244 resultados para PHENYLEPHRINE INFUSION
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND: The alpha1-adrenergic receptors (alpha1-ARs) play a key role in cardiovascular homeostasis. However, the functional role of alpha1-AR subtypes in vivo is still unclear. The aim of this study was to evaluate the cardiovascular influences of alpha1b-AR. METHODS AND RESULTS: In transgenic mice lacking alpha1-AR (KO) and their wild-type controls (WT), we evaluated blood pressure profile and cardiovascular remodeling induced by the chronic administration (18 days via osmotic pumps) of norepinephrine, angiotensin II, and subpressor doses of phenylephrine. Our results indicate that norepinephrine induced an increase in blood pressure levels only in WT mice. In contrast, the hypertensive state induced by angiotensin II was comparable between WT and KO mice. Phenylephrine did not modify blood pressure levels in either WT or KO mice. The cardiac hypertrophy and eutrophic vascular remodeling evoked by norepinephrine was observed only in WT mice, and this effect was independent of the hypertensive state because it was similar to that observed during subpressor phenylephrine infusion. Finally, the cardiac hypertrophy induced by thoracic aortic constriction was comparable between WT and KO mice. CONCLUSIONS: Our data demonstrate that the lack of alpha1b-AR protects from the chronic increase of arterial blood pressure induced by norepinephrine and concomitantly prevents cardiovascular remodeling evoked by adrenergic activation independently of blood pressure levels.
Resumo:
The recent developments in high magnetic field 13C magnetic resonance spectroscopy with improved localization and shimming techniques have led to important gains in sensitivity and spectral resolution of 13C in vivo spectra in the rodent brain, enabling the separation of several 13C isotopomers of glutamate and glutamine. In this context, the assumptions used in spectral quantification might have a significant impact on the determination of the 13C concentrations and the related metabolic fluxes. In this study, the time domain spectral quantification algorithm AMARES (advanced method for accurate, robust and efficient spectral fitting) was applied to 13 C magnetic resonance spectroscopy spectra acquired in the rat brain at 9.4 T, following infusion of [1,6-(13)C2 ] glucose. Using both Monte Carlo simulations and in vivo data, the goal of this work was: (1) to validate the quantification of in vivo 13C isotopomers using AMARES; (2) to assess the impact of the prior knowledge on the quantification of in vivo 13C isotopomers using AMARES; (3) to compare AMARES and LCModel (linear combination of model spectra) for the quantification of in vivo 13C spectra. AMARES led to accurate and reliable 13C spectral quantification similar to those obtained using LCModel, when the frequency shifts, J-coupling constants and phase patterns of the different 13C isotopomers were included as prior knowledge in the analysis.
Resumo:
Continuous infusion of vancomycin was evaluated against experimental endocarditis due to heterogeneous vancomycin-intermediate Staphylococcus aureus (hVISA) and VISA. Animals were infected with hVISA PC1 (vancomycin MIC, 2 mg/liter) or VISA PC3 (vancomycin MIC, 8 mg/liter) and treated for 5 days with constant serum levels of 20 or 40 mg/liter. Vancomycin continuous infusion was unsuccessful, as 20 mg/liter was barely active against PC1 (6 of 13 sterile vegetations) and 40 mg/liter failed against PC3 (2 of 9 sterile vegetations).
Resumo:
Atrial natriuretic peptides (ANP) exert vasodilating and natriuretic actions. The present study was undertaken to test the effect of low dose infusions of synthetic ANP on hemodynamic and humoral variables of patients with severe heart failure. Eight patients, aged 26 to 71 years, with severe congestive heart failure due to ischemic heart disease or idiopathic dilated cardiomyopathy were included in the study. Synthetic human (3-28) ANP was infused at doses ranging from 0.5 to 2 micrograms/min for up to 3 h. Pulmonary capillary wedge pressure fell from 24 +/- 1 to 16 +/- 2 mm Hg (mean +/- SEM) (p less than 0.01) and cardiac index tended to rise from 2 +/- 0.2 to 2.3 +/- 0.2 L/min/m2 (NS), while blood pressure and heart rate did not change. One patient experienced a marked drop in pulmonary capillary wedge and arterial blood pressure that necessitated the administration of saline. ANP infusion did not alter plasma renin activity or plasma aldosterone, norepinephrine, or vasopressin levels. It decreased plasma epinephrine levels from 0.472 +/- 0.077 to 0.267 +/- 0.024 nmol/L (p less than 0.05). Plasma ANP levels were markedly elevated in all patients before initiating the infusion. They had no predictive value for the hemodynamic response to exogenous ANP. No correlation was observed between the hemodynamic effects of ANP and those induced by the subsequently administered converting enzyme inhibitor captopril, which seemed to improve cardiac function more consistently.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
This randomized study compares the coronary perfusion rate in patients with acute myocardial infarction (AMI) treated with 2 different intravenous thrombolytic agents: streptokinase 1.5 million U given over 60 minutes and anisoylated human plasminogen streptokinase activator complex (anistreplase) administrated as a bolus of 30 U over 5 minutes. One hundred seventy-five patients (149 men and 26 women, mean age 54 years) have been included in this study. Eighty-nine patients were treated with anistreplase and 86 patients with streptokinase. AMI was inferior in 54 patients (61%) in the anistreplase group and in 54 patients (63%) in the streptokinase group. It was anterior in 35 (40%) and 32 (37%) patients, respectively. Coronary angiography and ventriculography were performed at a mean time (+/- SEM) of 207 +/- 11 minutes after the beginning of thrombolysis in 170 patients. A perfusion score grade of 2 or 3 according to the Thrombolysis in Myocardial Infarction trial was found in 63 patients (72%) in the anistreplase group and in 56 patients (68%) in the streptokinase group (p = NS). Severe bleeding occurred in 7 patients (8%) after anistreplase and in 6 patients (7%) after streptokinase. No cerebral hemorrhage occurred. Nine patients (5%) died during their hospital stay: 6 after anistreplase and 3 after streptokinase. It is concluded that intravenous administration of anistreplase or streptokinase is efficient and safe. Coronary patency 207 minutes after fibrinolysis, incidence of adverse events and mortality are similar in both groups.
Resumo:
OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.
Resumo:
The change in energy expenditure consecutive to the infusion of glucose/insulin was examined in 17 non-obese (ten young, seven middle-aged) and 27 diabetic and non-diabetic obese subjects by employing the euglycemic insulin clamp technique in conjunction with continuous indirect calorimetry. The obese subjects were divided into four groups according to their response to a 100-g oral glucose test: group A, normal glucose tolerance; group B, impaired glucose tolerance; group C, diabetes with increased insulin response; group D, diabetes with reduced insulin response. The glucose/insulin infusion provoked an increase in energy expenditure in both young and middle-aged controls (+8.2 +/- 1.3 percent and +5.9 +/- 0.5 percent over the preinfusion baseline respectively), but a lower increase in the non-diabetic obese groups A and B (+4.0 +/- 0.7 percent and +2.0 +/- 1.0 percent over the preinfusion baseline respectively, P less than 0.05 and P less than 0.01 vs young controls). However, in the diabetic obese groups C and D, energy expenditure failed to increase in response to the glucose/insulin infusion (mean change: +0.1 +/- 1.0 percent and -2.0 +/- 1.9 percent (P less than 0.01, vs middle-aged) over the preinfusion baseline respectively). When the glucose-induced thermogenesis (GIT) was related to the glucose uptake--taking into account the hepatic glucose production--the GIT was found to be similarly reduced in the diabetics groups (C and D). The net change in the rate of energy expenditure was found to be significantly correlated with the rate of glucose uptake (r = +0.647, n = 44, P less than 0.001) when all the individuals were pooled. In conclusion, this study shows that the low glucose-induced thermogenesis in obese diabetics during glucose insulin infusion is mainly related to a reduced rate of glucose uptake; in addition, inhibition of gluconeogenesis by the glucose/insulin infusion may also contribute to decrease the thermogenic response.
Resumo:
We wished to determine if chronic neuropeptide Y (NPY) infusion (1 ng/min for 1 week by Alzet minipump) could decrease plasma renin activity (PRA) and norepinephrine (NE) in a rat myocardial infarction (MI) model of moderate compensated congestive heart failure (CHF). CHF was produced by prior (6-8 weeks) ligation of the left coronary artery; control rats were sham-operated. Carotid arterial blood was drawn for PRA and NE in conscious unrestrained rats that had been instrumented 24 h earlier. MI rats had increased PRA as compared with sham-operated rats [8.73 +/- 1.27 vs. 5.10 +/- 0.91 ng angiotensin (AI) I/ml.h, mean +/- SE]. During chronic NPY infusion, PRA was reduced to normal in the MI group (4.78 +/- 0.91) but was not affected in the sham group (5.65 +/- 0.51). Plasma NE was altered similarly, but the changes did not reach statistical significance. These data suggest that NPY has the capacity to restrain renin release in moderate compensated CHF.
Resumo:
Effet d'un bolus intraveineux de phénylephrine ou d'éphedríne sur le flux sanguin cutané lors d'une anesthésie rachidienne Introduction : La phénylephrine et l'éphedrine sont des substances vaso-actives utilisées de routine pour corriger des épisodes d'hypotension artérielle induits par l'anesthésie intrarachidienne. L'influence de ces deux vasopresseurs sur le flux sanguin cutané (FSC) dans ce contexte n'a jusqu'à maintenant pas été décrite. Cette étude évalue l'effet d'une injection intraveineuse de 75 µg de phénylephrine ou de 7.5 mg d'éphedrine sur le FSC mesuré par Laser Doppler, dans les zones concernées parle bloc sympathiqué induit par l'anesthésie intrarachidienne (membres inférieurs) et dans les zones non concernées (membres supérieurs). Méthode :Après acceptation par le Comité d'Éthique, et obtention de leur accord écrit, 20 patients devant subir une intervention chirurgicale élective en décubitus dorsal sous anesthésie. intrarachidienne ont été inclus dans cette étude randomisée en double insu. Le FSC a été mesuré en continu par deux sondes fixées l'une à la cuisse (zone avec bloc sympathique) et l'autre sur l'avantbras (zone sans bloc sympathique). Les valeurs de FSC ont été enregistrées après l'anesthésie rachidienne (valeur contrôle), puis après l'injection i.v. dè phénylephrine (10 patients) ou d'éphedrine (10 patients) pour corriger une hypotension définie comme une chute de 20 mmHg de la pression artérielle systolique. Les variations de FSC exprimées en pourcentage de la valeur contrôle moyenne (+/- écart type) ont été analysées par le test t de Student. Résultats :Les données démographiques des patients et le niveau sensitif induit par l'anesthésie rachidienne sont similaires dans les deux groupes. Aux doses utilisées, seule l'éphedrine restaure la pression artérielle aux valeurs précédant l'anesthésie rachidienne. La phénylephrine augmente le FSC de l'avant-bras de 44% (+/- 79%) et de la cuisse de 34% (+/-24%), alors que l'éphedrine diminue le débit sanguin cutané de l'avant-bras de 16% (+/- 15%) et de la cuisse de 22% (+/-11%). Conclusion : L'injection intraveineuse de phénylephrine et d'éphedrine ont des effets opposés sur le flux sanguin cutané, et cette réponse n'est pas modifiée par le bloc sympathique.. Cette différence peut s'expliquer par la distribution des sous-types de récepteurs adrénergiques alpha et leur prédominance relative dans les veines et les artères de différents diamètres perfusant le tissu sous-cutané et la peau. L'éphedrine, èn raison de sa meilleure efficacité pour traiter les épisodes d'hypotension artérielle après anesthésie intrarachidienne devrait être préféré à la phénylephrine, leurs effets opposés sur le flux sanguin cutané n'étant pas pertinents en pratique clinique. SUMMARY Background: Phenylephrine or ephedrine is routinely used to correct hypotensive episodes fallowing spinal anaesthesia (SA). The influence of these two vasopressors on skin blood flow (SBF) has not yet been described. We have therefore evaluated the effects of an i.v. bolus of 75 µg phenylephrine or 7.5 mg of ephedrine on SBF measured by laser Doppler flowmetry during sympathetic blockade induced by SA. Methods: With Ethical Committee approval and written consent, 20 patients scheduled for elective procedures in supine position under SA were enrolled in this double-blind randomized study. SBF was measured continuously by two probes fixed at the thigh (area with sympathic blockade) and forearm level (area without sympathic blockade) respectively. SBF values were recorded after SA (control values) and then after a bolus administration of phenylephriné (n=10) or ephedrine (n=10) when systolic blood pressure decreased by 20 mmHg. Changes were expressed as percentage of control SBF values and analysed by Student's paired t-test. Results: Patient characteristics and dermatomal sensory levels were similar in both groups. Phenylephrine increases mean SBF at the forearm level by 44% (79%) [mean (SD)j and at the thigh by 34% (24%). Ephedrine decreases SBF at the forearm level by 16% (15%) and at the thigh by 22% (il%). Ephedrine bolus restores arterial blood pressure to pre-anaesthesia values, whereas phenylephrine does not. Conclusion: Administratión of phenylephrine and ephedrine has opposite effects on skin blood flow and sympathetic blockade does not modify this response. These findings could be explained by the distribution of the alpha-adrenoréceptor subtypes and their relative predominance among veins and arteries of different size perfusing the subcutaneous tissue and the skin. Ephedrine, due to its better efficacy to correct hypotensive episodes following SA, should be preferred, to phenylephrine, their opposite effects on SBF being not relevant for clinical practice.
Resumo:
OBJECTIVE. The purpose of this study was to improve the blood-pool signal-to-noise ratio (SNR) and blood-myocardium contrast-to-noise ratio (CNR) of slow-infusion 3-T whole-heart coronary MR angiography (MRA).SUBJECTS AND METHODS. In 2D sensitivity encoding (SENSE), the number of acquired k-space lines is reduced, allowing less radiofrequency excitation per cardiac cycle and a longer TR. The former can be exploited for signal enhancement with a higher radiofrequency excitation angle, and the latter leads to noise reduction due to lower data-sampling bandwidth. Both effects contribute to SNR gain in coronary MRA when spatial and temporal resolution and acquisition time remain identical. Numeric simulation was performed to select the optimal 2D SENSE pulse sequence parameters and predict the SNR gain. Eleven patients underwent conventional unenhanced and the proposed 2D SENSE contrast-enhanced coronary MRA acquisition. Blood-pool SNR, blood-myocardium CNR, visible vessel length, vessel sharpness, and number of side branches were evaluated.RESULTS. Consistent with the numeric simulation, using 2D SENSE in contrast-enhanced coronary MRA resulted in significant improvement in aortic blood-pool SNR (unenhanced vs contrast-enhanced, 37.5 +/- 14.7 vs 121.3 +/- 44.0; p < 0.05) and CNR (14.4 +/- 6.9 vs 101.5 +/- 40.8; p < 0.05) in the patient sample. A longer length of left anterior descending coronary artery was visualized, but vessel sharpness, coronary artery coverage, and image quality score were not improved with the proposed approach.CONCLUSION. In combination with contrast administration, 2D SENSE was found effective in improving SNR and CNR in 3-T whole-heart coronary MRA. Further investigation of cardiac motion compensation is necessary to exploit the SNR and CNR advantages and to achieve submillimeter spatial resolution.
Resumo:
Hemodynamic and biochemical effects of the new renin inhibitor CGP 38560A (molecular weight 826) were tested in 15 healthy volunteers after a single-blind, randomized, placebo-controlled protocol. At a 2-week interval, groups of five subjects received a 30-minute infusion of either 5% dextrose or CGP 38560A 50, 125, or 250 micrograms/kg. Blood pressure, heart rate, plasma renin activity, active and total renin, angiotensin-(1-8)octapeptide (angiotensin II), and aldosterone were sequentially measured up to 3 hours from the onset of the infusion. There was no consistent change in blood pressure or heart rate. Plasma renin activity and angiotensin II decreased dose dependently, and peak suppression was observed at the end of the infusion of CGP 38560A and after the 250-micrograms/kg dose. Plasma renin activity fell from 1.0 +/- 0.19 (mean +/- SEM) to less than 0.05 ng/ml/hr in all five subjects (p less than 0.001), and angiotensin II fell from 7.7 +/- 1.2 to 2.6 +/- 0.9 femtomole/ml (p less than 0.01). Active renin rose fourfold from 24 +/- 1.9 to 98 +/- 14 pg/ml (p less than 0.001) at the end of the infusion of the high dose. Plasma angiotensin II returned toward its initial values much faster than plasma renin activity and active renin. In conclusion, CGP 38560A was well tolerated. It induced a dose-dependent decrease in angiotensin II and plasma renin activity and a long-lasting and dose-dependent rise in active renin. The doses used did not reduce plasma angiotensin II maximally despite reduction of plasma renin activity to unmeasurable levels.(ABSTRACT TRUNCATED AT 250 WORDS)