5 resultados para Microscopes
em Université de Lausanne, Switzerland
Resumo:
The functionality of adult neocortical circuits can be altered by novel experiences or learning. This functional plasticity appears to rely on changes in the strength of neuronal connections that were established during development. Here we will describe some of our studies in which we have addressed whether structural changes, including the remodeling of axons and dendrites with synapse formation and elimination, could underlie experience-dependent plasticity in the adult neocortex. Using 2-photon laser-scanning microscopes and transgenic mice expressing GFP in a subset of pyramidal cells, we have observed that a small subset of dendritic spines continuously appear and disappear on a daily basis, whereas the majority of spines persists for months. Axonal boutons from different neuronal classes displayed similar behavior, although the extent of remodeling varied. Under baseline conditions, new spines in the barrel cortex were mostly transient and rarely survived for more than a week. However, when every other whisker was trimmed, the generation and loss of persistent spines was enhanced. Ultrastructural reconstruction of previously imaged spines and boutons showed that new spines slowly form synapses. New spines persisting for a few days always had synapses, whereas very young spines often lacked synapses. New synapses were predominantly found on large, multi-synapse boutons, suggesting that spine growth is followed by synapse formation, preferentially on existing boutons. Altogether our data indicate that novel sensory experience drives the stabilization of new spines on subclasses of cortical neurons and promotes the formation of new synapses. These synaptic changes likely underlie experience-dependent functional remodeling of specific neocortical circuits.
Resumo:
Full-field X-ray microscopy is a valuable tool for 3D observation of biological systems. In the soft X-ray domain organelles can be visualized in individual cells while hard X-ray microscopes excel in imaging of larger complex biological tissue. The field of view of these instruments is typically 10(3) times the spatial resolution. We exploit the assets of the hard X-ray sub-micrometer imaging and extend the standard approach by widening the effective field of view to match the size of the sample. We show that global tomography of biological systems exceeding several times the field of view is feasible also at the nanoscale with moderate radiation dose. We address the performance issues and limitations of the TOMCAT full-field microscope and more generally for Zernike phase contrast imaging. Two biologically relevant systems were investigated. The first being the largest known bacteria (Thiomargarita namibiensis), the second is a small myriapod species (Pauropoda sp.). Both examples illustrate the capacity of the unique, structured condenser based broad-band full-field microscope to access the 3D structural details of biological systems at the nanoscale while avoiding complicated sample preparation, or even keeping the sample environment close to the natural state.
Resumo:
The antennal lobe is the primary olfactory center in the insect brain and represents the anatomical and functional equivalent of the vertebrate olfactory bulb. Olfactory information in the external world is transmitted to the antennal lobe by olfactory sensory neurons (OSNs), which segregate to distinct regions of neuropil called glomeruli according to the specific olfactory receptor they express. Here, OSN axons synapse with both local interneurons (LNs), whose processes can innervate many different glomeruli, and projection neurons (PNs), which convey olfactory information to higher olfactory brain regions. Optical imaging of the activity of OSNs, LNs and PNs in the antennal lobe - traditionally using synthetic calcium indicators (e.g. calcium green, FURA-2) or voltage-sensitive dyes (e.g. RH414) - has long been an important technique to understand how olfactory stimuli are represented as spatial and temporal patterns of glomerular activity in many species of insects. Development of genetically-encoded neural activity reporters, such as the fluorescent calcium indicators G-CaMP and Cameleon, the bioluminescent calcium indicator GFP-aequorin, or a reporter of synaptic transmission, synapto-pHluorin has made the olfactory system of the fruitfly, Drosophila melanogaster, particularly accessible to neurophysiological imaging, complementing its comprehensively-described molecular, electrophysiological and neuroanatomical properties. These reporters can be selectively expressed via binary transcriptional control systems (e.g. GAL4/UAS, LexA/LexAop, Q system) in defined populations of neurons within the olfactory circuitry to dissect with high spatial and temporal resolution how odor-evoked neural activity is represented, modulated and transformed. Here we describe the preparation and analysis methods to measure odor-evoked responses in the Drosophila antennal lobe using G-CaMP. The animal preparation is minimally invasive and can be adapted to imaging using wide-field fluorescence, confocal and two-photon microscopes.
Resumo:
Images acquired using optical microscopes are inherently subject to vignetting effects due to imperfect illumination and image acquisition. However, such vignetting effects hamper accurate extraction of quantitative information from biological images, leading to less effective image segmentation and increased noise in the measurements. Here, we describe a rapid and effective method for vignetting correction, which generates an estimate for a correction function from the background fluorescence without the need to acquire additional calibration images. We validate the usefulness of this algorithm using artificially distorted images as a gold standard for assessing the accuracy of the applied correction and then demonstrate that this correction method enables the reliable detection of biologically relevant variation in cell populations. A simple user interface called FlattifY was developed and integrated into the image analysis platform YeastQuant to facilitate easy application of vignetting correction to a wide range of images.
Resumo:
Skeletal muscle mitochondrial (Mito) and lipid droplet (Lipid) content are often measured in human translational studies. Stereological point counting allows computing Mito and Lipid volume density (Vd) from micrographs taken with transmission electron microscopes. Former studies are not specific as to the size of individual squares that make up the grids, making reproducibility difficult, particularly when different magnifications are used. Our objective was to determine which size grid would be best at predicting fractional volume efficiently without sacrificing reliability and to test a novel method to reduce sampling bias. Methods: ten subjects underwent vastus lateralis biopsies. Samples were fixed, embedded, and cut longitudinally in ultrathin sections of 60 nm. Twenty micrographs from the intramyofibrillar region were taken per subject at Ã-33,000 magnification. Different grid sizes were superimposed on each micrograph: 1,000 Ã- 1,000 nm, 500 Ã- 500 nm, and 250 Ã- 250 nm. Results: mean Mito and Lipid Vd were not statistically different across grids. Variability was greater when going from 1,000 Ã- 1,000 to 500 Ã- 500 nm grid than from 500 Ã- 500 to 250 Ã- 250 nm grid. Discussion: this study is the first to attempt to standardize grid size while keeping with the conventional stereology principles. This is all in hopes of producing replicable assessments that can be obtained universally across different studies looking at human skeletal muscle mitochondrial and lipid droplet content.