107 resultados para Oxygen Storage

em Université de Lausanne, Switzerland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

RATIONALE The choice of containers for storage of aqueous samples between their collection, transport and water hydrogen (2H) and oxygen (18O) stable isotope analysis is a topic of concern for a wide range of fields in environmental, geological, biomedical, food, and forensic sciences. The transport and separation of water molecules during water vapor or liquid uptake by sorption or solution and the diffusive transport of water molecules through organic polymer material by permeation or pervaporation may entail an isotopic fractionation. An experiment was conducted to evaluate the extent of such fractionation. METHODS Sixteen bottle-like containers of eleven different organic polymers, including low and high density polyethylene (LDPE and HDPE), polypropylene (PP), polycarbonate (PC), polyethylene terephthalate (PET), and perfluoroalkoxy-Teflon (PFA), of different wall thickness and size were completely filled with the same mineral water and stored for 659?days under the same conditions of temperature and humidity. Particular care was exercised to keep the bottles tightly closed and prevent loss of water vapor through the seals. RESULTS Changes of up to +5 parts per thousand for d2H values and +2.0 parts per thousand for d18O values were measured for water after more than 1?year of storage within a plastic container, with the magnitude of change depending mainly on the type of organic polymer, wall thickness, and container size. The most important variations were measured for the PET and PC bottles. Waters stored in glass bottles with Polyseal (TM) cone-lined PP screw caps and thick-walled HDPE or PFA containers with linerless screw caps having an integrally molded inner sealing ring preserved their original d2H and d18O values. The carbon, hydrogen, and oxygen stable isotope compositions of the organic polymeric materials were also determined. CONCLUSIONS The results of this study clearly show that for precise and accurate measurements of the water stable isotope composition in aqueous solutions, rigorous sampling and storage procedures are needed both for laboratory standards and for unknown samples. Copyright (c) 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A set of bottled waters from a single natural spring distributed worldwide in polyethylene terephthalate (PET) bottles has been used to examine the effects of storage in plastic polymer material on the isotopic composition (delta(18)O and delta(2)H values) of the water. All samples analyzed were subjected to the same packaging procedure but experienced different conditions of temperature and humidity during storage. Water sorption and the diffusive transfer of water and water vapor through the wall of the PET bottle may cause isotopic exchange between water within the bottle and water vapor in air near the PET-water interface. Changes of about +4 parts per thousand for delta(2)H and +0.7 parts per thousand for delta(18)O have been measured for water after 253 days of storage within the PET bottle. The results of this study clearly indicate the need to use glass bottles for storing water samples for isotopic studies. It is imperative to transfer PET-bottled natural waters to glass bottles for their use as calibration material or potential international working standards. Copyright (C) 2008 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Erythrocyte concentrates (ECs) are the major labile blood product being transfused worldwide, aiming at curing anemia of diverse origins. In Switzerland, ECs are stored at 4 °C up to 42 days in saline-adenine-glucose-mannitol (SAGM). Such storage induces cellular lesions, altering red blood cells (RBCs) metabolism, protein content and rheological properties. A hot debate exists regarding the impact of the storage lesions, thus the age of ECs on transfusion-related clinical adverse outcomes. Several studies tend to show that poorer outcomes occur in patients receiving older blood products. However, no clear association was demonstrated up to date. While metabolism and early rheological changes are reversible through transfusion of the blood units, oxidized proteins cannot be repaired, and it is likely such irreversible damages would affect the quality of the blood product and the efficiency of the transfusion. In vivo, RBCs are constantly exposed to oxygen fluxes, and are thus well equipped to deal with oxidative challenges. Moreover, functional 20S proteasome complexes allow for recognition and proteolysis of fairly oxidized protein, and some proteins can be eliminated from RBCs by the release of microvesicles. The present PhD thesis is involved in a global research project which goal is to characterize the effect of processing and storage on the quality of ECs. Assessing protein oxidative damages during RBC storage is of major importance to understand the mechanisms of aging of stored RBCs. To this purpose, redox proteomic-based investigations were conducted here. In a first part, cysteine oxidation and protein carbonylation were addressed via 2D-DIGE and derivatization-driven immunodetection approaches, respectively. Then, the oxidized sub- proteomes were characterized through LC-MS/MS identification of proteins in spots of interest (cysteine oxidation) or affinity-purified carbonylated proteins. Gene ontology annotation allowed classifying targets of oxidation according to their molecular functions. In a third part, the P20S activity was evaluated throughout the storage period of ECs, and its susceptibility to highly oxidized environment was investigated. The potential defensive role of microvesiculation was also addressed through the quantification of eliminated carbonylated proteins. We highlighted distinct protein groups differentially affected by cysteine oxidation, either reversibly or irreversibly. In addition, soluble extracts showed a decrease in carbonylation at the beginning of the storage and membrane extracts revealed increasing carbonylation after 4 weeks of storage. Engaged molecular functions revealed that antioxidant (AO) are rather reversibly oxidized at their cysteine residue(s), but are irreversibly oxidized through carbonylation. In the meantime, the 20S proteasome activity is decreased by around 40 % at the end of the storage period. Incubation of fresh RBCs extracts with exogenous oxidized proteins showed a dose-dependent and protein-dependent inhibitory effect. Finally, we proved that the release of microvesicles allows the elimination of increasing quantities of carbonylated proteins. Taken together, these results revealed an oxidative pathway model of RBCs storage, on which further investigation towards improved storage conditions will be based. -- Les concentrés érythrocytaires (CE) sont le produit sanguin le plus délivré au monde, permettant de traiter différentes formes d'anémies. En Suisse, les CE sont stocké à 4 °C pendant 42 jours dans une solution saline d'adénine, glucose et mannitol (SAGM). Une telle conservation induit des lésions de stockage qui altèrent le métabolisme, les protéines et les propriétés rhéologique du globule rouge (GR). Un débat important concerne l'impact du temps de stockage des CE sur les risques de réaction transfusionnelles, certaines études tentant de démontrer que des transfusions de sang vieux réduiraient l'espérance de vie des patients. Cependant, aucune association concrète n'a été prouvée à ce jour. Alors que les modifications du métabolisme et changement précoces des propriétés rhéologiques sont réversibles suite à la transfusion du CE, les protéines oxydées ne peuvent être réparées, et il est probable que de telles lésions affectent la qualité et l'efficacité des produits sanguins. In vivo, les GR sont constamment exposés à l'oxygène, et sont donc bien équipés pour résister aux lésions oxydatives. De plus, les complexes fonctionnels de proteasome 20S reconnaissent et dégradent les protéines modérément oxydées, et certaines protéines peuvent être éliminées par les microparticules. Cette thèse de doctorat est imbriquée dans un projet de recherche global ayant pour objectif la caractérisation des effets de la préparation et du stockage sur la qualité des GR. Evaluer les dommages oxydatifs du GR pendant le stockage est primordial pour comprendre les mécanismes de vieillissement des produits sanguin. Dans ce but, des recherches orientées redoxomique ont été conduites. Dans une première partie, l'oxydation des cystéines et la carbonylation des protéines sont évaluées par électrophorèse bidimensionnelle différentielle et par immunodétection de protéines dérivatisées. Ensuite, les protéines d'intérêt ainsi que les protéines carbonylées, purifiées par affinité, sont identifiées par spectrométrie de masse en tandem. Les protéines cibles de l'oxydation sont classées selon leur fonction moléculaire. Dans une troisième partie, l'activité protéolytique du protéasome 20S est suivie durant la période de stockage. L'impact du stress oxydant sur cette activité a été évalué en utilisant des protéines exogènes oxydées in vitro. Le potentiel rôle défensif de la microvesiculation a également été étudié par la quantification des protéines carbonylées éliminées. Dans ce travail, nous avons observé que différents groupes de protéines sont affectés par l'oxydation réversible ou irréversible de leurs cystéines. De plus, une diminution de la carbonylation en début de stockage dans les extraits solubles et une augmentation de la carbonylation après 4 semaines dans les extraits membranaires ont été montrées. Les fonctions moléculaires engagées par les protéines altérées montrent que les défenses antioxydantes sont oxydées de façon réversible sur leurs résidus cystéines, mais sont également irréversiblement carbonylées. Pendant ce temps, l'activité protéolytique du protéasome 20S décroit de 40 % en fin de stockage. L'incubation d'extraits de GR en début de stockage avec des protéines oxydées exogènes montre un effet inhibiteur « dose-dépendant » et « protéine-dépendant ». Enfin, les microvésicules s'avèrent éliminer des quantités croissantes de protéines carbonylées. La synthèse de ces résultats permet de modéliser une voie oxydative du stockage des GRs, à partir de laquelle de futures recherches seront menées avec pour but l'amélioration des conditions de stockage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crystallization temperatures of the oceanic carbonatites of Fuerteventura, Canary Islands, have been determined from oxygen isotope fractionations between calcite, silicate minerals (feldspar, pyroxene, biotite, and zircon) and magnetite. The measured fractionations have been interpreted in the light of late stage interactions with meteoric and/or magmatic water. Cathodoluminescence characteristics were investigated for the carbonatite minerals in order to determine the extent of alteration and to select unaltered samples. Oxygen isotope fractionations of minerals of unaltered samples yield crystallization temperatures between 450 and 960degreesC (average 710degreesC). The highest temperature is obtained from pyroxene-calcite pairs. The above range is in agreement with other carbonatite thermometric Studies. This is the first study that provides oxygen isotope data coupled with a CL study on carbonatite-related zircon. The CL pictures revealed that the zircon is broken and altered in the carbonatites and in associated syenites. Regarding geological field evidences of syenite-carbonatite relationship and the close agreement of published zircon U/Pb and whole rock and biotite K/Ar and Ar-Ar age data, the most probable process is early zircon crystallization from the syenite magma and late-stage reworking during magma evolution and carbonatite segregation. The oxygen isotope fractionations between zircon and other carbonatite minerals (calcite and pyroxene) support the assumption that the zircon would correspond to the early crystallization of syenite-carbonatite magmas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxygen uptake was studied during the establishment of cephalocaudal polarity in the very early chick embryo, i.e., 10 hr before (stage VI) and at laying (stage X). Oxygen fluxes in minute regions of the intact blastoderms were measured in vitro by scanning microspectrophotometry in the presence or absence of glucose. The oxygen consumption of the whole blastoderm remained constant (6 nmol O2 X hr-1) throughout the period studied, although the number of cells increased more than twofold. The regional oxygen fluxes varied from 0.41 to 1.13 nmol O2 X hr-1 X mm-2 at stage VI and from 0.42 to 0.70 nmol O2 X hr-1 X mm-2 at stage X. At stage VI, the oxygen flux in the center of the blastoderm was significantly higher than that in its periphery. This pattern remained evident when the values were corrected for cell number or for cytoplasmic volume. At stage X, there was a tendency for the oxygen fluxes to decrease from the posterior to the anterior regions of the area pellucida. Thus the pattern of oxidative metabolism in the late uterine embryos seems to change from radial to bilateral. This change of symmetry probably reflects the process of formation of the embryonic axis. In addition, the fact that the oxygen uptake was similar in the presence or absence of glucose suggests that early chick embryos metabolize essentially intracellular stores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stable isotope composition of waters (delta H-2, delta O-18) can be used as a natural tracer of hydrologic processes in systems affected by acid mine drainage. We investigated the delta H-2 and delta O-18 values of pore waters from four oxidizing sulfidic mine tailings impoundments in different climatic regions of Chile (Piuquenes at La Andina with Alpine climate, Cauquenes and Caren at El Teniente with Mediterranean climate, and Talabre at the Chuquicamata deposit with hyperarid climate). No clear relationship was found between altitude and isotopic composition. The observed displacement of the tailings pore waters from the local meteoric water line toward higher delta O-18 values (by similar to +2% delta O-18 relative to delta H-2) is partly due to water-rock interaction processes, including hydration and O-isotope exchange with sulfates and Fe(III) oxyhydroxides produced by pyrite oxidation. In most tailings, from the saturated zone toward the surface, isotopically different zones can be distinguished. Zone I is characterized by an upward depletion of H-2 and O-18 in the pore waters from the saturated zone and the lowermost vadose zone, due to ascending diffused isotopically light water triggered by the constant loss of water vapor by evaporation at the surface. In zone II, the capillary flow of a mix of vapor and liquid water causes an evaporative isotopic enrichment in H-2 and O-18. At the top of the tailings in dry climate a zone III between the capillary zone and the surface contains isotopically light diffused and atmospheric water vapor. In temperate climates, the upper part of the profile is affected by recent rainfall and zone III may not differ isotopically from zone II.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated a new pulse oximeter designed to monitor beat-to-beat arterial oxygen saturation (SaO2) and compared the monitored SaO2 with arterial samples measured by co-oximetry. In 40 critically ill children (112 data sets) with a mean age of 3.9 years (range 1 day to 19 years), SaO2 ranged from 57% to 100%, and PaO2 from 27 to 128 mm Hg, heart rates from 85 to 210 beats per minute, hematocrit from 20% to 67%, and fetal hemoglobin levels from 1.3% to 60%; peripheral temperatures varied between 26.5 degrees and 36.5 degrees C. Linear correlation analysis revealed a good agreement between simultaneous pulse oximeter values and both directly measured SaO2 (r = 0.95) and that calculated from measured arterial PaO2 (r = 0.95). The device detected several otherwise unrecognized drops in SaO2 but failed to function in four patients with poor peripheral perfusion secondary to low cardiac output. Simultaneous measurements with a tcPO2 electrode showed a similarly good correlation with PaO22 (r = 0.91), but the differences between the two measurements were much wider (mean 7.1 +/- 10.3 mm Hg, range -14 to +49 mm Hg) than the differences between pulse oximeter SaO2 and measured SaO2 (1.5% +/- 3.5%, range -7.5% to -9%) and were not predictable. We conclude that pulse oximetry is a reliable and accurate noninvasive device for measuring saturation, which because of its rapid response time may be an important advance in monitoring changes in oxygenation and guiding oxygen therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Ethanol can account for up to 10 percent of the energy intake of persons who consume moderate amounts of ethanol. Its effect on energy metabolism, however, is not known. METHODS: We studied the effect of ethanol on 24-hour substrate-oxidation rates in eight normal men during two 48-hour sessions in an indirect-calorimetry chamber. In each session, the first 24 hours served as the control period. On the second day of one session, an additional 25 percent of the total energy requirement was added as ethanol (mean [+/- SD], 96 +/- 4 g per day); during the other session, 25 percent of the total energy requirement was replaced by ethanol, which was isocalorically substituted for lipids and carbohydrates. RESULTS: Both the addition of ethanol and the isocaloric substitution of ethanol for other foods reduced 24-hour lipid oxidation. The respective mean (+/- SE) decreases were 49.4 +/- 6.7 and 44.1 +/- 9.3 g per day (i.e., reductions of 36 +/- 3 percent and 31 +/- 7 percent from the oxidation rate during the control day; P less than 0.001 and P less than 0.0025). This effect occurred only during the daytime period (8:30 a.m. to 11:30 p.m.), when ethanol was consumed and metabolized. Neither the addition of ethanol to the diet nor the isocaloric substitution of ethanol for other foods significantly altered the oxidation of carbohydrate or protein. Both regimens including ethanol produced an increase in 24-hour energy expenditure (7 +/- 1 percent with the addition of ethanol, P less than 0.001; 4 +/- 1 percent with the substitution of ethanol for other energy sources, P less than 0.025). CONCLUSIONS: Ethanol, either added to the diet or substituted for other foods, increases 24-hour energy expenditure and decreases lipid oxidation. Habitual consumption of ethanol in excess of energy needs probably favors lipid storage and weight gain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Prediction of clinical course and outcome after severe traumatic brain injury (TBI) is important. OBJECTIVE: To examine whether clinical scales (Glasgow Coma Scale [GCS], Injury Severity Score [ISS], and Acute Physiology and Chronic Health Evaluation II [APACHE II]) or radiographic scales based on admission computed tomography (Marshall and Rotterdam) were associated with intensive care unit (ICU) physiology (intracranial pressure [ICP], brain tissue oxygen tension [PbtO2]), and clinical outcome after severe TBI. METHODS: One hundred one patients (median age, 41.0 years; interquartile range [26-55]) with severe TBI who had ICP and PbtO2 monitoring were identified. The relationship between admission GCS, ISS, APACHE II, Marshall and Rotterdam scores and ICP, PbtO2, and outcome was examined by using mixed-effects models and logistic regression. RESULTS: Median (25%-75% interquartile range) admission GCS and APACHE II without GCS scores were 3.0 (3-7) and 11.0 (8-13), respectively. Marshall and Rotterdam scores were 3.0 (3-5) and 4.0 (4-5). Mean ICP and PbtO2 during the patients' ICU course were 15.5 ± 10.7 mm Hg and 29.9 ± 10.8 mm Hg, respectively. Three-month mortality was 37.6%. Admission GCS was not associated with mortality. APACHE II (P = .003), APACHE-non-GCS (P = .004), Marshall (P < .001), and Rotterdam scores (P < .001) were associated with mortality. No relationship between GCS, ISS, Marshall, or Rotterdam scores and subsequent ICP or PbtO2 was observed. The APACHE II score was inversely associated with median PbtO2 (P = .03) and minimum PbtO2 (P = .008) and had a stronger correlation with amount of time of reduced PbtO2. CONCLUSION: Following severe TBI, factors associated with outcome may not always predict a patient's ICU course and, in particular, intracranial physiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In several colour polymorphic species, morphs differ in thermoregulation either because dark and pale surfaces absorb solar radiation to a different extent and/or because morphs differ in key metabolic processes. Morph-specific thermoregulation may potentially account for the observation that differently coloured individuals are frequently not randomly distributed among habitats, and differ in many respects, including behaviour, morphology, survival and reproductive success. In a wild population of the colour polymorphic tawny owl Strix aluco, a recent cross-fostering experiment showed that offspring raised and born from red mothers were heavier than those from grey mothers. In the present study, we tested in the same individuals whether these morph-specific offspring growth patterns were associated with a difference in metabolic rate between offspring of red and grey mothers. For this purpose, we measured nestling oxygen consumption under two different temperatures (laboratory measurements: 4 and 20 degrees C), and examined the relationships between these data sets and the colour morph of foster and biological mothers. After controlling for nestling body mass, oxygen consumption at 20 degrees C was greater in foster offspring raised by grey foster mothers. No relationship was found between nestling oxygen consumption and coloration of their biological mother. Therefore, our study indicates that in our experiment offspring raised by grey foster mothers showed not only a lower body mass than offspring raised by red foster mothers, but also consumed more oxygen under warm temperature. This further indicates that rearing conditions in nests of grey mothers were more stressful than in nests of red mothers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The root-colonizing bacterium Pseudomonas fluorescens CHA0 was used to construct an oxygen-responsive biosensor. An anaerobically inducible promoter of Pseudomonas aeruginosa, which depends on the FNR (fumarate and nitrate reductase regulation)-like transcriptional regulator ANR (anaerobic regulation of arginine deiminase and nitrate reductase pathways), was fused to the structural lacZ gene of Escherichia coli. By inserting the reporter fusion into the chromosomal attTn7 site of P. fluorescens CHA0 by using a mini-Tn7 transposon, the reporter strain, CHA900, was obtained. Grown in glutamate-yeast extract medium in an oxystat at defined oxygen levels, the biosensor CHA900 responded to a decrease in oxygen concentration from 210 x 10(2) Pa to 2 x 10(2) Pa of O(2) by a nearly 100-fold increase in beta-galactosidase activity. Half-maximal induction of the reporter occurred at about 5 x 10(2) Pa. This dose response closely resembles that found for E. coli promoters which are activated by the FNR protein. In a carbon-free buffer or in bulk soil, the biosensor CHA900 still responded to a decrease in oxygen concentration, although here induction was about 10 times lower and the low oxygen response was gradually lost within 3 days. Introduced into a barley-soil microcosm, the biosensor could report decreasing oxygen concentrations in the rhizosphere for a 6-day period. When the water content in the microcosm was raised from 60% to 85% of field capacity, expression of the reporter gene was elevated about twofold above a basal level after 2 days of incubation, suggesting that a water content of 85% caused mild anoxia. Increased compaction of the soil was shown to have a faster and more dramatic effect on the expression of the oxygen reporter than soil water content alone, indicating that factors other than the water-filled pore space influenced the oxygen status of the soil. These experiments illustrate the utility of the biosensor for detecting low oxygen concentrations in the rhizosphere and other soil habitats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Migmatites produced by low-pressure anatexis of basic dykes are found in a contact metamorphic aureole around a pyroxenite-gabbro intrusion (PX2), on Fuerteventura. Dykes outside and inside the aureole record interaction with meteoric water, with low or negative delta O-18 whole-rock values (+0.2 to -3.4 parts per thousand), decreasing towards the contact. Recrystallised plagioclase, diopside, biotite and oxides, from within the aureole, show a similar evolution with lowest delta O-18 values (-2.8, -4.2, - 4.4 and -7.6 parts per thousand, respectively) in the migmatite zone, close to the intrusion. Relict clinopyroxene phenocrysts preserved in all dykes, retain typically magmatic delta O-18 values up to the anatectic zone, where the values are lower and more heterogeneous. Low delta O-18 values, decreasing towards the intrusion, can be ascribed to the advection of meteoric water during magma emplacement, with increasing fluid/rock ratios (higher dyke intensities towards the intrusion acting as fluid-pathways) and higher temperatures promoting increasing exchange during recrystallisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate preretinal partial pressure of oxygen (PO2) gradients before and after experimental pars plana vitrectomy. METHODS: Arteriolar, venous, and intervascular preretinal PO2 gradients were recorded in 7 minipigs during slow withdrawal of oxygen-sensitive microelectrodes (10-μm tip diameter) from the vitreoretinal interface to 2 mm into the vitreous cavity. Recordings were repeated after pars plana vitrectomy and balanced salt solution (BSS) intraocular perfusion. RESULTS: Arteriolar, venous, and intervascular preretinal PO2 at the vitreoretinal interface were 62.3 ± 13.8, 22.5 ± 3.3, and 17.0 ± 7.5 mmHg, respectively, before vitrectomy; 97.7 ± 19.9, 40.0 ± 21.9, and 56.3 ± 28.4 mmHg, respectively, immediately after vitrectomy; and 59.0 ± 27.4, 25.2 ± 3.0, and 21.5 ± 4.5 mmHg, respectively, 2½ hours after interruption of BSS perfusion. PO2 2 mm from the vitreoretinal interface was 28.4 ± 3.6 mmHg before vitrectomy; 151.8 ± 4.5 mmHg immediately after vitrectomy; and 34.8 ± 4.1 mmHg 2½ hours after interruption of BSS perfusion. PO2 gradients were still present after vitrectomy, with the same patterns as before vitrectomy. CONCLUSION: Preretinal PO2 gradients are not eliminated after pars plana vitrectomy. During BSS perfusion, vitreous cavity PO2 is very high. Interruption of BSS perfusion evokes progressive equilibration of vitreous cavity PO2 with concomitant progressive return of preretinal PO2 gradients to their previtrectomy patterns. This indicates that preretinal diffusion of oxygen is not altered after vitrectomy. The beneficial effect of vitrectomy in ischemic retinal diseases or macular edema may be related to other mechanisms, such as increased oxygen convection currents or removal of growth factors and cytokines secreted in the vitreous.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine whether, during hemorrhagic shock, the effect of epinephrine on energy metabolism could be deleterious, by enhancing the oxygen requirement at a given level of oxygen delivery (DO2). DESIGN: Prospective, randomized, control trial. SETTING: Experimental laboratory. SUBJECTS: Two groups of seven mongrel dogs were studied. The epinephrine group received a continuous infusion of epinephrine (1 microgram/min/kg) while the control group received saline. INTERVENTION: Dogs were anesthetized with pentobarbital, and shock was produced by stepwise hemorrhage. MEASUREMENTS AND MAIN RESULTS: Oxygen consumption (VO2) was continuously measured by the gas exchange technique, while DO2 was independently calculated from cardiac output (measured by thermodilution) and blood oxygen content. A dual-lines regression fit was applied to the DO2 vs. VO2 plot. The intersection of the two regression lines defined the critical value of DO2. Values above critical DO2 belonged to phase 1, while phase 2 occurred below critical DO2. In the control group, VO2 was independent of DO2 during phase 1; VO2 was dependent on DO2 during phase 2. In the epinephrine group, the expected increase in VO2 (+19%) and DO2 (+50%) occurred under normovolemic conditions. During hemorrhage, VO2 immediately decreased, and the slope of phase 1 was significantly (p < .01) different from zero, and was significantly (p < .05) steeper than in the control group (0.025 +/- 0.005 vs. 0.005 +/- 0.010). However, the critical DO2 (8.7 +/- 1.7 vs. 9.7 +/- 2.4 mL/min/kg), the critical VO2 (5.6 +/- 0.5 vs. 5.5 +/- 0.9 mL/min/kg), and the slope of phase 2 (0.487 +/- 0.080 vs. 0.441 +/- 0.130) were not different from control values. CONCLUSIONS: The administration of pharmacologic doses of epinephrine significantly increased VO2 under normovolemic conditions due to the epinephrine-induced thermogenic effect. This effect progressively decreased during hemorrhage. The critical DO2 and the relationship between DO2 and VO2 in the supply-dependent phase of shock were unaffected by epinephrine infusion. These results suggest that during hemorrhagic shock, epinephrine administration did not exert a detrimental effect on the relationship between DO2 and VO2.