9 resultados para Imaging techniques

em Université de Lausanne, Switzerland


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Neural stem cells have been proposed as a new and promising treatment modality in various pathologies of the central nervous system, including malignant brain tumors. However, the underlying mechanism by which neural stem cells target tumor areas remains elusive. Monitoring of these cells is currently done by use of various modes of molecular imaging, such as optical imaging, magnetic resonance imaging and positron emission tomography, which is a novel technology for visualizing metabolism and signal transduction to gene expression. In this new context, the microenvironment of (malignant) brain tumors and the blood-brain barrier gains increased interest. The authors of this review give a unique overview of the current molecular-imaging techniques used in different therapeutic experimental brain tumor models in relation to neural stem cells. Such methods for molecular imaging of gene-engineered neural stem/progenitor cells are currently used to trace the location and temporal level of expression of therapeutic and endogenous genes in malignant brain tumors, closing the gap between in vitro and in vivo integrative biology of disease in neural stem cell transplantation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The application of contrast media in post-mortem radiology differs from clinical approaches in living patients. Post-mortem changes in the vascular system and the absence of blood flow lead to specific problems that have to be considered for the performance of post-mortem angiography. In addition, interpreting the images is challenging due to technique-related and post-mortem artefacts that have to be known and that are specific for each applied technique. Although the idea of injecting contrast media is old, classic methods are not simply transferable to modern radiological techniques in forensic medicine, as they are mostly dedicated to single-organ studies or applicable only shortly after death. With the introduction of modern imaging techniques, such as post-mortem computed tomography (PMCT) and post-mortem magnetic resonance (PMMR), to forensic death investigations, intensive research started to explore their advantages and limitations compared to conventional autopsy. PMCT has already become a routine investigation in several centres, and different techniques have been developed to better visualise the vascular system and organ parenchyma in PMCT. In contrast, the use of PMMR is still limited due to practical issues, and research is now starting in the field of PMMR angiography. This article gives an overview of the problems in post-mortem contrast media application, the various classic and modern techniques, and the issues to consider by using different media.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Non-invasive brain imaging techniques often contrast experimental conditions across a cohort of participants, obfuscating distinctions in individual performance and brain mechanisms that are better characterised by the inter-trial variability. To overcome such limitations, we developed topographic analysis methods for single-trial EEG data [1]. So far this was typically based on time-frequency analysis of single-electrode data or single independent components. The method's efficacy is demonstrated for event-related responses to environmental sounds, hitherto studied at an average event-related potential (ERP) level. Methods: Nine healthy subjects participated to the experiment. Auditory meaningful sounds of common objects were used for a target detection task [2]. On each block, subjects were asked to discriminate target sounds, which were living or man-made auditory objects. Continuous 64-channel EEG was acquired during the task. Two datasets were considered for each subject including single-trial of the two conditions, living and man-made. The analysis comprised two steps. In the first part, a mixture of Gaussians analysis [3] provided representative topographies for each subject. In the second step, conditional probabilities for each Gaussian provided statistical inference on the structure of these topographies across trials, time, and experimental conditions. Similar analysis was conducted at group-level. Results: Results show that the occurrence of each map is structured in time and consistent across trials both at the single-subject and at group level. Conducting separate analyses of ERPs at single-subject and group levels, we could quantify the consistency of identified topographies and their time course of activation within and across participants as well as experimental conditions. A general agreement was found with previous analysis at average ERP level. Conclusions: This novel approach to single-trial analysis promises to have impact on several domains. In clinical research, it gives the possibility to statistically evaluate single-subject data, an essential tool for analysing patients with specific deficits and impairments and their deviation from normative standards. In cognitive neuroscience, it provides a novel tool for understanding behaviour and brain activity interdependencies at both single-subject and at group levels. In basic neurophysiology, it provides a new representation of ERPs and promises to cast light on the mechanisms of its generation and inter-individual variability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Three-dimensional segmented echo planar imaging (3D-EPI) is a promising approach for high-resolution functional magnetic resonance imaging, as it provides an increased signal-to-noise ratio (SNR) at similar temporal resolution to traditional multislice 2D-EPI readouts. Recently, the 3D-EPI technique has become more frequently used and it is important to better understand its implications for fMRI. In this study, the temporal SNR characteristics of 3D-EPI with varying numbers of segments are studied. It is shown that, in humans, the temporal variance increases with the number of segments used to form the EPI acquisition and that for segmented acquisitions, the maximum available temporal SNR is reduced compared to single shot acquisitions. This reduction with increased segmentation is not found in phantom data and thus likely due to physiological processes. When operating in the thermal noise dominated regime, fMRI experiments with a motor task revealed that the 3D variant outperforms the 2D-EPI in terms of temporal SNR and sensitivity to detect activated brain regions. Thus, the theoretical SNR advantage of a segmented 3D-EPI sequence for fMRI only exists in a low SNR situation. However, other advantages of 3D-EPI, such as the application of parallel imaging techniques in two dimensions and the low specific absorption rate requirements, may encourage the use of the 3D-EPI sequence for fMRI in situations with higher SNR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

While the overall incidence of myocardial infarction (MI) has been decreasing since 2000 [1], there is an increasing number of younger patients presenting with MI [2]. Few studies have focused on MI in very young patients, aged 35 years or less, as they only account for a minority of all patients with myocardial infarction [3]. According to the age category, MI differs in presentation, treatment and outcome, as illustrated in table 1. Echocardiography is considered mandatory according to scientific guidelines in the management and diagnosis of MI [4,5,6]. However, new imaging techniques such as cardiac magnetic resonance (CMR) and computed tomography (CT) are increasingly performed and enable further refinement of the diagnosis of MI. These techniques allow, in particular, precise location and quantification of MI. In this case, MI was located to the septum, which is an unusual presentation of MI. The incidence of pulmonary embolism (PE) has also increased in young patients over the past years [7]. Since symptoms and signs of PE may be non-specific, establishing its diagnosis remains a challenge [8]. Therefore, PE is one of the most frequently missed diagnosis in clinical medicine. Because of the widespread use of CT and its improved visualization of pulmonary arteries, PE may be discovered incidentally [9]. In the absence of a congenital disorder, multiple and/or simultaneous disease presentation is uncommon in the young. We report the rare case of a 35 year old male with isolated septal MI and simultaneous PE. The diagnosis of this rare clinical entity was only possible by means of newer imaging techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT: q-Space-based techniques such as diffusion spectrum imaging, q-ball imaging, and their variations have been used extensively in research for their desired capability to delineate complex neuronal architectures such as multiple fiber crossings in each of the image voxels. The purpose of this article was to provide an introduction to the q-space formalism and the principles of basic q-space techniques together with the discussion on the advantages as well as challenges in translating these techniques into the clinical environment. A review of the currently used q-space-based protocols in clinical research is also provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To assess the differences across continental regions in terms of stroke imaging obtained for making acute revascularization therapy decisions, and to identify obstacles to participating in randomized trials involving multimodal imaging. METHODS: STroke Imaging Repository (STIR) and Virtual International Stroke Trials Archive (VISTA)-Imaging circulated an online survey through its website, through the websites of national professional societies from multiple countries as well as through email distribution lists from STIR and the above mentioned societies. RESULTS: We received responses from 223 centers (2 from Africa, 38 from Asia, 10 from Australia, 101 from Europe, 4 from Middle East, 55 from North America, 13 from South America). In combination, the sites surveyed administered acute revascularization therapy to a total of 25,326 acute stroke patients in 2012. Seventy-three percent of these patients received intravenous (i.v.) tissue plasminogen activator (tPA), and 27%, endovascular therapy. Vascular imaging was routinely obtained in 79% (152/193) of sites for endovascular therapy decisions, and also as part of standard IV tPA treatment decisions at 46% (92/198) of sites. Modality, availability and use of acute vascular and perfusion imaging before revascularization varied substantially between geographical areas. The main obstacles to participate in randomized trials involving multimodal imaging included: mainly insufficient research support and staff (50%, 79/158) and infrequent use of multimodal imaging (27%, 43/158) . CONCLUSION: There were significant variations among sites and geographical areas in terms of stroke imaging work-up used tomake decisions both for intravenous and endovascular revascularization. Clinical trials using advanced imaging as a selection tool for acute revascularization therapy should address the need for additional resources and technical support, and take into consideration the lack of routine use of such techniques in trial planning.