130 resultados para Inseminacao artificial animal : Suinos
em Université de Lausanne, Switzerland
Resumo:
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.
Resumo:
Introduction and objectives: The AMS 800TM is considered the gold standard for sphincter replacement. However, the one-ring design can erode the urethra and lead to severe complications. A mechanism that could alternatively compress successive segments of the urethra would limit such deleterious outcome. We report 12 weeks animal urethral tissue analysis following implantation of a new modular artificial sphincter. METHODS: The device is composed by three parts: the contractile unit, two rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor connected to an external computer. The computer can reveal specific failure of device components. The device was impkanted in eight male sheep. The rings were positioned around the urethra and the control unit was placed 5cm away. The device was working twenty hours per day; it was open 10min. per hour to allow urination. The animals were sacrificed after 12 weeks. The urethra and the tissues surrounding the control unit were macroscopically and microscopically examined. Two transversal sections crossing the sphincter and two transversal sections crossing the urethra alone were obtained and stained with modified Paragon after resin embedding. Urethra was also embedded in paraffin. The first section was stained with safranin-hematoxylin-eosin, the second section was stained with Masson's Trichrome and the remaining eight sections were available for immunolabelling of the macrophages.Results: The chronic study went uneventful. No clinical infection or pain was observed. The computer registered no specific failure in ring function, Nitinol wires and tube connectors. At explantation, except for a slight grade of lymphocytes in two out of eight specimens, no urethral stricture or atrophy could be observed. Immunohistochemistry confirmed the absence of macrophages. Tissue structure and organization of the urethra with and without artificial sphincter were similar. No migration of the device was observed.Conclusions: The study clearly showed no tissue damage or inflammation of the urethra. Electronic design, preservation of urethral vascularisation and adjustability after implantation are the key ideas to improve the actual AUS. Further studies will be carried out to evaluate this potential.
Resumo:
Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.
Resumo:
BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.
Resumo:
The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.
Resumo:
La modélisation, chez l'animal, de maladies psychiatriques telles que la schizophrénie repose sur différentes démarches visant à induire des perturbations cérébrales similaires à celles observées dans la maladie. Nous avons cherché à étudier chez le rat les effets d'une diminution (50%) transitoire en glutathion (GSH) durant le développement (PND 5 à PND 16) à partir de l'implication, chez des adultes, des conséquences de cette perturbation dans des mécanismes fondamentaux de traitement de l'information sensorielle. Cette thèse évalue et documente les déficits de compétences de navigation spatiale dans ce modèle. Nous avons mis en évidence des effets comportementaux à partir de l'identification de différences particulières dans des tâches d'orientation: des difficultés, chez les rats ayant subi un déficit en GSH, à élaborer une représentation globale de l'environnement dans lequel ils se déplacent, difficultés compensées par une attention particulière aux détails visuels le composant. Cette stratégie réactive compensatoire est efficace lorsque les conditions permettent un ajustement continu aux repères visuels environnementaux. Elle ne permet cependant pas des prédictions et des attentes sur ce qui devrait être rencontré et perçu dans une certaine direction, dès qu'une partie des informations visuelles familières disparaît. Il faudrait pour cela une capacité fondée sur une représentation abstraite, à distance des modalités sensorielles qui en ont permis son élaboration. Notre thèse soutient que les déficits, supposés participer à l'émergence de certains symptômes de la maladie, auraient également des conséquences sur l'élaboration de la représentation spatiale nécessaire à des capacités d'orientation effectives et symboliques. - The study of a psychiatric disease such as schizophrenia in an animal model relies on different approaches attempting to replicate brain perturbations similar to those observed in the illness. In the present work, behavioural consequences of a functional deficit in brain connectivity and coordination were assessed in rats with a transitory glutathione (GSH) deficit induced during the postnatal development (PND 5-PND 16) with daily injections of BSO (1- buthionine-(S,R)- sulfoximine). We searched for a theoretical syndrome associating ecologically relevant behavioural adaptive deficits and resulting from the weakening of sensory integration processes. Our results revealed significant and specific deficit of BSO treated rats in spatial orientation tasks designed to test for cognitive mapping abilities. Treated rats behaved as if impaired in the proactive strategies supported by an abstract representation such as a cognitive map. In contrast their performances were preserved whenever the environmental conditions allowed for adaptative reactive strategies, an equivalent of the visual affordances described by Gibson (1958). This supports our thesis that BSO treated rats expressed difficulties in elaborating a global representation of the environment. This deficit was completely - or - partially compensated by the development of an increased attention to the environment's visual details. This compensatory reactive strategy requires a rich environment allowing for continuous adjustment to visual cues. However, such adjustment doesn't allow to predictions and expectancies about what should be met and perceived in a certain direction, when familiar visual spatial cues are missing. Such competencies require orientation based on the use of an abstract spatial representation, independent from the specific sensory modalities that have participated to its elaboration. The impairment of BSO rats such spatial representation could result from a deficit in the integration and organization of perceptual information. Our model leads to the hypothesis that these fundamental deficits might account for certain symptoms of schizophrenia. They would also interfere with in the capacity to elaborate spatial representation necessary for optimal orientation in natural, artificial or symbolic environment.
Resumo:
Objectives: The AMS 800 is the current artifi cial urinary sphincter (AUS) forincontinence due to intrinsic sphincter defi ciency. Despite good clinical results,technical failures inherent to the hydraulic mechanism or urethral ischemicinjury contribute to revisions up to 60%. We are developing an electronic AUS,called ARTUS to overcome the rigors of AMS. The objective of this study wasto evaluate the technical effi cacy and tissue tolerance of the ARTUS systemin an animal model.Methods: The ARTUS is composed by three parts: thecontractile unit, a series of rings and an integrated microprocessor. The contractileunit is made of Nitinol fi bers. The rings are placed around the urethrato control the fl ow of urine by squeezing the urethra. They work in a sequentialalternative mode and are controlled by a microprocessor. In the fi rst phase athree-rings device was used while in the second phase a two-rings ARTUS wasused. The device was implanted in 14 sheep divided in two groups of six andeight animals for study purpose. The fi rst group aimed at bladder leak pointpressure (BLPP) measurement and validation of the animal model; the secondgroup aimed at verifying midterm tissue tolerance by explants at twelve weeks.General animal tolerance was also evaluated.Results: The ARTUS systemimplantation was uneventful. When the system was activated, the BLPP wasmeasured at 1.038 ± 0.044 bar (mean ± SD). Urethral tissue analysis did notshow signifi cant morphological changes. No infection and no sign of discomfortwere noted in animals at 12 weeks.Conclusions: The ARTUS proved to beeffective in continence achievement in this study. Histological results supportour idea that a sequential alternative mode can avoid urethral atrophy andischemia. Further technical developments are needed to verify long-termoutcome and permit human use.
Resumo:
Cataract surgery is a common ocular surgical procedure consisting in the implantation of an artificial intraocular lens (IOL) to replace the ageing, dystrophic or damaged natural one. The management of postoperative ocular inflammation is a major challenge especially in the context of pre-existing uveitis. The association of the implanted IOL with a drug delivery system (DDS) allows the prolonged intraocular release of anti-inflammatory agents after surgery. Thus IOL-DDS represents an "all in one" strategy that simultaneously addresses both cataract and inflammation issues. Polymeric DDS loaded with two model anti-inflammatory drugs (triamcinolone acetonide (TA) and cyclosporine A (CsA)) were manufactured in a novel way and tested regarding their efficiency for the management of intraocular inflammation during the 3 months following surgery. The study involved an experimentally induced uveitis in rabbits. Experimental results showed that medicated DDS efficiently reduced ocular inflammation (decrease of protein concentration in aqueous humour, inflammatory cells in aqueous humour and clinical score). Additionally, more than 60% of the loading dose remained in the DDS at the end of the experiment, suggesting that the system could potentially cover longer inflammatory episodes. Thus, IOL-DDS were demonstrated to inhibit intraocular inflammation for at least 3 months after cataract surgery, representing a potential novel approach to cataract surgery in eyes with pre-existing uveitis.
Resumo:
Résumé: Introduction : L'utilisation de méthodes endoscopiques peu invasives est en constante augmentation pour le traitement des lésions tumorales précoces de l'oesophage. Le but du traitement comprend l'éradication complète de tous les foyers de dysplasie ou de carcinome in situ, notamment dans les métaplasies intestinales de l'oesophage de Barrett, qui peuvent dégénérer en adénocarcinome. Plusieurs techniques d'ablation de la muqueuse oesophagienne (laser, argon plasma, electrocoagulation, photothérapie dynamique, résection endoscopique) ont été utilisées jusqu'à présent, mais aucune n'a vraiment donné entière satisfaction. Les techniques actuelles de résections endoscopiques par fibroscopie sont entre autres limitées par le grand nombre de séances nécessaires à l'éradication complète de la lésion et par la petite taille des fragments de muqueuse obtenus, ce qui rend l'analyse histologique difficile. Dans notre étude animale, nous avons évalué la faisabilité, l'efficacité et la sécurité d'une méthode de résection endoscopique à l'aide d'un nouvel oesophagoscope rigide. Matériel et méthode : Le résectoscope est formé d'un oesophagoscope rigide avec une fenêtre distale transparente à travers laquelle la muqueuse et une partie de la sous-muqueuse sont aspirées et ensuite réséquées avec une anse thermique. Les diverses fenêtres utilisées ont une taille comprise entre 2.2 et 4.4 cm. Le mouton a été choisi en raison de la ressemblance de son oesophage avec celui de l'humain en ce qui concerne l'épaisseur de son oesophage et sa structure histologique. Nous avons effectué 55 résections hémi-circonférentielles sur 21 animaux et 11 résections circonférentielles sur 11 autres. La Mitomycine-C, une substance qui inhibe la prolifération fibroblastique, a été utilisée dans 8 résections circonférentielles à différents intervalles de temps afin d'empêcher la survenue de sténoses oesophagiennes. Résultats : Toutes les résections hémi-circonférentielles ont permis d'obtenir des fragments compacts de tissu avec des bords nets, ce qui permet une excellente étude histologique. La surface du tissu prélevé était en corrélation avec la taille de la fenêtre du resectoscope. Nous avons ainsi pu obtenir des fragments avec des dimensions comprises entre 6 et 12 cm2. Pour les résections circonférentielles, les tissus étaient obtenus en 2 parties, en inversant de 180° la position de l'appareil. La profondeur de la résection a été optimale dans 58 cas sur 65 avec une découpe précise au niveau de la sous-muqueuse sans lésion de la couche musculaire sous- jacente. Il n'y a pas eu de complications après les résections hémi-circonférentielles. Les complications engendrées par les résections circonférentielles (sténose, perforation) n'ont plus été rencontrées après application locale de Mitomycine-C administrée à des intervalles de temps bien précis. Conclusion : Notre méthode de résection endoscopique de la muqueuse oesophagienne offre une nouvelle approche très prometteuse par rapport aux options déjà disponibles. Elle apparaît supérieure en ce qui concerne la taille de tissu prélevé, la précision et régularité de la profondeur de résection, ainsi que la facilité et sûreté du diagnostic histologique et des marges de sécurité. Les résections hémi-circonférentielles se sont révélées sûres chez le modèle animal. Cette nouvelle technique mérite de plus amples investigations pour les résections circonférentielles avant son utilisation chez l'humain. Abstract: Background and Study Aims: We undertook this retrospective study to evaluate the frequency and prognosis of endoscopic treatment of laterally spreading tumors (LSTs) in the rectum. The recurrence rate for lesions of the lower rectum was compared with that of the upper rectum. Patients and Methods: During the period from July 1989 to June 2002, a total of 1237 rectal tumors were detected. LSTs accounted for 6.9% (85/1237) of all rectal tumors. A total of 224 tumors of the lower rectum were detected among the 1237 rectal tumors. LSTs accounted for 16.1 % (36/224) of all the lower rectal tumors. From 85 LST lesions, 67 were evaluated for their prognosis after endoscopic mucosal resection (EMR). Patients whose LSTs had been resected were followed up by endoscopy at the following frequencies: once 15 (22.4%); twice (more than 1 year), 20 (29.9%); three times (more than 3 years), 21(31.3%); and four times or more (more than 5 years), 11 (16.4%). Results: A total of 67 patients with endoscopically treated LSTs were followed up by endoscopy. We observed recurrences in two lesions of the upper rectum (2/38, 5.3%) and five lesions of the lower rectum (5/29, 17.2%) (P = 0.2364); all seven lesions were resected piecemeal. LSTs whose horizontal margin reached the pectinate line frequently recurred in the lower rectum, at a rate of 80% (4/5). However, all patients were completely cured by additional endoscopic resections, the greatest number of treatments being four. Conclusion: For early detection of recurrence and successful endoscopic cure, further colonoscopic examination within a few months after the first treatment is necessary.
Resumo:
Bone defects in revision knee arthroplasty are often located in load-bearing regions. The goal of this study was to determine whether a physiologic load could be used as an in situ osteogenic signal to the scaffolds filling the bone defects. In order to answer this question, we proposed a novel translation procedure having four steps: (1) determining the mechanical stimulus using finite element method, (2) designing an animal study to measure bone formation spatially and temporally using micro-CT imaging in the scaffold subjected to the estimated mechanical stimulus, (3) identifying bone formation parameters for the loaded and non-loaded cases appearing in a recently developed mathematical model for bone formation in the scaffold and (4) estimating the stiffness and the bone formation in the bone-scaffold construct. With this procedure, we estimated that after 3 years mechanical stimulation increases the bone volume fraction and the stiffness of scaffold by 1.5- and 2.7-fold, respectively, compared to a non-loaded situation.
Resumo:
Much attention has been paid to the effects of climate change on species' range reductions and extinctions. There is however surprisingly little information on how climate change driven threat may impact the tree of life and result in loss of phylogenetic diversity (PD). Some plant families and mammalian orders reveal nonrandom extinction patterns, but many other plant families do not. Do these discrepancies reflect different speciation histories and does climate induced extinction result in the same discrepancies among different groups? Answers to these questions require representative taxon sampling. Here, we combine phylogenetic analyses, species distribution modeling, and climate change projections on two of the largest plant families in the Cape Floristic Region (Proteaceae and Restionaceae), as well as the second most diverse mammalian order in Southern Africa (Chiroptera), and an herbivorous insect genus (Platypleura) in the family Cicadidae to answer this question. We model current and future species distributions to assess species threat levels over the next 70years, and then compare projected with random PD survival. Results for these animal and plant clades reveal congruence. PD losses are not significantly higher under predicted extinction than under random extinction simulations. So far the evidence suggests that focusing resources on climate threatened species alone may not result in disproportionate benefits for the preservation of evolutionary history.
Resumo:
Converging evidence favors an abnormal susceptibility to oxidative stress in schizophrenia. Decreased levels of glutathione (GSH), the major cellular antioxidant and redox regulator, was observed in cerebrospinal-fluid and prefrontal cortex of patients. Importantly, abnormal GSH synthesis of genetic origin was observed: Two case-control studies showed an association with a GAG trinucleotide repeat (TNR) polymorphism in the GSH key synthesizing enzyme glutamate-cysteine-ligase (GCL) catalytic subunit (GCLC) gene. The most common TNR genotype 7/7 was more frequent in controls, whereas the rarest TNR genotype 8/8 was three times more frequent in patients. The disease associated genotypes (35% of patients) correlated with decreased GCLC protein, GCL activity and GSH content. Similar GSH system anomalies were observed in early psychosis patients. Such redox dysregulation combined with environmental stressors at specific developmental stages could underlie structural and functional connectivity anomalies. In pharmacological and knock-out (KO) models, GSH deficit induces anomalies analogous to those reported in patients. (a) morphology: spine density and GABA-parvalbumine immunoreactivity (PV-I) were decreased in anterior cingulate cortex. KO mice showed delayed cortical PV-I at PD10. This effect is exacerbated in mice with increased DA from PD5-10. KO mice exhibit cortical impairment in myelin and perineuronal net known to modulate PV connectivity. (b) physiology: In cultured neurons, NMDA response are depressed by D2 activation. In hippocampus, NMDA-dependent synaptic plasticity is impaired and kainate induced g-oscillations are reduced in parallel to PV-I. (c) cognition: low GSH models show increased sensitivity to stress, hyperactivity, abnormal object recognition, olfactory integration and social behavior. In a clinical study, GSH precursor N-acetyl cysteine (NAC) as add on therapy, improves the negative symptoms and decreases the side effects of antipsychotics. In an auditory oddball paradigm, NAC improves the mismatched negativity, an evoked potential related to pre-attention and to NMDA receptors function. In summary, clinical and experimental evidence converge to demonstrate that a genetically induced dysregulation of GSH synthesis combined with environmental insults in early development represent a major risk factor contributing to the development of schizophrenia Conclusion Based on these data, we proposed a model for PSIP1 promoter activity involving a complex interplay between yet undefined regulatory elements to modulate gene expression.