5 resultados para MAGNETOHYDRODYNAMICS (MHD)
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND: The assessment of physical activity and energy expenditure is relevant to the care of maintenance haemodialysis (MHD) patients. In the current study, we aimed to evaluate measurements of physical activity and energy expenditure in MHD patients from different centres and countries and explored the predictors of physical activity in these patients.¦METHODS: In this cross-sectional multicentre study, 134 MHD patients from four countries (France, Switzerland, Sweden and Brazil) were included. The physical activity was evaluated for 5.0 ± 1.4 days (mean ± SD) by a multisensory device (SenseWear Armband) and comprised the assessment of number of steps per day, activity-related energy expenditure (activity-related EE) and physical activity level (PAL).¦RESULTS: The number of steps per day, activity-related EE and PAL from the MHD patients were compatible with a sedentary lifestyle. In addition, all parameters were significantly lower in dialysis days when compared to non-dialysis days (P < 0.001). The multivariate regression analysis revealed that diabetes and higher body mass index (BMI) predicted a lower PAL and older age and diabetes predicted a reduced number of steps.¦CONCLUSIONS: The physical activity parameters of MHD patients were compatible with a sedentary lifestyle. This inactivity was worsened by aging, diabetes and higher BMI. Our results indicate that MHD patients should be encouraged by the health care team to increase their physical activity.
Resumo:
Autoantibodies to apolipoprotein/A-1 (anti-ApoA-1 IgG) have pro-atherogenic properties in patients at high cardiovascular risk, but its prevalence in patients with end-stage kidney disease is unknown. The aims of this single-center, cross-sectional study were to assess the prevalence of anti-ApoA-1 antibodies in patients on maintenance hemodialysis (MHD), and to examine its correlation with inflammatory biomarkers related to atherosclerotic plaque vulnerability and dialysis vintage. To this purpose, anti-ApoA-1 IgG levels and the concentrations of interleukin-6 (IL-6), interleukin-8 (IL-8), monocyte chemoattractant protein-1 (MCP-1), metalloproteinase-9 (MMP-9), tumor necrosis factor-α, and C-reactive protein (CRP) were assessed in the sera of 66 MHD patients (mean age: 68 ± 14 years, 36% women, 32% diabetics). Anti-ApoA-1 IgG positivity (defined as a blood value ≥ 97.5(th) percentile of the normal distribution as assessed in healthy blood donors) was 20%. Circulating levels of anti-ApoA-1 IgG correlated positively with dialysis vintage, but not with cardiovascular risk factors or previous cardiovascular events; no significant correlations were found between the anti-ApoA1 IgG levels and circulating levels of IL-6, IL-8, MCP-1, MMP-9, CRP, or low-density lipoprotein-cholesterol. In multivariable linear regression, adjusted for age and sex, only dialysis vintage remained positively and independently associated with anti-ApoA-1 titers (β = 0.05, 95% CI: 0.006; 0.28, P = 0.049). In conclusion, the prevalence of anti-ApoA-1 IgG is raised in the MHD-population, and positively associated with dialysis vintage, a major determinant of cardiovascular outcome. Whether antiApoA-1 antibodies play a role in the pathophysiology of accelerated atherosclerosis in the MHD-population merits further study.
Resumo:
Purpose: The accurate estimation of total energy expenditure (TEE) is essential to allow the provision of nutritional requirements in patients treated by maintenance hemodialysis (MHD). The measurement of TEE and resting energy expenditure (REE) by direct or indirect calorimetry and doubly labeled water are complicated, timeconsuming and cumbersome in this population. Recently, a new system called SenseWear® armband (SWA) was developed to assess TEE, physical activity and REE. This device works by measurements of body acceleration in two axes, heat production and steps counts. REE measured by indirect calorimetry and SWA are well correlated. The aim of this study was to determine TEE, physical activity and REE on patients on MHD using this new device. Methods and materials: Daily TEE, REE, step count, activity time, intensity of activity and lying time were determined for 7 consecutive days in unselected stable patients on MHD and sex, age and weightmatched healthy controls (HC). Patients with malnutrition, cancer, use of immunosuppressive drugs, hypoalbumemia <35 g/L and those hospitalized in the last 3 months, were excluded. For MHD patients, separate analyses were conducted in dialysis and non-dialysis days. Relevant parameters known to affect REE, such as BMI, albumin, pre-albumin, hemoglobin, Kt/V, CRP, bicarbonate, PTH, TSH, were recorded. Results: Thirty patients on MHD and 30 HC were included. In MHD patients, there were 20 men and 10 women. Age was 60,13 years ± 14.97 (mean ± SD), BMI was 25.77 kg/m² ± 4.73 and body weight was 74.65 kg ± 16.16. There were no significant differences between the two groups. TEE was lower in MHD patients compared to HC (28.79 ± 5.51 SD versus 32.91 ± 5.75 SD kcal/kg/day; p <0.01). Activity time was significantly lower in patients on MHD (101.3 ± 12.6SD versus 50.7 ± 9.4 SD min; p = 0.0021). Energy expenditure during the time of activity was significantly lower in MHD patients. MHD patients walked 4543 ± 643 SD vs 8537 ± 744 SD steps per day (p <0.0001). Age was negatively correlated with TEE (r = -0.70) and intensity of activity (r = -0.61) in HC, but not in patients on MHD. TEE showed no difference between dialysis and non-dialysis days (29.92 ± 2.03 SD versus 28.44 ± 1.90 SD kcal/kg/day; p = NS), reflecting a lack of difference in activity (number of steps, time of physical activity) and REE. This finding was observed in MHD patients both older and younger than 60 years. However, age stratification appeared to have an influence on TEE, regardless of dialysis day, (29.92 ± 2.07 SD kcal/kg/day for <60 years-old versus 27.41 ± 1.04 SD kcal/kg/day for ≥60 years old), although failing to reach statistical significance. Conclusion: Using SWA, we have shown that stable patients on MHD have a lower TEE than matched HC. On average, a TEE of 28.79 kcal/kg/day, partially affected by age, was measured. This finding gives support to the clinical impression that it is difficult and probably unnecessary to provide an energy amount of 30-35 kcal/kg/day, as proposed by international guidelines for this population. In addition, we documented for the first time that MHD patients exert a reduced physical activity as compared to HC. There were surprisingly no differences in TEE, REE and physical activity parameters between dialysis and non-dialysis days. This observation might be due to the fact that patients on MHD produce a physical effort to reach the dialysis centre. Age per se did not influence physical activity in MHD patients, contrary to HC, reflecting the impact of co-morbidities on physical activity in this group of patients.
Incidence, complications and risk factors for severe falls in patients on maintenance haemodialysis.
Resumo:
BACKGROUND: Falls have been insufficiently studied in patients on maintenance haemodialysis (MHD). This study assessed the incidence and complications of severe falls and the ability of risk factors, including the Performance-Oriented Mobility Assessment (POMA) test, to predict them in this population. METHODS: All patients on MHD from our centre were asked to participate in this survey. POMA test and a record of risk factors for falls were obtained at baseline. Severe falls, as defined by an admission in an emergency ward, were documented prospectively. RESULTS: Eighty-four patients (median age 69.5 years, minimum 26 years, maximum 85 years) were enrolled. Predialytic POMA scores were low (median 20, minimum 5, maximum 26). After a mean follow-up of 20.6 months (142.2 patient-years), 31 severe falls were recorded in 24 patients (28.6%; incidence 0.22 per patient-year) and complicated by fractures in 54.8% of severe falls. In univariate analysis, age, a past history of falls, malnutrition, depression, but not POMA score, were associated with severe falls. A POMA score of >21 had a negative predictive value of 82%. CONCLUSIONS: Severe falls were common in MHD patients in this study and resulted in fractures in >50% of the cases. They were associated with ageing, a past history of falls, malnutrition and depression. Although there was a trend towards a lower POMA score in fallers as compared to non-fallers, the POMA score was not an independent predictor of severe falls in this study. These data may help to stratify the patient's risk of falling in order to target programmes to prevent falls in this population.
Resumo:
Although physical activity is recommended in patients on maintenance hemodialysis (MHD), randomized controlled trials testing the effects of exercise in this population have given conflicting results. In general, aerobic exercises mostly failed to produce improvements in physical function, whereas resistance exercises, although less studied, appeared to be more promising. The use of sophisticated materials such as leg press and free weights may preclude widespread application of resistance training in patients on MHD. Simple and cheap elastic bands may thus be an attractive alternative. We tested the feasibility of a supervised intradialytic resistance band exercise training program, and its effects on physical function, in patients on MHD. A total of 11 unselected adult patients on MHD from our center, aged 70 ± 10.7 (mean ± standard deviation) years, including 8 men and 3 women, accepted to follow the program under the supervision of qualified physiotherapists. Thirty-six exercise sessions of moderate intensity (twice a week, mean duration 40 minutes each, during 4.5 to 6 months), mainly involving leg muscles against an elastic resistance, were performed. The exercise program was well tolerated and all patients completed it. Statistically significant improvements were observed in the following tests: Tinetti test, 23.9 ± 3.9 points before versus 25.7 ± 3.5 points after the program (P = .022); the Timed Up and Go test, 12.1 ± 6.6 versus 10 ± 5.8 seconds (P = .0156). Improvements in the 6-minute walk distance and in the one-leg balance tests just failed to reach statistical significance. In this single-center pilot study, an intradialytic resistance band exercise program was feasible, well tolerated, and showed encouraging results on physical function.