17 resultados para Medical systems

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Over-resuscitation is deleterious in many critically ill conditions, including major burns. For more than 15 years, several strategies to reduce fluid administration in burns during the initial resuscitation phase have been proposed, but no single or simple parameter has shown superiority. Fluid administration guided by invasive hemodynamic parameters usually resulted in over-resuscitation. As reported in the previous issue of Critical Care, Sánchez-Sánchez and colleagues analyzed the performance of a 'permissive hypovolemia' protocol guided by invasive hemodynamic parameters (PiCCO, Pulsion Medical Systems, Munich, Germany) and vital signs in a prospective cohort over a 3-year period. The authors' results confirm that resuscitation can be achieved with below-normal levels of preload but at the price of a fluid administration greater than predicted by the Parkland formula (2 to 4 mL/kg per% burn). The classic approach based on an adapted Parkland equation may still be the simplest until further studies identify the optimal bundle of resuscitation goals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Empirical evidence supports the hypothesis that emotional states might contribute to cardiovascular disease and health through multiple pathways. To the extent that the acute cardiovascular response to emotional events plays a role in cardiovascular health and disease, an essential step in order to understand this possible link is to define the hemodynamic response to affective challenges. This was the aim of the present study. We assessed blood pressure (BP), heart rate (HR), stroke volume (SV), cardiac output, and total peripheral resistance (TPR) in response to 13 picture series in 18 men and 19 women (mean age 26) in order to investigate their hemodynamic responses associated with activation of the appetitive and defensive motivational systems underlying emotional experience. The hemodynamic parameters were recorded by finger-cuff photoplethysmography with Finometer™ (FMS Finapres Medical Systems, Amsterdam) and electrocardiography with the Lifeshirt system (VivoMetrics Inc., Ventura, California). Participants rated self-perceived pleasantness and arousal for each series. In men, BP and SV, but not TPR, increased with increasing self-rated arousal both for appetitive and defensive activation, whereas in women these relationships were almost absent, especially, for defensive activation. HR decelerated more in response to negative than positive and neutral pictures, and more so in men than women. These findings indicate striking sex differences. In particular, it is suggested that the sympathetic inotropic effect to the heart increases with increasing self-rated arousal strongly in men but only weakly in women. Regardless of sex differences, the modulation of the cardiovascular response to affective pictures along the dimensions of pleasantness and arousal is primarily myocardial, and the pattern of cardiovascular response is consistent with a configuration of cardiac sympathetic-parasympathetic coactivation. One possible implication of the observed sex differences concerns the link between affective states and cardiovascular health and disease. Men have a higher incidence of cardiovascular diseases than premenopausal women, and exaggerated sympathetic reactivity to emotional events is a potential pathophysiological mechanism. These findings extend current knowledge showing that under several acute behavioral challenges men demonstrate stronger cardiovascular reactivity than women.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: Visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. MATERIALS AND METHODS: Coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: In contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. CONCLUSION: The combination of a free-breathing navigator-gated and cardiac-triggered 3D SSFP sequence with a slice-selective inversion pre-pulse allows for direct and directional visualization of coronary blood flow with the additional benefit of improved contrast between coronary and right ventricular blood pool.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Motivation. The study of human brain development in itsearly stage is today possible thanks to in vivo fetalmagnetic resonance imaging (MRI) techniques. Aquantitative analysis of fetal cortical surfacerepresents a new approach which can be used as a markerof the cerebral maturation (as gyration) and also forstudying central nervous system pathologies [1]. However,this quantitative approach is a major challenge forseveral reasons. First, movement of the fetus inside theamniotic cavity requires very fast MRI sequences tominimize motion artifacts, resulting in a poor spatialresolution and/or lower SNR. Second, due to the ongoingmyelination and cortical maturation, the appearance ofthe developing brain differs very much from thehomogenous tissue types found in adults. Third, due tolow resolution, fetal MR images considerably suffer ofpartial volume (PV) effect, sometimes in large areas.Today extensive efforts are made to deal with thereconstruction of high resolution 3D fetal volumes[2,3,4] to cope with intra-volume motion and low SNR.However, few studies exist related to the automatedsegmentation of MR fetal imaging. [5] and [6] work on thesegmentation of specific areas of the fetal brain such asposterior fossa, brainstem or germinal matrix. Firstattempt for automated brain tissue segmentation has beenpresented in [7] and in our previous work [8]. Bothmethods apply the Expectation-Maximization Markov RandomField (EM-MRF) framework but contrary to [7] we do notneed from any anatomical atlas prior. Data set &Methods. Prenatal MR imaging was performed with a 1-Tsystem (GE Medical Systems, Milwaukee) using single shotfast spin echo (ssFSE) sequences (TR 7000 ms, TE 180 ms,FOV 40 x 40 cm, slice thickness 5.4mm, in plane spatialresolution 1.09mm). Each fetus has 6 axial volumes(around 15 slices per volume), each of them acquired inabout 1 min. Each volume is shifted by 1 mm with respectto the previous one. Gestational age (GA) ranges from 29to 32 weeks. Mother is under sedation. Each volume ismanually segmented to extract fetal brain fromsurrounding maternal tissues. Then, in-homogeneityintensity correction is performed using [9] and linearintensity normalization is performed to have intensityvalues that range from 0 to 255. Note that due tointra-tissue variability of developing brain someintensity variability still remains. For each fetus, ahigh spatial resolution image of isotropic voxel size of1.09 mm is created applying [2] and using B-splines forthe scattered data interpolation [10] (see Fig. 1). Then,basal ganglia (BS) segmentation is performed on thissuper reconstructed volume. Active contour framework witha Level Set (LS) implementation is used. Our LS follows aslightly different formulation from well-known Chan-Vese[11] formulation. In our case, the LS evolves forcing themean of the inside of the curve to be the mean intensityof basal ganglia. Moreover, we add local spatial priorthrough a probabilistic map created by fitting anellipsoid onto the basal ganglia region. Some userinteraction is needed to set the mean intensity of BG(green dots in Fig. 2) and the initial fitting points forthe probabilistic prior map (blue points in Fig. 2). Oncebasal ganglia are removed from the image, brain tissuesegmentation is performed as described in [8]. Results.The case study presented here has 29 weeks of GA. Thehigh resolution reconstructed volume is presented in Fig.1. The steps of BG segmentation are shown in Fig. 2.Overlap in comparison with manual segmentation isquantified by the Dice similarity index (DSI) equal to0.829 (values above 0.7 are considered a very goodagreement). Such BG segmentation has been applied on 3other subjects ranging for 29 to 32 GA and the DSI hasbeen of 0.856, 0.794 and 0.785. Our segmentation of theinner (red and blue contours) and outer cortical surface(green contour) is presented in Fig. 3. Finally, torefine the results we include our WM segmentation in theFreesurfer software [12] and some manual corrections toobtain Fig.4. Discussion. Precise cortical surfaceextraction of fetal brain is needed for quantitativestudies of early human brain development. Our workcombines the well known statistical classificationframework with the active contour segmentation forcentral gray mater extraction. A main advantage of thepresented procedure for fetal brain surface extraction isthat we do not include any spatial prior coming fromanatomical atlases. The results presented here arepreliminary but promising. Our efforts are now in testingsuch approach on a wider range of gestational ages thatwe will include in the final version of this work andstudying as well its generalization to different scannersand different type of MRI sequences. References. [1]Guibaud, Prenatal Diagnosis 29(4) (2009). [2] Rousseau,Acad. Rad. 13(9), 2006, [3] Jiang, IEEE TMI 2007. [4]Warfield IADB, MICCAI 2009. [5] Claude, IEEE Trans. Bio.Eng. 51(4) (2004). [6] Habas, MICCAI (Pt. 1) 2008. [7]Bertelsen, ISMRM 2009 [8] Bach Cuadra, IADB, MICCAI 2009.[9] Styner, IEEE TMI 19(39 (2000). [10] Lee, IEEE Trans.Visual. And Comp. Graph. 3(3), 1997, [11] Chan, IEEETrans. Img. Proc, 10(2), 2001 [12] Freesurfer,http://surfer.nmr.mgh.harvard.edu.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The ancient Greek medical theory based on balance or imbalance of humors disappeared in the western world, but does survive elsewhere. Is this survival related to a certain degree of health care efficiency? We explored this hypothesis through a study of classical Greco-Arab medicine in Mauritania. Modern general practitioners evaluated the safety and effectiveness of classical Arabic medicine in a Mauritanian traditional clinic, with a prognosis/follow-up method allowing the following comparisons: (i) actual patient progress (clinical outcome) compared with what the traditional 'tabib' had anticipated (= prognostic ability) and (ii) patient progress compared with what could be hoped for if the patient were treated by a modern physician in the same neighborhood. The practice appeared fairly safe and, on average, clinical outcome was similar to what could be expected with modern medicine. In some cases, patient progress was better than expected. The ability to correctly predict an individual's clinical outcome did not seem to be better along modern or Greco-Arab theories. Weekly joint meetings (modern and traditional practitioners) were spontaneously organized with a modern health centre in the neighborhood. Practitioners of a different medical system can predict patient progress. For the patient, avoiding false expectations with health care and ensuring appropriate referral may be the most important. Prognosis and outcome studies such as the one presented here may help to develop institutions where patients find support in making their choices, not only among several treatment options, but also among several medical systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The assessment of medical technologies has to answer several questions ranging from safety and effectiveness to complex economical, social, and health policy issues. The type of data needed to carry out such evaluation depends on the specific questions to be answered, as well as on the stage of development of a technology. Basically two types of data may be distinguished: (a) general demographic, administrative, or financial data which has been collected not specifically for technology assessment; (b) the data collected with respect either to a specific technology or to a disease or medical problem. On the basis of a pilot inquiry in Europe and bibliographic research, the following categories of type (b) data bases have been identified: registries, clinical data bases, banks of factual and bibliographic knowledge, and expert systems. Examples of each category are discussed briefly. The following aims for further research and practical goals are proposed: criteria for the minimal data set required, improvement to the registries and clinical data banks, and development of an international clearinghouse to enhance information diffusion on both existing data bases and available reports on medical technology assessments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess whether formatting the medical order sheet has an effect on the accuracy and security of antibiotics prescription. DESIGN: Prospective assessment of antibiotics prescription over time, before and after the intervention, in comparison with a control ward. SETTING: The medical and surgical intensive care unit (ICU) of a university hospital. PATIENTS: All patients hospitalized in the medical or surgical ICU between February 1 and April 30, 1997, and July 1 and August 31, 2000, for whom antibiotics were prescribed. INTERVENTION: Formatting of the medical order sheet in the surgical ICU in 1998. MEASUREMENTS AND MAIN RESULTS: Compliance with the American Society of Hospital Pharmacists' criteria for prescription safety was measured. The proportion of safe orders increased in both units, but the increase was 4.6 times greater in the surgical ICU (66% vs. 74% in the medical ICU and 48% vs. 74% in the surgical ICU). For unsafe orders, the proportion of ambiguous orders decreased by half in the medical ICU (9% vs. 17%) and nearly disappeared in the surgical ICU (1% vs. 30%). The only missing criterion remaining in the surgical ICU was the drug dose unit, which could not be preformatted. The aim of antibiotics prescription (either prophylactic or therapeutic) was indicated only in 51% of the order sheets. CONCLUSIONS: Formatting of the order sheet markedly increased security of antibiotics prescription. These findings must be confirmed in other settings and with different drug classes. Formatting the medical order sheet decreases the potential for prescribing errors before full computerized prescription is available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les coûts de traitement de certains patients s'avèrent extrêmement élevés, et peuvent faire soupçonner une prise en charge médicale inadéquate. Comme I'évolution du remboursement des prestations hospitalières passe à des forfaits par pathologie, il est essentiel de vérifier ce point, d'essayer de déterminer si ce type de patients peut être identifié à leur admission, et de s'assurer que leur devenir soit acceptable. Pour les années 1995 et 1997. les coûts de traitement dépassant de 6 déviations standard le coût moyen de la catégorie diagnostique APDRG ont été identifiés, et les dossiers des 50 patients dont les coûts variables étaient les plus élevés ont été analysés. Le nombre total de patients dont I'hospitalisation a entraîné des coûts extrêmes a passé de 391 en 1995 à 328 patients en 1997 (-16%). En ce qui concerne les 50 patients ayant entraîné les prises en charge les plus chères de manière absolue, les longs séjours dans de multiples services sont fréquents, mais 90% des patients sont sortis de l'hôpital en vie, et près de la moitié directement à domicile. Ils présentaient une variabilité importante de diagnostics et d'interventions, mais pas d'évidence de prise en charge inadéquate. En conclusion, les patients qualifiés de cas extrêmes sur un plan économique, ne le sont pas sur un plan strictement médical, et leur devenir est bon. Face à la pression qu'exercera le passage à un mode de financement par pathologie, les hôpitaux doivent mettre au point un système de revue interne de I'adéquation des prestations fournies basées sur des caractéristiques cliniques, s'ils veulent garantir des soins de qualité. et identifier les éventuelles prestations sous-optimales qu'ils pourraient être amenés à délivrer. [Auteurs] Treatment costs for some patients are extremely high and might let think that medical care could have been inadequate. As hospital financing systems move towards reimbursement by diagnostic groups, it is essential to assess whether inadequate care is provided, to try to identify these patients upon admission, and make sure that their outcome is good. For the years 1995 and 1997, treatment costs exceeding by 6 standard deviations the average cost of their APDRG category were identified, and the charts of the 50 patients with the highest variable costs were analyzed. The total number of patients with such extreme costs diminished from 391 in 1995 to 328 in 1997 (-16%). For the 50 most expensive patients, long stays in several services were frequent, but 90% of these patients left the hospital alive, and about half directly to their home. They presented an important variation in diagnoses and operations, but no evidence for inadequate care. Thus, patients qualified as extreme from an economic perspective cannot be qualified as such from a medical perspective, and their outcome is good. To face the pressure linked with the change in financing system, hospitals must develop an internal review system for assessing the adequacy of care, based on clinical characteristics, if they want to guarantee good quality of care and identify potentially inadequate practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The occurrence of the 2003 G8 summit in Evian and the threat of major civil riots or even terrorist attacks in the Swiss neighbourhood forced us to imagine a new system of rescue and medical care in case of numerous victims. Previous occurrences of the G8 in Europe or America have demonstrated the need of flexible and mobile structures, able to respond quickly to crowd movements, unlike the usual static structure of rescue systems designed for major accidents. METHODS: We developed a new concept of Mobile Medical Squadrons (MMS) consisting of several vehicles and medical care and rescue human resources. In our concept, each MMS consisted of 3 emergency doctors, 5 paramedics and 9 first-aid workers. They were designed to handle 15 patients, with a large autonomy in terms of rescue, medical care, evacuation and medical authority. The equipment included medical, resuscitation, simple decontamination, evacuation and communication materials. RESULTS: The MMS were dispatched four times during the G8 summit following civil riots. They took care of 12 injured patients. CONCLUSION: The concept of MMS as a reinforcement of the existing rescue and health care resources appears as a new flexible, a modular and useful concept for the medical management of collective prehospital emergency situations. Its use is suggested instead of the traditional static concept of rescue systems designed for major accidents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives Medical futility at the end of life is a growing challenge to medicine. The goals of the authors were to elucidate how clinicians define futility, when they perceive life-sustaining treatment (LST) to be futile, how they communicate this situation and why LST is sometimes continued despite being recognised as futile. Methods The authors reviewed ethics case consultation protocols and conducted semi-structured interviews with 18 physicians and 11 nurses from adult intensive and palliative care units at a tertiary hospital in Germany. The transcripts were subjected to qualitative content analysis. Results Futility was identified in the majority of case consultations. Interviewees associated futility with the failure to achieve goals of care that offer a benefit to the patient's quality of life and are proportionate to the risks, harms and costs. Prototypic examples mentioned are situations of irreversible dependence on LST, advanced metastatic malignancies and extensive brain injury. Participants agreed that futility should be assessed by physicians after consultation with the care team. Intensivists favoured an indirect and stepwise disclosure of the prognosis. Palliative care clinicians focused on a candid and empathetic information strategy. The reasons for continuing futile LST are primarily emotional, such as guilt, grief, fear of legal consequences and concerns about the family's reaction. Other obstacles are organisational routines, insufficient legal and palliative knowledge and treatment requests by patients or families. Conclusion Managing futility could be improved by communication training, knowledge transfer, organisational improvements and emotional and ethical support systems. The authors propose an algorithm for end-of-life decision making focusing on goals of treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. METHODS: This was a prospective study. Over an 8-week period, our EMS dispatchers were given new procedures to provide T-CPR. We then collected data on all non-traumatic cardiac arrests within our state (Vaud, Switzerland) for the following 12months. For each event, the dispatchers had to record in writing the reason they either ruled out cardiac arrest (CA) or did not propose T-CPR in the event they did suspect CA. All emergency call recordings were reviewed by the medical director of the EMS. The analysis of the recordings and the dispatchers' written explanations were then compared. RESULTS: During the 12-month study period, a total of 497 patients (both adults and children) were identified as having a non-traumatic cardiac arrest. Out of this total, 203 cases were excluded and 294 cases were eligible for T-CPR. Out of these eligible cases, dispatchers proposed T-CPR on 202 occasions (or 69% of eligible cases). They also erroneously proposed T-CPR on 17 occasions when a CA was wrongly identified (false positive). This represents 7.8% of all T-CPR. No costs were incurred to implement our study protocol and procedures. CONCLUSIONS: This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery rate and false positive are similar to those found in previous studies. We found our results satisfying the given short time frame of this study. Our results demonstrate that it is possible to improve the quality of emergency services at moderate or even no additional costs and this should be of interest to all EMS that do not presently benefit from using T-CPR procedures. EMS that currently do not offer T-CPR should consider implementing this technique as soon as possible, and we expect our experience may provide answers to those planning to incorporate T-CPR in their daily practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Previous published studies have shown significant variations in colonoscopy performance, even when medical factors are taken into account. This study aimed to examine the role of nonmedical factors (ie, embodied in health care system design) as possible contributors to variations in colonoscopy performance. METHODS: Patient data from a multicenter observational study conducted between 2000 and 2002 in 21 centers in 11 western countries were used. Variability was captured through 2 performance outcomes (diagnostic yield and colonoscopy withdrawal time), jointly studied as dependent variables, using a multilevel 2-equation system. RESULTS: Results showed that open-access systems and high-volume colonoscopy centers were independently associated with a higher likelihood of detecting significant lesions and longer withdrawal durations. Fee for service (FFS) payment was associated with shorter withdrawal durations, and so had an indirect negative impact on the diagnostic yield. Teaching centers exhibited lower detection rates and longer withdrawal times. CONCLUSIONS: Our results suggest that gatekeeping colonoscopy is likely to miss patients with significant lesions and that developing specialized colonoscopy units is important to improve performance. Results also suggest that FFS may result in a lower quality of care in colonoscopy practice and highlight the fact that longer withdrawal times do not necessarily indicate higher quality in teaching centers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In our recent paper by Monnin et al. [Med. Phys. 33, 411-420 (2006)], an objective analysis of the relative performance of a computed radiography (CR) system using both standard single-side (ST-VI) and prototype dual-side read (ST-BD) plates was reported. The presampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of paediatric chest radiography, at an entrance detector air kerma of 5 microGy. Experiments demonstrated that, compared to the standard single-side read system, the MTF for the dual-side read system was slightly reduced, but a significant decrease in image noise resulted in a marked increase in DQE (+40%) in the low spatial frequency range. However, the DQE improvement for the ST-BD plate decreased with increasing spatial frequency, and, at spatial frequencies above 2.2 mm(-1), the DQE of the dual-side read system was lower than that of the single-side one.