25 resultados para Jet physics
em Université de Lausanne, Switzerland
Resumo:
OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.
Resumo:
KNOTS are usually categorized in terms of topological properties that are invariant under changes in a knot's spatial configuration(1-4). Here we approach knot identification from a different angle, by considering the properties of particular geometrical forms which we define as 'ideal'. For a knot with a given topology and assembled from a tube of uniform diameter, the ideal form is the geometrical configuration having the highest ratio of volume to surface area. Practically, this is equivalent to determining the shortest piece of tube that can be closed to form the knot. Because the notion of an ideal form is independent of absolute spatial scale, the length-to-diameter ratio of a tube providing an ideal representation is constant, irrespective of the tube's actual dimensions. We report the results of computer simulations which show that these ideal representations of knots have surprisingly simple geometrical properties. In particular, there is a simple linear relationship between the length-to-diameter ratio and the crossing number-the number of intersections in a two-dimensional projection of the knot averaged over all directions. We have also found that the average shape of knotted polymeric chains in thermal equilibrium is closely related to the ideal representation of the corresponding knot type. Our observations provide a link between ideal geometrical objects and the behaviour of seemingly disordered systems, and allow the prediction of properties of knotted polymers such as their electrophoretic mobility(5).
Resumo:
La trachée et les bronches proximales sont de fins conduits subtils, ingénieusement structurés par une partie cartilagineuse antérieure résistante aux variations de pression et une partie membraneuse postérieure souple. Par leurs faibles volumes (espace mort) ils délivrent un grand pourcentage de l'air inspiré aux voies distales, puis au parenchyme pulmonaire, permettant les échanges de gaz. Cette belle harmonie respiratoire peut être rapidement mise à mal dès qu'un processus atteint ces voies respiratoires proximales, soit en les comprimant, processus sténosant, soit en affaiblissant leur structure, trachéo-bronchomalacie, soit en ouvrant leur paroi sur les structures médiastinales, fistule trachéo/broncho-médiastinales, pleurales ou autres. Le pronostic vital est alors rapidement engagé au vu de l'absolue nécessité du bon fonctionnement de ces fins conduits, une petite diminution du calibre de leurs fines lumières provoquant une baisse importante de leurs surfaces. Dans ces situations à haut potentiel de complication majeure les interventions endoscopiques pour restaurer l'intégrité de ces conduits sont alors fort risquées, et il est primordial de pouvoir les effectuer dans un cadre sécurisé au maximum. La réalisation de ces gestes par la technique décrite dans notre article « Use of combined suspension laryngoscopy, flexible bronchoscopy and high frequency jet ventilation forY-shaped airway stents delivery" permet la sécurité nécessaire à ces situations instable, en effet -la laryngoscopie en suspension expose les voies proximales en offrant un accès le plus large possible à l'arbre trachéobronchique ce qui permet l insertion de multiples instruments parfois volumineux, -la Jet ventilation assure une oxygénation et une ventilation adéquate par un fin cathéter placé soit dans le poumon sain, soit en distalité de la lésion -la bronchoscopie souple, passant au travers d'endroits exigus et courbes permet le déploiement sous vision direct, au millimètre près, de divers dispositifs. Cette association remplace avantageusement la technique traditionnelle qui insère les stents à l'aveugle, et en apnée, ce qui représente de haut risque de mauvais positionnement des stents avec des conséquences immédiates sur l'oxygénation et la ventilation souvent déjà bien altérées. Perspective et conclusion : cette technique est utile pour l'insertion des stents en Y, centraux, comme décrit dans notre article, et les indications peuvent être étendues aux stents distaux pour lesquels l'accès n'est parfois pas aisé avec le bronchoscope rigide, et pour d'autres interventions endoscopiques, laser, cryothérapie, radiofréquence ou l'insertion de nouveaux dispositifs.
Resumo:
Purpose: To evaluate the use of high frequency jet ventilation (HFJV) in patients undergoing percutanous thermal ablation procedures.Materials: From may to september 2011 patients with lung, liver or kidney tumors suitable for percutanous thermal ablation were prospectively enrolled to be treated under general anesthesia using HFJV instead of conventional positive pressure ventilation (PPV). Our primary endpoint was feasability of HFJV during percutanous ablation, our secondary endpoints were assessment of breathing related movements by image fusion (CT/US), precision and ease of needle placement by number of CT aquisition/needle reposition and procedure related complications.Results: Twenty-nine patients (21 males, 8 females mean age 66.2 years) with 30 liver tumors, 1 kidney tumors and 6 lung tumors were included. Tumor ablation was performed by radiofrequency (RFA) in 26 cases, microwaves ( MWA) in 2 and cryoablation (CRA) in 1. The ablation procedure could be completed under HFJV in 22 patients. In 2 patients HFVJ had to be stopped in favor of PPV because the tumor was better seen under PPV. HFJV was not performed in 5. Breathing related movements of the target lesion in the cranio-caudal direction as estimated by image fusion were always inferior to 5mm compared to 20mm when patients are under PPV. Needle placement was straightforward under CT as well as US. No patient needed needle repositionning before ablation. We did not observe any HFJV related complications.Conclusions: HFJV significantly reduces breathing movements of target lesion during percutaneous ablation procedures. It does not seem to cause any particular complication. However in some cases such as tumors located at the base of the lungs or in the dome of the liver, the target may be best seen under PPV.
Resumo:
The concept of ideal geometric configurations was recently applied to the classification and characterization of various knots. Different knots in their ideal form (i.e., the one requiring the shortest length of a constant-diameter tube to form a given knot) were shown to have an overall compactness proportional to the time-averaged compactness of thermally agitated knotted polymers forming corresponding knots. This was useful for predicting the relative speed of electrophoretic migration of different DNA knots. Here we characterize the ideal geometric configurations of catenanes (called links by mathematicians), i.e., closed curves in space that are topologically linked to each other. We demonstrate that the ideal configurations of different catenanes show interrelations very similar to those observed in the ideal configurations of knots. By analyzing literature data on electrophoretic separations of the torus-type of DNA catenanes with increasing complexity, we observed that their electrophoretic migration is roughly proportional to the overall compactness of ideal representations of the corresponding catenanes. This correlation does not apply, however, to electrophoretic migration of certain replication intermediates, believed up to now to represent the simplest torus-type catenanes. We propose, therefore, that freshly replicated circular DNA molecules, in addition to forming regular catenanes, may also form hemicatenanes.
Resumo:
Synchrotron radiation X-ray tomographic microscopy is a nondestructive method providing ultra-high-resolution 3D digital images of rock microstructures. We describe this method and, to demonstrate its wide applicability, we present 3D images of very different rock types: Berea sandstone, Fontainebleau sandstone, dolomite, calcitic dolomite, and three-phase magmatic glasses. For some samples, full and partial saturation scenarios are considered using oil, water, and air. The rock images precisely reveal the 3D rock microstructure, the pore space morphology, and the interfaces between fluids saturating the same pore. We provide the raw image data sets as online supplementary material, along with laboratory data describing the rock properties. By making these data sets available to other research groups, we aim to stimulate work based on digital rock images of high quality and high resolution. We also discuss and suggest possible applications and research directions that can be pursued on the basis of our data.
Resumo:
Particle physics studies highly complex processes which cannot be directly observed. Scientific realism claims that we are nevertheless warranted in believing that these processes really occur and that the objects involved in them really exist. This dissertation defends a version of scientific realism, called causal realism, in the context of particle physics. I start by introducing the central theses and arguments in the recent philosophical debate on scientific realism (chapter 1), with a special focus on an important presupposition of the debate, namely common sense realism. Chapter 2 then discusses entity realism, which introduces a crucial element into the debate by emphasizing the importance of experiments in defending scientific realism. Most of the chapter is concerned with Ian Hacking's position, but I also argue that Nancy Cartwright's version of entity realism is ultimately preferable as a basis for further development. In chapter 3,1 take a step back and consider the question whether the realism debate is worth pursuing at all. Arthur Fine has given a negative answer to that question, proposing his natural ontologica! attitude as an alternative to both realism and antirealism. I argue that the debate (in particular the realist side of it) is in fact less vicious than Fine presents it. The second part of my work (chapters 4-6) develops, illustrates and defends causal realism. The key idea is that inference to the best explanation is reliable in some cases, but not in others. Chapter 4 characterizes the difference between these two kinds of cases in terms of three criteria which distinguish causal from theoretical warrant. In order to flesh out this distinction, chapter 5 then applies it to a concrete case from the history of particle physics, the discovery of the neutrino. This case study shows that the distinction between causal and theoretical warrant is crucial for understanding what it means to "directly detect" a new particle. But the distinction is also an effective tool against what I take to be the presently most powerful objection to scientific realism: Kyle Stanford's argument from unconceived alternatives. I respond to this argument in chapter 6, and I illustrate my response with a discussion of Jean Perrin's experimental work concerning the atomic hypothesis. In the final part of the dissertation, I turn to the specific challenges posed to realism by quantum theories. One of these challenges comes from the experimental violations of Bell's inequalities, which indicate a failure of locality in the quantum domain. I show in chapter 7 how causal realism can further our understanding of quantum non-locality by taking account of some recent experimental results. Another challenge to realism in quantum mechanics comes from delayed-choice experiments, which seem to imply that certain aspects of what happens in an experiment can be influenced by later choices of the experimenter. Chapter 8 analyzes these experiments and argues that they do not warrant the antirealist conclusions which some commentators draw from them. It pays particular attention to the case of delayed-choice entanglement swapping and the corresponding question whether entanglement is a real physical relation. In chapter 9,1 finally address relativistic quantum theories. It is often claimed that these theories are incompatible with a particle ontology, and this calls into question causal realism's commitment to localizable and countable entities. I defend the commitments of causal realism against these objections, and I conclude with some remarks connecting the interpretation of quantum field theory to more general metaphysical issues confronting causal realism.
Resumo:
PURPOSE: To report feasibility and potential benefits of high-frequency jet ventilation (HFJV) in tumor ablations techniques in liver, kidney, and lung lesions. METHODS: This prospective study included 51 patients (14 women, mean age 66 years) bearing 66 tumors (56 hepatic, 5 pulmonary, 5 renal tumors) with a median size of 16 ± 8.7 mm, referred for tumor ablation in an intention-to-treat fashion before preoperative anesthesiology visit. Cancellation and complications of HFJV were prospectively recorded. Anesthesia and procedure duration, as well as mean CO2 capnea, were recorded. When computed tomography guidance was used, 3D spacial coordinates of an anatomical target <2 mm in diameter on 8 slabs of 4 slices of 3.75-mm slice thickness were registered. RESULTS: HFJV was used in 41 of 51 patients. Of the ten patients who were not candidate for HFJV, two patients had contraindication to HFJV (severe COPD), three had lesions invisible under HFJV requiring deep inspiration apnea for tumor targeting, and five patients could not have HFJV because of unavailability of a trained anesthetic team. No specific complication or hypercapnia related to HFJV were observed despite a mean anesthetic duration of 2 h and ventilation performed in procubitus (n = 4) or lateral decubitus (n = 6). Measured internal target movement was 0.3 mm in x- and y-axis and below the slice thickness of 3.75 mm in the z-axis in 11 patients. CONCLUSIONS: HFJV is feasible in 80 % of patients allowing for near immobility of internal organs during liver, kidney, and lung tumor ablation.
Resumo:
Airway stenting is a common endoscopic procedure that is used to treat a variety of central airway lesions. Obstructions or fistulas involving the carina or nearby tracheobronchial structures require the use of specially designed stents, commonly referred to as Y-stents. Conventional methods of endobronchial Y-stent delivery are all characterized by a blind and apneic period during the procedure that carries the risk of stent misplacement or ventilation/oxygenation problems or both. Using combined suspension laryngoscopy, flexible bronchoscopy, and jet ventilation, we describe a technique that makes challenging bronchoscopic interventions--such as self-expandable Y-shaped airway stent delivery--easy, precise, and safe.
Resumo:
BACKGROUND AND PURPOSE: Intensity-modulated radiotherapy (IMRT) credentialing for a EORTC study was performed using an anthropomorphic head phantom from the Radiological Physics Center (RPC; RPCPH). Institutions were retrospectively requested to irradiate their institutional phantom (INSTPH) using the same treatment plan in the framework of a Virtual Phantom Project (VPP) for IMRT credentialing. MATERIALS AND METHODS: CT data set of the institutional phantom and measured 2D dose matrices were requested from centers and sent to a dedicated secure EORTC uploader. Data from the RPCPH and INSTPH were thereafter centrally analyzed and inter-compared by the QA team using commercially available software (RIT; ver.5.2; Colorado Springs, USA). RESULTS: Eighteen institutions participated to the VPP. The measurements of 6 (33%) institutions could not be analyzed centrally. All other centers passed both the VPP and the RPC ±7%/4 mm credentialing criteria. At the 5%/5 mm gamma criteria (90% of pixels passing), 11(92%) as compared to 12 (100%) centers pass the credentialing process with RPCPH and INSTPH (p = 0.29), respectively. The corresponding pass rate for the 3%/3 mm gamma criteria (90% of pixels passing) was 2 (17%) and 9 (75%; p = 0.01), respectively. CONCLUSIONS: IMRT dosimetry gamma evaluations in a single plane for a H&N prospective trial using the INSTPH measurements showed agreement at the gamma index criteria of ±5%/5 mm (90% of pixels passing) for a small number of VPP measurements. Using more stringent, criteria, the RPCPH and INSTPH comparison showed disagreement. More data is warranted and urgently required within the framework of prospective studies.