42 resultados para Inertial forces

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study introduces a novel approach for automatic temporal phase detection and inter-arm coordination estimation in front-crawl swimming using inertial measurement units (IMUs). We examined the validity of our method by comparison against a video-based system. Three waterproofed IMUs (composed of 3D accelerometer, 3D gyroscope) were placed on both forearms and the sacrum of the swimmer. We used two underwater video cameras in side and frontal views as our reference system. Two independent operators performed the video analysis. To test our methodology, seven well-trained swimmers performed three 300 m trials in a 50 m indoor pool. Each trial was in a different coordination mode quantified by the index of coordination. We detected different phases of the arm stroke by employing orientation estimation techniques and a new adaptive change detection algorithm on inertial signals. The difference of 0.2 +/- 3.9% between our estimation and video-based system in assessment of the index of coordination was comparable to experienced operators' difference (1.1 +/- 3.6%). The 95% limits of agreement of the difference between the two systems in estimation of the temporal phases were always less than 7.9% of the cycle duration. The inertial system offers an automatic easy-to-use system with timely feedback for the study of swimming.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fall prevention in elderly subjects is often based on training and rehabilitation programs that include mostly traditional balance and strength exercises. By applying such conventional interventions to improve gait performance and decrease fall risk, some important factors are neglected such as the dynamics of the gait and the motor learning processes. The EU project "Self Mobility Improvement in the eLderly by counteractING falls" (SMILING project) aimed to improve age-related gait and balance performance by using unpredicted external perturbations during walking through motorized shoes that change insole inclination at each stance. This paper describes the shoe-worn inertial module and the gait analysis method needed to control in real-time the shoe insole inclination during training, as well as gait spatio-temporal parameters obtained during long distance walking before and after the 8-week training program that assessed the efficacy of training with these motorized shoes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A child's natural gait pattern may be affected by the gait laboratory environment. Wearable devices using body-worn sensors have been developed for gait analysis. The purpose of this study was to validate and explore the use of foot-worn inertial sensors for the measurement of selected spatio-temporal parameters, based on the 3D foot trajectory, in independently walking children with cerebral palsy (CP). We performed a case control study with 14 children with CP aged 6-15 years old and 15 age-matched controls. Accuracy and precision of the foot-worn device were measured using an optical motion capture system as the reference system. Mean accuracy±precision for both groups was 3.4±4.6cm for stride length, 4.3±4.2cm/s for speed and 0.5±2.9° for strike angle. Longer stance and shorter swing phases with an increase in double support were observed in children with CP (p=0.001). Stride length, speed and peak angular velocity during swing were decreased in paretic limbs, with significant differences in strike and lift-off angles. Children with cerebral palsy showed significantly higher inter-stride variability (measured by their coefficient of variation) for speed, stride length, swing and stance. During turning trajectories speed and stride length decreased significantly (p<0.01) for both groups, whereas stance increased significantly (p<0.01) in CP children only. Foot-worn inertial sensors allowed us to analyze gait spatiotemporal data outside a laboratory environment with good accuracy and precision and congruent results with what is known of gait variations during linear walking in children with CP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pharmacists, mainly militiamen, are incorporated in the Swiss Armed Forces, for instance in hospital battalions to supply drugs and medical devices, as well as to coordinate hygiene service. Presently, their duties are only very globally defined. Aims: The objective of this survey was to investigate the tasks that were actually assumed by the military pharmacy of the 2nd Hospital Battalion. Methods: Two types of commitments, offering military and civilian interest's convergence, were considered between 2005 and 2011: (1) army camps for the disabled and (2) operations and supports provided to two nursing homes. While relieving the civil caregiver usually involved with disabled or elderly people, such missions offer indeed the possibility to the army medical service to train its care and logistical processes with real patients, even in the absence of any sanitary crisis or war in the country. Results: Two basis activities have been assumed: (1) centralized supply of drugs and medical devices and (2) coordination of hygiene monitoring and disinfection operations. New tasks were also performed: (3) support to the management of ward-based pharmacies, (4) pillboxes preparation, (5) medication review and (6) selective participation in clinical rounds. The last two were integrated in an interdisciplinary education process. Conclusions: Results shows that, apart from traditional duties, new clinical-oriented activities have been evenly developed and assumed by militia pharmacists. They call thus for a possible renewed definition of the tasks of military hospital pharmacists and of their related military education. A wider study in all hospital battalions is yet mandatory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0 degrees to 150 degrees of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90 degrees of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Dynamics is a central aspect of ski jumping, particularly during take-off and stable flight. Currently, measurement systems able to measure ski jumping dynamics (e.g. 3D cameras, force plates) are complex and only available in few research centres worldwide. This study proposes a method to determine dynamics using a wearable inertial sensor-based system which can be used routinely on any ski jumping hill. The system automatically calculates characteristic dynamic parameters during take-off (position and velocity of the centre of mass perpendicular to the table, force acting on the centre of mass perpendicular to the table and somersault angular velocity) and stable flight (total aerodynamic force). Furthermore, the acceleration of the ski perpendicular to the table was quantified to characterise the skis lift at take-off. The system was tested with two groups of 11 athletes with different jump distances. The force acting on the centre of mass, acceleration of the ski perpendicular to the table, somersault angular velocity and total aerodynamic force were different between groups and correlated with the jump distances. Furthermore, all dynamic parameters were within the range of prior studies based on stationary measurement systems, except for the centre of mass mean force which was slightly lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Front crawl is an alternating swimming stroke technique in which different phases of arm movement induce changes in acceleration of limbs and body. This study proposes a new approach to use inertial body worn sensors to estimate main temporal phases of front crawl. Distinctive features in kinematic signals are used to detect the temporal phases. These temporal phases are key information sources of qualitative and quantitative evaluation of swimming coordination, which have been assessed previously by video analysis. The present method has been evaluated upon a wide range of coordination and showed a difference of 4.9% with video based system. The results are in line with video analysis inter-operator variability yet offering an easy-to-use system for trainers.