Resumo:
This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Resumo:
The determination of the age of a document is a very frequent query, however it is also one of the most challenging and controversial areas of questioned document examination. Several approaches were defined to address this problem. The first is based on the introduction date of raw constituents (like paper or ink) on the market. The second approach is based on the aging of documents, which is unfortunately not only influenced by passing time, but also by storage conditions and document composition. The third approach considers the relative age of documents and aims at reconstructing their chronology. The three approaches are equally complex to develop and encounter quantity of problems which are not negligible. This article aims to expose the potential applications and limitations of current ink dating methods. Method development and validation and the interpretation of evidence prove to be essential criteria for the dating of documents.
Resumo:
A simple and sensitive LC-MS method was developed and validated for the simultaneous quantification of aripiprazole (ARI), atomoxetine (ATO), duloxetine (DUL), clozapine (CLO), olanzapine (OLA), sertindole (STN), venlafaxine (VEN) and their active metabolites dehydroaripiprazole (DARI), norclozapine (NCLO), dehydrosertindole (DSTN) and O-desmethylvenlafaxine (OVEN) in human plasma. The above mentioned compounds and the internal standard (remoxipride) were extracted from 0.5 mL plasma by solid-phase extraction (mix mode support). The analytical separation was carried out on a reverse phase liquid chromatography at basic pH (pH 8.1) in gradient mode. All analytes were monitored by MS detection in the single ion monitoring mode and the method was validated covering the corresponding therapeutic range: 2-200 ng/mL for DUL, OLA, and STN, 4-200 ng/mL for DSTN, 5-1000 ng/mL for ARI, DARI and finally 2-1000 ng/mL for ATO, CLO, NCLO, VEN, OVEN. For all investigated compounds, good performance in terms of recoveries, selectivity, stability, repeatability, intermediate precision, trueness and accuracy, was obtained. Real patient plasma samples were then successfully analysed.
Resumo:
One of the main problems in combating tuberculosis is caused by a poor penetration of drugs into the mycobacterial cells. A prodrug approach via activation inside mycobacterial cells is a possible strategy to overcome this hurdle and achieve efficient drug uptake. Esters are attractive candidates for such a strategy and we and others communicated previously the activity of esters of weak organic acids against mycobacteria. However very little is known about ester hydrolysis by mycobacteria and no biological model is available to study the activation of prodrugs by these microorganisms. To begin filling this gap, we have embarked in a project to develop an in vitro method to study prodrug activation by mycobacteria using Mycobacterium smegmatis homogenates. Model ester substrates were ethyl nicotinate and ethyl benzoate whose hydrolysis was monitored and characterized kinetically. Our studies showed that in M. smegmatis most esterase activity is associated with the soluble fraction (cytosol) and is preserved by storage at 5°C or at room temperature for one hour, or by storage at -80°C up to one year. In the range of homogenate concentrations studied (5-80% in buffer), k(obs) varied linearly with homogenate concentration for both substrates. We also found that the homogenates showed Michaelis-Menten kinetics behavior with both prodrugs. Since ethyl benzoate is a good substrate for the mycobacterial esterases, this compound can be used to standardize the esterasic activity of homogenates, allowing results of incubations of prodrugs with homogenates from different batches to be readily compared.
Resumo:
Estimating the time since the last discharge of firearms and/or spent cartridges may be a useful piece of information in forensic firearm-related cases. The current approach consists of studying the diffusion of selected volatile organic compounds (such as naphthalene) released during the shooting using solid phase micro-extraction (SPME). However, this technique works poorly on handgun car-tridges because the extracted quantities quickly fall below the limit of detection. In order to find more effective solutions and further investigate the aging of organic gunshot residue after the discharge of handgun cartridges, an extensive study was carried out in this work using a novel approach based on high capacity headspace sorptive extraction (HSSE). By adopting this technique, for the first time 51 gunshot residue (GSR) volatile organic compounds could be simultaneously detected from fired handgun cartridge cases. Application to aged specimens showed that many of those compounds presented significant and complementary aging profiles. Compound-to-compound ratios were also tested and proved to be beneficial both in reducing the variability of the aging curves and in enlarging the time window useful in a forensic casework perspective. The obtained results were thus particularly promising for the development of a new complete forensic dating methodology.
Resumo:
Platelet-rich plasma (PRP) is a volume of plasma fraction of autologous blood having platelet concentrations above baseline whole-blood values due to processing and concentration. PRP is used in various surgical fields to enhance soft-tissue and bone healing by delivering supra-physiological concentrations of autologous platelets at the site of tissue damage. These preparations may provide a good cellular source of various growth factors and cytokines, and modulate tissue response to injury. Common clinically available materials for blood preparations combined with a two-step centrifugation protocol at 280g each, to ensure cellular component integrity, provided platelet preparations which were concentrated 2-3 fold over total blood values. Costs were shown to be lower than those of other methods which require specific equipment and high-cost disposables, while safety and traceability can be increased. PRP can be used for the treatment of wounds of all types including burns and also of split-thickness skin graft donor sites, which are frequently used in burn management. The procedure can be standardized and is easy to adapt in clinical settings with minimal infrastructure, thus enabling large numbers of patients to benefit from a form of cellular therapy.
Resumo:
The purpose of this paper is to describe the development and to test the reliability of a new method called INTERMED, for health service needs assessment. The INTERMED integrates the biopsychosocial aspects of disease and the relationship between patient and health care system in a comprehensive scheme and reflects an operationalized conceptual approach to case mix or case complexity. The method is developed to enhance interdisciplinary communication between (para-) medical specialists and to provide a method to describe case complexity for clinical, scientific, and educational purposes. First, a feasibility study (N = 21 patients) was conducted which included double scoring and discussion of the results. This led to a version of the instrument on which two interrater reliability studies were performed. In study 1, the INTERMED was double scored for 14 patients admitted to an internal ward by a psychiatrist and an internist on the basis of a joint interview conducted by both. In study 2, on the basis of medical charts, two clinicians separately double scored the INTERMED in 16 patients referred to the outpatient psychiatric consultation service. Averaged over both studies, in 94.2% of all ratings there was no important difference between the raters (more than 1 point difference). As a research interview, it takes about 20 minutes; as part of the whole process of history taking it takes about 15 minutes. In both studies, improvements were suggested by the results. Analyses of study 1 revealed that on most items there was considerable agreement; some items were improved. Also, the reference point for the prognoses was changed so that it reflected both short- and long-term prognoses. Analyses of study 2 showed that in this setting, less agreement between the raters was obtained due to the fact that the raters were less experienced and the scoring procedure was more susceptible to differences. Some improvements--mainly of the anchor points--were specified which may further enhance interrater reliability. The INTERMED proves to be a reliable method for classifying patients' care needs, especially when used by experienced raters scoring by patient interview. It can be a useful tool in assessing patients' care needs, as well as the level of needed adjustment between general and mental health service delivery. The INTERMED is easily applicable in the clinical setting at low time-costs.
Resumo:
To study the stress-induced effects caused by wounding under a new perspective, a metabolomic strategy based on HPLC-MS has been devised for the model plant Arabidopsis thaliana. To detect induced metabolites and precisely localise these compounds among the numerous constitutive metabolites, HPLC-MS analyses were performed in a two-step strategy. In a first step, rapid direct TOF-MS measurements of the crude leaf extract were performed with a ballistic gradient on a short LC-column. The HPLC-MS data were investigated by multivariate analysis as total mass spectra (TMS). Principal components analysis (PCA) and hierarchical cluster analysis (HCA) on principal coordinates were combined for data treatment. PCA and HCA demonstrated a clear clustering of plant specimens selecting the highest discriminating ions given by the complete data analysis, leading to the specific detection of discrete-induced ions (m/z values). Furthermore, pool constitution with plants of homogeneous behaviour was achieved for confirmatory analysis. In this second step, long high-resolution LC profilings on an UPLC-TOF-MS system were used on pooled samples. This allowed to precisely localise the putative biological marker induced by wounding and by specific extraction of accurate m/z values detected in the screening procedure with the TMS spectra.
Resumo:
Ethyl glucuronide (EtG) is a minor and direct metabolite of ethanol. EtG is incorporated into the growing hair allowing retrospective investigation of chronic alcohol abuse. In this study, we report the development and the validation of a method using gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS) for the quantification of EtG in hair. EtG was extracted from about 30 mg of hair by aqueous incubation and purified by solid-phase extraction (SPE) using mixed mode extraction cartridges followed by derivation with perfluoropentanoic anhydride (PFPA). The analysis was performed in the selected reaction monitoring (SRM) mode using the transitions m/z 347-->163 (for the quantification) and m/z 347-->119 (for the identification) for EtG, and m/z 352-->163 for EtG-d(5) used as internal standard. For validation, we prepared quality controls (QC) using hair samples taken post mortem from 2 subjects with a known history of alcoholism. These samples were confirmed by a proficiency test with 7 participating laboratories. The assay linearity of EtG was confirmed over the range from 8.4 to 259.4 pg/mg hair, with a coefficient of determination (r(2)) above 0.999. The limit of detection (LOD) was estimated with 3.0 pg/mg. The lower limit of quantification (LLOQ) of the method was fixed at 8.4 pg/mg. Repeatability and intermediate precision (relative standard deviation, RSD%), tested at 4 QC levels, were less than 13.2%. The analytical method was applied to several hair samples obtained from autopsy cases with a history of alcoholism and/or lesions caused by alcohol. EtG concentrations in hair ranged from 60 to 820 pg/mg hair.
Resumo:
Personal results are presented to illustrate the development of immunoscintigraphy for the detection of cancer over the last 12 years, from the early experimental results in nude mice grafted with human colon carcinoma to the most modern form of immunoscintigraphy applied to patients, using I123 labeled Fab fragments from monoclonal anti-CEA antibodies detected by single photon emission computerized tomography (SPECT). The first generation of immunoscintigraphy used I131 labeled, immunoadsorbent purified, polyclonal anti-CEA antibodies and planar scintigraphy, as the detection system. The second generation used I131 labeled monoclonal anti-CEA antibodies and SPECT, while the third generation employed I123 labeled fragments of monoclonal antibodies and SPECT. The improvement in the precision of tumor images with the most recent forms of immunoscintigraphy is obvious. However, we think the usefulness of immunoscintigraphy for routine cancer management has not yet been entirely demonstrated. Further prospective trials are still necessary to determine the precise clinical role of immunoscintigraphy. A case report is presented on a patient with two liver metastases from a sigmoid carcinoma, who received through the hepatic artery a therapeutic dose (100 mCi) of I131 coupled to 40 mg of a mixture of two high affinity anti-CEA monoclonal antibodies. Excellent localisation in the metastases of the I131 labeled antibodies was demonstrated by SPECT and the treatment was well tolerated. The irradiation dose to the tumor, however, was too low at 4300 rads (with 1075 rads to the normal liver and 88 rads to the bone marrow), and no evidence of tumor regression was obtained. Different approaches for increasing the irradiation dose delivered to the tumor by the antibodies are considered.
Resumo:
Résumé : Cette thèse de doctorat est le fruit d'un projet de recherche européen financé par le quatrième programme cadre de la Commission Européenne (DG XII, Standards, Measurement and Testing). Ce projet, dénommé SMT-CT98-2277, a été financé pour la partie suisse par l'Office Fédéral de l'Education et de la Science (OFES, Berne, Suisse). Le but de ce projet était de développer une méthode harmonisée et collaborativement testée pour le profilage des impuretés de l'amphétamine illicite par chromatographie capillaire en phase gazeuse. Le travail a été divisé en sept phases majeures qui concernaient la synthèse de l'amphétamine, l'identification d'impuretés, l'optimisation de la préparation de l'échantillon et du système chromatographique, la variabilité des résultats, l'investigation de méthodes mathématiques pour la classification et la comparaison de profils et finalement l'application de la méthode à des réels échantillons illicites. La méthode résultant de ce travail n'a pas seulement montré que les données étaient interchangeables entre laboratoires mais aussi qu'elle était supérieure en de nombreux points aux méthodes préalablement publiées dans la littérature scientifique. Abstract : This Ph.D. thesis was carried out in parallel to an European project funded by the fourth framework program of the European Commission (DG XII, Standards, Measurement and Testing). This project, named SMT-CT98-2277 was funded, for the Swiss part, by the Federal Office of Education and Science (OFES, Bern, Switzerland). The aim of the project was to develop a harmonised, collaboratively tested method for the impurity profiling of illicit amphetamine by capillary gas chromatography. The work was divided into seven main tasks which deal with the synthesis of amphetamine, identification of impurities, optimization of sample preparation and of the chromatographic system, variability of the results, investigation of numerical methods for the classification and comparison of profiles and finally application of the methodology to real illicit samples. The resulting method has not only shown to produce interchangeable data between different laboratories but was also found to be superior in many aspects to previously published methods.
Resumo:
Following their detection and seizure by police and border guard authorities, false identity and travel documents are usually scanned, producing digital images. This research investigates the potential of these images to classify false identity documents, highlight links between documents produced by a same modus operandi or same source, and thus support forensic intelligence efforts. Inspired by previous research work about digital images of Ecstasy tablets, a systematic and complete method has been developed to acquire, collect, process and compare images of false identity documents. This first part of the article highlights the critical steps of the method and the development of a prototype that processes regions of interest extracted from images. Acquisition conditions have been fine-tuned in order to optimise reproducibility and comparability of images. Different filters and comparison metrics have been evaluated and the performance of the method has been assessed using two calibration and validation sets of documents, made up of 101 Italian driving licenses and 96 Portuguese passports seized in Switzerland, among which some were known to come from common sources. Results indicate that the use of Hue and Edge filters or their combination to extract profiles from images, and then the comparison of profiles with a Canberra distance-based metric provides the most accurate classification of documents. The method appears also to be quick, efficient and inexpensive. It can be easily operated from remote locations and shared amongst different organisations, which makes it very convenient for future operational applications. The method could serve as a first fast triage method that may help target more resource-intensive profiling methods (based on a visual, physical or chemical examination of documents for instance). Its contribution to forensic intelligence and its application to several sets of false identity documents seized by police and border guards will be developed in a forthcoming article (part II).
Resumo:
Résumé : Les progrès techniques de la spectrométrie de masse (MS) ont contribué au récent développement de la protéomique. Cette technique peut actuellement détecter, identifier et quantifier des milliers de protéines. Toutefois, elle n'est pas encore assez puissante pour fournir une analyse complète des modifications du protéome corrélées à des phénomènes biologiques. Notre objectif était le développement d'une nouvelle stratégie pour la détection spécifique et la quantification des variations du protéome, basée sur la mesure de la synthèse des protéines plutôt que sur celle de la quantité de protéines totale. Pour cela, nous volions associer le marquage pulsé des protéines par des isotopes stables avec une méthode d'acquisition MS basée sur le balayage des ions précurseurs (precursor ion scan, ou PIS), afin de détecter spécifiquement les protéines ayant intégré les isotopes et d'estimer leur abondance par rapport aux protéines non marquées. Une telle approche peut identifier les protéines avec les plus hauts taux de synthèse dans une période de temps donnée, y compris les protéines dont l'expression augmente spécifiquement suite à un événement précis. Nous avons tout d'abord testé différents acides aminés marqués en combinaison avec des méthodes PIS spécifiques. Ces essais ont permis la détection spécifique des protéines marquées. Cependant, en raison des limitations instrumentales du spectromètre de masse utilisé pour les méthodes PIS, la sensibilité de cette approche s'est révélée être inférieure à une analyse non ciblée réalisée sur un instrument plus récent (Chapitre 2.1). Toutefois, pour l'analyse différentielle de deux milieux de culture conditionnés par des cellules cancéreuses humaines, nous avons utilisé le marquage métabolique pour distinguer les protéines d'origine cellulaire des protéines non marquées du sérum présentes dans les milieux de culture (Chapitre 2.2). Parallèlement, nous avons développé une nouvelle méthode de quantification nommée IBIS, qui utilise des paires d'isotopes stables d'acides aminés capables de produire des ions spécifiques qui peuvent être utilisés pour la quantification relative. La méthode IBIS a été appliquée à l'analyse de deux lignées cellulaires cancéreuses complètement marquées, mais de manière différenciée, par des paires d'acides aminés (Chapitre 2.3). Ensuite, conformément à l'objectif initial de cette thèse, nous avons utilisé une variante pulsée de l'IBIS pour détecter des modifications du protéome dans des cellules HeLa infectée par le virus humain Herpes Simplex-1 (Chapitre 2.4). Ce virus réprime la synthèse des protéines des cellules hôtes afin d'exploiter leur mécanisme de traduction pour la production massive de virions. Comme prévu, de hauts taux de synthèse ont été mesurés pour les protéines virales détectées, attestant de leur haut niveau d'expression. Nous avons de plus identifié un certain nombre de protéines humaines dont le rapport de synthèse et de dégradation (S/D) a été modifié par l'infection virale, ce qui peut donner des indications sur les stratégies utilisées par les virus pour détourner la machinerie cellulaire. En conclusion, nous avons montré dans ce travail que le marquage métabolique peut être employé de façon non conventionnelle pour étudier des dimensions peu explorées en protéomique. Summary : In recent years major technical advancements greatly supported the development of mass spectrometry (MS)-based proteomics. Currently, this technique can efficiently detect, identify and quantify thousands of proteins. However, it is not yet sufficiently powerful to provide a comprehensive analysis of the proteome changes correlated with biological phenomena. The aim of our project was the development of ~a new strategy for the specific detection and quantification of proteomé variations based on measurements of protein synthesis rather than total protein amounts. The rationale for this approach was that changes in protein synthesis more closely reflect dynamic cellular responses than changes in total protein concentrations. Our starting idea was to couple "pulsed" stable-isotope labeling of proteins with a specific MS acquisition method based on precursor ion scan (PIS), to specifically detect proteins that incorporated the label and to simultaneously estimate their abundance, relative to the unlabeled protein isoform. Such approach could highlight proteins with the highest synthesis rate in a given time frame, including proteins specifically up-regulated by a given biological stimulus. As a first step, we tested different isotope-labeled amino acids in combination with dedicated PIS methods and showed that this leads to specific detection of labeled proteins. Sensitivity, however, turned out to be lower than an untargeted analysis run on a more recent instrument, due to MS hardware limitations (Chapter 2.1). We next used metabolic labeling to distinguish the proteins of cellular origin from a high background of unlabeled (serum) proteins, for the differential analysis of two serum-containing culture media conditioned by labeled human cancer cells (Chapter 2.2). As a parallel project we developed a new quantification method (named ISIS), which uses pairs of stable-isotope labeled amino acids able to produce specific reporter ions, which can be used for relative quantification. The ISIS method was applied to the analysis of two fully, yet differentially labeled cancer cell lines, as described in Chapter 2.3. Next, in line with the original purpose of this thesis, we used a "pulsed" variant of ISIS to detect proteome changes in HeLa cells after the infection with human Herpes Simplex Virus-1 (Chapter 2.4). This virus is known to repress the synthesis of host cell proteins to exploit the translation machinery for the massive production of virions. As expected, high synthesis rates were measured for the detected viral proteins, confirming their up-regulation. Moreover, we identified a number of human proteins whose synthesis/degradation ratio (S/D) was affected by the viral infection and which could provide clues on the strategies used by the virus to hijack the cellular machinery. Overall, in this work, we showed that metabolic labeling can be employed in alternative ways to investigate poorly explored dimensions in proteomics.
Resumo:
BACKGROUND: Cone-beam computed tomography (CBCT) image-guided radiotherapy (IGRT) systems are widely used tools to verify and correct the target position before each fraction, allowing to maximize treatment accuracy and precision. In this study, we evaluate automatic three-dimensional intensity-based rigid registration (RR) methods for prostate setup correction using CBCT scans and study the impact of rectal distension on registration quality. METHODS: We retrospectively analyzed 115 CBCT scans of 10 prostate patients. CT-to-CBCT registration was performed using (a) global RR, (b) bony RR, or (c) bony RR refined by a local prostate RR using the CT clinical target volume (CTV) expanded with 1-to-20-mm varying margins. After propagation of the manual CT contours, automatic CBCT contours were generated. For evaluation, a radiation oncologist manually delineated the CTV on the CBCT scans. The propagated and manual CBCT contours were compared using the Dice similarity and a measure based on the bidirectional local distance (BLD). We also conducted a blind visual assessment of the quality of the propagated segmentations. Moreover, we automatically quantified rectal distension between the CT and CBCT scans without using the manual CBCT contours and we investigated its correlation with the registration failures. To improve the registration quality, the air in the rectum was replaced with soft tissue using a filter. The results with and without filtering were compared. RESULTS: The statistical analysis of the Dice coefficients and the BLD values resulted in highly significant differences (p<10(-6)) for the 5-mm and 8-mm local RRs vs the global, bony and 1-mm local RRs. The 8-mm local RR provided the best compromise between accuracy and robustness (Dice median of 0.814 and 97% of success with filtering the air in the rectum). We observed that all failures were due to high rectal distension. Moreover, the visual assessment confirmed the superiority of the 8-mm local RR over the bony RR. CONCLUSION: The most successful CT-to-CBCT RR method proved to be the 8-mm local RR. We have shown the correlation between its registration failures and rectal distension. Furthermore, we have provided a simple (easily applicable in routine) and automatic method to quantify rectal distension and to predict registration failure using only the manual CT contours.