25 resultados para Intervertebral Disk Displacement
em Université de Lausanne, Switzerland
Resumo:
STUDY DESIGN: Double-blind, placebo-controlled randomized clinical trial. OBJECTIVE: To assess the efficacy of 1 preoperative 1.5 g dose of cefuroxime in preventing surgical site infection after surgery for herniated disc. SUMMARY OF BACKGROUND DATA: Antibiotic prophylaxis was only tested in nonconclusive trials in this setting. METHODS: The study was conducted in 2 university hospitals in Switzerland. Patients were assessed for occurrence of surgical site infection (defined by the criteria of the Centers for Diseases Control and Prevention), other infections, or adverse events up to 6 months after surgery. Outcome measures were compared in a univariate, per-protocol analysis. RESULTS: Baseline characteristics were similar in patients allocated to cefuroxime (n = 613) or placebo (n = 624). Eight (1.3%) patients in the cefuroxime group and 18 patients (2.8%) in the placebo group developed a surgical site infection (P = 0.073). A diagnosis of spondylodiscitis or epidural abscess was made in 9 patients in the placebo group, but none in the cefuroxime group (P < 0.01), which corresponded to a number necessary to treat of 69 patients to prevent one of these infections. There were no significant adverse events attributed to either cefuroxime or placebo. CONCLUSION: A single, preoperative dose of cefuroxime significantly reduces the risk of organ-space infection, most notably spondylodiscitis, after surgery for herniated disc.
Resumo:
En Suisse, la variabilité géographique de la consommation de soins chirurgicaux est un domaine encore inexploré. Ce rapport examine de manière descriptive trois interventions chirurgicales réalisées en Suisse entre 2003 et 2005 : la prothèse partielle ou totale de hanche, la prothèse de genou et la cure de hernie discale. Il se concentre sur les caractéristiques démographiques des patients opérés, leur diagnostic et les différences des taux d'intervention selon les cantons. Les résultats sont présentés sous forme de taux bruts, de taux standardisés et de cartes géographiques de distribution.
Resumo:
The infection of an intervertebral disk is a serious condition. The diagnosis often is elusive and difficult to make. It is imperative to have appropriate microbiologic specimens before the initiation of treatment. We report the case of a 51-year-old woman with lumbar spondylodiscitis caused by infection after the placement of an epidural catheter for postoperative analgesia. A spinal magnetic resonance imaging (MRI) scan confirmed the diagnosis, but computed tomography (CT)-guided fine-needle biopsy did not yield adequate material for a microbiologic diagnosis. Laparoscopic biopsies of the involved disk provided good specimens and a diagnosis of Propionibacterium acnes infection. We believe that this minimally invasive procedure should be performed when CT-guided fine-needle biopsy fails to yield a microbiologic diagnosis in spondylodiscitis.
Resumo:
Vertebroplasty and kyphoplasty have been reported to alter the mechanical behavior of the treated and adjacent-level segments, and have been suggested to increase the risk for adjacent-level fractures. The intervertebral disc (IVD) plays an important role in the mechanical behavior of vertebral motion segments. Comparisons between normal and degenerative IVD motion segments following cement augmentation have yet to be reported. A microstructural finite element model of a degenerative IVD motion segment was constructed from micro-CT images. Microdamage within the vertebral body trabecular structure was used to simulate a slightly (I = 83.5% of intact stiffness), moderately (II = 57.8% of intact stiffness), and severely (III = 16.0% of intact stiffness) damaged motion segment. Six variable geometry single-segment cement repair strategies (models A-F) were studied at each damage level (I-III). IVD and bone stresses, and motion segment stiffness, were compared with the intact and baseline damage models (untreated), as well as, previous findings using normal IVD models with the same repair strategies. Overall, small differences were observed in motion segment stiffness and average stresses between the degenerative and normal disc repair models. We did however observe a reduction in endplate bulge and a redistribution in the microstructural tissue level stresses across both endplates and in the treated segment following early stage IVD degeneration. The cement augmentation strategy placing bone cement along the periphery of the vertebra (model E) proved to be the most advantageous in treating the degenerative IVD models by showing larger reductions in the average bone stresses (vertebral and endplate) as compared to the normal IVD models. Furthermore, only this repair strategy, and the complete cement fill strategy (model F), were able to restore the slightly damaged (I) motion segment stiffness above pre-damaged (intact) levels. Early stage IVD degeneration does not have an appreciable effect in motion segment stiffness and average stresses in the treated and adjacent-level segments following vertebroplasty and kyphoplasty. Placing bone cement in the periphery of the damaged vertebra in a degenerative IVD motion segment, minimizes load transfer, and may reduce the likelihood of adjacent-level fractures.
Resumo:
Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.
Resumo:
Infection of an intervertebral disk is a serious condition. Diagnosis often is elusive and difficult. It is imperative to obtain appropriate microbiological specimens before initiation of treatment. The authors describe a 51-year-old woman with lumbar spondylodiscitis that was because of infection after the placement of an epidural catheter for postoperative analgesia. A spinal magnetic resonance imaging confirmed the diagnosis, but computed tomography-guided fine needle biopsy did not provide adequate material for a microbiologic diagnosis. Laparoscopic biopsies of the involved disk provided good specimens and a diagnosis of Propionibacterium acnes infection. The authors believe that this minimally invasive procedure should be performed when computed tomography-guided fine needle biopsy does not provide a microbiologic diagnosis in spondylodiscitis.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
The determination of characteristic cardiac parameters, such as displacement, stress and strain distribution are essential for an understanding of the mechanics of the heart. The calculation of these parameters has been limited until recently by the use of idealised mathematical representations of biventricular geometries and by applying simple material laws. On the basis of 20 short axis heart slices and in consideration of linear and nonlinear material behaviour we have developed a FE model with about 100,000 degrees of freedom. Marching Cubes and Phong's incremental shading technique were used to visualise the three dimensional geometry. In a quasistatic FE analysis continuous distribution of regional stress and strain corresponding to the endsystolic state were calculated. Substantial regional variation of the Von Mises stress and the total strain energy were observed at all levels of the heart model. The results of both the linear elastic model and the model with a nonlinear material description (Mooney-Rivlin) were compared. While the stress distribution and peak stress values were found to be comparable, the displacement vectors obtained with the nonlinear model were generally higher in comparison with the linear elastic case indicating the need to include nonlinear effects.
Resumo:
Direct absolute dating of the Penninic Frontal Thrust tectonic motion is achieved using the Ar-40/Ar-39 technique in the Pelvoux Crystalline Massif (Western Alps). The dated phengites were formed syn-kinematically in shear zones. They underline the brittle-ductile stretching lineation, pressure-shadow fibres and slickensides consistent with underthrusting of the European continental slab below the propagating Penninic Thrust. Chlorite-phengite thermobarometry yields 10-15 km and T similar to 280 degrees C, while Ar-40/Ar-39 phengite ages mainly range between 34 and 30 Ma, with one younger age at 27 Ma. This Early Oligocene age range matches a major tectonic rearrangement of the Alpine chain. Preservation of prograde Ar-40/Ar-39 ages is ascribed to passive exhumation of the Pelvoux shear zone network, sandwiched between more external thrusts and the Penninic Front reactivated as an E-dipping detachment fault. Partial resetting in the Low Temperature part of argon spectra below 24 Ma is ascribed to brittle deformation and alteration of phengites.
Resumo:
Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.
Resumo:
We report on the modelling and experimental validation of a photopolymerizable hydrogel for a Nucleus Pulposus replacement.
Resumo:
Dynamic mixtures of Rh-dye complexes can be used to determine the history of chemical events such as the addition of ATP and ADP by UV-vis spectroscopy.
Resumo:
Geographic differences in frequency and azole resistance among Candida glabrata may impact empiric antifungal therapy choice. We examined geographic variation in isolation and azole susceptibility of C. glabrata. We examined 23 305 clinical isolates of C. glabrata during ARTEMIS DISK global surveillance. Susceptibility testing to fluconazole and voriconazole was assessed by disk diffusion, and the results were grouped by geographic location: North America (NA) (2470 isolates), Latin America (LA) (2039), Europe (EU) (12 439), Africa and the Middle East (AME) (728), and Asia-Pacific (AP) (5629). Overall, C. glabrata accounted for 11.6% of 201 653 isolates of Candida and varied as a proportion of all Candida isolated from 7.4% in LA to 21.1% in NA. Decreased susceptibility (S) to fluconazole was observed in all geographic regions and ranged from 62.8% in AME to 76.7% in LA. Variation in fluconazole susceptibility was observed within each region: AP (range, 50-100% S), AME (48-86.9%), EU (44.8-88%), LA (43-92%), and NA (74.5-91.6%). Voriconazole was more active than fluconazole (range, 82.3-84.2% S) with similar regional variation. Among 22 sentinel sites participating in ARTEMIS from 2001 through 2007 (84 140 total isolates, 8163 C. glabrata), the frequency of C. glabrata isolation increased in 14 sites and the frequency of fluconazole resistance (R) increased in 11 sites over the 7-year period of study. The sites with the highest cumulative rates of fluconazole R were in Poland (22% R), the Czech Republic (27% R), Venezuela (27% R), and Greece (33% R). C. glabrata was most often isolated from blood, normally sterile body fluids and urine. There is substantial geographic and institutional variation in both frequency of isolation and azole resistance among C. glabrata. Prompt species identification and fluconazole susceptibility testing are necessary to optimize therapy for invasive candidiasis.