94 resultados para MEASURING DEVICES
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND AND AIMS: little is known regarding the reproducibility of body fat measuring devices; hence, we assessed the between and within-device reproducibility, and the within-day variability of body fat measurements. METHODS: body fat percentage was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 ± 2.5 kg/m2 (mean ± SD) using seven bipolar bioelectrical impedance devices. Each participant was also measured each hour between 7:00 and 22:00. RESULTS: the correlation between first and second measurements was very high (Spearman r between 0.985 and 1.000, p<0.001), as well as between devices (Spearman r between 0.916 and 0.991, p<0.001). Repeated measurements analysis showed no differences were between devices (p=0.59) or readings (first vs. second: p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon (F test for repeated values= 6.58, p<0.001). CONCLUSIONS: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
OBJECTIVE: Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS: We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mannheim, Germany) in lean (n=15) and obese (n=11) patients. RESULTS: No difference was found in diastolic BP between the two groups, nor between the arm and the wrist. Systolic BP measured at the arm was, however, significantly lower in obese (99+/-9 mmHg, mean+/-SD) than in lean (107+/-14 mmHg; P<0.001) patients, whereas systolic BP determined at the wrist averaged 106 mmHg in both groups. CONCLUSION: The use of validated wrist BP measuring devices appears therefore particularly appealing in obese individuals with a large arm circumference
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
Abstract : The occupational health risk involved with handling nanoparticles is the probability that a worker will experience an adverse health effect: this is calculated as a function of the worker's exposure relative to the potential biological hazard of the material. Addressing the risks of nanoparticles requires therefore knowledge on occupational exposure and the release of nanoparticles into the environment as well as toxicological data. However, information on exposure is currently not systematically collected; therefore this risk assessment lacks quantitative data. This thesis aimed at, first creating the fundamental data necessary for a quantitative assessment and, second, evaluating methods to measure the occupational nanoparticle exposure. The first goal was to determine what is being used where in Swiss industries. This was followed by an evaluation of the adequacy of existing measurement methods to assess workplace nanopaiticle exposure to complex size distributions and concentration gradients. The study was conceived as a series of methodological evaluations aimed at better understanding nanoparticle measurement devices and methods. lt focused on inhalation exposure to airborne particles, as respiration is considered to be the most important entrance pathway for nanoparticles in the body in terms of risk. The targeted survey (pilot study) was conducted as a feasibility study for a later nationwide survey on the handling of nanoparticles and the applications of specific protection means in industry. The study consisted of targeted phone interviews with health and safety officers of Swiss companies that were believed to use or produce nanoparticles. This was followed by a representative survey on the level of nanoparticle usage in Switzerland. lt was designed based on the results of the pilot study. The study was conducted among a representative selection of clients of the Swiss National Accident Insurance Fund (SUVA), covering about 85% of Swiss production companies. The third part of this thesis focused on the methods to measure nanoparticles. Several pre- studies were conducted studying the limits of commonly used measurement devices in the presence of nanoparticle agglomerates, This focus was chosen, because several discussions with users and producers of the measurement devices raised questions about their accuracy measuring nanoparticle agglomerates and because, at the same time, the two survey studies revealed that such powders are frequently used in industry. The first preparatory experiment focused on the accuracy of the scanning mobility particle sizer (SMPS), which showed an improbable size distribution when measuring powders of nanoparticle agglomerates. Furthermore, the thesis includes a series of smaller experiments that took a closer look at problems encountered with other measurement devices in the presence of nanoparticle agglomerates: condensation particle counters (CPC), portable aerosol spectrometer (PAS) a device to estimate the aerodynamic diameter, as well as diffusion size classifiers. Some initial feasibility tests for the efficiency of filter based sampling and subsequent counting of carbon nanotubes (CNT) were conducted last. The pilot study provided a detailed picture of the types and amounts of nanoparticles used and the knowledge of the health and safety experts in the companies. Considerable maximal quantities (> l'000 kg/year per company) of Ag, Al-Ox, Fe-Ox, SiO2, TiO2, and ZnO (mainly first generation particles) were declared by the contacted Swiss companies, The median quantity of handled nanoparticles, however, was 100 kg/year. The representative survey was conducted by contacting by post mail a representative selection of l '626 SUVA-clients (Swiss Accident Insurance Fund). It allowed estimation of the number of companies and workers dealing with nanoparticles in Switzerland. The extrapolation from the surveyed companies to all companies of the Swiss production sector suggested that l'309 workers (95%-confidence interval l'073 to l'545) of the Swiss production sector are potentially exposed to nanoparticles in 586 companies (145 to l'027). These numbers correspond to 0.08% (0.06% to 0.09%) of all workers and to 0.6% (0.2% to 1.1%) of companies in the Swiss production sector. To measure airborne concentrations of sub micrometre-sized particles, a few well known methods exist. However, it was unclear how well the different instruments perform in the presence of the often quite large agglomerates of nanostructured materials. The evaluation of devices and methods focused on nanoparticle agglomerate powders. lt allowed the identification of the following potential sources of inaccurate measurements at workplaces with considerable high concentrations of airborne agglomerates: - A standard SMPS showed bi-modal particle size distributions when measuring large nanoparticle agglomerates. - Differences in the range of a factor of a thousand were shown between diffusion size classifiers and CPC/SMPS. - The comparison between CPC/SMPS and portable aerosol Spectrometer (PAS) was much better, but depending on the concentration, size or type of the powders measured, the differences were still of a high order of magnitude - Specific difficulties and uncertainties in the assessment of workplaces were identified: the background particles can interact with particles created by a process, which make the handling of background concentration difficult. - Electric motors produce high numbers of nanoparticles and confound the measurement of the process-related exposure. Conclusion: The surveys showed that nanoparticles applications exist in many industrial sectors in Switzerland and that some companies already use high quantities of them. The representative survey demonstrated a low prevalence of nanoparticle usage in most branches of the Swiss industry and led to the conclusion that the introduction of applications using nanoparticles (especially outside industrial chemistry) is only beginning. Even though the number of potentially exposed workers was reportedly rather small, it nevertheless underscores the need for exposure assessments. Understanding exposure and how to measure it correctly is very important because the potential health effects of nanornaterials are not yet fully understood. The evaluation showed that many devices and methods of measuring nanoparticles need to be validated for nanoparticles agglomerates before large exposure assessment studies can begin. Zusammenfassung : Das Gesundheitsrisiko von Nanopartikel am Arbeitsplatz ist die Wahrscheinlichkeit dass ein Arbeitnehmer einen möglichen Gesundheitsschaden erleidet wenn er diesem Stoff ausgesetzt ist: sie wird gewöhnlich als Produkt von Schaden mal Exposition gerechnet. Für eine gründliche Abklärung möglicher Risiken von Nanomaterialien müssen also auf der einen Seite Informationen über die Freisetzung von solchen Materialien in die Umwelt vorhanden sein und auf der anderen Seite solche über die Exposition von Arbeitnehmenden. Viele dieser Informationen werden heute noch nicht systematisch gesarnmelt und felilen daher für Risikoanalysen, Die Doktorarbeit hatte als Ziel, die Grundlagen zu schaffen für eine quantitative Schatzung der Exposition gegenüber Nanopartikel am Arbeitsplatz und die Methoden zu evaluieren die zur Messung einer solchen Exposition nötig sind. Die Studie sollte untersuchen, in welchem Ausmass Nanopartikel bereits in der Schweizer Industrie eingesetzt werden, wie viele Arbeitnehrner damit potentiel] in Kontakt komrrien ob die Messtechnologie für die nötigen Arbeitsplatzbelastungsmessungen bereits genügt, Die Studie folcussierte dabei auf Exposition gegenüber luftgetragenen Partikel, weil die Atmung als Haupteintrittspforte iïlr Partikel in den Körper angesehen wird. Die Doktorarbeit besteht baut auf drei Phasen auf eine qualitative Umfrage (Pilotstudie), eine repräsentative, schweizerische Umfrage und mehrere technische Stndien welche dem spezitischen Verständnis der Mëglichkeiten und Grenzen einzelner Messgeräte und - teclmikeri dienen. Die qualitative Telephonumfrage wurde durchgeführt als Vorstudie zu einer nationalen und repräsentativen Umfrage in der Schweizer Industrie. Sie zielte auf Informationen ab zum Vorkommen von Nanopartikeln, und den angewendeten Schutzmassnahmen. Die Studie bestand aus gezielten Telefoninterviews mit Arbeit- und Gesundheitsfachpersonen von Schweizer Unternehmen. Die Untemehmen wurden aufgrund von offentlich zugànglichen lnformationen ausgewählt die darauf hinwiesen, dass sie mit Nanopartikeln umgehen. Der zweite Teil der Dolctorarbeit war die repräsentative Studie zur Evalniernng der Verbreitnng von Nanopaitikelanwendungen in der Schweizer lndustrie. Die Studie baute auf lnformationen der Pilotstudie auf und wurde mit einer repräsentativen Selektion von Firmen der Schweizerischen Unfall Versicherungsanstalt (SUVA) durchgeüihxt. Die Mehrheit der Schweizerischen Unternehmen im lndustrieselctor wurde damit abgedeckt. Der dritte Teil der Doktorarbeit fokussierte auf die Methodik zur Messung von Nanopartikeln. Mehrere Vorstudien wurden dnrchgefîihrt, um die Grenzen von oft eingesetzten Nanopartikelmessgeräten auszuloten, wenn sie grösseren Mengen von Nanopartikel Agglomeraten ausgesetzt messen sollen. Dieser F okns wurde ans zwei Gründen gewählt: weil mehrere Dislcussionen rnit Anwendem und auch dem Produzent der Messgeràte dort eine Schwachstelle vermuten liessen, welche Zweifel an der Genauigkeit der Messgeräte aufkommen liessen und weil in den zwei Umfragestudien ein häufiges Vorkommen von solchen Nanopartikel-Agglomeraten aufgezeigt wurde. i Als erstes widmete sich eine Vorstndie der Genauigkeit des Scanning Mobility Particle Sizer (SMPS). Dieses Messgerät zeigte in Präsenz von Nanopartikel Agglorneraten unsinnige bimodale Partikelgrössenverteilung an. Eine Serie von kurzen Experimenten folgte, welche sich auf andere Messgeräte und deren Probleme beim Messen von Nanopartikel-Agglomeraten konzentrierten. Der Condensation Particle Counter (CPC), der portable aerosol spectrometer (PAS), ein Gerät zur Schàtzung des aerodynamischen Durchniessers von Teilchen, sowie der Diffusion Size Classifier wurden getestet. Einige erste Machbarkeitstests zur Ermittlnng der Effizienz von tilterbasierter Messung von luftgetragenen Carbon Nanotubes (CNT) wnrden als letztes durchgeiührt. Die Pilotstudie hat ein detailliiertes Bild der Typen und Mengen von genutzten Nanopartikel in Schweizer Unternehmen geliefert, und hat den Stand des Wissens der interviewten Gesundheitsschntz und Sicherheitsfachleute aufgezeigt. Folgende Typen von Nanopaitikeln wurden von den kontaktierten Firmen als Maximalmengen angegeben (> 1'000 kg pro Jahr / Unternehrnen): Ag, Al-Ox, Fe-Ox, SiO2, TiO2, und ZnO (hauptsächlich Nanopartikel der ersten Generation). Die Quantitäten von eingesetzten Nanopartikeln waren stark verschieden mit einem ein Median von 100 kg pro Jahr. ln der quantitativen Fragebogenstudie wurden l'626 Unternehmen brieflich kontaktiert; allesamt Klienten der Schweizerischen Unfallversicherringsanstalt (SUVA). Die Resultate der Umfrage erlaubten eine Abschätzung der Anzahl von Unternehmen und Arbeiter, welche Nanopartikel in der Schweiz anwenden. Die Hochrechnung auf den Schweizer lndnstriesektor hat folgendes Bild ergeben: ln 586 Unternehmen (95% Vertrauensintervallz 145 bis 1'027 Unternehmen) sind 1'309 Arbeiter potentiell gegenüber Nanopartikel exponiert (95%-Vl: l'073 bis l'545). Diese Zahlen stehen für 0.6% der Schweizer Unternehmen (95%-Vl: 0.2% bis 1.1%) und 0.08% der Arbeiternehmerschaft (95%-V1: 0.06% bis 0.09%). Es gibt einige gut etablierte Technologien um die Luftkonzentration von Submikrometerpartikel zu messen. Es besteht jedoch Zweifel daran, inwiefern sich diese Technologien auch für die Messurrg von künstlich hergestellten Nanopartikeln verwenden lassen. Aus diesem Grund folcussierten die vorbereitenden Studien für die Arbeitsplatzbeurteilnngen auf die Messung von Pulverri, welche Nan0partike1-Agg10merate enthalten. Sie erlaubten die ldentifikation folgender rnöglicher Quellen von fehlerhaften Messungen an Arbeitsplätzen mit erhöhter Luft-K0nzentrati0n von Nanopartikel Agglomeratenz - Ein Standard SMPS zeigte eine unglaubwürdige bimodale Partikelgrössenverteilung wenn er grössere Nan0par'til<e1Agg10merate gemessen hat. - Grosse Unterschiede im Bereich von Faktor tausend wurden festgestellt zwischen einem Diffusion Size Classiîier und einigen CPC (beziehungsweise dem SMPS). - Die Unterschiede zwischen CPC/SMPS und dem PAS waren geringer, aber abhängig von Grosse oder Typ des gemessenen Pulvers waren sie dennoch in der Grössenordnung von einer guten Grössenordnung. - Spezifische Schwierigkeiten und Unsicherheiten im Bereich von Arbeitsplatzmessungen wurden identitiziert: Hintergrundpartikel können mit Partikeln interagieren die während einem Arbeitsprozess freigesetzt werden. Solche Interaktionen erschweren eine korrekte Einbettung der Hintergrunds-Partikel-Konzentration in die Messdaten. - Elektromotoren produzieren grosse Mengen von Nanopartikeln und können so die Messung der prozessbezogenen Exposition stören. Fazit: Die Umfragen zeigten, dass Nanopartikel bereits Realitàt sind in der Schweizer Industrie und dass einige Unternehmen bereits grosse Mengen davon einsetzen. Die repräsentative Umfrage hat diese explosive Nachricht jedoch etwas moderiert, indem sie aufgezeigt hat, dass die Zahl der Unternehmen in der gesamtschweizerischen Industrie relativ gering ist. In den meisten Branchen (vor allem ausserhalb der Chemischen Industrie) wurden wenig oder keine Anwendungen gefunden, was schliessen last, dass die Einführung dieser neuen Technologie erst am Anfang einer Entwicklung steht. Auch wenn die Zahl der potentiell exponierten Arbeiter immer noch relativ gering ist, so unterstreicht die Studie dennoch die Notwendigkeit von Expositionsmessungen an diesen Arbeitsplätzen. Kenntnisse um die Exposition und das Wissen, wie solche Exposition korrekt zu messen, sind sehr wichtig, vor allem weil die möglichen Auswirkungen auf die Gesundheit noch nicht völlig verstanden sind. Die Evaluation einiger Geräte und Methoden zeigte jedoch, dass hier noch Nachholbedarf herrscht. Bevor grössere Mess-Studien durgefîihrt werden können, müssen die Geräte und Methodem für den Einsatz mit Nanopartikel-Agglomeraten validiert werden.
Resumo:
OBJECTIVES: Advances in biopsychosocial science have underlined the importance of taking social history and life course perspective into consideration in primary care. For both clinical and research purposes, this study aims to develop and validate a standardised instrument measuring both material and social deprivation at an individual level. METHODS: We identified relevant potential questions regarding deprivation using a systematic review, structured interviews, focus group interviews and a think-aloud approach. Item response theory analysis was then used to reduce the length of the 38-item questionnaire and derive the deprivation in primary care questionnaire (DiPCare-Q) index using data obtained from a random sample of 200 patients during their planned visits to an ambulatory general internal medicine clinic. Patients completed the questionnaire a second time over the phone 3 days later to enable us to assess reliability. Content validity of the DiPCare-Q was then assessed by 17 general practitioners. Psychometric properties and validity of the final instrument were investigated in a second set of patients. The DiPCare-Q was administered to a random sample of 1898 patients attending one of 47 different private primary care practices in western Switzerland along with questions on subjective social status, education, source of income, welfare status and subjective poverty. RESULTS: Deprivation was defined in three distinct dimensions: material (eight items), social (five items) and health deprivation (three items). Item consistency was high in both the derivation (Kuder-Richardson Formula 20 (KR20) =0.827) and the validation set (KR20 =0.778). The DiPCare-Q index was reliable (interclass correlation coefficients=0.847) and was correlated to subjective social status (r(s)=-0.539). CONCLUSION: The DiPCare-Q is a rapid, reliable and validated instrument that may prove useful for measuring both material and social deprivation in primary care.
Resumo:
ABSTRACT: BACKGROUND: The dissemination of palliative care for patients presenting complex chronic diseases at various stages has become an important matter of public health. A death census in Swiss long-term care facilities (LTC) was set up with the aim of monitoring the frequency of selected indicators of palliative care. METHODS: The survey covered 150 LTC facilities (105 nursing homes and 45 home health services), each of which was asked to complete a questionnaire for every non-accidental death over a period of six months. The frequency of 4 selected indicators of palliative care (resort to a specialized palliative care service, the administration of opiates, use of any pain measurement scale or other symptom measurement scale) was monitored in respect of the stages of care and analysed based on gender, age, medical condition and place of residence. RESULTS: Overall, 1200 deaths were reported, 29.1% of which were related to cancer. The frequencies of each indicator varied according to the type of LTC, mostly regarding the administration of opiate. It appeared that the access to palliative care remained associated with cancer, terminal care and partly with age, whereas gender and the presence of mental disorders had no effect on the indicators. In addition, the use of drugs was much more frequent than the other indicators. CONCLUSION: The profile of patients with access to palliative care must become more diversified. Among other recommendations, equal access to opiates in nursing homes and in home health services, palliative care at an earlier stage and the systematic use of symptom management scales when resorting to opiates have to become of prime concern.
Resumo:
Background: Temporary percutaneous left ventricular assist devices (TPLVAD) can be inserted and removed in awake patients. They substitute left ventricular function for a period of up to a few weeks and provide an excellent backup and bridge to recovery or decision. Methods: Retrospective analysis of 75 patients who received TPLVAD to treat cardiogenic shock (n = 49) or to facilitate high-risk percutaneous coronary intervention (PCI) (n = 26). Forty-two patients with cardiogenic shock and 16 patients with high-risk PCI received a TandemHeart and 7 patients and 10 patients, respectively, received an Impella Recover LP 2.5. Outcome and related complications up to 1 month are reported with reference to device depending function. Results: One-month survival was 53% in patients with shock and 96% in patients with PCI. Conclusion: TPLVADs can support the failing heart with acceptable risk. Outcome is better in prophylactic use than in patients with cardiogenic shock. (C) 2011 Wiley-Liss, Inc.
Resumo:
OBJECTIVE: To reach a consensus on the clinical use of ambulatory blood pressure monitoring (ABPM). METHODS: A task force on the clinical use of ABPM wrote this overview in preparation for the Seventh International Consensus Conference (23-25 September 1999, Leuven, Belgium). This article was amended to account for opinions aired at the conference and to reflect the common ground reached in the discussions. POINTS OF CONSENSUS: The Riva Rocci/Korotkoff technique, although it is prone to error, is easy and cheap to perform and remains worldwide the standard procedure for measuring blood pressure. ABPM should be performed only with properly validated devices as an accessory to conventional measurement of blood pressure. Ambulatory recording of blood pressure requires considerable investment in equipment and training and its use for screening purposes cannot be recommended. ABPM is most useful for identifying patients with white-coat hypertension (WCH), also known as isolated clinic hypertension, which is arbitrarily defined as a clinic blood pressure of more than 140 mmHg systolic or 90 mmHg diastolic in a patient with daytime ambulatory blood pressure below 135 mmHg systolic and 85 mmHg diastolic. Some experts consider a daytime blood pressure below 130 mmHg systolic and 80 mmHg diastolic optimal. Whether WCH predisposes subjects to sustained hypertension remains debated. However, outcome is better correlated to the ambulatory blood pressure than it is to the conventional blood pressure. Antihypertensive drugs lower the clinic blood pressure in patients with WCH but not the ambulatory blood pressure, and also do not improve prognosis. Nevertheless, WCH should not be left unattended. If no previous cardiovascular complications are present, treatment could be limited to follow-up and hygienic measures, which should also account for risk factors other than hypertension. ABPM is superior to conventional measurement of blood pressure not only for selecting patients for antihypertensive drug treatment but also for assessing the effects both of non-pharmacological and of pharmacological therapy. The ambulatory blood pressure should be reduced by treatment to below the thresholds applied for diagnosing sustained hypertension. ABPM makes the diagnosis and treatment of nocturnal hypertension possible and is especially indicated for patients with borderline hypertension, the elderly, pregnant women, patients with treatment-resistant hypertension and patients with symptoms suggestive of hypotension. In centres with sufficient financial resources, ABPM could become part of the routine assessment of patients with clinic hypertension. For patients with WCH, it should be repeated at annual or 6-monthly intervals. Variation of blood pressure throughout the day can be monitored only by ABPM, but several advantages of the latter technique can also be obtained by self-measurement of blood pressure, a less expensive method that is probably better suited to primary practice and use in developing countries. CONCLUSIONS: ABPM or equivalent methods for tracing the white-coat effect should become part of the routine diagnostic and therapeutic procedures applied to treated and untreated patients with elevated clinic blood pressures. Results of long-term outcome trials should better establish the advantage of further integrating ABPM as an accessory to conventional sphygmomanometry into the routine care of hypertensive patients and should provide more definite information on the long-term cost-effectiveness. Because such trials are not likely to be funded by the pharmaceutical industry, governments and health insurance companies should take responsibility in this regard.
Resumo:
Natural environments are constantly challenged by the release of hydrophobic organic contaminants, which represent a threat for both the ecosystem and human health. Despite a substantial degradation by naturally occurring micro-organisms, a non negligible fraction of these pollutants tend to persist in soil and sediments due to their reduced accessibility to microbial degraders. This lack of 'bioavailability' is acknowledged as a key parameter for the natural and stimulated clean-up (bioremediation) of contaminated sites. We developed a bacterial bioreporter that responds to the presence of polyaromatic hydrocarbons (PAHs) by the production of the green fluorescent protein (GFP), based on the PAH-degrading bacterium Burkholderia sartisoli. We showed in this study that the bacterial biosensor B. sartisoli strain RP037 was faithfully reporting the degradation of naphthalene and phenanthrene (two PAHs of low molecular weight) via the production of GFP. What is more, the magnitude of GFP induction was influenced by change in the PAH flux triggered by a variety of physico-chemical parameters, such as the contact surface between the pollutant and the aqueous suspension. Further experiments permitted to test the influence of dissolved organic matter, which is an important component of natural habitats and can interact with organic pollutants. In addition, we tested the influence of two types of biosurfactants (tensio-active agents produced by living organisms) on phenanthrene's degradation by RP037. Interestingly, the surfactant's effects on the biodegradation rate appeared to depend on the type of biosurfactant and probably on the type of bacterial strain. Finally, we tagged B. sartisoli strain RP037 with a constitutively expressed mCherry fluorescent protein. The presence of mCherry allowed us to visualize the bacteria in complex samples even when GFP production was not induced. The new strain RP037-mChe embedded in a gel patch was used to detect PAH fluxes from a point source, such as a non-aqueous liquid or particles of contaminated soil. In parallel, we also developed and tested a so-called multiwell bacterial biosensor platform, which permitted the simultaneous use of four different reporter strains for the detection of major crude oil components (e.g., saturated hydrocarbons, mono- and polyaromatics) in aqueous samples. We specifically constructed the strain B. sartisoli RP007 (pPROBE-phn-luxAB) for the detection of naphthalene and phenanthrene. It was equipped with a reporter plasmid similar to the one in strain RP037, except that the gfp gene was replaced by the genes luxAB, which encoded the bacterial luciferase. The strain was implemented in the biosensor platform and detected an equivalent naphthalene concentration in oil spilled-sea water. We also cloned the gene for the transcriptional activator AlkS and the operator/promoter region of the operon alkSB1GHJ from the alkane-degrader bacterium Alcanivorax borkumensis strain SK2 in order to construct a new bacterial biosensor with higher sensitivity towards long-chain alkanes. However, the resulting strain showed no increased light emission in presence of tetradecane (C14), while it still efficiently reported low concentrations of octane (C8). RÉSUMÉ : Les écosystèmes naturels sont constamment exposés à nombre de contaminants organiques hydrophobes (COHs) d'origine industrielle, agricole ou même naturelle. Les COHs menacent à la fois l'environnement, le bien-être des espèces animales et végétales et la santé humaine, mais ils peuvent être dégradés par des micro-organismes tels que les bactéries et les champignons, qui peuvent être capables des les transformer en produits inoffensifs comme le gaz carbonique et l'eau. La biodégradation des COHs est cependant fréquemment limitée par leur pauvre disponibilité envers les organismes qui les dégradent. Ainsi, bien que la biodégradation opère partiellement, les COHs persistent dans l'environnement à de faibles concentrations qui potentiellement peuvent encore causer des effets toxiques chroniques. Puisque la plupart des COHs peuvent être métabolisés par l'activité microbienne, leur persistance a généralement pour origine des contraintes physico-chimiques plutôt que biologiques. Par exemple, leur solubilité dans l'eau très limitée réduit leur prise par des consommateurs potentiels. De plus, l'adsorption à la matière organique et la séquestration dans les micropores du sol participent à réduire leur disponibilité envers les microbes. Les processus de biodisponibilité, c'est-à-dire les processus qui gouvernent la dissolution et la prise de polluants par les organismes vivants, sont généralement perçus comme des paramètres clés pour la dépollution (bioremédiation) naturelle et stimulée des sites contaminés. Les hydrocarbures aromatiques polycycliques (HAPs) sont un modèle de COH produits par les activités aussi bien humaines que naturelles, et listés comme des contaminants chroniques de l'air, des sols et des sédiments. Ils peuvent être dégradés par un vaste nombre d'espèces bactériennes mais leur taux de biodégradation est souvent limité par les contraintes mentionnées ci-dessus. Afin de comprendre les processus de biodisponibilité pour les cellules bactériennes, nous avons décidé d'utiliser les bactéries elles-mêmes pour détecter et rapporter les flux de COH. Ceci a été réalisé par l'application d'une stratégie de conception visant à produire des bactéries `biocapteurs-rapporteurs', qui littéralement s'allument lorsqu'elles détectent un composé cible pour lequel elles ont été conçues. En premier lieu, nous nous sommes concentrés sur Burkholderia sartisoli (souche RP007), une bactérie isolée du sol et consommatrice de HAP .Cette souche a servi de base à la construction d'un circuit génétique permettant la formation de la protéine autofluorescente GFP dès que les cellules détectent le naphtalène ou le phénanthrène, deux HAP de faible masse moléculaire. En effet, nous avons pu montrer que la bactérie obtenue, la souche RP037 de B. sartisoli, produit une fluorescence GFP grandissante lors d'une exposition en culture liquide à du phénanthrène sous forme cristalline (0.5 mg par ml de milieu de culture). Nous avons découvert que pour une induction optimale il était nécessaire de fournir aux cellules une source additionnelle de carbone sous la forme d'acétate, ou sinon seul un nombre limité de cellules deviennent induites. Malgré cela, le phénanthrène a induit une réponse très hétérogène au sein de la population de cellules, avec quelques cellules pauvrement induites tandis que d'autres l'étaient très fortement. La raison de cette hétérogénéité extrême, même dans des cultures liquides mélangées, reste pour le moment incertaine. Plus important, nous avons pu montrer que l'amplitude de l'induction de GFP dépendait de paramètres physiques affectant le flux de phénanthrène aux cellules, tels que : la surface de contact entre le phénanthrène solide et la phase aqueuse ; l'ajout de surfactant ; le scellement de phénanthrène à l'intérieur de billes de polymères (Model Polymer Release System) ; la dissolution du phénanthrène dans un fluide gras immiscible à l'eau. Nous en avons conclu que la souche RP037 détecte convenablement des flux de phénantrène et nous avons proposé une relation entre le transfert de masse de phénanthrène et la production de GFP. Nous avons par la suite utilisé la souche afin d'examiner l'effet de plusieurs paramètres chimiques connus dans la littérature pour influencer la biodisponibilité des HAP. Premièrement, les acides humiques. Quelques rapports font état que la disponibilité des HAP pourrait être augmentée par la présence de matière organique dissoute. Nous avons mesuré l'induction de GFP comme fonction de l'exposition des cellules RP037 au phénanthrène ou au naphtalène en présence ou absence d'acides humiques dans la culture. Nous avons testé des concentrations d'acides humiques de 0.1 et 10 mg/L, tandis que le phénanthrène était ajouté via l'heptamethylnonane (HMN), un liquide non aqueux, ce qui au préalable avait produit le plus haut flux constant de phénanthrène aux cellules. De plus, nous avons utilisé des tests en phase gazeuse avec des concentrations d'acides humiques de 0.1, 10 et 1000 mg/L mais avec du naphtalène. Contrairement à ce que décrit la littérature, nos résultats ont indiqué que dans ces conditions l'expression de GFP en fonction de l'exposition au phénanthrène dans des cultures en croissance de la souche RP037 n'était pas modifiée par la présence d'acides humiques. D'un autre côté, le test en phase gazeuse avec du naphtalène a montré que 1000 mg/L d'acides humiques abaissent légèrement mais significativement la production de GFP dans les cellules de RP037. Nous avons conclu qu'il n'y a pas d'effet général des acides humiques sur la disponibilité des HAP pour les bactéries. Par la suite, nous nous sommes demandé si des biosurfactants modifieraient la disponibilité du phénanthrène pour les bactéries. Les surfactants sont souvent décrits dans la littérature comme des moyens d'accroître la biodisponibilité des COHs. Les surfactants sont des agents tensio-actifs qui augmentent la solubilité apparente de COH en les dissolvant à l'intérieur de micelles. Nous avons ainsi testé si des biosurfactants (des surfactants produits par des organismes vivants) peuvent être utilisé pour augmenter la biodisponibilité du phénanthrène pour la souche B. sartisoli RP037. Premièrement, nous avons tenté d'obtenir des biosurfactants produits par une autre bactérie vivant en co-culture avec les biocapteurs bactériens. Deuxièmement, nous avons utilisé des biosurfactants purifiés. La co-cultivation en présence de la bactérie productrice de lipopeptide Pseudomonas putida souche PCL1445 a augmenté l'expression de GFP induite par le phénanthrène chez B. sartisoli en comparaison des cultures simples, mais cet effet n'était pas significativement différent lorsque la souche RP037 était co-cultivée avec un mutant de P. putida ne produisant pas de lipopeptides. L'ajout de lipopeptides partiellement purifiés dans la culture de RP037 a résulté en une réduction de la tension de surface, mais n'a pas provoqué de changement dans l'expression de GFP. D'un autre côté, l'ajout d'une solution commerciale de rhamnolipides (un autre type de biosurfactants produits par Pseudomonas spp.) a facilité la dégradation du phénanthrène par la souche RP037 et induit une expression de GFP élevée dans une plus grande proportion de cellules. Nous avons ainsi conclu que les effets des biosurfactants sont mesurables à l'aide de la souche biocapteur, mais que ceux-ci sont dépendants du type de surfactant utilisé conjointement avec le phénanthrène. La question suivante que nous avons abordée était si les tests utilisant des biocapteurs peuvent être améliorés de manière à ce que les flux de HAP provenant de matériel contaminé soient détectés. Les tests en milieu liquide avec des échantillons de sol ne fournissant pas de mesures, et sachant que les concentrations de HAP dans l'eau sont en général extrêmement basses, nous avons conçu des tests de diffusion dans lesquels nous pouvons étudier l'induction par les HAPs en fonction de la distance aux cellules. Le biocapteur bactérien B. sartisoli souche RP037 a été marqué avec une seconde protéine fluorescente (mCherry), qui est constitutivement exprimée dans les cellules et leur confère une fluorescence rouge/rose. La souche résultante RP037-mChe témoigne d'une fluorescence rouge constitutive mais n'induit la fluorescence verte qu'en présence de naphtalène ou de phénanthrène. La présence d'un marqueur fluorescent constitutif nous permet de visualiser les biocapteurs bactériens plus facilement parmi des particules de sol. Un test de diffusion a été conçu en préparant un gel fait d'une suspension de cellules mélangées à 0.5 % d'agarose. Des bandes de gel de dimensions 0.5 x 2 cm x 1 mm ont été montées dans des chambres d'incubation et exposées à des sources de HAP (soit dissouts dans du HMN ou en tant que matériel solide, puis appliqués à une extrémité de la bande). En utilisant ce montage expérimental, le naphtalène ou le phénanthrène (dissouts dans du HMN à une concentration de 2.5 µg/µl) ont induit un gradient d'intensité de fluorescence GFP après 24 heures d'incubation, tandis que la fluorescence mCherry demeurait comparable. Un sol contaminé par des HAPs (provenant d'un ancien site de production de gaz) a induit la production de GFP à un niveau comparable à celui du naphtalène. Des biocapteurs bactériens individuels ont également détecté un flux de phénanthrène dans un gel contenant des particules de sol amendées avec 1 et 10 mg/g de phénanthrène. Ceci a montré que le test de diffusion peut être utilisé pour mesurer des flux de HAP provenant de matériel contaminé. D'un autre côté, la sensibilité est encore très basse pour plusieurs sols contaminés, et l'autofluorescence de certains échantillons rend difficile l'identification de la réponse de la GFP chez les cellules. Pour terminer, un des points majeurs de ce travail a été la production et la validation d'une plateforme multi-puits de biocapteurs bactériens, qui a permis l'emploi simultané de plusieurs souches différentes de biocapteurs pour la détection des constituants principaux du pétrole. Pour cela nous avons choisi les alcanes linéaires, les composés mono-aromatiques, les biphényls et les composés poly-aromatiques. De plus, nous avons utilisé un capteur pour la génotoxicité afin de détecter la `toxicité globale' dans des échantillons aqueux. Plusieurs efforts d'ingénierie ont été investis de manière à compléter ce set. En premier lieu, chaque souche a été équipée avec soit gfp, soit luxAB en tant que signal rapporteur. Deuxièmement, puisqu'aucune souche de biocapteur n'était disponible pour les HAP ou pour les alcanes à longues chaînes, nous avons spécifiquement construit deux nouveaux biocapteurs. L'un d'eux est également basé sur B. sartisoli RP007, que nous avons équipé avec le plasmide pPROBE-phn-luxAB pour la détection du naphtalène et du phénanthrène mais avec production de luciférase bactérienne. Un autre est un nouveau biocapteur bactérien pour les alcanes. Bien que nous possédions une souche Escherichia coli DHS α (pGEc74, pJAMA7) détectant les alcanes courts de manière satisfaisante, la présence des alcanes à longues chaînes n'était pas rapportée efficacement. Nous avons cloné le gène de l'activateur transcriptionnel A1kS ainsi que la région opérateur/promoteur de l'opéron alkSB1GHJ chez la bactérie dégradant les alcanes Alcanivorax borkumensis souche SK2, afin de construire un nouveau biocapteur bactérien bénéficiant d'une sensibilité accrue envers les alcanes à longues chaînes. Cependant, la souche résultante E. coli DHSα (pAlk3} n'a pas montré d'émission de lumière augmentée en présence de tétradécane (C14), tandis qu'elle rapportait toujours efficacement de basses concentrations d'octane (C8). De manière surprenante, l'utilisation de A. borkumensis en tant que souche hôte pour le nouveau plasmide rapporteur basé sur la GFP a totalement supprimé la sensibilité pour l'octane, tandis que la détection de tétradécane n'était pas accrue. Cet aspect devra être résolu dans de futurs travaux. Pour calibrer la plateforme de biocapteurs, nous avons simulé une fuite de pétrole en mer dans une bouteille en verre ouverte de 5L contenant 2L d'eau de mer contaminée avec 20 ml (1%) de pétrole brut. La phase aqueuse a été échantillonée à intervalles réguliers après la fuite durant une période allant jusqu'à une semaine tandis que les principaux contaminants pétroliers étaient mesurés via les biocapteurs. L'émission de bioluminescence a été mesurée de manière à déterminer la réponse des biocapteurs et une calibration intégrée faite avec des inducteurs types a servi à calculer des concentrations d'équivalents inducteurs dans l'échantillon. E. coli a été utilisée en tant que souche hôte pour la plupart des spécificités des biocapteurs, à l'exception de la détection du naphtalène et du phénanthrène pour lesquels nous avons utilisé B. sartisoli. Cette souche, cependant, peut être employée plus ou moins selon la même procédure. Il est intéressant de noter que le pétrole répandu a produit une apparition séquentielle de composés dissouts dans la phase aqueuse, ceux-ci .étant détectables par les biocapteurs. Ce profil contenait d'abord les alcanes à courtes chaînes et les BTEX (c'est-à dire benzène, toluène, éthylbenzène et xylènes), apparaissant entre des minutes et des heures après que le pétrole a été versé. Leurs concentrations aqueuses ont par la suite fortement décru dans l'eau échantillonnée après 24 heures, à cause de la volatilisation ou de la biodégradation. Après quelques jours d'incubation, ces composés sont devenus indétectables. Les HAPs, en revanche, sont apparus plus tard que les alcanes et les BTEX, et leur concentration a augmenté de pair avec un temps d'incubation prolongé. Aucun signal significatif n'a été mis en évidence avec le biocapteur pour le biphényl ou pour la génotoxicité. Ceci démontre l'utilité de ces biocapteurs, spécifiquement pour la détection des composés pétroliers, comprenant les alcanes à courtes chaînes, les BTEX et les HAPs légers.
Resumo:
Inflammasomes are multiprotein complexes whose activity has been implicated in physiological and pathological inflammation. The hallmarks of inflammasome activation are the secretion of the mature forms of Caspase-1 and IL-1β from cells of the innate immune system. This protocol covers the methods required to study inflammasome activation using mouse bone marrow-derived dendritic cells (BMDCs) as a model system. The protocol includes the generation and handling of BMDCs, the stimulation of BMDCs with established Nlrp3 inflammasome activators, and the measurement of activation by both ELISA and western blot. These methods can be useful for the study of potential inflammasome activators, and of the signaling pathways involved in inflammasome activation. General considerations are provided that may help in the design and optimization of modified methods for the study of other types of inflammasomes and in other cell types.
Resumo:
Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.