64 resultados para Neonates, EEG Analysis, Seizures, Signal Processing

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate an automated seizure detection (ASD) algorithm in EEGs with periodic and other challenging patterns. METHODS: Selected EEGs recorded in patients over 1year old were classified into four groups: A. Periodic lateralized epileptiform discharges (PLEDs) with intermixed electrical seizures. B. PLEDs without seizures. C. Electrical seizures and no PLEDs. D. No PLEDs or seizures. Recordings were analyzed by the Persyst P12 software, and compared to the raw EEG, interpreted by two experienced neurophysiologists; Positive percent agreement (PPA) and false-positive rates/hour (FPR) were calculated. RESULTS: We assessed 98 recordings (Group A=21 patients; B=29, C=17, D=31). Total duration was 82.7h (median: 1h); containing 268 seizures. The software detected 204 (=76.1%) seizures; all ictal events were captured in 29/38 (76.3%) patients; in only in 3 (7.7%) no seizures were detected. Median PPA was 100% (range 0-100; interquartile range 50-100), and the median FPR 0/h (range 0-75.8; interquartile range 0-4.5); however, lower performances were seen in the groups containing periodic discharges. CONCLUSION: This analysis provides data regarding the yield of the ASD in a particularly difficult subset of EEG recordings, showing that periodic discharges may bias the results. SIGNIFICANCE: Ongoing refinements in this technique might enhance its utility and lead to a more extensive application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: infants hospitalised in neonatology are inevitably exposed to pain repeatedly. Premature infants are particularly vulnerable, because they are hypersensitive to pain and demonstrate diminished behavioural responses to pain. They are therefore at risk of developing short and long-term complications if pain remains untreated. CONTEXT: compared to acute pain, there is limited evidence in the literature on prolonged pain in infants. However, the prevalence is reported between 20 and 40 %. OBJECTIVE : this single case study aimed to identify the bio-contextual characteristics of neonates who experienced prolonged pain. METHODS : this study was carried out in the neonatal unit of a tertiary referral centre in Western Switzerland. A retrospective data analysis of seven infants' profile, who experienced prolonged pain ,was performed using five different data sources. RESULTS : the mean gestational age of the seven infants was 32weeks. The main diagnosis included prematurity and respiratory distress syndrome. The total observations (N=55) showed that the participants had in average 21.8 (SD 6.9) painful procedures that were estimated to be of moderate to severe intensity each day. Out of the 164 recorded pain scores (2.9 pain assessment/day/infant), 14.6 % confirmed acute pain. Out of those experiencing acute pain, analgesia was given in 16.6 % of them and 79.1 % received no analgesia. CONCLUSION: this study highlighted the difficulty in managing pain in neonates who are exposed to numerous painful procedures. Pain in this population remains underevaluated and as a result undertreated.Results of this study showed that nursing documentation related to pain assessment is not systematic.Regular assessment and documentation of acute and prolonged pain are recommended. This could be achieved with clear guidelines on the Assessment Intervention Reassessment (AIR) cyclewith validated measures adapted to neonates. The adequacy of pain assessment is a pre-requisite for appropriate pain relief in neonates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les maladies cardio-vasculaires représentent la première cause de mortalité en Suisse. Après un arrêt cardio-respiratoire, une minorité des patients survit sans ou avec peu de séquelles fonctionnelles. L'évaluation du pronostic se fait classiquement selon des critères établis par l'Académie Américaine de Neurologie (AAN) en 2006, soit précédant l'introduction de l'hypothermie thérapeutique. Depuis, ces critères semblent insuffisants, et de nouveaux examens para-cliniques sont nécessaires afin d'identifier les patients ayant un pronostic favorable. La détection d'irrégularités auditives, et plus particulièrement l'évolution de cette détection sur plusieurs jours, pourrait être un indicateur du pronostic de patients comateux suite à une anoxie cérébrale. En effet, lors d'une violation de la régularité établie par des séries de sons identiques, deux signaux sont détectables à l'électro- encéphalographie (EEG). Le premier, dénommé «Mismatch negativity» (MMN), peut être enregistré après une violation locale d'une régularité établie au niveau de chaque son. Il reflète un processus inconscient et ne demandant pas de ressources attentionnelles. Le deuxième, dénommé « complexe P300 » survient par contre après une violation globale d'une régularité établie au niveau de groupes de sons. La littérature actuelle indique que ce deuxième phénomène requerrait la présence de capacités attentionnelles. Dans notre étude, nous avons testé l'existence de cette détection d'irrégularités auditives globales chez des patients dans une phase précoce de coma post-anoxique, sous hypothermie thérapeutique. Nous avons enregistré la réponse électro-encéphalographique lors de violations de régularités auditives globales, à l'aide d'un protocole expérimental qui intégrait en plus un paradigme de MMN classique, afin de tester la détection d'irrégularités auditives locales également. Notre analyse finale inclut 24 patients comateux ayant subi un arrêt cardio-respiratoire, et bénéficié du protocole hypothermie du Centre Hospitalier Universitaire Vaudois (CHUV) à Lausanne. Après une analyse multivariée des réponses électro-encéphalographiques de chaque tracé individuellement (« single-trial »), nous avons trouvé que 8 patients sur 24 pouvaient discriminer une irrégularité globale, alors qu'étant définis comateux selon l'échelle de Glasgow (GCS). De plus, l'amélioration de la détection d' irrégularités auditives entre deux EEG consécutifs (en hypo- puis normothermie), était un facteur de bon pronostic. Notre test pourrait ainsi être un complément para-clinique dans l'évaluation du pronostic de patients en coma post- anoxique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diagnosis of several neurological disorders is based on the detection of typical pathological patterns in the electroencephalogram (EEG). This is a time-consuming task requiring significant training and experience. Automatic detection of these EEG patterns would greatly assist in quantitative analysis and interpretation. We present a method, which allows automatic detection of epileptiform events and discrimination of them from eye blinks, and is based on features derived using a novel application of independent component analysis. The algorithm was trained and cross validated using seven EEGs with epileptiform activity. For epileptiform events with compensation for eyeblinks, the sensitivity was 65 +/- 22% at a specificity of 86 +/- 7% (mean +/- SD). With feature extraction by PCA or classification of raw data, specificity reduced to 76 and 74%, respectively, for the same sensitivity. On exactly the same data, the commercially available software Reveal had a maximum sensitivity of 30% and concurrent specificity of 77%. Our algorithm performed well at detecting epileptiform events in this preliminary test and offers a flexible tool that is intended to be generalized to the simultaneous classification of many waveforms in the EEG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visual analysis of electroencephalography (EEG) background and reactivity during therapeutic hypothermia provides important outcome information, but is time-consuming and not always consistent between reviewers. Automated EEG analysis may help quantify the brain damage. Forty-six comatose patients in therapeutic hypothermia, after cardiac arrest, were included in the study. EEG background was quantified with burst-suppression ratio (BSR) and approximate entropy, both used to monitor anesthesia. Reactivity was detected through change in the power spectrum of signal before and after stimulation. Automatic results obtained almost perfect agreement (discontinuity) to substantial agreement (background reactivity) with a visual score from EEG-certified neurologists. Burst-suppression ratio was more suited to distinguish continuous EEG background from burst-suppression than approximate entropy in this specific population. Automatic EEG background and reactivity measures were significantly related to good and poor outcome. We conclude that quantitative EEG measurements can provide promising information regarding current state of the patient and clinical outcome, but further work is needed before routine application in a clinical setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glutathione (GSH) dysregulation at the gene, protein, and functional levels has been observed in schizophrenia patients. Together with disease-like anomalies in GSH deficit experimental models, it suggests that such redox dysregulation can play a critical role in altering neural connectivity and synchronization, and thus possibly causing schizophrenia symptoms. To determine whether increased GSH levels would modulate EEG synchronization, N-acetyl-cysteine (NAC), a glutathione precursor, was administered to patients in a randomized, double-blind, crossover protocol for 60 days, followed by placebo for another 60 days (or vice versa). We analyzed whole-head topography of the multivariate phase synchronization (MPS) for 128-channel resting-state EEGs that were recorded at the onset, at the point of crossover, and at the end of the protocol. In this proof of concept study, the treatment with NAC significantly increased MPS compared to placebo over the left parieto-temporal, the right temporal, and the bilateral prefrontal regions. These changes were robust both at the group and at the individual level. Although MPS increase was observed in the absence of clinical improvement at a group level, it correlated with individual change estimated by Liddle's disorganization scale. Therefore, significant changes in EEG synchronization induced by NAC administration may precede clinically detectable improvement, highlighting its possible utility as a biomarker of treatment efficacy. TRIAL REGISTRATION: ClinicalTrials.gov NCT01506765.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neuronal oscillations are an important aspect of EEG recordings. These oscillations are supposed to be involved in several cognitive mechanisms. For instance, oscillatory activity is considered a key component for the top-down control of perception. However, measuring this activity and its influence requires precise extraction of frequency components. This processing is not straightforward. Particularly, difficulties with extracting oscillations arise due to their time-varying characteristics. Moreover, when phase information is needed, it is of the utmost importance to extract narrow-band signals. This paper presents a novel method using adaptive filters for tracking and extracting these time-varying oscillations. This scheme is designed to maximize the oscillatory behavior at the output of the adaptive filter. It is then capable of tracking an oscillation and describing its temporal evolution even during low amplitude time segments. Moreover, this method can be extended in order to track several oscillations simultaneously and to use multiple signals. These two extensions are particularly relevant in the framework of EEG data processing, where oscillations are active at the same time in different frequency bands and signals are recorded with multiple sensors. The presented tracking scheme is first tested with synthetic signals in order to highlight its capabilities. Then it is applied to data recorded during a visual shape discrimination experiment for assessing its usefulness during EEG processing and in detecting functionally relevant changes. This method is an interesting additional processing step for providing alternative information compared to classical time-frequency analyses and for improving the detection and analysis of cross-frequency couplings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Functional connectivity in human brain can be represented as a network using electroencephalography (EEG) signals. These networks--whose nodes can vary from tens to hundreds--are characterized by neurobiologically meaningful graph theory metrics. This study investigates the degree to which various graph metrics depend upon the network size. To this end, EEGs from 32 normal subjects were recorded and functional networks of three different sizes were extracted. A state-space based method was used to calculate cross-correlation matrices between different brain regions. These correlation matrices were used to construct binary adjacency connectomes, which were assessed with regards to a number of graph metrics such as clustering coefficient, modularity, efficiency, economic efficiency, and assortativity. We showed that the estimates of these metrics significantly differ depending on the network size. Larger networks had higher efficiency, higher assortativity and lower modularity compared to those with smaller size and the same density. These findings indicate that the network size should be considered in any comparison of networks across studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synchronization behavior of electroencephalographic (EEG) signals is important for decoding information processing in the human brain. Modern multichannel EEG allows a transition from traditional measurements of synchronization in pairs of EEG signals to whole-brain synchronization maps. The latter can be based on bivariate measures (BM) via averaging over pair-wise values or, alternatively, on multivariate measures (MM), which directly ascribe a single value to the synchronization in a group. In order to compare BM versus MM, we applied nine different estimators to simulated multivariate time series with known parameters and to real EEGs.We found widespread correlations between BM and MM, which were almost frequency-independent for all the measures except coherence. The analysis of the behavior of synchronization measures in simulated settings with variable coupling strength, connection probability, and parameter mismatch showed that some of them, including S-estimator, S-Renyi, omega, and coherence, aremore sensitive to linear interdependences,while others, like mutual information and phase locking value, are more responsive to nonlinear effects. Onemust consider these properties together with the fact thatMM are computationally less expensive and, therefore, more efficient for the large-scale data sets than BM while choosing a synchronization measure for EEG analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel approach for analyzing single-trial electroencephalography (EEG) data, using topographic information. The method allows for visualizing event-related potentials using all the electrodes of recordings overcoming the problem of previous approaches that required electrode selection and waveforms filtering. We apply this method to EEG data from an auditory object recognition experiment that we have previously analyzed at an ERP level. Temporally structured periods were statistically identified wherein a given topography predominated without any prior information about the temporal behavior. In addition to providing novel methods for EEG analysis, the data indicate that ERPs are reliably observable at a single-trial level when examined topographically.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The age-related increase in interference susceptibility has been well documented and largely attributed to a deficit in inhibition. In the present study, event-related potentials were used to investigate EEG correlates of inhibitory processing in an interference "Arrow" task. A specific interest was addressed to theN2 and P3 components that respectively refers to conflict monitoring and to efficiency of inhibition processes (Anguera et al,. 2011). Younger (N=10, Mage=24.6) and older (N=10, Mage=65.5) participants were invited to perform a task consisting in deciding, as fast and accurately as possible, whether an arrow presented on a computer screen points to the left or the right, irrespective of its position on the screen (left, middle or right). Responses were provided by key-presses using the left and right indexes. Three conditions were considered: congruent (arrow pointing to the same direction as that of the side of the screen on which it appears), incongruent (arrow pointing to the opposite direction), and neutral (arrow presented at the center of the screen). A total of 56 trials per conditions were performed. Behaviorally, the results showed that in the incongruent condition the percent of correct responses significantly decreased in both groups. After adjustment with simple RT (additional control task), the increased RTs obtained in the old group were significantly more pronounced in the incongruent condition. With respect to electrophysiological data, results showed that frontal site (Fz), the N2 amplitude was significantly larger for the younger as compared to the older (- 2.55 μV vs. -0.62 μV respectively) whatever the condition. At central site (Cz), the P3 amplitude significantly decreased in the older compared to the younger in the incongruent condition only. Our findings suggest that the increased RTs observed in older participants during the incongruent condition is more specifically linked to late cognitive resources involved in inhibiting prepotent response tendencies rather than associated with earlier stages of treatment dedicated to conflict monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to propose a methodology allowing a detailed characterization of body sit-to-stand/stand-to-sit postural transition. Parameters characterizing the kinematics of the trunk movement during sit-to-stand (Si-St) postural transition were calculated using one initial sensor system fixed on the trunk and a data logger. Dynamic complexity of these postural transitions was estimated by fractal dimension of acceleration-angular velocity plot. We concluded that this method provides a simple and accurate tool for monitoring frail elderly and to objectively evaluate the efficacy of a rehabilitation program.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new quantitative approach of the mandibular sexual dimorphism, based on computer-aided image analysis and elliptical Fourier analysis of the mandibular outline in lateral view is presented. This method was applied to a series of 117 dentulous mandibles from 69 male and 48 female individuals native of Rhenish countries. Statistical discriminant analysis of the elliptical Fourier harmonics allowed the demonstration of a significant sexual dimorphism in 97.1% of males and 91.7% of females, i.e. in a higher proportion than in previous studies using classical metrical approaches. This original method opens interesting perspectives for increasing the accuracy of sex identification in current anthropological practice and in forensic procedures.