8 resultados para PLAN SECTORIAL DE TURISMO NACIONAL 2008-2011
em Université de Lausanne, Switzerland
Resumo:
Although active personal dosemeters (APDs) are not used quite often in hospital environments, the possibility to assess the dose and/or dose rate in real time is particularly interesting in interventional radiology and cardiology (IR/IC) since operators can receive relatively high doses while standing close to the primary radiation field.A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. This paper reports on tests performed with APDs on phantoms using an X-ray facility in a hospital environment and APDs worn by interventionalists during routine practice in different European hospitals.The behaviour of the APDs is more satisfactory in hospitals than in laboratories with respect to the influence of the tube peak high voltage and pulse width, because the APDs are tested in scattered fields with dose equivalent rates generally lower than 1 Sv.h(-1).
Resumo:
BACKGROUND: Polymorphisms in IFNL3 and IFNL4, the genes encoding interferon λ3 and interferon λ4, respectively, have been associated with reduced hepatitis C virus clearance. We explored the role of such polymorphisms on the incidence of cytomegalovirus (CMV) infection in solid-organ transplant recipients. METHODS: White patients participating in the Swiss Transplant Cohort Study in 2008-2011 were included. A novel functional TT/-G polymorphism (rs368234815) in the CpG region upstream of IFNL3 was investigated. RESULTS: A total of 840 solid-organ transplant recipients at risk for CMV infection were included, among whom 373 (44%) received antiviral prophylaxis. The 12-month cumulative incidence of CMV replication and disease were 0.44 and 0.08 cases, respectively. Patient homozygous for the minor rs368234815 allele (-G/-G) tended to have a higher cumulative incidence of CMV replication (subdistribution hazard ratio [SHR], 1.30 [95% confidence interval {CI}, .97-1.74]; P = .07), compared with other patients (TT/TT or TT/-G). The association was significant among patients followed by a preemptive approach (SHR, 1.46 [95% CI, 1.01-2.12]; P = .047), especially in patients receiving an organ from a seropositive donor (SHR, 1.92 [95% CI, 1.30-2.85]; P = .001), but not among those who received antiviral prophylaxis (SHR, 1.13 [95% CI, .70-1.83]; P = .6). These associations remained significant in multivariate competing risk regression models. CONCLUSIONS: Polymorphisms in the IFNL3/4 region influence susceptibility to CMV replication in solid-organ transplant recipients, particularly in patients not receiving antiviral prophylaxis.
Resumo:
Introduction: Following a disaster, up to 50% of mass casualties are children. The number of disaster increases worldwide, including in Switzerland. Following national order, the mapping of the various risks of disaster in Switzerland will be completed by the end of 2012. Pre-hospital disaster drills and plans are well established and regularly tested. In-hospital disaster plans are much less frequently tested, if only available. Pediatric in-hospital full scale disaster exercises have never been reported in Switzerland. Based on our local constraints, we set up and evaluated a disaster plan during two full scale exercises. Methods: In a university hospital treating more than 35 000 pediatric emergencies per year, two exercises involving mock victims of a disaster aged 9 to 14 years old were successively set up over a period of 3 years. The exercises were planned during the day, without modification of the normal emergency room activities. The hospital staff was informed and trained in advance. Variables such as the alarm timing and transmission, triage set-up and function, special disaster medical records utilization, communication and victims' identification were assessed. Family members participated in the second exercise. An evaluation team observed and record exercises activities, identifying strength and weaknesses. Results: On two separate occasions, a total of 44 mock patients participated, were triaged, admitted and treated in the hospital according to usual standards of care. Alarm transmission was not appropriate during the first exercise. Triage overload occurred on one occasion. In-hospital communication needed readjustment. Identification and in-hospital tracking of the children remained problematic. Hospital employees showed great enthusiasm and stressed the positive effect of full scale exercises on their knowledge of the hospital disaster plan. Conclusions: Performing real life disaster exercises in a pediatric hospital was very beneficial. The disaster plan was adapted to local needs and updated accordingly. An alarm transmission protocol was elaborated and tested. Triage set-up was adapted and tested. A hospital identification plan for injured children was created and tested. Full scale hospital exercises evaluating disaster plans revealed several weaknesses in the system. Practice readjustments based on local experience were made. A tested pediatric disaster plan adapted to local constraints could minimize chaos, optimize care and support in the event of a real disaster. Children's identification and family reunification following a disaster remains a challenge.
Resumo:
The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, (99m)Tc- and (18)F-labelled radiopharmaceuticals for diagnostic and (90)Y-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure.
Resumo:
Haematopoietic stem cell transplantation (HSCT) is a highly specialised procedure used to treat malignancies of the lymphohaematopoietic system as well as some acquired and inherited disorders of the blood. This analysis by the Swiss Blood Stem Cell Transplantation Group, based on data from 2008-2011, describes, treatment rates in Switzerland for specific indications and compares this with data from Germany, France, Italy and the Netherlands, corrected for the size of the population. Differences in transplant rates, in rates for particular indications, and in the use of specific transplant technologies such as use of unrelated donors, use of cord blood or mismatched family donors are described. These data are put in correlation with donor availability from international registries and with number of transplant teams and number of procedures per team all corrected for population size.
Resumo:
The main aim of the Work Package 1 (WP1) of the ORAMED project, Collaborative Project (2008-2011), supported by the European Commission within its 7th Framework Programme, was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology and cardiology (IR/IC) workplaces and to recommend a series of guidelines on radiation protection in order to both guarantee and optimize staff protection. Within the project, coordinated measurements were performed in 34 hospitals in 6 European countries. Furthermore, simulations of the most representative workplaces in IR and IC were performed to determine the main parameters that influence the extremity and eye lens doses. The work presented in this paper shows the recommendations that were formulated by the results obtained from both measurements and simulations. The presented guidelines are directed to operators, assistant personnel, radiation protection officers and medical physics experts. They concern radiation protection issues, such as the use of room protective equipment, as well as the positioning of the extremity and eye lens dosemeters for routine monitoring.
Resumo:
Active personal dosemeters (APD) have been found to be very efficient tools to reduce occupational doses in many applications of ionizing radiation. In order to be used in interventional radiology and cardiology (IR/IC), APDs should be able to measure low energy photons and pulsed radiation with relatively high instantaneous personal dose equivalent rates. A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. In particular, eight commercial APDs were tested in continuous and pulsed X-ray fields delivered by calibration laboratories in order to evaluate their performances. Most of APDs provide a response in pulsed mode more or less affected by the personal dose equivalent rate, which means they could be used in routine monitoring provided that correction factors are introduced. These results emphasize the importance of adding tests in pulsed mode in type-test procedures for APDs. Some general recommendations are proposed in the end of this paper for the selection and use of APDs at IR/IC workplaces.