174 resultados para Intra-examiner reproducibility

em Université de Lausanne, Switzerland


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RATIONALE: The aim of the work was to develop and validate a method for the quantification of vitamin D metabolites in serum using ultra-high-pressure liquid chromatography coupled to mass spectrometry (LC/MS), and to validate a high-resolution mass spectrometry (LC/HRMS) approach against a tandem mass spectrometry (LC/MS/MS) approach using a large clinical sample set. METHODS: A fast, accurate and reliable method for the quantification of the vitamin D metabolites, 25-hydroxyvitamin D2 (25OH-D2) and 25-hydroxyvitamin D3 (25OH-D3), in human serum was developed and validated. The C3 epimer of 25OH-D3 (3-epi-25OH-D3) was also separated from 25OH-D3. The samples were rapidly prepared via a protein precipitation step followed by solid-phase extraction (SPE) using an HLB μelution plate. Quantification was performed using both LC/MS/MS and LC/HRMS systems. RESULTS: Recovery, matrix effect, inter- and intra-day reproducibility were assessed. Lower limits of quantification (LLOQs) were determined for both 25OH-D2 and 25OH-D3 for the LC/MS/MS approach (6.2 and 3.4 µg/L, respectively) and the LC/HRMS approach (2.1 and 1.7 µg/L, respectively). A Passing & Bablok fit was determined between both approaches for 25OH-D3 on 662 clinical samples (1.11 + 1.06x). It was also shown that results can be affected by the inclusion of the isomer 3-epi-25OH-D3. CONCLUSIONS: Quantification of the relevant vitamin D metabolites was successfully developed and validated here. It was shown that LC/HRMS is an accurate, powerful and easy to use approach for quantification within clinical laboratories. Finally, the results here suggest that it is important to separate 3-epi-25OH-D3 from 25OH-D3. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. PARTICIPANTS AND METHODS: Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. RESULTS: The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). CONCLUSIONS: Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectif: Alors qu'un antécédent d' AMS est couramment utilisé pour fournir des conseils et recommander une prophylaxie médicamenteuse pour les expositions ultérieures à la haute altitude, la reproductibilité intra-individuelle de l'AMS au cours d'expositions répétées n'a jamais été examinée dans une étude prospective contrôlée. Méthodes : Chez 27 enfants et 29 adultes non acclimatés, nous avons évalué la présence et la sévérité de l' AMS durant les 48 premières heures après une montée rapide à 3450m, et ceci en deux occasions distantes de 9 à 12 mois. Résultats: 18 adultes (62 %) et 6 enfants (22 %) ont souffert d'AMS durant la première exposition et 14 adultes (48 %) et 4 enfants (15 %) durant la seconde (P=O.Ol, adultes versus enfants). Mais surtout, la reproductibilité intra-individuelle de l'AMS était très différente (P < 0.001) entre les deux groupes; en effet, aucun des 6 enfants ayant souffert d'AMS au cours de la première exposition n'en n'a souffert au cours de la seconde mais 4 enfants sans AMS lors de la première exposition ont été touchés lors de la seconde exposition. Contrairement à cela, 14 des 18 adultes qui ont souffert de 1' AMS lors de la première exposition ont également présenté ce problème au cours de la seconde et aucun nouveau cas ne s'est développé dans ceux qui n'avaient pas souffert de cette affection lors de la première occasion. ConClusion : Si chez 1' adulte, un antécédent d' AMS a une bonne valeur prédictive d'un nouvel épisode durant les expositions futures dans des conditions similaires, il n'en est pas de même chez l'enfant chez lequel il n'a pas de valeur prédictive. Un antécédent d'AMS ne devrait donc pas inciter les praticiens à déconseiller la réexposition ou à prescrire une prophylaxie médicamenteuse chez l'enfant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Calibrated BOLD fMRI is a promising alternative to the classic BOLD contrast due to its reduced venous sensitivity and greater physiological specificity. The delayed adoption of this technique for cognitive studies may stem partly from a lack of information on the reproducibility of these measures in the context of cognitive tasks. In this study we have explored the applicability and reproducibility of a state-of-the-art calibrated BOLD technique using a complex functional task at 7 tesla. Reproducibility measures of BOLD, CBF, CMRO2 flow-metabolism coupling n and the calibration parameter M were compared and interpreted for three ROIs. We found an averaged intra-subject variation of CMRO2 of 8% across runs and 33% across days. BOLD (46% across runs, 36% across days), CBF (33% across runs, 46% across days) and M (41% across days) showed significantly higher intra-subject variability. Inter-subject variability was found to be high for all quantities, though CMRO2 was the most consistent across brain regions. The results of this study provide evidence that calibrated BOLD may be a viable alternative for longitudinal and cognitive MRI studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aerobic exercise training performed at the intensity eliciting maximal fat oxidation (Fatmax) has been shown to improve the metabolic profile of obese patients. However, limited information is available on the reproducibility of Fatmax and related physiological measures. The aim of this study was to assess the intra-individual variability of: a) Fatmax measurements determined using three different data analysis approaches and b) fat and carbohydrate oxidation rates at rest and at each stage of an individualized graded test. Fifteen healthy males [body mass index 23.1±0.6 kg/m2, maximal oxygen consumption ([Formula: see text]) 52.0±2.0 ml/kg/min] completed a maximal test and two identical submaximal incremental tests on ergocycle (30-min rest followed by 5-min stages with increments of 7.5% of the maximal power output). Fat and carbohydrate oxidation rates were determined using indirect calorimetry. Fatmax was determined with three approaches: the sine model (SIN), measured values (MV) and 3rd polynomial curve (P3). Intra-individual coefficients of variation (CVs) and limits of agreement were calculated. CV for Fatmax determined with SIN was 16.4% and tended to be lower than with P3 and MV (18.6% and 20.8%, respectively). Limits of agreement for Fatmax were -2±27% of [Formula: see text] with SIN, -4±32 with P3 and -4±28 with MV. CVs of oxygen uptake, carbon dioxide production and respiratory exchange rate were <10% at rest and <5% during exercise. Conversely, CVs of fat oxidation rates (20% at rest and 24-49% during exercise) and carbohydrate oxidation rates (33.5% at rest, 8.5-12.9% during exercise) were higher. The intra-individual variability of Fatmax and fat oxidation rates was high (CV>15%), regardless of the data analysis approach employed. Further research on the determinants of the variability of Fatmax and fat oxidation rates is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME : L'athérosclérose, pathologie inflammatoire artérielle chronique, est à l'origine de la plupart des maladies cardiovasculaires qui constituent l'une des premières causes de morbidité et mortalité en France. Les études observationnelles et expérimentales montrent que l'exercice physique prévient la mortalité cardiovasculaire. Cependant, les mécanismes précisant les bénéfices cliniques de l'exercice sur l'athérosclérose sont encore largement inconnus. Le but général de ce travail a donc été d'explorer, en utilisant un modèle expérimental d'athérosclérose, la souris hypercholestérolémique génétiquement dépourvue en apolipoprotéine E (apoE-/-), les mécanismes athéroprotecteurs de l'exercice. La dysfonction endothéliale, généralement associée aux facteurs de risque cardiovasculaire, serait l'une des étapes précoces majeures de l'athérogenèse. Elle est caractérisée par une diminution de la biodisponibilité en monoxyde d'azote (NO) avec la perte de ses propriétés vasculo-protectrices, ce qui favorise un climat pro-athérogène (stress oxydatif, adhésion et infiltration des cellules inflammatoires dans la paroi artérielle...) conduisant à la formation de la plaque athéromateuse. L'objectif de notre premier travail a donc été d'explorer les effets de l'exercice d'une part, sur le développement des plaques athéromateuses et d'autre part, sur la fonction endothéliale de la souris apoE-/-. Nos résultats montrent que l'exercice réduit significativement l'extension de l'athérosclérose et prévient la dysfonction endothéliale. L'explication pharmacologique montre que l'exercice stimule la fonction endothéliale via, notamment, une plus grande sensibilité des récepteurs endothéliaux muscariniques, ce qui active les événements signalétiques cellulaires récepteurs-dépendants à l'origine d'une bioactivité accrue de NO. Les complications cliniques graves de l'athérosclérose sont induites par la rupture de la plaque instable provoquant la formation d'un thrombus occlusif et l'ischémie du territoire tissulaire en aval. L'objectif de notre deuxième travail a été d'examiner l'effet de l'exercice sur la qualité/stabilité de la plaque. Nos résultats indiquent que l'exercice de longue durée stabilise la plaque en augmentant le nombre de cellules musculaires lisses et en diminuant le nombre de macrophages intra-plaques. Nos résultats montrent aussi que la phosphorylation de la eNOS (NO Synthase endothéliale) Akt-dépendante n'est pas le mécanisme moléculaire majeur à l'origine de ce bénéfice. Enfin, dans notre troisième travail, nous avons investigué l'effet de l'exercice sur le développement de la plaque vulnérable. Nos résultats montrent, chez un modèle murin de plaque instable (modèle d'hypertension rénovasculaire à rénine et angiotensine II élevés) que l'exercice prévient l'apparition de la plaque vulnérable indépendamment d'un effet hémodynamique. Ce bénéfice serait associé à une diminution de l'expression vasculaire des récepteurs AT1 de l'Angiotensine II. Nos résultats justifient l'importance de l'exercice comme outil préventif des maladies cardiovasculaires. ABSTRACT : Atherosclerosis, a chronic inflammatory disease, is one of the main causes of morbidity and mortality in France. Observational and experimental data indicate that regular physical exercise has a positive impact on cardiovascular mortality. However, the mechanisms by which exercise exerts clinical benefits on atherosclerosis are still unknown. The general aim of this work was to elucidate the anti-atherosclerotic effects of exercise, using a mouse model of atherosclerosis: the apolipoprotein E-deficient mice (apoE-/- mice). Endothelial dysfunction, generally associated with cardiovascular risk factors, has been recognized to be a major and early step in atherogenesis. Endothelial dysfunction is characterized by Nitric Oxide (NO) biodisponibility reduction with loss of NO-mediated vasculoprotective actions. This leads to vascular effects such as increased oxidative stress and increased adhesion of inflammatory cells into arterial wall thus playing a role in atherosclerotic plaque development. Therefore, one of the objective of our study was to explore the effects of exercise on atherosclerotic plaque extension and on endothelial function in apoE-/- mice. Results show that exercise significantly reduces plaque progression and prevents endothelial dysfunction. Pharmacological explanation indicates that exercise stimulates endothelial function by increasing muscarinic receptors sensitivity which in turn activates intracellular signalling receptor-dependent events leading to increased NO bioactivity. The clinical manifestations of atherosclerosis are the consequences of unstable plaque rupture with thrombus formation leading to tissue ischemia. The second aim of our work was to determine the effect of exercise on plaque stability. We demonstrate that long-term exercise stabilizes atherosclerotic plaques as shown by decreased macrophage and increased Smooth Muscle Cells plaque content. Our results also suggest that the Akt-dependent eNOS phosphorylation pathway is not the primary molecular mechanism mediating these beneficial effects. Finally, we assessed a putative beneficial effect of exercise on vulnerable plaque development. In a mouse model of Angiotensine II (Ang II)-mediated vulnerable atherosclerotic plaques, we provide fist evidence that exercise prevents atherosclerosis progression and plaque vulnerability. The beneficial effect of swimming was associated with decreased aortic Ang II AT1 receptor expression independently from any hemodynamic change. These findings suggest clinical benefit of exercise in terms of cardiovascular event protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Hypotension, a common intra-operative incident, bears an important potential for morbidity. It is most often manageable and sometimes preventable, which renders its study important. Therefore, we aimed at examining hospital variations in the occurrence of intra-operative hypotension and its predictors. As secondary endpoints, we determined to what extent hypotension relates to the risk of post-operative incidents and death. METHODS: We used the Anaesthesia Databank Switzerland, built on routinely and prospectively collected data on all anaesthesias in 21 hospitals. The three outcomes were assessed using multi-level logistic regression models. RESULTS: Among 147,573 anaesthesias, hypotension ranged from 0.6% to 5.2% in participating hospitals, and from 0.3% up to 12% in different surgical specialties. Most (73.4%) were minor single events. Age, ASA status, combined general and regional anaesthesia techniques, duration of surgery and hospitalization were significantly associated with hypotension. Although significantly associated, the emergency status of the surgery had a weaker effect. Hospitals' odds ratios for hypotension varied between 0.12 and 2.50 (P < or = 0.001), even after adjusting for patient and anaesthesia factors, and for type of surgery. At least one post-operative incident occurred in 9.7% of the procedures, including 0.03% deaths. Intra-operative hypotension was associated with a higher risk of post-operative incidents and death. CONCLUSION: Wide variations remain in the occurrence of hypotension among hospitals after adjustment for risk factors. Although differential reporting from hospitals may exist, variations in anaesthesia techniques and blood pressure maintenance may also have contributed. Intra-operative hypotension is associated with morbidities and sometimes death, and constant vigilance must thus be advocated.