164 resultados para Magnetic polymeric particles
em Université de Lausanne, Switzerland
Resumo:
We investigated the use of in situ implant formation that incorporates superparamagnetic iron oxide nanoparticles (SPIONs) as a form of minimally invasive treatment of cancer lesions by magnetically induced local hyperthermia. We developed injectable formulations that form gels entrapping magnetic particles into a tumor. We used SPIONs embedded in silica microparticles to favor syringeability and incorporated the highest proportion possible to allow large heating capacities. Hydrogel, single-solvent organogel and cosolvent (low-toxicity hydrophilic solvent) organogel formulations were injected into human cancer tumors xenografted in mice. The thermoreversible hydrogels (poloxamer, chitosan), which accommodated 20% w/v of the magnetic microparticles, proved to be inadequate. Alginate hydrogels, however, incorporated 10% w/v of the magnetic microparticles, and the external gelation led to strong implants localizing to the tumor periphery, whereas internal gelation failed in situ. The organogel formulations, which consisted of precipitating polymers dissolved in single organic solvents, displayed various microstructures. A 8% poly(ethylene-vinyl alcohol) in DMSO containing 40% w/v of magnetic microparticles formed the most suitable implants in terms of tumor casting and heat delivery. Importantly, it is of great clinical interest to develop cosolvent formulations with up to 20% w/v of magnetic microparticles that show reduced toxicity and centered tumor implantation.
Resumo:
The biological and therapeutic responses to hyperthermia, when it is envisaged as an anti-tumor treatment modality, are complex and variable. Heat delivery plays a critical role and is counteracted by more or less efficient body cooling, which is largely mediated by blood flow. In the case of magnetically mediated modality, the delivery of the magnetic particles, most often superparamagnetic iron oxide nanoparticles (SPIONs), is also critically involved. We focus here on the magnetic characterization of two injectable formulations able to gel in situ and entrap silica microparticles embedding SPIONs. These formulations have previously shown suitable syringeability and intratumoral distribution in vivo. The first formulation is based on alginate, and the second on a poly(ethylene-co-vinyl alcohol) (EVAL). Here we investigated the magnetic properties and heating capacities in an alternating magnetic field (141 kHz, 12 mT) for implants with increasing concentrations of magnetic microparticles. We found that the magnetic properties of the magnetic microparticles were preserved using the formulation and in the wet implant at 37 degrees C, as in vivo. Using two orthogonal methods, a common SLP (20 Wg(-1)) was found after weighting by magnetic microparticle fraction, suggesting that both formulations are able to properly carry the magnetic microparticles in situ while preserving their magnetic properties and heating capacities. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND: Stem cell labeling with iron oxide (ferumoxide) particles allows labeled cells to be detected by magnetic resonance imaging (MRI) and is commonly used to track stem cell engraftment. However, the validity of MRI for distinguishing surviving ferumoxide-labeled cells from other sources of MRI signal, for example, macrophages containing ferumoxides released from nonsurviving cells, has not been thoroughly investigated. We sought to determine the relationship between the persistence of iron-dependent MRI signals and cell survival 3 weeks after injection of syngeneic or xenogeneic ferumoxides-labeled stem cells (cardiac-derived stem cells) in rats. METHODS AND RESULTS: We studied nonimmunoprivileged human and rat cardiac-derived stem cells and human mesenchymal stem cells doubly labeled with ferumoxides and beta-galactosidase and injected intramyocardially into immunocompetent Wistar-Kyoto rats. Animals were imaged at 2 days and 3 weeks after stem cell injection in a clinical 3-T MRI scanner. At 2 days, injection sites of xenogeneic and syngeneic cells (cardiac-derived stem cells and mesenchymal stem cells) were identified by MRI as large intramyocardial signal voids that persisted at 3 weeks (50% to 90% of initial signal). Histology (at 3 weeks) revealed the presence of iron-containing macrophages at the injection site, identified by CD68 staining, but very few or no beta-galactosidase-positive stem cells in the animals transplanted with syngeneic or xenogeneic cells, respectively. CONCLUSIONS: The persistence of significant iron-dependent MRI signal derived from ferumoxide-containing macrophages despite few or no viable stem cells 3 weeks after transplantation indicates that MRI of ferumoxide-labeled cells does not reliably report long-term stem cell engraftment in the heart.
Resumo:
The aim of the present study was to develop novel daptomycin-loaded acrylic microparticles with improved release profiles and antibacterial activity against two clinically relevant methicillin-susceptible and methicillin-resistant Staphylococcus aureus strains (MSSA and MRSA, respectively). Daptomycin was encapsulated into poly(methyl methacrylate) (PMMA) and PMMA-Eudragit RL 100 (EUD) microparticles by a double emulsion-solvent evaporation method. For comparison purposes similar formulations were prepared with vancomycin. Particle morphology, size distribution, encapsulation efficiency, surface charge, physicochemical properties, in vitro release and biocompatibility were assessed. Particles exhibited a micrometer size and a spherical morphology. The addition of EUD to the formulation caused a shift in the surface charge of the particles from negative zeta potential values (100% PMMA formulations) to strongly positive. It also improved daptomycin encapsulation efficiency and release, whereas vancomycin encapsulation and release were strongly hindered. Plain and antibiotic-loaded particles presented comparable biocompatibility profiles. The antibacterial activity of the particles was assessed by isothermal microcalorimetry against both MSSA and MRSA. Daptomycin-loaded PMMA-EUD particles presented the highest antibacterial activity against both strains. The addition of 30% EUD to the daptomycin-loaded PMMA particles caused a 40- and 20-fold decrease in the minimum inhibitory (MIC) and bactericidal concentration (MBC) values, respectively, when compared to the 100% PMMA formulations. On the other hand, vancomycin-loaded microparticles presented the highest antibacterial activity in PMMA particles. Unlike conventional methods, isothermal microcalorimetry proved to be a real-time, sensitive and accurate method for assessment of antibacterial activity of antibiotic-loaded polymeric microparticles. Finally, the addition of EUD to formulations proved to be a powerful strategy to improve daptomycin encapsulation efficiency and release, and consequently improving the microparticles activity against two relevant S. aureus strains.
Resumo:
OBJECTIVE-We studied whether manganese-enhanced high-field magnetic resonance (MR) imaging (MEHFMRI) could quantitatively detect individual islets in situ and in vivo and evaluate changes in a model of experimental diabetes.RESEARCH DESIGN AND METHODS-Whole pancreata from untreated (n = 3), MnCl(2) and glucose-injected mice (n = 6), and mice injected with either streptozotocin (STZ; n = 4) or citrate buffer (n = 4) were imaged ex vivo for unambiguous evaluation of islets. Exteriorized pancreata of MnCl(2) and glucose-injected mice (n = 6) were imaged in vivo to directly visualize the gland and minimize movements. In all cases, MR images were acquired in a 14.1 Testa scanner and correlated with the corresponding (immuno)histological sections.RESULTS-In ex vivo experiments, MEHFMRI distinguished different pancreatic tissues and evaluated the relative abundance of islets in the pancreata of normoglycemic mice. MEHFMRI also detected a significant decrease in the numerical and volume density of islets in STZ-injected mice. However, in the latter measurements the loss of beta-cells was undervalued under the conditions tested. The experiments on the externalized pancreata confirmed that MEHFMRI could visualize native individual islets in living, anesthetized mice.CONCLUSIONS-Data show that MEHFMRI quantitatively visualizes individual islets in the intact mouse pancreas, both ex vivo and in vivo. Diabetes 60:2853-2860, 2011
Resumo:
To specifically induce a mucosal antibody response to purified human papillomavirus type 16 (HPV16) virus-like particles (VLP), we immunized female BALB/c mice orally, intranasally, and/or parenterally and evaluated cholera toxin (CT) as a mucosal adjuvant. Anti-HPV16 VLP immunoglobulin G (IgG) and IgA titers in serum, saliva, and genital secretions were measured by enzyme-linked immunosorbent assay (ELISA). Systemic immunizations alone induced HPV16 VLP-specific IgG in serum and, to a lesser extent, in genital secretions but no secretory IgA. Oral immunization, even in the presence of CT, was inefficient. However, three nasal immunizations with 5 microgram of VLP given at weekly intervals to anesthetized mice induced high (>10(4)) and long-lasting (>15 weeks) titers of anti-HPV16 VLP antibodies in all samples, including IgA and IgG in saliva and genital secretions. CT enhanced the VLP-specific antibody response 10-fold in serum and to a lesser extent in saliva and genital secretions. Nasal immunization of conscious mice compared to anesthetized mice was inefficient and correlated with the absence of uptake of a marker into the lung. However, a 1-microgram VLP systemic priming followed by two 5-microgram VLP intranasal boosts in conscious mice induced both HPV16 VLP-specific IgG and IgA in secretions, although the titers were lower than in anesthetized mice given three intranasal immunizations. Antibodies in serum, saliva, and genital secretions of immunized mice were strongly neutralizing in vitro (50% neutralization with ELISA titers of 65 to 125). The mucosal and systemic/mucosal HPV16 VLP immunization protocols that induced significant titers of neutralizing IgG and secretory IgA in mucosal secretions in mice may be relevant to genital HPV VLP-based human vaccine trials.
Resumo:
OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.
Resumo:
AIMS: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. METHODS AND RESULTS: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. CONCLUSION: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.
Resumo:
Auditory spatial functions, including the ability to discriminate between the positions of nearby sound sources, are subserved by a large temporo-parieto-frontal network. With the aim of determining whether and when the parietal contribution is critical for auditory spatial discrimination, we applied single pulse transcranial magnetic stimulation on the right parietal cortex 20, 80, 90 and 150 ms post-stimulus onset while participants completed a two-alternative forced choice auditory spatial discrimination task in the left or right hemispace. Our results reveal that transient TMS disruption of right parietal activity impairs spatial discrimination when applied at 20 ms post-stimulus onset for sounds presented in the left (controlateral) hemispace and at 80 ms for sounds presented in the right hemispace. We interpret our finding in terms of a critical role for controlateral temporo-parietal cortices over initial stages of the building-up of auditory spatial representation and for a right hemispheric specialization in integrating the whole auditory space over subsequent, higher-order processing stages.
Resumo:
This work is focused on the development of a methodology for the use of chemical characteristic of tire traces to help answer the following question: "Is the offending tire at the origin of the trace found on the crime scene?". This methodology goes from the trace sampling on the road to statistical analysis of its chemical characteristics. Knowledge about the composition and manufacture of tread tires as well as a review of instrumental techniques used for the analysis of polymeric materials were studied to select, as an ansi vi cal technique for this research, pyrolysis coupled to a gas Chromatograph with a mass spectrometry detector (Py-GC/MS). An analytical method was developed and optimized to obtain the lowest variability between replicates of the same sample. Within-variability of the tread was evaluated regarding width and circumference with several samples taken from twelve tires of different brands and/or models. The variability within each of the treads (within-variability) and between the treads (between-variability) could be quantified. Different statistical methods have shown that within-variability is lower than between-variability, which helped differentiate these tires. Ten tire traces were produced with tires of different brands and/or models by braking tests. These traces have been adequately sampled using sheets of gelatine. Particles of each trace were analysed using the same methodology as for the tires at their origin. The general chemical profile of a trace or of a tire has been characterized by eighty-six compounds. Based on a statistical comparison of the chemical profiles obtained, it has been shown that a tire trace is not differentiable from the tire at its origin but is generally differentiable from tires that are not at its origin. Thereafter, a sample containing sixty tires was analysed to assess the discrimination potential of the developed methodology. The statistical results showed that most of the tires of different brands and models are differentiable. However, tires of the same brand and model with identical characteristics, such as country of manufacture, size and DOT number, are not differentiable. A model, based on a likelihood ratio approach, was chosen to evaluate the results of the comparisons between the chemical profiles of the traces and tires. The methodology developed was finally blindly tested using three simulated scenarios. Each scenario involved a trace of an unknown tire as well as two tires possibly at its origin. The correct results for the three scenarios were used to validate the developed methodology. The different steps of this work were useful to collect the required information to test and validate the underlying assumption that it is possible to help determine if an offending tire » or is not at the origin of a trace, by means of a statistical comparison of their chemical profile. This aid was formalized by a measure of the probative value of the evidence, which is represented by the chemical profile of the trace of the tire. - Ce travail s'est proposé de développer une méthodologie pour l'exploitation des caractéristiques chimiques des traces de pneumatiques dans le but d'aider à répondre à la question suivante : «Est-ce que le pneumatique incriminé est ou n'est pas à l'origine de la trace relevée sur les lieux ? ». Cette méthodologie s'est intéressée du prélèvement de la trace de pneumatique sur la chaussée à l'exploitation statistique de ses caractéristiques chimiques. L'acquisition de connaissances sur la composition et la fabrication de la bande de roulement des pneumatiques ainsi que la revue de techniques instrumentales utilisées pour l'analyse de matériaux polymériques ont permis de choisir, comme technique analytique pour la présente recherche, la pyrolyse couplée à un chromatographe en phase gazeuse avec un détecteur de spectrométrie de masse (Py-GC/MS). Une méthode analytique a été développée et optimisée afin d'obtenir la plus faible variabilité entre les réplicas d'un même échantillon. L'évaluation de l'intravariabilité de la bande de roulement a été entreprise dans sa largeur et sa circonférence à l'aide de plusieurs prélèvements effectués sur douze pneumatiques de marques et/ou modèles différents. La variabilité au sein de chacune des bandes de roulement (intravariabilité) ainsi qu'entre les bandes de roulement considérées (intervariabilité) a pu être quantifiée. Les différentes méthodes statistiques appliquées ont montré que l'intravariabilité est plus faible que l'intervariabilité, ce qui a permis de différencier ces pneumatiques. Dix traces de pneumatiques ont été produites à l'aide de pneumatiques de marques et/ou modèles différents en effectuant des tests de freinage. Ces traces ont pu être adéquatement prélevées à l'aide de feuilles de gélatine. Des particules de chaque trace ont été analysées selon la même méthodologie que pour les pneumatiques à leur origine. Le profil chimique général d'une trace de pneumatique ou d'un pneumatique a été caractérisé à l'aide de huitante-six composés. Sur la base de la comparaison statistique des profils chimiques obtenus, il a pu être montré qu'une trace de pneumatique n'est pas différenciable du pneumatique à son origine mais est, généralement, différenciable des pneumatiques qui ne sont pas à son origine. Par la suite, un échantillonnage comprenant soixante pneumatiques a été analysé afin d'évaluer le potentiel de discrimination de la méthodologie développée. Les méthodes statistiques appliquées ont mis en évidence que des pneumatiques de marques et modèles différents sont, majoritairement, différenciables entre eux. La méthodologie développée présente ainsi un bon potentiel de discrimination. Toutefois, des pneumatiques de la même marque et du même modèle qui présentent des caractéristiques PTD (i.e. pays de fabrication, taille et numéro DOT) identiques ne sont pas différenciables. Un modèle d'évaluation, basé sur une approche dite du likelihood ratio, a été adopté pour apporter une signification au résultat des comparaisons entre les profils chimiques des traces et des pneumatiques. La méthodologie mise en place a finalement été testée à l'aveugle à l'aide de la simulation de trois scénarios. Chaque scénario impliquait une trace de pneumatique inconnue et deux pneumatiques suspectés d'être à l'origine de cette trace. Les résultats corrects obtenus pour les trois scénarios ont permis de valider la méthodologie développée. Les différentes étapes de ce travail ont permis d'acquérir les informations nécessaires au test et à la validation de l'hypothèse fondamentale selon laquelle il est possible d'aider à déterminer si un pneumatique incriminé est ou n'est pas à l'origine d'une trace, par le biais d'une comparaison statistique de leur profil chimique. Cette aide a été formalisée par une mesure de la force probante de l'indice, qui est représenté par le profil chimique de la trace de pneumatique.
Resumo:
Introduction : The redox properties of fine/ultrafine particles as well as nanoparticles (NP) are suggested to be important to explain their biological activity and could constitute a novel and promising metric for hazard evaluation. The acellular in vitro dithiothreitol (DTT) assay allows measuring this property. Objectives : (1) to evaluate sampling requirements for fine/ultrafine particle allowing measurement of their oxidative potential (2) to apply the methodology to occupational situations where particle from combustion sources are generated. Material and method : Sampling parameters (type of filters and loaded amount) and storage duration affecting the DTT measurements were evaluated. Based on these results, a methodological approach was defined and applied in two occupational situations where diesel and other combustion particles are present (toll station in a tunnel and mechanical yard for bus reparation). Results : Teflon filters loaded with diesel particles were found more suitable for the DTT assay, due to their better chemical inertness compared to quartz filters: after storage durations larger than 150 hours, an increased reactivity toward DTT was observed only with quartz filters. Reactivity was linearly correlated to the loaded mass until about 1000 μg/filter. Different redox reactivities were determined in both working places, with the mechanical yard presenting a higher DTT consumption rate. Discussion and conclusions : These results demonstrate the feasibility of this method to determine the oxidative potential of fine/ultrafine particles in occupational situations. We propose to include this approach for hazard assessment of work places with exposure to manufactured and other NP.
Resumo:
PURPOSE: To evaluate the feasibility of visualizing the stent lumen using coronary magnetic resonance angiography in vitro. MATERIAL AND METHODS: Nineteen different coronary stents were implanted in plastic tubes with an inner diameter of 3 mm. The tubes were positioned in a plastic container filled with gel and included in a closed flow circuit (constant flow 18 cm/sec). The magnetic resonance images were obtained with a dual inversion fast spin-echo sequence. For intraluminal stent imaging, subtraction images were calculated from scans with and without flow. Subsequently, intraluminal signal properties were objectively assessed and compared. RESULTS: As a function of the stent type, various degrees of in-stent signal attenuation were observed. Tantalum stents demonstrated minimal intraluminal signal attenuation. For nitinol stents, the stent lumen could be identified, but the intraluminal signal was markedly reduced. Steel stents resulted in the most pronounced intraluminal signal voids. CONCLUSIONS: With the present technique, radiofrequency penetration into the stents is strongly influenced by the stent material. Thesefindings may have important implicationsforfuture stent design and stent imaging strategies.
Resumo:
Over the last decade, there has been a significant increase in the number of high-magnetic-field MRI magnets. However, the exact effect of a high magnetic field strength (B0 ) on diffusion-weighted MR signals is not yet fully understood. The goal of this study was to investigate the influence of different high magnetic field strengths (9.4 T and 14.1 T) and diffusion times (9, 11, 13, 15, 17 and 24 ms) on the diffusion-weighted signal in rat brain white matter. At a short diffusion time (9 ms), fractional anisotropy values were found to be lower at 14.1 T than at 9.4 T, but this difference disappeared at longer diffusion times. A simple two-pool model was used to explain these findings. The model describes the white matter as a first hindered compartment (often associated with the extra-axonal space), characterized by a faster orthogonal diffusion and a lower fractional anisotropy, and a second restricted compartment (often associated with the intra-axonal space), characterized by a slower orthogonal diffusion (i.e. orthogonal to the axon direction) and a higher fractional anisotropy. Apparent T2 relaxation time measurements of the hindered and restricted pools were performed. The shortening of the pseudo-T2 value from the restricted compartment with B0 is likely to be more pronounced than the apparent T2 changes in the hindered compartment. This study suggests that the observed differences in diffusion tensor imaging parameters between the two magnetic field strengths at short diffusion time may be related to differences in the apparent T2 values between the pools. Copyright © 2013 John Wiley & Sons, Ltd.