185 resultados para Interactive Express Statistical System (Electronic computer system)
em Université de Lausanne, Switzerland
Resumo:
The state of the art to describe image quality in medical imaging is to assess the performance of an observer conducting a task of clinical interest. This can be done by using a model observer leading to a figure of merit such as the signal-to-noise ratio (SNR). Using the non-prewhitening (NPW) model observer, we objectively characterised the evolution of its figure of merit in various acquisition conditions. The NPW model observer usually requires the use of the modulation transfer function (MTF) as well as noise power spectra. However, although the computation of the MTF poses no problem when dealing with the traditional filtered back-projection (FBP) algorithm, this is not the case when using iterative reconstruction (IR) algorithms, such as adaptive statistical iterative reconstruction (ASIR) or model-based iterative reconstruction (MBIR). Given that the target transfer function (TTF) had already shown it could accurately express the system resolution even with non-linear algorithms, we decided to tune the NPW model observer, replacing the standard MTF by the TTF. It was estimated using a custom-made phantom containing cylindrical inserts surrounded by water. The contrast differences between the inserts and water were plotted for each acquisition condition. Then, mathematical transformations were performed leading to the TTF. As expected, the first results showed a dependency of the image contrast and noise levels on the TTF for both ASIR and MBIR. Moreover, FBP also proved to be dependent of the contrast and noise when using the lung kernel. Those results were then introduced in the NPW model observer. We observed an enhancement of SNR every time we switched from FBP to ASIR to MBIR. IR algorithms greatly improve image quality, especially in low-dose conditions. Based on our results, the use of MBIR could lead to further dose reduction in several clinical applications.
Resumo:
BACKGROUND: Cilengitide is a selective αvβ3 and αvβ5 integrin inhibitor. Data from phase 2 trials suggest that it has antitumour activity as a single agent in recurrent glioblastoma and in combination with standard temozolomide chemoradiotherapy in newly diagnosed glioblastoma (particularly in tumours with methylated MGMT promoter). We aimed to assess cilengitide combined with temozolomide chemoradiotherapy in patients with newly diagnosed glioblastoma with methylated MGMT promoter. METHODS: In this multicentre, open-label, phase 3 study, we investigated the efficacy of cilengitide in patients from 146 study sites in 25 countries. Eligible patients (newly diagnosed, histologically proven supratentorial glioblastoma, methylated MGMT promoter, and age ≥18 years) were stratified for prognostic Radiation Therapy Oncology Group recursive partitioning analysis class and geographic region and centrally randomised in a 1:1 ratio with interactive voice response system to receive temozolomide chemoradiotherapy with cilengitide 2000 mg intravenously twice weekly (cilengitide group) or temozolomide chemoradiotherapy alone (control group). Patients and investigators were unmasked to treatment allocation. Maintenance temozolomide was given for up to six cycles, and cilengitide was given for up to 18 months or until disease progression or unacceptable toxic effects. The primary endpoint was overall survival. We analysed survival outcomes by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00689221. FINDINGS: Overall, 3471 patients were screened. Of these patients, 3060 had tumour MGMT status tested; 926 patients had a methylated MGMT promoter, and 545 were randomly assigned to the cilengitide (n=272) or control groups (n=273) between Oct 31, 2008, and May 12, 2011. Median overall survival was 26·3 months (95% CI 23·8-28·8) in the cilengitide group and 26·3 months (23·9-34·7) in the control group (hazard ratio 1·02, 95% CI 0·81-1·29, p=0·86). None of the predefined clinical subgroups showed a benefit from cilengitide. We noted no overall additional toxic effects with cilengitide treatment. The most commonly reported adverse events of grade 3 or worse in the safety population were lymphopenia (31 [12%] in the cilengitide group vs 26 [10%] in the control group), thrombocytopenia (28 [11%] vs 46 [18%]), neutropenia (19 [7%] vs 24 [9%]), leucopenia (18 [7%] vs 20 [8%]), and convulsion (14 [5%] vs 15 [6%]). INTERPRETATION: The addition of cilengitide to temozolomide chemoradiotherapy did not improve outcomes; cilengitide will not be further developed as an anticancer drug. Nevertheless, integrins remain a potential treatment target for glioblastoma. FUNDING: Merck KGaA, Darmstadt, Germany.
Resumo:
BACKGROUND: Interleukin 6 is involved in the pathogenesis of rheumatoid arthritis via its broad effects on immune and inflammatory responses. Our aim was to assess the therapeutic effects of blocking interleukin 6 by inhibition of the interleukin-6 receptor with tocilizumab in patients with rheumatoid arthritis. METHODS: In this double-blind, randomised, placebo-controlled, parallel group phase III study, 623 patients with moderate to severe active rheumatoid arthritis were randomly assigned with an interactive voice response system, stratified by site with a randomisation list provided by the study sponsor, to receive tocilizumab 8 mg/kg (n=205), tocilizumab 4 mg/kg (214), or placebo (204) intravenously every 4 weeks, with methotrexate at stable pre-study doses (10-25 mg/week). Rescue therapy with tocilizumab 8 mg/kg was offered at week 16 to patients with less than 20% improvement in both swollen and tender joint counts. The primary endpoint was the proportion of patients with 20% improvement in signs and symptoms of rheumatoid arthritis according to American College of Rheumatology criteria (ACR20 response) at week 24. Analyses were by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00106548. FINDINGS: The intention-to-treat analysis population consisted of 622 patients: one patient in the 4 mg/kg group did not receive study treatment and was thus excluded. At 24 weeks, ACR20 responses were seen in more patients receiving tocilizumab than in those receiving placebo (120 [59%] patients in the 8 mg/kg group, 102 [48%] in the 4 mg/kg group, 54 [26%] in the placebo group; odds ratio 4.0 [95% CI 2.6-6.1], p<0.0001 for 8 mg/kg vs placebo; and 2.6 [1.7-3.9], p<0.0001 for 4 mg/kg vs placebo). More people receiving tocilizumab than those receiving placebo had at least one adverse event (143 [69%] in the 8 mg/kg group; 151 [71%] in the 4 mg/kg group; 129 [63%] in the placebo group). The most common serious adverse events were serious infections or infestations, reported by six patients in the 8 mg/kg group, three in the 4 mg/kg group, and two in the placebo group. INTERPRETATION: Tocilizumab could be an effective therapeutic approach in patients with moderate to severe active rheumatoid arthritis. FUNDING: F Hoffmann-La Roche, Chugai Pharmaceutical.
Resumo:
Angiotensin (Ang) II has for long been identified as a neuropeptide located within neurons and pathways of the central nervous system involved in the control of thirst and cardio-vascular homeostasis. The presence of Ang II in ganglionic neurons of celiac, dorsal root, and trigeminal ganglia has only recently been described in humans and rats. Ang II-containing fibers were also found in the mesenteric artery and the heart, together with intrinsic Ang II-containing cardiac neurons. Ganglionic neurons express angiotensinogen and co-localize it with Ang II. Its intraneuronal production as a neuropeptide appears to involve angiotensinogen processing enzymes other than renin. Immunocytochemical and gene expression data suggest that neuronal Ang II acts as a neuromodulatory peptide and co-transmitter in the peripheral autonomic, and also sensory nervous system. Neuronal Ang II probably competes with humoral Ang II for effector cell activation. Its functional role, however, still remains to be determined. Angiotensinergic neurotransmission in the autonomic nervous system is a potential new target for therapeutic interventions in many common diseases such as essential hypertension, heart failure, and cardiac arrhythmia.
Resumo:
The MyHits web server (http://myhits.isb-sib.ch) is a new integrated service dedicated to the annotation of protein sequences and to the analysis of their domains and signatures. Guest users can use the system anonymously, with full access to (i) standard bioinformatics programs (e.g. PSI-BLAST, ClustalW, T-Coffee, Jalview); (ii) a large number of protein sequence databases, including standard (Swiss-Prot, TrEMBL) and locally developed databases (splice variants); (iii) databases of protein motifs (Prosite, Interpro); (iv) a precomputed list of matches ('hits') between the sequence and motif databases. All databases are updated on a weekly basis and the hit list is kept up to date incrementally. The MyHits server also includes a new collection of tools to generate graphical representations of pairwise and multiple sequence alignments including their annotated features. Free registration enables users to upload their own sequences and motifs to private databases. These are then made available through the same web interface and the same set of analytical tools. Registered users can manage their own sequences and annotations using only web tools and freeze their data in their private database for publication purposes.
Resumo:
The odour of acids has a distinct quality that is perceived as sharp, pungent and often irritating. How acidity is sensed and translated into an appropriate behavioural response is poorly understood. Here we describe a functionally segregated population of olfactory sensory neurons in the fruitfly, Drosophila melanogaster, that are highly selective for acidity. These olfactory sensory neurons express IR64a, a member of the recently identified ionotropic receptor (IR) family of putative olfactory receptors. In vivo calcium imaging showed that IR64a+ neurons projecting to the DC4 glomerulus in the antennal lobe are specifically activated by acids. Flies in which the function of IR64a+ neurons or the IR64a gene is disrupted had defects in acid-evoked physiological and behavioural responses, but their responses to non-acidic odorants remained unaffected. Furthermore, artificial stimulation of IR64a+ neurons elicited avoidance responses. Taken together, these results identify cellular and molecular substrates for acid detection in the Drosophila olfactory system and support a labelled-line mode of acidity coding at the periphery.
Resumo:
Biochemical systems are commonly modelled by systems of ordinary differential equations (ODEs). A particular class of such models called S-systems have recently gained popularity in biochemical system modelling. The parameters of an S-system are usually estimated from time-course profiles. However, finding these estimates is a difficult computational problem. Moreover, although several methods have been recently proposed to solve this problem for ideal profiles, relatively little progress has been reported for noisy profiles. We describe a special feature of a Newton-flow optimisation problem associated with S-system parameter estimation. This enables us to significantly reduce the search space, and also lends itself to parameter estimation for noisy data. We illustrate the applicability of our method by applying it to noisy time-course data synthetically produced from previously published 4- and 30-dimensional S-systems. In addition, we propose an extension of our method that allows the detection of network topologies for small S-systems. We introduce a new method for estimating S-system parameters from time-course profiles. We show that the performance of this method compares favorably with competing methods for ideal profiles, and that it also allows the determination of parameters for noisy profiles.
Resumo:
OBJECTIVES: The objectives were to identify the social and medical factors associated with emergency department (ED) frequent use and to determine if frequent users were more likely to have a combination of these factors in a universal health insurance system. METHODS: This was a retrospective chart review case-control study comparing randomized samples of frequent users and nonfrequent users at the Lausanne University Hospital, Switzerland. The authors defined frequent users as patients with four or more ED visits within the previous 12 months. Adult patients who visited the ED between April 2008 and March 2009 (study period) were included, and patients leaving the ED without medical discharge were excluded. For each patient, the first ED electronic record within the study period was considered for data extraction. Along with basic demographics, variables of interest included social (employment or housing status) and medical (ED primary diagnosis) characteristics. Significant social and medical factors were used to construct a logistic regression model, to determine factors associated with frequent ED use. In addition, comparison of the combination of social and medical factors was examined. RESULTS: A total of 359 of 1,591 frequent and 360 of 34,263 nonfrequent users were selected. Frequent users accounted for less than a 20th of all ED patients (4.4%), but for 12.1% of all visits (5,813 of 48,117), with a maximum of 73 ED visits. No difference in terms of age or sex occurred, but more frequent users had a nationality other than Swiss or European (n = 117 [32.6%] vs. n = 83 [23.1%], p = 0.003). Adjusted multivariate analysis showed that social and specific medical vulnerability factors most increased the risk of frequent ED use: being under guardianship (adjusted odds ratio [OR] = 15.8; 95% confidence interval [CI] = 1.7 to 147.3), living closer to the ED (adjusted OR = 4.6; 95% CI = 2.8 to 7.6), being uninsured (adjusted OR = 2.5; 95% CI = 1.1 to 5.8), being unemployed or dependent on government welfare (adjusted OR = 2.1; 95% CI = 1.3 to 3.4), the number of psychiatric hospitalizations (adjusted OR = 4.6; 95% CI = 1.5 to 14.1), and the use of five or more clinical departments over 12 months (adjusted OR = 4.5; 95% CI = 2.5 to 8.1). Having two of four social factors increased the odds of frequent ED use (adjusted = OR 5.4; 95% CI = 2.9 to 9.9), and similar results were found for medical factors (adjusted OR = 7.9; 95% CI = 4.6 to 13.4). A combination of social and medical factors was markedly associated with ED frequent use, as frequent users were 10 times more likely to have three of them (on a total of eight factors; 95% CI = 5.1 to 19.6). CONCLUSIONS: Frequent users accounted for a moderate proportion of visits at the Lausanne ED. Social and medical vulnerability factors were associated with frequent ED use. In addition, frequent users were more likely to have both social and medical vulnerabilities than were other patients. Case management strategies might address the vulnerability factors of frequent users to prevent inequities in health care and related costs.
Resumo:
Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.
Resumo:
Analysis of variance is commonly used in morphometry in order to ascertain differences in parameters between several populations. Failure to detect significant differences between populations (type II error) may be due to suboptimal sampling and lead to erroneous conclusions; the concept of statistical power allows one to avoid such failures by means of an adequate sampling. Several examples are given in the morphometry of the nervous system, showing the use of the power of a hierarchical analysis of variance test for the choice of appropriate sample and subsample sizes. In the first case chosen, neuronal densities in the human visual cortex, we find the number of observations to be of little effect. For dendritic spine densities in the visual cortex of mice and humans, the effect is somewhat larger. A substantial effect is shown in our last example, dendritic segmental lengths in monkey lateral geniculate nucleus. It is in the nature of the hierarchical model that sample size is always more important than subsample size. The relative weight to be attributed to subsample size thus depends on the relative magnitude of the between observations variance compared to the between individuals variance.
Resumo:
With increased activity and reduced financial and human resources, there is a need for automation in clinical bacteriology. Initial processing of clinical samples includes repetitive and fastidious steps. These tasks are suitable for automation, and several instruments are now available on the market, including the WASP (Copan), Previ-Isola (BioMerieux), Innova (Becton-Dickinson) and Inoqula (KIESTRA) systems. These new instruments allow efficient and accurate inoculation of samples, including four main steps: (i) selecting the appropriate Petri dish; (ii) inoculating the sample; (iii) spreading the inoculum on agar plates to obtain, upon incubation, well-separated bacterial colonies; and (iv) accurate labelling and sorting of each inoculated media. The challenge for clinical bacteriologists is to determine what is the ideal automated system for their own laboratory. Indeed, different solutions will be preferred, according to the number and variety of samples, and to the types of sample that will be processed with the automated system. The final choice is troublesome, because audits proposed by industrials risk being biased towards the solution proposed by their company, and because these automated systems may not be easily tested on site prior to the final decision, owing to the complexity of computer connections between the laboratory information system and the instrument. This article thus summarizes the main parameters that need to be taken into account for choosing the optimal system, and provides some clues to help clinical bacteriologists to make their choice.
Resumo:
The urate transporter, GLUT9, is responsible for the basolateral transport of urate in the proximal tubule of human kidneys and in the placenta, playing a central role in uric acid homeostasis. GLUT9 shares the least homology with other members of the glucose transporter family, especially with the glucose transporting members GLUT1-4 and is the only member of the GLUT family to transport urate. The recently published high-resolution structure of XylE, a bacterial D-xylose transporting homologue, yields new insights into the structural foundation of this GLUT family of proteins. While this represents a huge milestone, it is unclear if human GLUT9 can benefit from this advancement through subsequent structural based targeting and mutagenesis. Little progress has been made toward understanding the mechanism of GLUT9 since its discovery in 2000. Before work can begin on resolving the mechanisms of urate transport we must determine methods to express, purify and analyze hGLUT9 using a model system adept in expressing human membrane proteins. Here, we describe the surface expression, purification and isolation of monomeric protein, and functional analysis of recombinant hGLUT9 using the Xenopus laevis oocyte system. In addition, we generated a new homology-based high-resolution model of hGLUT9 from the XylE crystal structure and utilized our purified protein to generate a low-resolution single particle reconstruction. Interestingly, we demonstrate that the functional protein extracted from the Xenopus system fits well with the homology-based model allowing us to generate the predicted urate-binding pocket and pave a path for subsequent mutagenesis and structure-function studies.
Resumo:
The adaptive function of melanin-based coloration is a long-standing debate. A recent genetic model suggested that pleiotropy could account for covariations between pigmentation, behaviour, morphology, physiology and life history traits. We explored whether the expression levels of genes belonging to the melanocortin system (MC1R, POMC, PC1/3, PC2 and the antagonist ASIP), which have many pleiotropic effects, are associated with melanogenesis (through variation in the expression of the genes MITF, SLC7A11, TYR, TYRP1) and in turn melanin-based coloration. We considered the tawny owl (Strix aluco) because individuals vary continuously from light to dark reddish, and thus, colour variation is likely to stem from differences in the levels of gene expression. We measured gene expression in feather bases collected in nestlings at the time of melanin production. As expected, the melanocortin system was associated with the expression of melanogenic genes and pigmentation. Offspring of darker reddish fathers expressed PC1/3 to lower levels but tended to express PC2 to higher levels. The convertase enzyme PC1/3 cleaves the POMC prohormone to obtain ACTH, while the convertase enzyme PC2 cleaves ACTH to produce α-melanin-stimulating hormone (α-MSH). ACTH regulates glucocorticoids, hormones that modulate stress responses, while α-MSH induces eumelanogenesis. We therefore conclude that the melanocortin system, through the convertase enzymes PC1/3 and PC2, may account for part of the interindividual variation in melanin-based coloration in nestling tawny owls. Pleiotropy may thus account for the covariation between phenotypic traits involved in social interactions (here pigmentation) and life history, morphology, behaviour and physiology.
Resumo:
OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."