158 resultados para Joint Angle
em Université de Lausanne, Switzerland
Resumo:
Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.
Resumo:
A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.
Resumo:
Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.
Resumo:
We aimed to analyze the changes in isokinetic internal (IR) and external (ER) rotator muscles fatigue (a) in patients with non-operated recurrent anterior instability, and (b) before and after shoulder surgical stabilization with the Bristow-Latarjet procedure. Thirty-seven patients with non-operated unilateral recurrent anterior post-traumatic instability (NG) were compared with 12 healthy subjects [control group (CG)]. Twenty patients with operated recurrent anterior instability group (OG) underwent isokinetic evaluation before and 3, 6, and 21 months after Bristow-Latarjet surgery. IR and ER muscles strength was evaluated with Con-Trex® dynamometer, with subjects seated and at a 45° shoulder abduction angle in scapular plane. IR and ER muscle fatigue was determined after 10 concentric repetitions at 180° · s(-1) through the fatigue index, the percent decrease in performance (DP), and the slope of peak torque decrease. There were no differences in rotator muscles fatigue between NG and CG. In OG, 3 months post-surgery, IR DP of operated shoulder was significantly (P < 0.001) higher than presurgery and 6 and 21 months post-surgery. Rotator muscles fatigability was not associated with recurrent anterior instability. After surgical stabilization, there was a significantly higher IR fatigability in the operated shoulder 3 months post-surgery, followed by recovery evidenced 6 months post-surgery and long-term maintenance over 21 months.
Resumo:
The joint angles of multi-segment foot models have been primarily described using two mathematical methods: the joint coordinate system and the attitude vector. This study aimed to determine whether the angles obtained through these two descriptors are comparable, and whether these descriptors have similar sensitivity to experimental errors. Six subjects walked eight times on an instrumented walkway while the joint angles among shank, hindfoot, medial forefoot, and lateral forefoot were measured. The angles obtained using both descriptors and their sensitivity to experimental errors were compared. There was no overall significant difference between the ranges of motion obtained using both descriptors. However, median differences of more than 6° were noticed for the medial-lateral forefoot joint. For all joints and rotation planes, both descriptors provided highly similar angle patterns (median correlation coefficient: R>0.90), except for the medial-lateral forefoot angle in the transverse plane (median R=0.77). The joint coordinate system was significantly more sensitive to anatomical landmarks misplacement errors. However, the absolute differences of sensitivity were small relative to the joints ranges of motion. In conclusion, the angles obtained using these two descriptors were not identical, but were similar for at least the shank-hindfoot and hindfoot-medial forefoot joints. Therefore, the angle comparison across descriptors is possible for these two joints. Comparison should be done more carefully for the medial-lateral forefoot joint. Moreover, despite different sensitivities to experimental errors, the effects of the experimental errors on the angles were small for both descriptors suggesting that both descriptors can be considered for multi-segment foot models.
The joint influence of gender and amount of smoking on weight gain one year after smoking cessation.
Resumo:
Weight gain is often associated with smoking cessation and may discourage smokers from quitting. This study estimated the weight gained one year after smoking cessation and examined the risk factors associated with weight gain in order to identify socio-demographic groups at higher risk of increased weight after quitting. We analyzed data from 750 adults in two randomized controlled studies that included smokers motivated to quit and found a gradient in weight gain according to the actual duration of abstinence during follow-up. Subjects who were abstinent for at least 40 weeks gained 4.6 kg (SD = 3.8) on average, compared to 1.2 kg (SD = 2.6) for those who were abstinent less than 20 weeks during the 1-year follow-up. Considering the duration of abstinence as an exposure variable, we found an age effect and a significant interaction between sex and the amount of smoking before quitting: younger subjects gained more weight than older subjects; among light smokers, men gained more weight on average than women one year after quitting, while the opposite was observed among heavy smokers. Young women smoking heavily at baseline had the highest risk of weight gain after quitting.
Resumo:
We used whole-exome sequencing to study three individuals with a distinct condition characterized by short stature, chondrodysplasia with brachydactyly, congenital joint dislocations, cleft palate, and facial dysmorphism. Affected individuals carried homozygous missense mutations in IMPAD1, the gene coding for gPAPP, a Golgi-resident nucleotide phosphatase that hydrolyzes phosphoadenosine phosphate (PAP), the byproduct of sulfotransferase reactions, to AMP. The mutations affected residues in or adjacent to the phosphatase active site and are predicted to impair enzyme activity. A fourth unrelated patient was subsequently found to be homozygous for a premature termination codon in IMPAD1. Impad1 inactivation in mice has previously been shown to produce chondrodysplasia with abnormal joint formation and impaired proteoglycan sulfation. The human chondrodysplasia associated with gPAPP deficiency joins a growing number of skeletoarticular conditions associated with defective synthesis of sulfated proteoglycans, highlighting the importance of proteoglycans in the development of skeletal elements and joints.
Resumo:
The prevalence of clonal complex (CC) 398 methicillin-susceptible Staphylococcus aureus (MSSA) was unexpectedly high among bone and joint infections (BJIs) and nasal-colonizing isolates in France, with surprising geographical heterogeneity. With none of the major, most-known staphylococcal virulence genes, MSSA CC398 BJI was associated with lower biological inflammatory syndrome and lower treatment failure rates.
Resumo:
A mycotic pseudoaneurysm of the popliteal artery is usually a consequence of septic embolization and often a result of bacterial endocarditis. Conventional treatment is surgical and avoids the placement of foreign material in infected sites. Here we report our treatment of a 59-year-old man who presented with a rupture of a mycotic pseudoaneurysm of the popliteal artery due to septic embolism from sternoclavicular infectious arthritis. Radiological investigations are included. This is the first documented case of septic arthritis complicated by a rupture of a mycotic popliteal false aneurysm and treated using an endovascular procedure. Combining endovascular stent grafts with evacuation of the joint abscess and antibiotic therapy can offer a safe alternative for frail and unstable patients.
Resumo:
PURPOSE: To assess the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography of the wrist with regard to joint space width and amount of contrast material between the opposing cartilage surfaces. MATERIALS AND METHODS: Fifteen consecutive patients (12 male, mean age 38.1 years) were included in this Institutional Review Board-approved prospective study. Three-compartment wrist MR arthrographies were performed between October and December 2009 on a 3 T unit using a fat-suppressed T1-weighted isotropic high-resolution volumetric interpolated breathhold examination (VIBE) sequence in the coronal plane, with and without axial traction (3 kg). Two radiologists measured radiocarpal (radioscaphoid, radiolunate) and midcarpal (lunocapitate, hamatolunate) joint space widths, with and without traction, and assessed the amount of contrast material between the opposing cartilage surfaces using a three-point scale: 0 = absence, 1 = partial, 2 = complete. RESULTS: With traction, joint space width increased significantly at the radioscaphoid (Delta = 0.78 mm, P < 0.01), radiolunate (Delta = 0.18 mm, P < 0.01), and lunocapitate (Delta = 0.45 mm, P < 0.01) spaces, and both observers detected significantly more contrast material between the cartilage surfaces. At the hamatolunate space, the differences in joint space width (Delta = 0.14 mm, P = 0.54) and amount of contrast material were not significant. CONCLUSION: Direct wrist MR arthrography with axial traction of 3 kg increases joint space width at the radiocarpal and lunocapitate spaces, and prompts better coverage of the articular cartilage by the contrast material. J. Magn. Reson. Imaging 2011;. (c) 2011 Wiley-Liss, Inc.
Resumo:
BACKGROUND: In addition to prosthetic rehabilitation, maxillary defects can also be surgically reconstructed. Soft-tissue reconstruction employs a radial forearm or latissimus dorsi muscle flap, while bony reconstruction can be achieved using a fibula, iliac crest, or scapular flap. Reconstruction using a scapular flap is further divided into two subgroups: the traditional scapular flap with the circumflex scapular artery as the donor vessel and the scapular angle flap with the angular artery originating from the thoracodorsal artery as the donor vessel. MATERIALS AND METHODS: We report on four patients who underwent successful reconstruction with a free scapular angle flap between 2009 and 2011, following maxillary resection due to malignancy. RESULTS: Vertical positioning of the scapular angle flap enables reconstruction of the facial contour, whereas its horizontal alignment and microvascular anastomosis makes a bony reconstruction of the hard palate possible. CONCLUSIONS: The versatility, low rate of donor site morbidity and shape of the scapular angle flap--which resembles that of the hard palate--render it ideal for plastic reconstruction. The suitability of bone quality for dental rehabilitation with implants is a topic of controversial discussion. The scapular angle flap represents an alternative to obturator prosthesis for the reconstruction of maxillary defects ≥ grade I according to Okay et al.