-independent matrix anelasticity, reproduced the attenuation measured in the laboratory in the partially saturated sample. This experimental?numerical fit demonstrates that wave-induced fluid flow on the mesoscopic scale and matrix anelasticity are the dominant mechanisms for seismic attenuation in partially saturated Berea sandstone.