11 resultados para Jämsä, Timo
em Université de Lausanne, Switzerland
Resumo:
Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. The different gases are separated by specific columns but, if hydrogen (H2 ) is present in the sample, its detection can be performed by a thermal conductivity detector or a helium ionization detector. Indeed, coupled to GC, no other detector can perform this detection except the expensive atomic emission detector. Based on the detection and analysis of H2 isotopes by low-pressure chemical ionization mass spectrometry (MS), a new method for H2 detection by GC coupled to MS with an electron ionization ion source and a quadrupole analyser is presented. The presence of H2 in a gaseous mixture could easily be put in evidence by the monitoring of the molecular ion of the protonated carrier gas. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
Imaging mass spectrometry (IMS) is useful for visualizing the localization of phospholipids on biological tissue surfaces creating great opportunities for IMS in lipidomic investigations. With advancements in IMS of lipids, there is a demand for large-scale tissue studies necessitating stable, efficient and well-defined sample handling procedures. Our work within this article shows the effects of different storage conditions on the phospholipid composition of sectioned tissues from mouse organs. We have taken serial sections from mouse brain, kidney and liver thaw mounted unto ITO-coated glass slides and stored them under various conditions later analyzing them at fixed time points. A global decrease in phospholipid signal intensity is shown to occur and to be a function of time and temperature. Contrary to the global decrease, oxidized phospholipid and lysophospholipid species are found to increase within 2 h and 24 h, respectively, when mounted sections are kept at ambient room conditions. Imaging experiments reveal that degradation products increase globally across the tissue. Degradation is shown to be inhibited by cold temperatures, with sample integrity maintained up to a week after storage in −80 °C freezer under N2 atmosphere. Overall, the results demonstrate a timeline of the effects of lipid degradation specific to sectioned tissues and provide several lipid species which can serve as markers of degradation. Importantly, the timeline demonstrates oxidative sample degradation begins appearing within the normal timescale of IMS sample preparation of lipids (i.e. 1-2 h) and that long-term degradation is global. Taken together, these results strengthen the notion that standardized procedures are required for phospholipid IMS of large sample sets, or in studies where many serial sections are prepared together but analyzed over time such as in 3-D IMS reconstruction experiments.
Resumo:
Imaging mass spectrometry (IMS) is an emergent and innovative approach for measuring the composition, abundance and regioselectivity of molecules within an investigated area of fixed dimension. Although providing unprecedented molecular information compared with conventional MS techniques, enhancement of protein signature by IMS is still necessary and challenging. This paper demonstrates the combination of conventional organic washes with an optimized aqueous-based buffer for tissue section preparation before matrix-assisted laser desorption/ionization (MALDI) IMS of proteins. Based on a 500 mM ammonium formate in water-acetonitrile (9:1; v/v, 0.1% trifluororacetic acid, 0.1% Triton) solution, this buffer wash has shown to significantly enhance protein signature by profiling and IMS (~fourfold) when used after organic washes (70% EtOH followed by 90% EtOH), improving the quality and number of ion images obtained from mouse kidney and a 14-day mouse fetus whole-body tissue sections, while maintaining a similar reproducibility with conventional tissue rinsing. Even if some protein losses were observed, the data mining has demonstrated that it was primarily low abundant signals and that the number of new peaks found is greater with the described procedure. The proposed buffer has thus demonstrated to be of high efficiency for tissue section preparation providing novel and complementary information for direct on-tissue MALDI analysis compared with solely conventional organic rinsing.
Resumo:
OBJECTIVES: There is a continuing need to monitor and evaluate the impact of organized screening programmes on cancer incidence and mortality. We report results from a programme assessment conducted within the International Cancer Screening Network (ICSN) to understand the characteristics of cervical screening programmes within countries that have established population-based breast cancer screening programmes. METHODS: In 2007-2008, we asked 26 ICSN country representatives to complete a web-based survey that included questions on breast and cervical cancer screening programmes. We summarized information from 16 countries with both types of organized programmes. RESULTS: In 63% of these countries, the organization of the cervical cancer screening programme was similar to that of the breast cancer screening programme in the same country. There were differences in programme characteristics, including year established (1962-2003 cervical; 1986-2002 breast) and ages covered (15-70+ cervical; 40-75+ breast). Adoption of new screening technologies was evident (44% liquid-based Pap tests; 13% human papillomavirus (HPV)-triage tests cervical; 56% digital mammography breast). There was wide variation in participation rates for both programme types (<4-80% cervical; 12-88% breast), and participation rates tended to be higher for cervical (70-80%) than for breast (60-70%) cancer screening programmes. Eleven ICSN member countries had approved the HPV vaccine and five more were considering its use in their organized programmes. CONCLUSION: Overall, there were similarities and differences in the organization of breast and cervical cancer screening programmes among ICSN countries. This assessment can assist established and new screening programmes in understanding the organization and structure of cancer screening programmes.
Resumo:
The EUROCAT website www.eurocat-network.eu publishes prenatal detection rates for major congenital anomalies using data from European population-based congenital anomaly registers, covering 28% of the EU population as well as non-EU countries. Data are updated annually. This information can be useful for comparative purposes to clinicians and public health service managers involved in the antenatal care of pregnant women as well as those interested in perinatal epidemiology.
Resumo:
BACKGROUND: Multiple epiphyseal dysplasia (MED) is one of the more common generalised skeletal dysplasias. Due to its clinical heterogeneity diagnosis may be difficult. Mutations of at least six separate genes can cause MED. Joint deformities, joint pain and gait disorders are common symptoms. CASE PRESENTATION: We report on a 27-year-old male patient suffering from clinical symptoms of autosomal recessive MED with habitual dislocation of a multilayered patella on both sides, on the surgical treatment and on short-term clinical outcome. Clinical findings were: bilateral hip and knee pain, instability of femorotibial and patellofemoral joints with habitual patella dislocation on both sides, contractures of hip, elbow and second metacarpophalangeal joints. Main radiographic findings were: bilateral dislocated multilayered patella, dysplastic medial tibial plateaus, deformity of both femoral heads and osteoarthritis of the hip joints, and deformity of both radial heads. In the molecular genetic analysis, the DTDST mutation g.1984T > A (p.C653S) was found at the homozygote state. Carrier status was confirmed in the DNA of the patient's parents. The mutation could be considered to be the reason for the patient's disease. Surgical treatment of habitual patella dislocation with medialisation of the tibial tuberosity led to an excellent clinical outcome. CONCLUSIONS: The knowledge of different phenotypes of skeletal dysplasias helps to select genes for genetic analysis. Compared to other DTDST mutations, this is a rather mild phenotype. Molecular diagnosis is important for genetic counselling and for an accurate prognosis. Even in case of a multilayered patella in MED, habitual patella dislocation could be managed successfully by medialisation of the tibial tuberosity.
Resumo:
Because of the large variability in the pharmacokinetics of anti-HIV drugs, therapeutic drug monitoring in patients may contribute to optimize the overall efficacy and safety of antiretroviral therapy. An LC-MS/MS method for the simultaneous assay in plasma of the novel antiretroviral agents rilpivirine (RPV) and elvitegravir (EVG) has been developed to that endeavor. Plasma samples (100 μL) extraction is performed by protein precipitation with acetonitrile, and the supernatant is subsequently diluted 1:1 with 20-mM ammonium acetate/MeOH 50:50. After reverse-phase chromatography, quantification of RPV and EVG, using matrix-matched calibration samples, is performed by electrospray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The stable isotopic-labeled compounds RPV-(13) C6 and EVG-D6 were used as internal standards. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<6.4%), as well as EVG and RPV short and long-term stability in plasma. Calibration curves were validated over the clinically relevant concentrations ranging from 5 to 2500 ng/ml for RPV and from 50 to 5000 ng/ml for EVG. The method is precise (inter-day CV%: 3-6.3%) and accurate (3.8-7.2%). Plasma samples were found to be stable (<15%) in all considered conditions (RT/48 h, +4°C/48 h, -20°C/3 months and 60°C/1 h). Selected metabolite profiles analysis in patients' samples revealed the presence of EVG glucuronide, that was well separated from parent EVG, allowing to exclude potential interferences through the in-source dissociation of glucuronide to parent drug. This new, rapid and robust LCMS/MS assay for the simultaneous quantification of plasma concentrations of these two major new anti-HIV drugs EVG and RPV offers an efficient analytical tool for clinical pharmacokinetics studies and routine therapeutic drug monitoring service. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
OBJECTIVE: To compare interval breast cancer rates (ICR) between a biennial organized screening programme in Norway and annual opportunistic screening in North Carolina (NC) for different conceptualizations of interval cancer. SETTING: Two regions with different screening practices and performance. METHODS: 620,145 subsequent screens (1996-2002) performed in women aged 50-69 and 1280 interval cancers were analysed. Various definitions and quantification methods for interval cancers were compared. RESULTS: ICR for one year follow-up were lower in Norway compared with NC both when the rate was based on all screens (0.54 versus 1.29 per 1000 screens), negative final assessments (0.54 versus 1.29 per 1000 screens), and negative screening assessments (0.53 versus 1.28 per 1000 screens). The rate of ductal carcinoma in situ was significantly lower in Norway than in NC for cases diagnosed in both the first and second year after screening. The distributions of histopathological tumour size and lymph node involvement in invasive cases did not differ between the two regions for interval cancers diagnosed during the first year after screening. In contrast, in the second year after screening, tumour characteristics remained stable in Norway but became prognostically more favorable in NC. CONCLUSION: Even when applying a common set of definitions of interval cancer, the ICR was lower in Norway than in NC. Different definitions of interval cancer did not influence the ICR within Norway or NC. Organization of screening and screening performance might be major contributors to the differences in ICR between Norway and NC.