BACKGROUND: Reading volume and mammography screening performance appear positively correlated. Quality and effectiveness were compared across low-volume screening programmes targeting relatively small populations and operating under the same decentralised healthcare system. Except for accreditation of 2nd readers (restrictive vs non-restrictive strategy), these organised programmes had similar screening regimen/procedures and duration, which maximises comparability. Variation in performance and its determinants were explored in order to improve mammography practice and optimise screening performance. METHODS: Circa 200,000 screens performed between 1999 and 2006 (4 rounds) in 3 longest standing Swiss cantonal programmes (of Vaud, Geneva and Valais) were assessed. Indicators of quality and effectiveness were assessed according to European standards. Interval cancers were identified through linkage with cancer registries records. RESULTS: Swiss programmes met most European standards of performance with a substantial, favourable cancer stage shift. Up to a two-fold variation occurred for several performance indicators. In subsequent rounds, compared with programmes (Vaud and Geneva) that applied a restrictive selection strategy for 2nd readers, proportions of in situ lesions and of small cancers (≤1cm) were one third lower and halved, respectively, and the proportion of advanced lesions (stage II+) nearly 50% higher in the programme without a restrictive selection strategy. Discrepancy in second-year proportional incidence of interval cancers appears to be multicausal. CONCLUSION: Differences in performance could partly be explained by a selective strategy for second readers and a prior experience in service screening, but not by the levels of opportunistic screening and programme attendance. This study provides clues for enhancing mammography screening performance in low-volume programmes.
Resumo:
BACKGROUND: In numerous high-risk medical and surgical conditions, a greater volume of patients undergoing treatment in a given setting or facility is associated with better survival. For patients with pulmonary embolism, the relation between the number of patients treated in a hospital (volume) and patient outcome is unknown. METHODS: We studied discharge records from 186 acute care hospitals in Pennsylvania for a total of 15 531 patients for whom the primary diagnosis was pulmonary embolism. The study outcomes were all-cause mortality in hospital and within 30 days after presentation for pulmonary embolism and the length of hospital stay. We used logistic models to study the association between hospital volume and 30-day mortality and discrete survival models to study the association between in-hospital mortality and time to hospital discharge. RESULTS: The median annual hospital volume for pulmonary embolism was 20 patients (interquartile range 10-42). Overall in-hospital mortality was 6.0%, whereas 30-day mortality was 9.3%. In multivariable analysis, very-high-volume hospitals (> or = 42 cases per year) had a significantly lower odds of in-hospital death (odds ratio [OR] 0.71, 95% confidence interval [CI] 0.51-0.99) and of 30-day death (OR 0.71, 95% CI 0.54-0.92) than very-low-volume hospitals (< 10 cases per year). Although patients in the very-high-volume hospitals had a slightly longer length of stay than those in the very-low-volume hospitals (mean difference 0.7 days), there was no association between volume and length of stay. INTERPRETATION: In hospitals with a high volume of cases, pulmonary embolism was associated with lower short-term mortality. Further research is required to determine the causes of the relation between volume and outcome for patients with pulmonary embolism.
Resumo:
Coagulopathy and alveolar fibrin deposition are common in sick neonates and attributed to the primary disease, as opposed to their ventilatory support. Hypothesizing that high tidal volume ventilation activates the extrinsic coagulation pathway, we air ventilated newborn and adult rats at low (10 ml/kg) or high (30 ml/kg) tidal volume and compared them with age-matched nonventilated controls. Blood was collected at the end of the experiment for measurement of clot time, tissue factor, and other coagulation factor content. Similar measurements were obtained from lung lavage material. The newborn clot time (44+/-1) was lower and plasma tissue factor content higher (103.4+/-0.4) than adults (88+/-4 s and 26.6+/-1.4 units; P<0.01). High, but not low, tidal volume ventilation of newborns for as little as 15 min significantly reduced clot time and increased plasma tissue factor content (P<0.01). High volume ventilation increased plasma factor Xa (0.1+/-0.1 to 1.6+/-0.4 nM; P<0.01) and thrombin (1.3+/-0.2 to 2.2+/-0.4 nM; P<0.05) and decreased antithrombin (0.12+/-0.01 to 0.05+/-0.01; P<0.01) in the newborn. Lung lavage material of high volume-ventilated newborns showed increased (P<0.01) factor Xa and thrombin. No changes in these parameters were observed in adult rats that were high volume ventilated for up to 90 min. Compared with adults, newborn rats have a greater propensity for volutrauma-activated intravascular coagulation. These data suggest that mechanical ventilation promotes neonatal thrombosis via lung tissue factor release.
Resumo:
BACKGROUND: An association between alcohol consumption and injury is clearly established from volume of drinking, heavy episodic drinking (HED), and consumption before injury. Little is known, however, about how their interaction raises risk of injury and what combination of factors carries the highest risk. This study explores which of 11 specified groups of drinkers (a) are at high risk and (b) contribute most to alcohol-attributable injuries. METHODS: In all, 8,736 patients, of whom 5,077 were injured, admitted to the surgical ward of the emergency department of Lausanne University Hospital between January 1, 2003, and June 30, 2004, were screened for alcohol use. Eleven groups were constructed on the basis of usual patterns of intake and preattendance drinking. Odds ratios (ORs) comparing injured and noninjured were derived, and alcohol-attributable fractions of injuries were calculated from ORs and prevalence of exposure groups. RESULTS: Risk of injury increased with volume of drinking, HED, and preattendance drinking. For both sexes, the highest risk was associated with low intake, HED, and 4 (women), 5 (men), or more drinks before injury. At the same level of preattendance drinking, high-volume drinkers were at lower risk than low-volume drinkers. In women, the group of low-risk non-HED drinkers taking fewer than 4 drinks suffered 47.5% of the alcohol-attributable injuries in contrast to only 20.4% for men. Low-volume male drinkers with HED had more alcohol-attributable injuries than that of low-volume female drinkers with HED (46.9% vs 23.2%). CONCLUSIONS: Although all groups of drinkers are at increased risk of alcohol-related injury, those who usually drink little but on occasion heavily are at particular risk. The lower risk of chronic heavy drinkers may be due to higher tolerance of alcohol. Prevention should thus target heavy-drinking occasions. Low-volume drinking women without HED and with only little preattendance drinking experienced a high proportion of injuries; such women would be well advised to drink very little or to take other special precautions in risky circumstances.
Resumo:
OBJECTIVES:: For certain major operations, inpatient mortality risk is lower in high-volume hospitals than those in low-volume hospitals. Extending the analysis to a broader range of interventions and outcomes is necessary before adopting policies based on minimum volume thresholds. METHODS:: Using the United States 2004 Nationwide Inpatient Sample, we assessed the effect of intervention-specific and overall hospital volume on surgical complications, potentially avoidable reoperations, and deaths across 1.4 million interventions in 353 hospitals. Outcome variations across hospitals were analyzed through a 3-level hierarchical logistic regression model (patients, surgical interventions, and hospitals), which took into account interventions on multiple organs, 144 intervention categories, and structural hospital characteristics. Discriminative performance and calibration were good. RESULTS:: Hospitals with more experience in a given intervention had similar reoperation rates but lower mortality and complication rates: odds ratio per volume deciles 0.93 and 0.97. However, the benefit was limited to heart surgery and a small number of other operations. Risks were higher for hospitals that performed more interventions overall: odds ratio per 1000 for each event was approximately 1.02. Even after adjustment for specific volume, mortality varied substantially across both high- and low-volume hospitals. CONCLUSION:: Although the link between specific volume and certain inpatient outcomes suggests that specialization might help improve surgical safety, the variable magnitude of this link and the heterogeneity of hospital effect do not support the systematic use of volume-based referrals. It may be more efficient to monitor risk-adjusted postoperative outcomes and to investigate facilities with worse than expected outcomes.
Resumo:
PURPOSE: Low tidal volume ventilation and permissive hypercapnia are required in patients with sepsis complicated by ARDS. The effects of hypercapnia on tissue oxidative metabolism in this setting are unknown. We therefore determined the effects of moderate hypercapnia on markers of systemic and splanchnic oxidative metabolism in an animal model of endotoxemia. METHODS: Anesthetized rats maintained at a PaCO(2) of 30, 40 or 60 mmHg were challenged with endotoxin. A control group (PaCO(2) 40 mmHg) received isotonic saline. Hemodynamic variables, arterial lactate, pyruvate, and ketone bodies were measured at baseline and after 4 h. Tissue adenosine triphosphate (ATP) and lactate were measured in the small intestine and the liver after 4 h. RESULTS: Endotoxin resulted in low cardiac output, increased lactate/pyruvate ratio and decreased ketone body ratio. These changes were not influenced by hypercapnia, but were more severe with hypocapnia. In the liver, ATP decreased and lactate increased independently from PaCO(2) after endotoxin. In contrast, the drop of ATP and the rise in lactate triggered by endotoxin in the intestine were prevented by hypercapnia. CONCLUSIONS: During endotoxemia in rats, moderate hypercapnia prevents the deterioration of tissue energetics in the intestine.
Resumo:
BACKGROUND: The European Guidelines specify a minimum of 5,000 screening cases to be read yearly by radiologists carrying out second reading in non-centralized programs. This professional requirement is difficult to reach and/or to implement in regional programs covering a sparse population with a high number of participating radiology units, so that alternative blind double reading strategies must be devised. OBJECTIVE: To evaluate the effect on breast cancer screening performances of two second reading strategies used in non-centralized, low-volume programs. METHODS: Reading performances in two Swiss regional breast cancer screening programs (cantons of Wallis and Vaud), covering female populations, aged 50-69, of about 31'000 and 72'000 inhabitants were computed and compared. Both programs had similar screening regimens and organizations, but differed with respect to second reading. One setting applied a selective strategy whereby only experienced radiologists performed second reading; the other elicited not to restrict second readers on the basis of their individual screening activity. Analysis included some 140,000 mammograms performed between 1999 and 2005. RESULTS: Overall, screening performances improved with increasing total volume of reading, albeit not in a linear fashion. Regardless of setting, radiologists attained a higher level of screening accuracy when performing second rather than first readings, and incident rather than prevalent screening cases. The effect of a selective, small group of second readers appeared to impact favorably on the false-positive rate and other indicators of screening quality. As the learning curve depends on the number of mammograms read, these distinct strategies may bear different outcome in the long run. Implications and practical issues for low-volume programs are discussed.
Resumo:
[Abstract] Reading volume and mammography screening performance appear positively correlated. Performance was compared across organised Swiss screening programmes, which target relatively small populations. Except for accreditation of 2nd readers radiologists (restrictive vs non-restrictive strategy), Swiss programmes have similar screening regimen/procedures and duration, which maximises comparability. Variation in performance was explored in order to improve mammography practice and optimise screening performance. Indicators of quality and effectiveness were evaluated for about 200,000 screens performed over 4 screening rounds in the 3 longest-standing Swiss cantonal programmes (of Vaud, Geneva and Valais). Interval cancers were identified by linkage with cancer registries records. Most European standards of performance were met with a favourable cancer stage shift. Several performance indicators showed substantial variation across programmes. In subsequent rounds, compared with programmes (Vaud and Geneva) which accredited few 2nd readers to increase their individual reading volume, proportions of in situ lesions and of small cancers (? 1cm) were one third lower and halved, respectively, and the proportion of advanced lesions (stage II+) nearly 50% higher in the programme without a restrictive selection strategy. Discrepancy in second-year proportional incidence of interval cancers appears to be multicausal. Differences in performance could partly be explained by a selective strategy for 2nd readers and a prior experience in service screening, but not by the levels of opportunistic screening and programme attendance. This study provides clues for enhancing mammography screening performance in low-volume Swiss programmes.
Resumo:
BACKGROUND: Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. METHODS: PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. RESULTS: Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. CONCLUSIONS: No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks. These findings emphasize the need to improve algorithms for assisted ventilation modes to better deal with situations of high airway resistance, low pulmonary compliance, and the presence of leaks.
Resumo:
INTRODUCTION. Patient-ventilator asynchrony is a frequent issue in non invasivemechanical ventilation (NIV) and leaks at the patient-mask interface play a major role in itspathogenesis. NIV algorithms alleviate the deleterious impact of leaks and improve patient-ventilator interaction. Neurally adusted ventilatory assist (NAVA), a neurally triggered modethat avoids interferences between leaks and the usual pneumatic trigger, could further improvepatient-ventilator interaction in NIV patients.OBJECTIVES. To evaluate the feasibility ofNAVAin patients receiving a prophylactic postextubationNIV and to compare the respective impact ofPSVandNAVAwith and withoutNIValgorithm on patient-ventilator interaction.METHODS. Prospective study conducted in 16 beds adult critical care unit (ICU) in a tertiaryuniversity hospital. Over a 2 months period, were included 17 adult medical ICU patientsextubated for less than 2 h and in whom a prophylactic post-extubation NIV was indicated.Patients were randomly mechanically ventilated for 10 min with: PSV without NIV algorithm(PSV-NIV-), PSV with NIV algorithm (PSV-NIV+),NAVAwithout NIV algorithm (NAVANIV-)and NAVA with NIV algorithm (NAVA-NIV+). Breathing pattern descriptors, diaphragmelectrical activity, leaks volume, inspiratory trigger delay (Tdinsp), inspiratory time inexcess (Tiexcess) and the five main asynchronies were quantified. Asynchrony index (AI) andasynchrony index influenced by leaks (AIleaks) were computed.RESULTS. Peak inspiratory pressure and diaphragm electrical activity were similar in thefour conditions. With both PSV and NAVA, NIV algorithm significantly reduced the level ofleak (p\0.01). Tdinsp was not affected by NIV algorithm but was shorter in NAVA than inPSV (p\0.01). Tiexcess was shorter in NAVA and PSV-NIV+ than in PSV-NIV- (p\0.05).The prevalence of double triggering was significantly lower in PSV-NIV+ than in NAVANIV+.As compared to PSV,NAVAsignificantly reduced the prevalence of premature cyclingand late cycling while NIV algorithm did not influenced premature cycling. AI was not affectedby NIV algorithm but was significantly lower in NAVA than in PSV (p\0.05). AIleaks wasquasi null with NAVA and significantly lower than in PSV (p\0.05).CONCLUSIONS. NAVA is feasible in patients receiving a post-extubation prophylacticNIV. NAVA and NIV improve patient-ventilator synchrony in different manners. NAVANIV+offers the best patient-ventilator interaction. Clinical studies are required to assess thepotential clinical benefit of NAVA in patients receiving NIV.
Resumo:
OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.
Resumo:
OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.