48 resultados para National Measurement System for Time and Frequency.
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND AND AIMS: Evidence-based and reliable measures of addictive disorders are needed in general population-based assessments. One study suggested that heavy use over time (UOT) should be used instead of self-reported addiction scales (AS). This study compared UOT and AS regarding video gaming and internet use empirically, using associations with comorbid factors. DESIGN: Cross-sectional data from the 2011 French Survey on Health and Consumption on Call-up and Preparation for Defence-Day (ESCAPAD), cross-sectional data from the 2012 Swiss ado@internet.ch study and two waves of longitudinal data (2010-13) of the Swiss Longitudinal Cohort Study on Substance Use Risk Factors (C-SURF). SETTING: Three representative samples from the general population of French and Swiss adolescents and young Swiss men, aged approximately 17, 14 and 20 years, respectively. PARTICIPANTS: ESCAPAD: n =22 945 (47.4% men); ado@internet.ch: n =3049 (50% men); C-SURF: n =4813 (baseline + follow-up, 100% men). MEASUREMENTS: We assessed video gaming/internet UOT ESCAPAD and ado@internet.ch: number of hours spent online per week, C-SURF: latent score of time spent gaming/using internet] and AS (ESCAPAD: Problematic Internet Use Questionnaire, ado@internet.ch: Internet Addiction Test, C-SURF: Gaming AS). Comorbidities were assessed with health outcomes (ESCAPAD: physical health evaluation with a single item, suicidal thoughts, and appointment with a psychiatrist; ado@internet.ch: WHO-5 and somatic health problems; C-SURF: Short Form 12 (SF-12 Health Survey) and Major Depression Inventory (MDI). FINDINGS: UOT and AS were correlated moderately (ESCAPAD: r = 0.40, ado@internet.ch: r = 0.53 and C-SURF: r = 0.51). Associations of AS with comorbidity factors were higher than those of UOT in cross-sectional (AS: .005 ≤ |b| ≤ 2.500, UOT: 0.001 ≤ |b| ≤ 1.000) and longitudinal analyses (AS: 0.093 ≤ |b| ≤ 1.079, UOT: 0.020 ≤ |b| ≤ 0.329). The results were similar across gender in ESCAPAD and ado@internet.ch (men: AS: 0.006 ≤ |b| ≤ 0.211, UOT: 0.001 ≤ |b| ≤ 0.061; women: AS: 0.004 ≤ |b| ≤ 0.155, UOT: 0.001 ≤ |b| ≤ 0.094). CONCLUSIONS: The measurement of heavy use over time captures part of addictive video gaming/internet use without overlapping to a large extent with the results of measuring by self-reported addiction scales (AS). Measuring addictive video gaming/internet use via self-reported addiction scales relates more strongly to comorbidity factors than heavy use over time.
Resumo:
BACKGROUND: Measuring syringe availability and coverage is essential in the assessment of HIV/AIDS risk reduction policies. Estimates of syringe availability and coverage were produced for the years 1996 and 2006, based on all relevant available national-level aggregated data from published sources. METHODS: We defined availability as the total monthly number of syringes provided by harm reduction system divided by the estimated number of injecting drug users (IDU), and defined coverage as the proportion of injections performed with a new syringe, at national level (total supply over total demand). Estimates of supply of syringes were derived from the national monitoring system, including needle and syringe programmes (NSP), pharmacies, and medically prescribed heroin programmes. Estimates of syringe demand were based on the number of injections performed by IDU derived from surveys of low threshold facilities for drug users (LTF) with NSP combined with the number of IDU. This number was estimated by two methods combining estimates of heroin users (multiple estimation method) and (a) the number of IDU in methadone treatment (MT) (non-injectors) or (b) the proportion of injectors amongst LTF attendees. Central estimates and ranges were obtained for availability and coverage. RESULTS: The estimated number of IDU decreased markedly according to both methods. The MT-based method (from 14,818 to 4809) showed a much greater decrease and smaller size of the IDU population compared to the LTF-based method (from 24,510 to 12,320). Availability and coverage estimates are higher with the MT-based method. For 1996, central estimates of syringe availability were 30.5 and 18.4 per IDU per month; for 2006, they were 76.5 and 29.9. There were 4 central estimates of coverage. For 1996 they ranged from 24.3% to 43.3%, and for 2006, from 50.5% to 134.3%. CONCLUSION: Although 2006 estimates overlap 1996 estimates, the results suggest a shift to improved syringe availability and coverage over time.
Resumo:
Purpose: The accurate estimation of total energy expenditure (TEE) is essential to allow the provision of nutritional requirements in patients treated by maintenance hemodialysis (MHD). The measurement of TEE and resting energy expenditure (REE) by direct or indirect calorimetry and doubly labeled water are complicated, timeconsuming and cumbersome in this population. Recently, a new system called SenseWear® armband (SWA) was developed to assess TEE, physical activity and REE. This device works by measurements of body acceleration in two axes, heat production and steps counts. REE measured by indirect calorimetry and SWA are well correlated. The aim of this study was to determine TEE, physical activity and REE on patients on MHD using this new device. Methods and materials: Daily TEE, REE, step count, activity time, intensity of activity and lying time were determined for 7 consecutive days in unselected stable patients on MHD and sex, age and weightmatched healthy controls (HC). Patients with malnutrition, cancer, use of immunosuppressive drugs, hypoalbumemia <35 g/L and those hospitalized in the last 3 months, were excluded. For MHD patients, separate analyses were conducted in dialysis and non-dialysis days. Relevant parameters known to affect REE, such as BMI, albumin, pre-albumin, hemoglobin, Kt/V, CRP, bicarbonate, PTH, TSH, were recorded. Results: Thirty patients on MHD and 30 HC were included. In MHD patients, there were 20 men and 10 women. Age was 60,13 years ± 14.97 (mean ± SD), BMI was 25.77 kg/m² ± 4.73 and body weight was 74.65 kg ± 16.16. There were no significant differences between the two groups. TEE was lower in MHD patients compared to HC (28.79 ± 5.51 SD versus 32.91 ± 5.75 SD kcal/kg/day; p <0.01). Activity time was significantly lower in patients on MHD (101.3 ± 12.6SD versus 50.7 ± 9.4 SD min; p = 0.0021). Energy expenditure during the time of activity was significantly lower in MHD patients. MHD patients walked 4543 ± 643 SD vs 8537 ± 744 SD steps per day (p <0.0001). Age was negatively correlated with TEE (r = -0.70) and intensity of activity (r = -0.61) in HC, but not in patients on MHD. TEE showed no difference between dialysis and non-dialysis days (29.92 ± 2.03 SD versus 28.44 ± 1.90 SD kcal/kg/day; p = NS), reflecting a lack of difference in activity (number of steps, time of physical activity) and REE. This finding was observed in MHD patients both older and younger than 60 years. However, age stratification appeared to have an influence on TEE, regardless of dialysis day, (29.92 ± 2.07 SD kcal/kg/day for <60 years-old versus 27.41 ± 1.04 SD kcal/kg/day for ≥60 years old), although failing to reach statistical significance. Conclusion: Using SWA, we have shown that stable patients on MHD have a lower TEE than matched HC. On average, a TEE of 28.79 kcal/kg/day, partially affected by age, was measured. This finding gives support to the clinical impression that it is difficult and probably unnecessary to provide an energy amount of 30-35 kcal/kg/day, as proposed by international guidelines for this population. In addition, we documented for the first time that MHD patients exert a reduced physical activity as compared to HC. There were surprisingly no differences in TEE, REE and physical activity parameters between dialysis and non-dialysis days. This observation might be due to the fact that patients on MHD produce a physical effort to reach the dialysis centre. Age per se did not influence physical activity in MHD patients, contrary to HC, reflecting the impact of co-morbidities on physical activity in this group of patients.
Resumo:
INTRODUCTION: In alpine skiing, chronometry analysis is currently the most common tool to assess performance. It is widely used to rank competitors during races, as well as to manage athletes training and to evaluate material. Usually, this measurement is accurately realized using timing cells. Nevertheless, these devices are too complex and expensive to allow chronometry of every gates crossing. On the other side, differential GPS can be used for measuring gate crossing time (Waegli et al). However, this is complex (e.g. recording gate position with GPS) and mainly used in research applications. The aim of the study was to propose a wearable system to time gates crossing during alpine skiing slalom (SL), which is suitable for routine uses. METHODS: The proposed system was composed of a 3D accelerometer (ADXL320®, Analog Device, USA) placed at the sacrum of the athlete, a matrix of force sensors (Flexiforce®, Tekscan, USA) fixed on the right shin guard and a data logger (Physilog®, BioAGM, Switzerland). The sensors were sampled at 500 Hz. The crossing time were calculated in two phases. First, the accelerometer was used to detect the curves by considering the maximum of the mediolateral peak acceleration. Then, the force sensors were used to detect the impacts with the gates by considering maximum force variation. In case of non impact, the detection was realized based on the acceleration and features measured at the other gates. In order to assess the efficiency of the system, two different SL were monitored twice for two world cup level skiers, a male SL expert and a female downhill expert. RESULTS AND DISCUSSION: The combination of the accelerometer and force sensors allowed to clearly identify the gate crossing times. When comparing the runs of the SL expert and the downhill expert, we noticed that the SL expert was faster. For example for the first SL, the overall difference between the best run of each athlete was of 5.47s. At each gate, the SL expert increased the time difference slower at the beginning (0.27s/gate) than at the end (0.34s/gate). Furthermore, when comparing the runs of the SL expert, a maximum time difference of 20ms at each gate was noticed. This showed high repeatability skills of the SL expert. In opposite, the downhill expert with a maximum difference time of 1s at each gate was clearly less repeatable. Both skiers were not disturbed by the system. CONCLUSION: This study proposed a new wearable system to automatically time gates crossing during alpine skiing slalom combining force and accelerometer sensors. The system was evaluated with two professional world cup skiers and showed a high potential. This system could be extended to time other parameters. REFERENCES Waegli A, Skaloud J (2007). Inside GNSS, Spring, 24-34.
Resumo:
The mouse has emerged as an animal model for many diseases. At IRO, we have used this animal to understand the development of many eye diseases and treatment of some of them. Precise evaluation of vision is a prerequisite for both these approaches. In this unit we describe three ways to measure vision: testing the optokinetic response, and evaluating the fundus by direct observation and by fluorescent angiography.
Resumo:
The human auditory system is comprised of specialized but interacting anatomic and functional pathways encoding object, spatial, and temporal information. We review how learning-induced plasticity manifests along these pathways and to what extent there are common mechanisms subserving such plasticity. A first series of experiments establishes a temporal hierarchy along which sounds of objects are discriminated along basic to fine-grained categorical boundaries and learned representations. A widespread network of temporal and (pre)frontal brain regions contributes to object discrimination via recursive processing. Learning-induced plasticity typically manifested as repetition suppression within a common set of brain regions. A second series considered how the temporal sequence of sound sources is represented. We show that lateralized responsiveness during the initial encoding phase of pairs of auditory spatial stimuli is critical for their accurate ordered perception. Finally, we consider how spatial representations are formed and modified through training-induced learning. A population-based model of spatial processing is supported wherein temporal and parietal structures interact in the encoding of relative and absolute spatial information over the initial ∼300ms post-stimulus onset. Collectively, these data provide insights into the functional organization of human audition and open directions for new developments in targeted diagnostic and neurorehabilitation strategies.
Resumo:
Several methods are available for coding body movement in nonverbal behavior research, but there is no consensus on a reliable coding system that can be used for the study of emotion expression. Adopting an integrative approach, we developed a new method, the Body Action and Posture (BAP) coding system, for the time-aligned micro description of body movement on an anatomical level (different articulations of body parts), a form level (direction and orientation of movement), and a functional level (communicative and self-regulatory functions). We applied the system to a new corpus of acted emotion portrayals, examined its comprehensiveness and demonstrated intercoder reliability at three levels: a) occurrence, b) temporal precision and c) segmentation. We discuss issues for further validation and propose some research applications.
Resumo:
To evaluate the severity of airway pathologies, quantitative dimensioning of airways is of utmost importance. Endoscopic vision gives a projective image and thus no true scaling information can be directly deduced from it. In this article, an approach based on an interferometric setup, a low-coherence laser source and a standard rigid endoscope is presented, and applied to hollow samples measurements. More generally, the use of the low-coherence interferometric setup detailed here could be extended to any other endoscopy-related field of interest, e.g., gastroscopy, arthroscopy and other medical or industrial applications where tri-dimensional topology is required. The setup design with a multiple fibers illumination system is presented. Demonstration of the method ability to operate on biological samples is assessed through measurements on ex vivo pig bronchi.
Resumo:
This paper identifies selected issues and lessons learned from the implementation of a national program of prevention and control of non-communicable diseases (NCD) during the past 20 years in the Seychelles, a small island state in the African region. As early as in 1989, population-based surveys demonstrated high levels of several cardiovascular risk factors, which prompted an organized response by the government. The early creation of a NCD unit within the Ministry of Health, coupled with cooperation with international partners, enabled incremental capacity building and coherent development of NCD programs and policy. Information campaigns and screening for hypertension and diabetes in work/public places raised awareness and rallied increasingly broad awareness and support to NCD prevention and control. A variety of interventions were organized for tobacco control and comprehensive tobacco control legislation was enacted in 2009 (including total bans on tobacco advertising and on smoking in all enclosed public and work places). A recent School Nutrition Policy prohibits the sale of soft drinks in schools. At primary health care level, guidelines were developed for the management of hypertension and diabetes (these conditions are managed in all health centers within a national health system); regular interactive education sessions were organized for groups of high risk patients ("heart health club"); and specialized "NCD nurses" were trained. Decreasing prevalence of smoking is evidence of success, but the raising "diabesity epidemic" calls for strengthened health care to high-risk patients and broader multisectoral policy to mould an environment conducive to healthy behaviors. Key components of NCD prevention and control in Seychelles include effective surveillance mechanisms supplemented by focused research; generating broad interest and consensus on the need for prevention and control of NCD; mobilizing leadership and commitment at all levels; involving local and international expertise; building on existing efforts; and seeking integrated, multi-disciplinary and multisectoral approaches.
Resumo:
BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed.¦METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy.¦RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months.¦CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.
Resumo:
BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed. METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy. RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months. CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.
Resumo:
Tumour immunologists strive to develop efficient tumour vaccination and adoptive transfer therapies that enlarge the pool of tumour-specific and -reactive effector T-cells in vivo. To assess the efficiency of the various strategies, ex vivo assays are needed for the longitudinal monitoring of the patient's specific immune responses providing both quantitative and qualitative data. In particular, since tumour cell cytolysis is the end goal of tumour immunotherapy, routine immune monitoring protocols need to include a read-out for the cytolytic efficiency of Ag-specific cells. We propose to combine current immune monitoring techniques in a highly sensitive and reproducible multi-parametric flow cytometry based cytotoxicity assay that has been optimised to require low numbers of Ag-specific T-cells. The possibility of re-analysing those T-cells that have undergone lytic activity is illustrated by the concomitant detection of CD107a upregulation on the surface of degranulated T-cells. To date, the LiveCount Assay provides the only possibility of assessing the ex vivo cytolytic activity of low-frequency Ag-specific cytotoxic T-lymphocytes from patient material.
Resumo:
In clinical settings, functional evaluation of shoulder movement is primarily based on what the patient thinks he/she is able to do rather than what he/she is actually performing. We proposed a new approach for shoulder assessment based on inertial sensors to monitor arm movement in the daily routine. The detection of movement of the humerus relative to the trunk was first validated in a laboratory setting (sensitivity>95%, specificity>97%). Then, 41 control subjects and 21 patients suffering from a rotator cuff tear were evaluated (before and after surgery) using clinical questionnaires and a one-day measurement of arm movement. The quantity of movement was estimated with the movement frequency and its symmetry index (SIFr). The quality of movement was assessed using the Kolmogorov-Smirnov distance (KS) between the cumulative distribution of the arm velocity for controls and the same distribution for each patient. SIFr presented differences between patients and controls at 3 month follow-up (p<0.05) while KS showed differences also after 6 months (p<0.01). SIFr illustrated a change in dominance due to the disorder whereas KS, which appeared independent of the dominance and occupation, showed a change in movement velocity. Both parameters were correlated to clinical scores (R(2) reaching 0.5). This approach provides clinicians with new objective parameters for evaluating the functional ability of the shoulder in daily conditions, which could be useful for outcome assessment after surgery.
Resumo:
The Learning Affect Monitor (LAM) is a new computer-based assessment system integrating basic dimensional evaluation and discrete description of affective states in daily life, based on an autonomous adapting system. Subjects evaluate their affective states according to a tridimensional space (valence and activation circumplex as well as global intensity) and then qualify it using up to 30 adjective descriptors chosen from a list. The system gradually adapts to the user, enabling the affect descriptors it presents to be increasingly relevant. An initial study with 51 subjects, using a 1 week time-sampling with 8 to 10 randomized signals per day, produced n = 2,813 records with good reliability measures (e.g., response rate of 88.8%, mean split-half reliability of .86), user acceptance, and usability. Multilevel analyses show circadian and hebdomadal patterns, and significant individual and situational variance components of the basic dimension evaluations. Validity analyses indicate sound assignment of qualitative affect descriptors in the bidimensional semantic space according to the circumplex model of basic affect dimensions. The LAM assessment module can be implemented on different platforms (palm, desk, mobile phone) and provides very rapid and meaningful data collection, preserving complex and interindividually comparable information in the domain of emotion and well-being.