121 resultados para Linear regression analysis
em Université de Lausanne, Switzerland
Resumo:
X-ray is a technology that is used for numerous applications in the medical field. The process of X-ray projection gives a 2-dimension (2D) grey-level texture from a 3- dimension (3D) object. Until now no clear demonstration or correlation has positioned the 2D texture analysis as a valid indirect evaluation of the 3D microarchitecture. TBS is a new texture parameter based on the measure of the experimental variogram. TBS evaluates the variation between 2D image grey-levels. The aim of this study was to evaluate existing correlations between 3D bone microarchitecture parameters - evaluated from μCT reconstructions - and the TBS value, calculated on 2D projected images. 30 dried human cadaveric vertebrae were acquired on a micro-scanner (eXplorer Locus, GE) at isotropic resolution of 93 μm. 3D vertebral body models were used. The following 3D microarchitecture parameters were used: Bone volume fraction (BV/TV), Trabecular thickness (TbTh), trabecular space (TbSp), trabecular number (TbN) and connectivity density (ConnD). 3D/2D projections has been done by taking into account the Beer-Lambert Law at X-ray energy of 50, 100, 150 KeV. TBS was assessed on 2D projected images. Correlations between TBS and the 3D microarchitecture parameters were evaluated using a linear regression analysis. Paired T-test is used to assess the X-ray energy effects on TBS. Multiple linear regressions (backward) were used to evaluate relationships between TBS and 3D microarchitecture parameters using a bootstrap process. BV/TV of the sample ranged from 18.5 to 37.6% with an average value at 28.8%. Correlations' analysis showedthat TBSwere strongly correlatedwith ConnD(0.856≤r≤0.862; p<0.001),with TbN (0.805≤r≤0.810; p<0.001) and negatively with TbSp (−0.714≤r≤−0.726; p<0.001), regardless X-ray energy. Results show that lower TBS values are related to "degraded" microarchitecture, with low ConnD, low TbN and a high TbSp. The opposite is also true. X-ray energy has no effect onTBS neither on the correlations betweenTBS and the 3Dmicroarchitecture parameters. In this study, we demonstrated that TBS was significantly correlated with 3D microarchitecture parameters ConnD and TbN, and negatively with TbSp, no matter what X-ray energy has been used. This article is part of a Special Issue entitled ECTS 2011. Disclosure of interest: None declared.
Resumo:
Background/objectives:Bioelectrical impedance analysis (BIA) is used in population and clinical studies as a technique for estimating body composition. Because of significant under-representation in existing literature, we sought to develop and validate predictive equation(s) for BIA for studies in populations of African origin.Subjects/methods:Among five cohorts of the Modeling the Epidemiologic Transition Study, height, weight, waist circumference and body composition, using isotope dilution, were measured in 362 adults, ages 25-45 with mean body mass indexes ranging from 24 to 32. BIA measures of resistance and reactance were measured using tetrapolar placement of electrodes and the same model of analyzer across sites (BIA 101Q, RJL Systems). Multiple linear regression analysis was used to develop equations for predicting fat-free mass (FFM), as measured by isotope dilution; covariates included sex, age, waist, reactance and height(2)/resistance, along with dummy variables for each site. Developed equations were then tested in a validation sample; FFM predicted by previously published equations were tested in the total sample.Results:A site-combined equation and site-specific equations were developed. The mean differences between FFM (reference) and FFM predicted by the study-derived equations were between 0.4 and 0.6âeuro0/00kg (that is, 1% difference between the actual and predicted FFM), and the measured and predicted values were highly correlated. The site-combined equation performed slightly better than the site-specific equations and the previously published equations.Conclusions:Relatively small differences exist between BIA equations to estimate FFM, whether study-derived or published equations, although the site-combined equation performed slightly better than others. The study-derived equations provide an important tool for research in these understudied populations.
Resumo:
Aim This study used data from temperate forest communities to assess: (1) five different stepwise selection methods with generalized additive models, (2) the effect of weighting absences to ensure a prevalence of 0.5, (3) the effect of limiting absences beyond the environmental envelope defined by presences, (4) four different methods for incorporating spatial autocorrelation, and (5) the effect of integrating an interaction factor defined by a regression tree on the residuals of an initial environmental model. Location State of Vaud, western Switzerland. Methods Generalized additive models (GAMs) were fitted using the grasp package (generalized regression analysis and spatial predictions, http://www.cscf.ch/grasp). Results Model selection based on cross-validation appeared to be the best compromise between model stability and performance (parsimony) among the five methods tested. Weighting absences returned models that perform better than models fitted with the original sample prevalence. This appeared to be mainly due to the impact of very low prevalence values on evaluation statistics. Removing zeroes beyond the range of presences on main environmental gradients changed the set of selected predictors, and potentially their response curve shape. Moreover, removing zeroes slightly improved model performance and stability when compared with the baseline model on the same data set. Incorporating a spatial trend predictor improved model performance and stability significantly. Even better models were obtained when including local spatial autocorrelation. A novel approach to include interactions proved to be an efficient way to account for interactions between all predictors at once. Main conclusions Models and spatial predictions of 18 forest communities were significantly improved by using either: (1) cross-validation as a model selection method, (2) weighted absences, (3) limited absences, (4) predictors accounting for spatial autocorrelation, or (5) a factor variable accounting for interactions between all predictors. The final choice of model strategy should depend on the nature of the available data and the specific study aims. Statistical evaluation is useful in searching for the best modelling practice. However, one should not neglect to consider the shapes and interpretability of response curves, as well as the resulting spatial predictions in the final assessment.
Resumo:
Many of the most interesting questions ecologists ask lead to analyses of spatial data. Yet, perhaps confused by the large number of statistical models and fitting methods available, many ecologists seem to believe this is best left to specialists. Here, we describe the issues that need consideration when analysing spatial data and illustrate these using simulation studies. Our comparative analysis involves using methods including generalized least squares, spatial filters, wavelet revised models, conditional autoregressive models and generalized additive mixed models to estimate regression coefficients from synthetic but realistic data sets, including some which violate standard regression assumptions. We assess the performance of each method using two measures and using statistical error rates for model selection. Methods that performed well included generalized least squares family of models and a Bayesian implementation of the conditional auto-regressive model. Ordinary least squares also performed adequately in the absence of model selection, but had poorly controlled Type I error rates and so did not show the improvements in performance under model selection when using the above methods. Removing large-scale spatial trends in the response led to poor performance. These are empirical results; hence extrapolation of these findings to other situations should be performed cautiously. Nevertheless, our simulation-based approach provides much stronger evidence for comparative analysis than assessments based on single or small numbers of data sets, and should be considered a necessary foundation for statements of this type in future.
Resumo:
Uromodulin is expressed exclusively in the thick ascending limb and is the most abundant protein excreted in normal urine. Variants in UMOD, which encodes uromodulin, are associated with renal function, and urinary uromodulin levels may be a biomarker for kidney disease. However, the genetic factors regulating uromodulin excretion are unknown. We conducted a meta-analysis of urinary uromodulin levels to identify associated common genetic variants in the general population. We included 10,884 individuals of European descent from three genetic isolates and three urban cohorts. Each study measured uromodulin indexed to creatinine and conducted linear regression analysis of approximately 2.5 million single nucleotide polymorphisms using an additive model. We also tested whether variants in genes expressed in the thick ascending limb associate with uromodulin levels. rs12917707, located near UMOD and previously associated with renal function and CKD, had the strongest association with urinary uromodulin levels (P<0.001). In all cohorts, carriers of a G allele of this variant had higher uromodulin levels than noncarriers did (geometric means 10.24, 14.05, and 17.67 μg/g creatinine for zero, one, or two copies of the G allele). rs12446492 in the adjacent gene PDILT (protein disulfide isomerase-like, testis expressed) also reached genome-wide significance (P<0.001). Regarding genes expressed in the thick ascending limb, variants in KCNJ1, SORL1, and CAB39 associated with urinary uromodulin levels. These data indicate that common variants in the UMOD promoter region may influence urinary uromodulin levels. They also provide insights into uromodulin biology and the association of UMOD variants with renal function.
Resumo:
Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.
Resumo:
This study aimed at identifying clinical factors for predicting hematologic toxicity after radioimmunotherapy with (90)Y-ibritumomab tiuxetan or (131)I-tositumomab in clinical practice. Hematologic data were available from 14 non-Hodgkin lymphoma patients treated with (90)Y-ibritumomab tiuxetan and 18 who received (131)I-tositumomab. The percentage baseline at nadir and 4 wk post nadir and the time to nadir were selected as the toxicity indicators for both platelets and neutrophils. Multiple linear regression analysis was performed to identify significant predictors (P < 0.05) of each indicator. For both platelets and neutrophils, pooled and separate analyses of (90)Y-ibritumomab tiuxetan and (131)I-tositumomab data yielded the time elapsed since the last chemotherapy as the only significant predictor of the percentage baseline at nadir. The extent of bone marrow involvement was not a significant factor in this study, possibly because of the short time elapsed since the last chemotherapy of the 7 patients with bone marrow involvement. Because both treatments were designed to deliver a comparable bone marrow dose, this factor also was not significant. None of the 14 factors considered was predictive of the time to nadir. The R(2) value for the model predicting percentage baseline at nadir was 0.60 for platelets and 0.40 for neutrophils. This model predicted the platelet and neutrophil toxicity grade to within ±1 for 28 and 30 of the 32 patients, respectively. For the 7 patients predicted with grade I thrombocytopenia, 6 of whom had actual grade I-II, dosing might be increased to improve treatment efficacy. The elapsed time since the last chemotherapy can be used to predict hematologic toxicity and customize the current dosing method in radioimmunotherapy.
Resumo:
AIMS: In patients with alcohol dependence, health-related quality of life (QOL) is reduced compared with that of a normal healthy population. The objective of the current analysis was to describe the evolution of health-related QOL in adults with alcohol dependence during a 24-month period after initial assessment for alcohol-related treatment in a routine practice setting, and its relation to drinking pattern which was evaluated across clusters based on the predominant pattern of alcohol use, set against the influence of baseline variables METHODS: The Medical Outcomes Study 36-Item Short-Form Survey (MOS-SF-36) was used to measure QOL at baseline and quarterly for 2 years among participants in CONTROL, a prospective observational study of patients initiating treatment for alcohol dependence. The sample consisted of 160 adults with alcohol dependence (65.6% males) with a mean (SD) age of 45.6 (12.0) years. Alcohol use data were collected using TimeLine Follow-Back. Based on the participant's reported alcohol use, three clusters were identified: 52 (32.5%) mostly abstainers, 64 (40.0%) mostly moderate drinkers and 44 (27.5%) mostly heavy drinkers. Mixed-effect linear regression analysis was used to identify factors that were potentially associated with the mental and physical summary MOS-SF-36 scores at each time point. RESULTS: The mean (SD) MOS-SF-36 mental component summary score (range 0-100, norm 50) was 35.7 (13.6) at baseline [mostly abstainers: 40.4 (14.6); mostly moderate drinkers 35.6 (12.4); mostly heavy drinkers 30.1 (12.1)]. The score improved to 43.1 (13.4) at 3 months [mostly abstainers: 47.4 (12.3); mostly moderate drinkers 44.2 (12.7); mostly heavy drinkers 35.1 (12.9)], to 47.3 (11.4) at 12 months [mostly abstainers: 51.7 (9.7); mostly moderate drinkers 44.8 (11.9); mostly heavy drinkers 44.1 (11.3)], and to 46.6 (11.1) at 24 months [mostly abstainers: 49.2 (11.6); mostly moderate drinkers 45.7 (11.9); mostly heavy drinkers 43.7 (8.8)]. Mixed-effect linear regression multivariate analyses indicated that there was a significant association between a lower 2-year follow-up MOS-SF-36 mental score and being a mostly heavy drinker (-6.97, P < 0.001) or mostly moderate drinker (-3.34 points, P = 0.018) [compared to mostly abstainers], being female (-3.73, P = 0.004), and having a Beck Inventory scale score ≥8 (-6.54, P < 0.001), at baseline. The mean (SD) MOS-SF-36 physical component summary score was 48.8 (10.6) at baseline, remained stable over the follow-up and did not differ across the three clusters. Mixed-effect linear regression univariate analyses found that the average 2-year follow-up MOS-SF-36 physical score was increased (compared with mostly abstainers) in mostly heavy drinkers (+4.44, P = 0.007); no other variables tested influenced the MOS-SF-36 physical score. CONCLUSION: Among individuals with alcohol dependence, a rapid improvement was seen in the mental dimension of QOL following treatment initiation, which was maintained during 24 months. Improvement was associated with the pattern of alcohol use, becoming close to the general population norm in patients classified as mostly abstainers, improving substantially in mostly moderate drinkers and improving only slightly in mostly heavy drinkers. The physical dimension of QOL was generally in the normal range but was not associated with drinking patterns.
Resumo:
Objective: To produce age-related normograms for serum antimullerian hormone (AMH) level in infertile women without polycystic ovaries (non-PCO).Design: Retrospective cohort analysis.Setting: Fifteen academic reproductive centers.Patient(s): A total of 3,871 infertile women.Intervention(s): Blood sampling for AMH level.Main Outcome Measure(s): Serum AMH levels and correlation between age and different percentiles of AMH.Result(s): Age-related normograms for the 3rd, 10th, 25th, 50th, 75th, 90th, and 97th percentiles of AMH were produced. We found that the curves of AMH by age for the 3rd to 50th percentiles fit the model and appearance of linear relation, whereas the curves of >75th percentiles fit cubic relation. There were significant differences in AMH and FSH levels and in antral follicle count (AFC) among women aged 24-33 years, 34-38 years, and >= 39 years. Multivariate stepwise linear regression analysis of FSH, age, AFC, and the type of AMH kit as predictors of AMH level shows that all variables are independently associated with AMH level, in the following order: AFC, FSH, type of AMH kit, and age.Conclusion(s): Age-related normograms in non-PCO infertile women for the 3rd to 97th percentiles were produced. These normograms could provide a reference guide for the clinician to consult women with infertility. However, future validation with longitudinal data is still needed. (Fertil Steril (R) 2011; 95: 2359-63. (C) 2011 by American Society for Reproductive Medicine.)
Resumo:
AIM: To evaluate the incidence of late biliary complications in non-resectable alveolar echinococcosis (AE) under long-term chemotherapy with benzimidazoles. METHODS: Retrospective analysis of AE patients with biliary complications occurring more than three years after the diagnosis of AE. We compared characteristics of patients with and without biliary complications, analyzed potential risk factor for biliary complications and performed survival analyses. RESULTS: Ninety four of 148 patients with AE in Zurich had non-resectable AE requiring long-term benzimidazole chemotherapy, of which 26 (28%) patients developed late biliary complications. These patients had a median age of 55.5 (35.5-65) years at diagnosis of AE and developed biliary complications after 15 (8.25-19) years of chemotherapy. The most common biliary complications during long-term chemotherapy were late-onset cholangitis (n = 14), sclerosing cholangitis-like lesions (n = 8), hepatolithiasis (n = 5), affection of the common bile duct (n = 7) and secondary biliary cirrhosis (n = 7). Thirteen of the 26 patients had undergone surgery (including 12 resections) before chemotherapy. Previous surgery was a risk factor for late biliary complications in linear regression analysis (P = 0.012). CONCLUSION: Late biliary complications can be observed in nearly one third of patients with non-resectable AE, with previous surgery being a potential risk factor. After the occurrence of late biliary complications, the median survival is only 3 years, suggesting that late biliary complications indicate a poor prognostic outcome.
Resumo:
RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.
Resumo:
Little information exists regarding the effect of several obesity markers on blood pressure (BP) levels in youth. Transverse study including 2494 boys and 2589 girls. Height, weight and waist were measured according to the international criteria and body fat (BF) by bioimpedance. BP was measured by an automated device. Hypertension was defined using sex-specific, age-specific and height-specific observation-points. Body mass index (BMI) and waist were positively related with systolic blood pressure (SBP) and diastolic blood pressure (DBP) and heart rate in both sexes, whereas the relationships with BF were less consistent. Stepwise linear regression analysis showed that BMI was positively related with SBP and DBP in both sexes, whereas BF was negatively related with SBP in both sexes and with heart rate in boys only; finally, waist was positively related with SBP in boys and heart rate in girls. Age and heart rate-adjusted values of SBP and DBP increased with BMI: for SBP, 117+/-1, 123+/-1 and 124+/-1 mmHg in normal, overweight and obese boys, respectively; corresponding values for girls were 111+/-1, 114+/-1 and 116+/-2 mmHg (mean+/-SE, P<0.001). Overweight and obese boys had an odds ratio for being hypertensive of 2.26 (95% confidence interval: 1.79-2.86) and 3.36 (2.32-4.87), respectively; corresponding values for girls were 1.58 (confidence interval 1.25-1.99) and 2.31 (1.53-3.50). BMI, not BF or waist, is consistently and independently related to BP levels in children; overweight and obesity considerably increase the risk of hypertension.
Resumo:
BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.
Resumo:
ABSTRACT: BACKGROUND: There is little information regarding the trends in body mass index (BMI) and obesity in the overall Portuguese population, namely if these trends are similar according to educational level. In this study, we assessed the trends in the prevalence of overweight and obesity in the Portuguese population, overall and by educational level. METHODS: Cross-sectional national health interview surveys conducted in 1995-6 (n=38,504), 1998-9 (n=38,688) and 2005-6 (n=25,348). Data were derived from the population and housing census of 1991 and two geographically-based strata were defined. The sampling unit was the house, and all subjects living in the sampling unit were surveyed. Height and weight were self-reported; the effects of gender, age group and educational level were also assessed by self-reported structured questionnaires. Bivariate comparisons were performed using Chi-square or analysis of variance (ANOVA). Trends in BMI levels were assessed by linear regression analysis, while trends in the prevalence of obesity were assessed by logistic regression. RESULTS: Mean (+/-standard deviation) BMI increased from 25.2+/-4.0 in 1995-6 to 25.7+/-4.5 kg/m2 in 2005-6. Prevalence of overweight remained stable (36.1% in 1995-6 and 36.4% in 2005) while prevalence of obesity increased (11.5% in 1995-6 and 15.1% in 2005-6). Similar findings were observed according to age group. Mean age-adjusted BMI increase (expressed in kg/m2/year and 95% confidence interval) was 0.073 (0.062, 0.084), 0.016 (0.000, 0.031) and 0.073 (0.049, 0.098) in men with primary, secondary and university levels, respectively; the corresponding values in women were 0.085 (0.073, 0.097), 0.052 (0.035, 0.069) and 0.062 (0.038, 0.084). Relative to 1995-6, obesity rates increased by 48%, 41% and 59% in men and by 40%, 75% and 177% in women with primary, secondary and university levels, respectively. The corresponding values for overweight were 6%, 1% and 23% in men and 5%, 7% and 65% in women. CONCLUSION: Between 1995 and 2005, obesity increased while overweight remained stable in the adult Portuguese population. Although higher rates were found among lesser educated subjects, the strong increase in BMI and obesity levels in highly educated subjects is of concern.
Resumo:
Background. Age is an important risk factor for perioperative cerebral complications such as stroke, postoperative cognitive dysfunction, and delirium. We explored the hypothesis that intraoperative cerebrovascular autoregulation is less efficient and brain tissue oxygenation lower in elderly patients, thus, increasing the vulnerability of elderly brains to systemic insults such as hypotension.Methods. We monitored intraoperative cerebral perfusion in 50 patients aged 18-40 and 77 patients >65 yr at two Swiss university hospitals. Mean arterial pressure (MAP) was measured continuously using a plethysmographic method. An index of cerebrovascular autoregulation (Mx) was calculated based on changes in transcranial Doppler flow velocity due to changes in MAP. Cerebral oxygenation was assessed by the tissue oxygenation index (TOI) using near-infrared spectroscopy. End-tidal CO(2), O(2), and sevoflurane concentrations and peripheral oxygen saturation were recorded continuously. Standardized anaesthesia was administered in all patients (thiopental, sevoflurane, fentanyl, atracurium).Results. Autoregulation was less efficient in patients aged >65 yr [by 0.10 (SE 0.04; P=0.020)] in a multivariable linear regression analysis. This difference was not attributable to differences in MAP, end-tidal CO2, or higher doses of sevoflurane. TOI was not significantly associated with age, sevoflurane dose, or Mx but increased with increasing flow velocity [by 0.09 (SE 0.04; P=0.028)] and increasing MAP [by 0.11 (SE 0.05; P=0.043)].Conclusions. Our results do not support the hypothesis that older patients' brains are more vulnerable to systemic insults. The difference of autoregulation between the two groups was small and most likely clinically insignificant.