123 resultados para Neonatal care

em Université de Lausanne, Switzerland


Relevância:

80.00% 80.00%

Publicador:

Resumo:

There are growing concerns on long-term health consequences, notably on fertility rates, of plasticizers such as phthalates. While di(2-ethylhexyl)phthalate (DEHP) is currently used in several medical devices, newborns in the neonatal intensive care unit are both more exposed and more vulnerable to DEHP. The objectives of this study were to identify, count, and describe possible sources of DEHP in a neonatal care unit. Our method consisted in the listing and the inspection of the information on packaging, complemented by contact with manufacturers when necessary. According to the results, 6% of all products and 10% of plastic products contained some DEHP; 71% of these involved respiratory support devices. A vast majority of the items showed no information on the content of DEHP. Further research is needed, particularly to determine the effects of such an early exposure and to study and develop safer alternatives.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Minimally invasive surgery (MIS) for late-presenting congenital diaphragmatic hernia (CDH) has been described previously, but few neonatal cases of CDH have been reported. This study aimed to report the multicenter experience of these rare cases and to compare the laparoscopic and thoracoscopic approaches. METHODS: Using MIS procedures, 30 patients (16 boys and 14 girls) from nine centers underwent surgery for CDH within the first month of life, 26 before day 5. Only one patient had associated malformations. There were 10 preterm patients (32-36 weeks of gestational age). Their weight at birth ranged from 1,800 to 3,800 g, with three patients weighing less than 2,600 g. Of the 30 patients, 18 were intubated at birth. RESULTS: The MIS procedures were performed in 18 cases by a thoracoscopic approach and in 12 cases by a laparoscopic approach. No severe complication was observed. For 20 patients, reduction of the intrathoracic contents was achieved easily with 15 thoracoscopies and 5 laparoscopies. In six cases, the reduction was difficult, proving to be impossible for the four remaining patients: one treated with thoracoscopy and three with laparoscopy. The reasons for the inability to reduce the thoracic contents were difficulty of liver mobilization (1 left CDH and 2 right CDH) and the presence of a dilated stomach in the thorax. Reductions were easier for cases of wide diaphragmatic defects using thoracoscopy. There were 10 conversions (5 laparoscopies and 5 thoracoscopies). The reported reasons for conversion were inability to reduce (n = 4), need for a patch (n = 5), lack of adequate vision (n = 4), narrow working space (n = 1), associated bowel malrotation (n = 1), and an anesthetic problem (n = 1). Five defects were too large for direct closure and had to be closed with a patch. Four required conversion, with one performed through video-assisted thoracic surgery. The recurrences were detected after two primer thoracoscopic closures, one of which was managed by successful reoperation using thoracoscopy. CONCLUSIONS: In the neonatal period, CDH can be safely closed using MIS procedures. The overall success rate in this study was 67%. The indication for MIS is not related to weeks of gestational age, to weight at birth (if >2,600 g), or to the extent of the immediate neonatal care. Patients with no associated anomaly who are hemodynamically stabilized can benefit from MIS procedures. Reduction of the herniated organs is easier using thoracoscopy. Right CDH, liver lobe herniation, and the need for a patch closure are the most frequent reasons for conversion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Preterm children born before 32 weeks of gestation represent 1% of the annual births in Switzerland, and are the most at risk of neurodevelopmental disabilities. A neurological surveillance is thus implemented in the neonatal units, and multidisciplinary neurodevelopmental follow-up is offered to all our preterm patients. The follow-up clinics of the University hospitals in Lausanne and Geneva follow the Swiss guidelines for follow-up. An extended history and neurological examination is taken at each appointment, and a standardized test of development is performed. These examinations, which take place between the ages of 3 months and 9 years old, allow the early identification and treatment of developmental disorders frequent in this population, such as motor, cognitive or behavioral disorders, as well as the monitoring of the quality of neonatal care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE. Data on human natality, stillbirth and perinatal mortality from Switzerland (1979-1987), available in four birthweight categories, are reexamined to assess any about-weekly (circaseptan) and changes in about-daily (circadian) patterns in central Europe over a century and a halfDESIGN. Retrospective analyses on archived data.SETTING. Federal Office of Statistics for Switzerland.RESULTS. In addition to prominent circadians, weekly patterns are also documented.CONCLUSION. Exogenous variations, prominent in early extrauterine life, such as changes of scheduling in obstetrics, may contribute to circadian and cireaseptan natality patterns. Information on these patterns serves in the optimization of neonatal care. Partly endogenous, partly physical environmental aspects, at least of about-weekly patterns, remain to be elucidated in series consisting exclusively of spontaneous parturitions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Gastroschisis is a congenital anomaly with increasing incidence, easy prenatal diagnosis and extremely variable postnatal outcomes. Our objective was to systematically review the evidence regarding the association between prenatal ultrasound signs (intraabdominal bowel dilatation [IABD], extraabdominal bowel dilatation, gastric dilatation [GD], bowel wall thickness, polyhydramnios, and small for gestational age) and perinatal outcomes in gastroschisis (bowel atresia, intra uterine death, neonatal death, time to full enteral feeding, length of total parenteral nutrition and length of in hospital stay). METHODS: Medline, Embase, and Cochrane databases were searched electronically. Studies exploring the association between antenatal ultrasound signs and outcomes in gastroschisis were considered suitable for inclusion. Two reviewers independently extracted relevant data regarding study characteristics and pregnancy outcome. All meta-analyses were computed using individual data random-effect logistic regression, with single study as the cluster unit. RESULTS: Twenty-six studies, including 2023 fetuses, were included. We found significant positive associations between IABD and bowel atresia (odds ratio [OR]: 5.48, 95% confidence interval [CI] 3.1-9.8), polyhydramnios and bowel atresia (OR: 3.76, 95% CI 1.7-8.3), and GD and neonatal death (OR: 5.58, 95% CI 1.3-24.1). No other ultrasound sign was significantly related to any other outcome. CONCLUSIONS: IABD, polyhydramnios, and GD can be used to an extent to identify a subgroup of neonates with a prenatal diagnosis of gastroschisis at higher risk to develop postnatal complications. Data are still inconclusive on the predictive ability of several signs combined, and large prospective studies are needed to improve the quality of prenatal counseling and the neonatal care for this condition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Preterm or sick neonates are frequently hampered in establishing a safe and efficient oral feeding. This can delay hospital discharge and impact on parent-child bonding, growth or neurodevelopment. Recent researches identified a pattern of interventions that could allow to reduce these troubles and to shorten hospital stays.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: Critical care is a working environment with frequent exposure to stressful events. High levels of psychological stress have been associated with increased prevalence of burnout. Psychological distress acts as a potent trigger of cortisol secretions. We attempted to objectify endocrine stress reactivity. DESIGN: Observational cohort study during two 12-day periods in successive years. SETTING: A tertiary multidisciplinary neonatal and pediatric intensive care unit (33 beds). SUBJECTS: One hundred and twelve nurses and 27 physicians (94% accrual rate). INTERVENTIONS AND MEASUREMENTS: Cortisol determined from salivary samples collected every 2 hrs and after stressful events. Participants recorded the subjective perception of stress with every sample. Endocrine reactions were defined as transient surges in cortisol of &gt;50% and 2.5 nmol/L over the baseline. MAIN RESULTS: During 7,145 working hours, we observed 474 (12.5%) endocrine reactions from 3,781 samples. The mean cortisol increase amounted to 10.6 nmol/L (219%). The mean occurrence rate of endocrine reactions per subject and sample was 0.159 (range, 0-0.43). Although the mean raw cortisol levels were lower in experienced team members (&gt;3 yrs of intensive care vs. &lt;3 yrs, 4.1 vs. 4.95 nmol/L, p &lt; .001), professional experience failed to attenuate the frequency and magnitude of endocrine reactions, except for the subgroup of nurses and physicians with &gt;8 yrs of intensive care experience. A high proportion (71.3%) of endocrine reactions occurred without conscious perception of stress. Unawareness of stress was higher in intensive care nurses (75.1%) than in intermediate care nurses (51.8%, p &lt; .01). CONCLUSIONS: Stress-related cortisol surges occur frequently in neonatal and pediatric critical care staff. Cortisol increases are independent of subjective stress perception. Professional experience does not abate the endocrine stress reactivity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Medication errors in hospitalsmay occur at any step of the medication process including prescription, transcription, preparation and administration, and may originate with any of the actors involved. Neonatal intensive care units (NICU) take care of extremely frail patients in whom errors could have dramatic consequences. Our objective was to assess the frequency and nature of medication errors in the NICU of a university hospital in order to propose measures for improvement.Materials & Methods The design was that of an observational prospective study over 4 consecutivemonths. All patients receiving C 3drugs were included. For each patient, observations during the different stages were compiled in a computer formulary and compared with the litterature. Setting: The 11-bed NICU of our university hospital.Main outcome measures:(a) Frequency and nature of medication errors in prescription,transcription, preparation and administration.(b) Drugs affected by errors.Results 83 patients were included. 505 prescriptions and transcriptions, 447 preparations and 464 administrations were analyzed. 220 medications errors were observed: 102 (46.4%) at prescription, 25 (11.4%) at transcription, 19 (8.6%) at preparation and 73 (33.2%) at administration. Uncomplete/ambiguous orders (24; 23.5%) were the most common errors observed at prescription, followed by wrong name (21; 20.6%), wrong dose (17; 16.7%) and omission (15; 14.7%). Wrong time (33; 45.2%) and wrong administration technique (31; 42.5%) were the most important medication errors during administration. According to the ATC classification, systemic antibacterials (53; 24.1%) were the most implicated, followed by perfusion solutions (40; 18.2%), respiratory system products (30; 13.6%), and mineral supplements and antithrombotic agents (20; 9.1%).Discussions, Conclusion Proposed recommendations: ? Better teaching of neonatal prescription to medical interns;? Improved prescription form to avoid omissions and ambiguities;? Development of a neonatal drug formulary, including prescription,preparation and administration modalities to reduce errors at different stages;? Presence of a clinical pharmacist in the NICU.Disclosure of Interest None Declared

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Skin-to-skin contact, or kangaroo mother care (KMC) has been shown to be efficacious in diminishing pain response to heel lance in full term and moderately preterm neonates. The purpose of this study was to determine if KMC would also be efficacious in very preterm neonates. METHODS: Preterm neonates (n = 61) between 28 0/7 and 31 6/7 weeks gestational age in three Level III NICU's in Canada comprised the sample. A single-blind randomized crossover design was employed. In the experimental condition, the infant was held in KMC for 15 minutes prior to and throughout heel lance procedure. In the control condition, the infant was in prone position swaddled in a blanket in the incubator. The primary outcome was the Premature Infant Pain Profile (PIPP), which is comprised of three facial actions, maximum heart rate, minimum oxygen saturation levels from baseline in 30-second blocks from heel lance. The secondary outcome was time to recover, defined as heart rate return to baseline. Continuous video, heart rate and oxygen saturation monitoring were recorded with event markers during the procedure and were subsequently analyzed. Repeated measures analysis-of-variance was employed to generate results. RESULTS: PIPP scores at 90 seconds post lance were significantly lower in the KMC condition (8.871 (95%CI 7.852-9.889) versus 10.677 (95%CI 9.563-11.792) p < .001) and non-significant mean differences ranging from 1.2 to1.8. favoring KMC condition at 30, 60 and 120 seconds. Time to recovery was significantly shorter, by a minute(123 seconds (95%CI 103-142) versus 193 seconds (95%CI 158-227). Facial actions were highly significantly lower across all points in time reaching a two-fold difference by 120 seconds post-lance and heart rate was significantly lower across the first 90 seconds in the KMC condition. CONCLUSION: Very preterm neonates appear to have endogenous mechanisms elicited through skin-to-skin maternal contact that decrease pain response, but not as powerfully as in older preterm neonates. The shorter recovery time in KMC is clinically important in helping maintain homeostasis. TRIAL REGISTRATION: (Current Controlled Trials) ISRCTN63551708.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Perinatal care of pregnant women at high risk for preterm delivery and of preterm infants born at the limit of viability (22-26 completed weeks of gestation) requires a multidisciplinary approach by an experienced perinatal team. Limited precision in the determination of both gestational age and foetal weight, as well as biological variability may significantly affect the course of action chosen in individual cases. The decisions that must be taken with the pregnant women and on behalf of the preterm infant in this context are complex and have far-reaching consequences. When counselling pregnant women and their partners, neonatologists and obstetricians should provide them with comprehensive information in a sensitive and supportive way to build a basis of trust. The decisions are developed in a continuing dialogue between all parties involved (physicians, midwives, nursing staff and parents) with the principal aim to find solutions that are in the infant's and pregnant woman's best interest. Knowledge of current gestational age-specific mortality and morbidity rates and how they are modified by prenatally known prognostic factors (estimated foetal weight, sex, exposure or nonexposure to antenatal corticosteroids, single or multiple births) as well as the application of accepted ethical principles form the basis for responsible decision-making. Communication between all parties involved plays a central role. The members of the interdisciplinary working group suggest that the care of preterm infants with a gestational age between 22 0/7 and 23 6/7 weeks should generally be limited to palliative care. Obstetric interventions for foetal indications such as Caesarean section delivery are usually not indicated. In selected cases, for example, after 23 weeks of pregnancy have been completed and several of the above mentioned prenatally known prognostic factors are favourable or well informed parents insist on the initiation of life-sustaining therapies, active obstetric interventions for foetal indications and provisional intensive care of the neonate may be reasonable. In preterm infants with a gestational age between 24 0/7 and 24 6/7 weeks, it can be difficult to determine whether the burden of obstetric interventions and neonatal intensive care is justified given the limited chances of success of such a therapy. In such cases, the individual constellation of prenatally known factors which impact on prognosis can be helpful in the decision making process with the parents. In preterm infants with a gestational age between 25 0/7 and 25 6/7 weeks, foetal surveillance, obstetric interventions for foetal indications and neonatal intensive care measures are generally indicated. However, if several prenatally known prognostic factors are unfavourable and the parents agree, primary non-intervention and neonatal palliative care can be considered. All pregnant women with threatening preterm delivery or premature rupture of membranes at the limit of viability must be transferred to a perinatal centre with a level III neonatal intensive care unit no later than 23 0/7 weeks of gestation, unless emergency delivery is indicated. An experienced neonatology team should be involved in all deliveries that take place after 23 0/7 weeks of gestation to help to decide together with the parents if the initiation of intensive care measures appears to be appropriate or if preference should be given to palliative care (i.e., primary non-intervention). In doubtful situations, it can be reasonable to initiate intensive care and to admit the preterm infant to a neonatal intensive care unit (i.e., provisional intensive care). The infant's clinical evolution and additional discussions with the parents will help to clarify whether the life-sustaining therapies should be continued or withdrawn. Life support is continued as long as there is reasonable hope for survival and the infant's burden of intensive care is acceptable. If, on the other hand, the health care team and the parents have to recognise that in the light of a very poor prognosis the burden of the currently used therapies has become disproportionate, intensive care measures are no longer justified and other aspects of care (e.g., relief of pain and suffering) are the new priorities (i.e., redirection of care). If a decision is made to withhold or withdraw life-sustaining therapies, the health care team should focus on comfort care for the dying infant and support for the parents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a review of different methods enabling the monitoring of cerebral function in neonatal and paediatric intensive care. EEG, evoked potentials, conventional radiological studies, computerized tomography, ultrasound, intracranial pressure measurements, nuclear magnetic resonance, Doppler ultrasound, radioisotope studies, angiography, infra-red spectral analysis and last, but not least, clinical examination produce information regarding the neurological state of the patient which must be critically analysed in order to ensure optimal management of the case. Unfortunately, and in spite of impressive progress in non-invasive monitoring of the cerebral function, we are still forced to make important medical and ethical decisions without precise information about the neurological state of our patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Minimizing unwarranted prescription of antibiotics remains an important objective. Because of the heterogeneity between units regarding patient mix and other characteristics, site-specific targets for reduction must be identified. Here we present a model to address the issue by means of an observational cohort study. SETTING: A tertiary, multidisciplinary, neonatal, and pediatric intensive care unit of a university teaching hospital. PATIENTS: All newborns and children present in the unit (n = 456) between September 1998 and March 1999. Reasons for admission included postoperative care after cardiac surgery, major neonatal or pediatric surgery, severe trauma, and medical conditions requiring critical care. METHODS: Daily recording of antibiotics given and of indications for initiation. After discontinuation, each treatment episode was assessed as to the presence or absence of infection. RESULTS: Of the 456 patients 258 (56.6%) received systemic antibiotics, amounting to 1815 exposure days (54.6%) during 3322 hospitalization days. Of these, 512 (28%) were prescribed as prophylaxis and 1303 for suspected infection. Treatment for suspected ventilator-associated pneumonia accounted for 616 (47%) of 1303 treatment days and suspected sepsis for 255 days (20%). Patients were classified as having no infection or viral infection during 552 (40%) treatment days. The average weekly exposure rate in the unit varied considerably during the 29-week study period (range: 40-77/100 hospitalization days). Patient characteristics did not explain this variation. CONCLUSION: In this unit the largest reduction in antibiotic treatment would result from measures assisting suspected ventilator-associated pneumonia to be ruled out and from curtailing extended prophylaxis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. METHODS: PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. RESULTS: Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. CONCLUSIONS: No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks. These findings emphasize the need to improve algorithms for assisted ventilation modes to better deal with situations of high airway resistance, low pulmonary compliance, and the presence of leaks.