4 resultados para Nanoparticule d’or
em Université de Lausanne, Switzerland
Resumo:
Background: In 1989, we introduced a 1-stage procedure with orthotopic colonic transplants for esophageal stenosis. A pitfall of this procedure is frequent reflux and/or stasis in the transplants from the cologastric anastomosis. Since 1993, we have used a new antireflux wrap (ARW) using an anterior wrap technique similar to the Dor procedure but fixed to the right crus of the diaphragm.Purpose: The purpose of the study was to evaluate ARWs.Method: From 1993 to 2008, the records of 67 patients with an ARW were compared with 27 without ARW (either operated on before 1993 or ARW was not appropriate) after colonic transplant for caustic esophageal stenosis. Both groups otherwise underwent the same surgical procedure. Postoperative esophagograms done on postoperative day 10 were reviewed for the presence of gastrocolonic reflux and stasis in the transplant.Results: The reflux rate on the initial esophagogram was reduced from 48.1% to 7.5% using ARW. The incidence of reflux on later esophagograms was 40.0% with no ARW and 21.4% with ARW. The 25% long-term rate of stasis in the colonic transplant was not increased with ARW.Conclusions: A loose ARW in patients with colonic esophageal replacements reduces gastrocolic reflux without increasing the rate of stasis. In the long term, children adapt better to stasis than to reflux and are thus protected from occult inflammation.
Resumo:
INTRODUCTION: Timely diagnosis of invasive candidiasis (IC) remains difficult as the clinical presentation is not specific and blood cultures lack sensitivity and need a long incubation time. Thus, non-culture-based methods for diagnosing IC have been developed. Mannan antigen (Mn) and anti-mannan antibodies (A-Mn) are present in patients with IC. On behalf of the Third European Conference on Infections in Leukemia, the performance of these tests was analysed and reviewed. METHODS: The literature was searched for studies using the commercially available sandwich enzyme-linked immunosorbent assays (Platelia™, Bio-Rad Laboratories, Marnes-la-Coquette, France) for detecting Mn and A-Mn in serum. The target condition of this review was IC defined according to 2008 European Organization for Research and Treatment of Cancer/Mycoses Study Group criteria. Sensitivity, specificity and diagnostic odds ratios (DOR) were calculated for Mn, A-Mn and combined Mn/A-Mn testing. RESULTS: Overall, 14 studies that comprised 453 patients and 767 controls were reviewed. The patient populations included in the studies were mainly haematological and cancer cases in seven studies and mainly intensive care unit and surgery cases in the other seven studies. All studies but one were retrospective in design. Mn sensitivity was 58% (95% confidence interval [CI], 53-62); specificity, 93% (95% CI, 91-94) and DOR, 18 (95% CI 12-28). A-Mn sensitivity was 59% (95% CI, 54-65); specificity, 83% (95% CI, 79-97) and DOR, 12 (95% CI 7-21). Combined Mn/A-Mn sensitivity was 83% (95% CI, 79-87); specificity, 86% (95% CI, 82-90) and DOR, 58 (95% CI 27-122). Significant heterogeneity of the studies was detected. The sensitivity of both Mn and A-Mn varied for different Candida species, and it was the highest for C. albicans, followed by C. glabrata and C. tropicalis. In 73% of 45 patients with candidemia, at least one of the serological tests was positive before the culture results, with mean time advantage being 6 days for Mn and 7 days for A-Mn. In 21 patients with hepatosplenic IC, 18 (86%) had Mn or A-Mn positive test results at a median of 16 days before radiological detection of liver or spleen lesions. CONCLUSIONS: Mn and A-Mn are useful for diagnosis of IC. The performance of combined Mn/A-Mn testing is superior to either Mn or A-Mn testing.