55 resultados para Mobile bed
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND AND AIMS: In critically ill patients, fractional hepatic de novo lipogenesis increases in proportion to carbohydrate administration during isoenergetic nutrition. In this study, we sought to determine whether this increase may be the consequence of continuous enteral nutrition and bed rest. We, therefore, measured fractional hepatic de novo lipogenesis in a group of 12 healthy subjects during near-continuous oral feeding (hourly isoenergetic meals with a liquid formula containing 55% carbohydrate). In eight subjects, near-continuous enteral nutrition and bed rest were applied over a 10 h period. In the other four subjects, it was extended to 34 h. Fractional hepatic de novo lipogenesis was measured by infusing(13) C-labeled acetate and monitoring VLDL-(13)C palmitate enrichment with mass isotopomer distribution analysis. Fractional hepatic de novo lipogenesis was 3.2% (range 1.5-7.5%) in the eight subjects after 10 h of near continuous nutrition and 1.6% (range 1.3-2.0%) in the four subjects after 34 h of near-continuous nutrition and bed rest. This indicates that continuous nutrition and physical inactivity do not increase hepatic de novo lipogenesis. Fractional hepatic de novo lipogenesis previously reported in critically ill patients under similar nutritional conditions (9.3%) (range 5.3-15.8%) was markedly higher than in healthy subjects (P<0.001). These data from healthy subjects indicate that fractional hepatic de novo lipogenesis is increased in critically ill patients.
Resumo:
While mobile technologies can provide great personalized services for mobile users, they also threaten their privacy. Such personalization-privacy paradox are particularly salient for context aware technology based mobile applications where user's behaviors, movement and habits can be associated with a consumer's personal identity. In this thesis, I studied the privacy issues in the mobile context, particularly focus on an adaptive privacy management system design for context-aware mobile devices, and explore the role of personalization and control over user's personal data. This allowed me to make multiple contributions, both theoretical and practical. In the theoretical world, I propose and prototype an adaptive Single-Sign On solution that use user's context information to protect user's private information for smartphone. To validate this solution, I first proved that user's context is a unique user identifier and context awareness technology can increase user's perceived ease of use of the system and service provider's authentication security. I then followed a design science research paradigm and implemented this solution into a mobile application called "Privacy Manager". I evaluated the utility by several focus group interviews, and overall the proposed solution fulfilled the expected function and users expressed their intentions to use this application. To better understand the personalization-privacy paradox, I built on the theoretical foundations of privacy calculus and technology acceptance model to conceptualize the theory of users' mobile privacy management. I also examined the role of personalization and control ability on my model and how these two elements interact with privacy calculus and mobile technology model. In the practical realm, this thesis contributes to the understanding of the tradeoff between the benefit of personalized services and user's privacy concerns it may cause. By pointing out new opportunities to rethink how user's context information can protect private data, it also suggests new elements for privacy related business models.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
OBJECTIVE: The occurrence of the 2003 G8 summit in Evian and the threat of major civil riots or even terrorist attacks in the Swiss neighbourhood forced us to imagine a new system of rescue and medical care in case of numerous victims. Previous occurrences of the G8 in Europe or America have demonstrated the need of flexible and mobile structures, able to respond quickly to crowd movements, unlike the usual static structure of rescue systems designed for major accidents. METHODS: We developed a new concept of Mobile Medical Squadrons (MMS) consisting of several vehicles and medical care and rescue human resources. In our concept, each MMS consisted of 3 emergency doctors, 5 paramedics and 9 first-aid workers. They were designed to handle 15 patients, with a large autonomy in terms of rescue, medical care, evacuation and medical authority. The equipment included medical, resuscitation, simple decontamination, evacuation and communication materials. RESULTS: The MMS were dispatched four times during the G8 summit following civil riots. They took care of 12 injured patients. CONCLUSION: The concept of MMS as a reinforcement of the existing rescue and health care resources appears as a new flexible, a modular and useful concept for the medical management of collective prehospital emergency situations. Its use is suggested instead of the traditional static concept of rescue systems designed for major accidents.
Resumo:
Background: Integrative and conjugative elements (ICE) form a diverse group of DNA elements that are integrated in the chromosome of the bacterial host, but can occasionally excise and horizontally transfer to a new host cell. ICE come in different families, typically with a conserved core for functions controlling the element's behavior and a variable region providing auxiliary functions to the host. The ICEclc element of Pseudomonas knackmussii strain B13 is representative for a large family of chromosomal islands detected by genome sequencing approaches. It provides the host with the capacity to degrade chloroaromatics and 2-aminophenol. Results: Here we study the transcriptional organization of the ICEclc core region. By northern hybridizations, reverse-transcriptase polymerase chain reaction (RT-PCR) and Rapid Amplification of cDNA Ends (5'-RACE) fifteen transcripts were mapped in the core region. The occurrence and location of those transcripts were further confirmed by hybridizing labeled cDNA to a semi-tiling micro-array probing both strands of the ICEclc core region. Dot blot and semi-tiling array hybridizations demonstrated most of the core transcripts to be upregulated during stationary phase on 3-chlorobenzoate, but not on succinate or glucose. Conclusions: The transcription analysis of the ICEclc core region provides detailed insights in the mode of regulatory organization and will help to further understand the complex mode of behavior of this class of mobile elements. We conclude that ICEclc core transcription is concerted at a global level, more reminiscent of a phage program than of plasmid conjugation.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. This randomized controlled double-blind study included to date 14 patients: the gait signatures of four patients with mobile-bearing were compared to the gait signatures of nine patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
To date, state-of-the-art seismic material parameter estimates from multi-component sea-bed seismic data are based on the assumption that the sea-bed consists of a fully elastic half-space. In reality, however, the shallow sea-bed generally consists of soft, unconsolidated sediments that are characterized by strong to very strong seismic attenuation. To explore the potential implications, we apply a state-of-the-art elastic decomposition algorithm to synthetic data for a range of canonical sea-bed models consisting of a viscoelastic half-space of varying attenuation. We find that in the presence of strong seismic attenuation, as quantified by Q-values of 10 or less, significant errors arise in the conventional elastic estimation of seismic properties. Tests on synthetic data indicate that these errors can be largely avoided by accounting for the inherent attenuation of the seafloor when estimating the seismic parameters. This can be achieved by replacing the real-valued expressions for the elastic moduli in the governing equations in the parameter estimation by their complex-valued viscoelastic equivalents. The practical application of our parameter procedure yields realistic estimates of the elastic seismic material properties of the shallow sea-bed, while the corresponding Q-estimates seem to be biased towards too low values, particularly for S-waves. Given that the estimation of inelastic material parameters is notoriously difficult, particularly in the immediate vicinity of the sea-bed, this is expected to be of interest and importance for civil and ocean engineering purposes.
Resumo:
BACKGROUND: There is a growing use of mobile devices to access the Internet. We examined whether participants who used a mobile device to access a brief online survey were quicker to respond to the survey but also, less likely to complete it than participants using a traditional web browser. FINDINGS: Using data from a recently completed online intervention trial, we found that participants using mobile devices were quicker to access the survey but less likely to complete it compared to participants using a traditional web browser. More concerning, mobile device users were also less likely to respond to a request to complete a six week follow-up survey compared to those using traditional web browsers. CONCLUSIONS: With roughly a third of participants using mobile devices to answer an online survey in this study, the impact of mobile device usage on survey completion rates is a concern. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01521078.
Resumo:
The objective of this study was to determine the effect of once-yearly zoledronic acid on the number of days of back pain and the number of days of disability (ie, limited activity and bed rest) owing to back pain or fracture in postmenopausal women with osteoporosis. This was a multicenter, randomized, double-blind, placebo-controlled trial in 240 clinical centers in 27 countries. Participants included 7736 postmenopausal women with osteoporosis. Patients were randomized to receive either a single 15-minute intravenous infusion of zoledronic acid (5 mg) or placebo at baseline, 12 months, and 24 months. The main outcome measures were self-reported number of days with back pain and the number of days of limited activity and bed rest owing to back pain or a fracture, and this was assessed every 3 months over a 3-year period. Our results show that although the incidence of back pain was high in both randomized groups, women randomized to zoledronic acid experienced, on average, 18 fewer days of back pain compared with placebo over the course of the trial (p = .0092). The back pain among women randomized to zoledronic acid versus placebo resulted in 11 fewer days of limited activity (p = .0017). In Cox proportional-hazards models, women randomized to zoledronic acid were about 6% less likely to experience 7 or more days of back pain [relative risk (RR) = 0.94, 95% confidence interval (CI) 0.90-0.99] or limited activity owing to back pain (RR = 0.94, 95% CI 0.87-1.00). Women randomized to zoledronic acid were significantly less likely to experience 7 or more bed-rest days owing to a fracture (RR = 0.58, 95% CI 0.47-0.72) and 7 or more limited-activity days owing to a fracture (RR = 0.67, 95% CI 0.58-0.78). Reductions in back pain with zoledronic acid were independent of incident fracture. Our conclusion is that in women with postmenopausal osteoporosis, a once-yearly infusion with zoledronic acid over a 3-year period significantly reduced the number of days that patients reported back pain, limited activity owing to back pain, and limited activity and bed rest owing to a fracture.
Resumo:
PURPOSE: Performing total knee replacement, accurate alignment and neutral rotation of the femoral component are widely believed to be crucial for the ultimate success. Contrary to absolute bone referenced alignment, using a ligament balancing technique does not automatically rotate the femoral component parallel to the transepicondylar axis. In this context we established the hypothesis that rotational alignment of the femoral component parallel to the transepicondylar axis (0° ± 3°) results in better outcome than alignment outside of this range. METHODS: We analysed 204 primary cemented mobile bearing total knee replacements five years postoperatively. Femoral component rotation was measured on axial radiographs using the condylar twist angle (CTA). Knee society score, range of motion as well as subjective rating documented outcome. RESULTS: In 96 knees the femoral component rotation was within the range 0 ± 3° (neutral rotation group), and in 108 knees the five-year postoperative rotational alignment of the femoral component was outside of this range (outlier group). Postoperative CTA showed a mean of 2.8° (±3.4°) internal rotation (IR) with a range between 6° external rotation (ER) and 15° IR (CI 95). No difference with regard to subjective and objective outcome could be detected. CONCLUSION: The present work shows that there is a large given natural variability in optimal rotational orientation, in this study between 6° ER and 15° IR, with numerous co-factors determining correct positioning of the femoral component. Further studies substantiating pre- and postoperative determinants are required to complete the understanding of resulting biomechanics in primary TKA.
Resumo:
En matière de dépistage du cancer du sein, il a été proposé de compléter les moyens techniques actuellement disponibles des praticiens du canton de Vaud par ceux d'une unité mobile de mammographie. Avant de se lancer dans cette aventure, il paraît raisonnable d'estimer le volume et la nature de la demande pour ce nouveau service. La participation des femmes vaudoises peut être évaluée par une enquête de population. Pour préparer cette enquête, un sondage téléphonique pilote a été effectué, permettant d'en estimer la faisabilité, le coût et le rendement.
Resumo:
Introduction. - « Ostéo-Mobile Vaud » est un projet pilote visant àinformer et promouvoir les mesures générales de prévention del'ostéoporose chez les femmes vaudoises de 60 ans et plus. Son butest également d'évaluer le risque de fracture dans cette populationen associant les facteurs de risque cliniques, la mesure de la DMOpar DXA de la colonne lombaire et du fémur proximal (Hologic Discovery),la recherche des fractures vertébrales préexistantes parVFA et une appréciation de la « qualité osseuse » par TBS. Une phaseprospective de 5 ans est prévue. Le Trabecular Bone Score (TBS) estun procédé qui consiste à appliquer un traitement informatique àl'image 2D de projection de la DXA basé sur la quantification desvariations locales de niveaux de gris. Un modèle mathématiquerelie le paramètre TBS avec des paramètres de microarchitecture 3Dtels la connectivité 3D, le nombre de travées et l'espace inter-trabéculaire.Ce modèle fait de TBS une mesure indirecte de microarchitectureosseuse.Résultats. - Fin juillet 2011, 510 femmes de ± 67 ans, IMC ± 26 kg/m2,ont été évaluées. Une ou plusieurs fractures de fragilité ont été rapportéeschez 72 femmes, parmi lesquelles 39 avec fractures vertébrales.TBS diminue avec l'âge (-0.005 par année, p < 0,001) etdiminue en fonction de l'IMC (- 0,011 par kg/m2, p < 0,001). La corrélationentre TBS et la DMO de la colonne lombaire est faible(r = 0,4, p < 0,001) et un grand pourcentage de la variabilité du TBSest indépendant de la DMO (> 84%). TBS discrimine les femmes avecfractures vertébrales des femmes sans fracture vertébrale et lesfemmes avec OP clinique (fractures de fragilité) de celles sans OPclinique. Ce pouvoir discriminatif est indépendant de la DMO de lacolonne lombaire ou du T-score le plus bas, après ajustement pourl'âge et l'IMC.Odd ratio (OR, 95 % IC) pour une diminution d'une déviation standarddu TBS, ajusté pour l'âge, l'IMC et la mesure de DMO :Conclusion. - TBS représente une plus-value par rapport à la DMOdans l'appréciation du risque de fracture chez les femmes vaudoisesde 60 ans et plus.