55 resultados para ISO 9000

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the first results of the INTERNORM pilot project funded by the University of Lausanne (2010 - 2014) to support the involvement of civil society organisations (CSO) in two ISO technical committees (TC), the ISO TC 228 on "tourism and related services" and the ISO TC 229 on "nanotechnologies". It analyses how a distinct participatory mechanism can influence the institutional environment of technical diplomacy in which standards are shaped. The project is an attempt to respond to the democratic deficit attested in the field of international standardisation, formally open to civil society participation, but still largely dominated by expert knowledge and market players. Many international standards have direct implications on society as a whole, but CSOs (consumers and environmental associations, trade unions) are largely under-represented in negotiation arenas. The paper draws upon international relations literature on new institutional forms in global governance and studies of participation in science and technology to address three questions: to which extent do CSOs identify participation in standardisation as worth of their mobilisation? How is the pluralisation of knowledge and expertise supporting CSO position during the deliberation? To which extent can CSO access and influence standardisation beyond their consultative role? It argues that there are significant limitations to the rise of civil society participation in such global governance mechanisms. Despite high entry costs into technical diplomacy, participation is not so much a matter of upstream engagement, or of procedure and resources only, than of opportunistic CSOs mobilization, of distinct thematic incentives and concrete outcomes to be expected in standardisation arenas or in the broader use of international standards.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Potential risks of a secondary formation of polychlorinated dibenzodioxins/furans (PCDD/Fs) were assessed for two cordierite-based, wall-through diesel particulate filters (DPFs) for which soot combustion was either catalyzed with an iron- or a copper-based fuel additive. A heavy duty diesel engine was used as test platform, applying the eight-stage ISO 8178/4 C1 cycle. DPF applications neither affected the engine performance, nor did they increase NO, NO2, CO, and CO2 emissions. The latter is a metric for fuel consumption. THC emissions decreased by about 40% when deploying DPFs. PCDD/F emissions, with a focus on tetra- to octachlorinated congeners, were compared under standard and worst case conditions (enhanced chlorine uptake). The iron-catalyzed DPF neither increased PCDD/F emissions, nor did it change the congener pattern, even when traces of chlorine became available. In case of copper, PCDD/F emissions increased by up to 3 orders of magnitude from 22 to 200 to 12 700 pg I-TEQ/L with fuels of < 2, 14, and 110 microg/g chlorine, respectively. Mainly lower chlorinated DD/Fs were formed. Based on these substantial effects on PCDD/F emissions, the copper-catalyzed DPF system was not approved for workplace applications, whereas the iron system fulfilled all the specifications of the Swiss procedures for DPF approval (VERT).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cette thèse explore les implications politiques de la montée en puissance des normes internationales sur nos sociétés contemporaines et pose la problématique des dynamiques participatives des représentants des consommateurs au sein des formes de pouvoir non étatique à l'aide du cas de l'Organisation internationale de normalisation (ISO). Le renforcement du pouvoir des normes internationales et autres spécifications techniques soulève d'importants enjeux démocratiques qui portent aussi bien sur la représentativité des acteurs qui les élaborent, sur l'articulation des prérogatives publiques et privées dans la gouvernance de la mondialisation, que sur le rôle de l'expertise dans la reconnaissance de ces nouvelles formes de pouvoir. La participation du monde associatif intervient sur ces différents enjeux de manière complexe. Cette recherche s'inscrit à la suite des études en relations internationales/économie politique internationale sur les formes d'autorité non étatique et s'inspire du concept de traduction issu de la sociologie des sciences et techniques pour mettre en lumière le rôle des spécifications techniques dans la construction d'une société de consommation centrée sur la liberté de choix et la façon dont les associations de consommateurs se saisissent des arènes de normalisation pour y faire valoir des préoccupations collectives, leur expertise et leur identité. Cette thèse défend l'idée que les consommateurs participent à la construction de l'autorité des normes internationales par leur rôle dans la traduction qui permet de relier les spécifications techniques au fonctionnement des marchés, au cadre réglementaire de la loi et aux préoccupations sociétales. L'analyse repose sur une observation ethnographique des délibérations d'un comité technique de l'ISO, une recherche-­‐action, la réalisation d'entretiens et la consultation de documents d'archives de l'ISO. -- This thesis explores the political significance of the rise of international standards on contemporary societies and questions the participatory dynamics of consumers' representatives within nonstate forms of power, using the case of the International organization for standardization (ISO). The power granted to international standards and other technical specifications raises important democratic issues regarding the representativity of standard-­‐ writers, the public-­‐private relationships involved in this form of governance or the expertise sustaining the recognition of such new forms of power. The participation of civil society associations affect such issues in complex ways. This research relies on international relations/international political economy approaches of nonstate authority and takes inspiration from the concept of translation developed by science and technology studies to highlight the crucial role played by technical specifications in building a consumer society based on the freedom of choice as well as how consumers' associations take stock of standardization arenas to promote collective issues and claim their expertise and identity. This thesis argues that consumers contribute to the construction of the authority of international standards through their role in the translation that links international standards to the market society, the regulatory state as well as to societal preoccupation. The analysis is based on an ethnographic observation of deliberations within an ISO technical committee, a research-­‐action, interviews as well as on the consultation of ISO archives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyzed the coherence of electroencephalographic (EEG) signals recorded symmetrically from the two hemispheres, while subjects (n = 9) were viewing visual stimuli. Considering the many common features of the callosal connectivity in mammals, we expected that, as in our animal studies, interhemispheric coherence (ICoh) would increase only with bilateral iso-oriented gratings located close to the vertical meridian of the visual field, or extending across it. Indeed, a single grating that extended across the vertical meridian significantly increased the EEG ICoh in normal adult subjects. These ICoh responses were obtained from occipital and parietal derivations and were restricted to the gamma frequency band. They were detectable with different EEG references and were robust across and within subjects. Other unilateral and bilateral stimuli, including identical gratings that were effective in anesthetized animals, did not affect ICoh in humans. This fact suggests the existence of regulatory influences, possibly of a top-down kind, on the pattern of callosal activation in conscious human subjects. In addition to establishing the validity of EEG coherence analysis for assaying cortico-cortical connectivity, this study extends to the human brain the finding that visual stimuli cause interhemispheric synchronization, particularly in frequencies of the gamma band. It also indicates that the synchronization is carried out by cortico-cortical connection and suggests similarities in the organization of visual callosal connections in animals and in man.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Lesion detection in multiple sclerosis (MS) is an essential part of its clinical diagnosis. In addition, radiological characterisation of MS lesions is an important research field that aims at distinguishing different MS types, monitoring drug response and prognosis. To date, various MR protocols have been proposed to obtain optimal lesion contrast for early and comprehensive diagnosis of the MS disease. In this study, we compare the sensitivity of five different MR contrasts for lesion detection: (i) the DIR sequence (Double Inversion Recovery, [4]), (ii) the Dark-fluid SPACE acquisition schemes, a 3D variant of a 2D FLAIR sequence [1], (iii) the MP2RAGE [2], an MP-RAGE variant that provides homogeneous T1 contrast and quantitative T1-values, and the sequences currently used for clinical MS diagnosis (2D FLAIR, MP-RAGE). Furthermore, we investigate the T1 relaxation times of cortical and sub-cortical regions in the brain hemispheres and the cerebellum at 3T. Methods 10 early-stage female MS patients (age: 31.64.7y; disease duration: 3.81.9y; disability score, EDSS: 1.80.4) and 10 healthy controls (age and gender-matched: 31.25.8y) were included in the study after obtaining informed written consent according to the local ethic protocol. All experiments were performed at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil [5]. The imaging protocol included the following sequences, (all except for axial FLAIR 2D with 1x1x1.2 mm3 voxel and 256x256x160 matrix): DIR (TI1/TI2/TR XX/3652/10000 ms, iPAT=2, TA 12:02 min), MP-RAGE (TI/TR 900/2300 ms, iPAT=3, TA 3:47 min); MP2RAGE (TI1/TI2/TR 700/2500/5000 ms, iPAT=3, TA 8:22 min, cf. [2]); 3D FLAIR SPACE (only for patient 4-6, TI/TR 1800/5000 ms, iPAT=2, TA=5;52 min, cf. [1]); Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix, TI/TR 2500/9000 ms, iPAT=2, TA 4:05 min). Lesions were identified by two experienced neurologist and radiologist, manually contoured and assigned to regional locations (s. table 1). Regional lesion masks (RLM) from each contrast were compared for number and volumes of lesions. In addition, RLM were merged in a single "master" mask, which represented the sum of the lesions of all contrasts. T1 values were derived for each location from this mask for patients 5-10 (3D FLAIR contrast was missing for patient 1-4). Results & Discussion The DIR sequence appears the most sensitive for total lesions count, followed by the MP2RAGE (table 1). The 3D FLAIR SPACE sequence turns out to be more sensitive than the 2D FLAIR, presumably due to reduced partial volume effects. Looking for sub-cortical hemispheric lesions, the DIR contrast appears to be equally sensitive to the MP2RAGE and SPACE, but most sensitive for cerebellar MS plaques. The DIR sequence is also the one that reveals cortical hemispheric lesions best. T1 relaxation times at 3T in the WM and GM of the hemispheres and the cerebellum, as obtained with the MP2RAGE sequence, are shown in table 2. Extending previous studies, we confirm overall longer T1-values in lesion tissue and higher standard deviations compared to the non-lesion tissue and control tissue in healthy controls. We hypothesize a biological (different degree of axonal loss and demyelination) rather than technical origin. Conclusion In this study, we applied 5 MR contrasts including two novel sequences to investigate the contrast of highest sensitivity for early MS diagnosis. In addition, we characterized for the first time the T1 relaxation time in cortical and sub-cortical regions of the hemispheres and the cerebellum. Results are in agreement with previous publications and meaningful biological interpretation of the data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This book examines the role of technical standards in the regulation of services at the international level. It brings together scholarship in international political economy, French regulation theory, and economic sociology in order to discuss the following questions: Which services are most likely to be internationalised and what actors are the most concerned by the phenomenon? What is the relationship between the internationalisation of services and their institutional environment? What is more particularly the role of technical standards in delivering and using services? The introductory chapter presents a comprehensive analysis of cutting edge research on these questions. It argues that technical standards shape new forms of collective action and transnational authority. The chapter suggests some hypotheses for a new research agenda.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

International standardisation refers to voluntary technical specifications pertaining to the production and exchange of goods and services across borders. The paper outlines a theoretical framework which spells out the contention of emerging hybrid forms of non state authority in the global realm. It argues that international standardisation is confronted with a deep rift between promoters of further socialisation of international standards (i.e. a transfer of the universal scope of law into the official framework of standard-setting bodies) and multinational corporations in favour of globalisation of technical standards (i.e. universal recognition of minimal sectorial market-based standards). The problems related to the development of a possible ISO standard of system management in corporate social responsibility provides evidence of the argument.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The 1st International Symposium on Ostracoda (ISO) was held in Naples (1963). The philosophy behind this symposium and the logical outcome of what is now known as the International Research Group on Ostracoda (IRGO) is here reviewed, namely ostracodology over the last 50 years is sociologically analysed. Three different and important historic moments for the scientific achievements of this domain are recognised. The first one, between about 1963-1983, is related to applied research for the oil industry as well as to the great interest in the better description of the marine environment by both zoologists and palaeontologists. Another important aspect during this period was the work by researchers dealing with Palaeozoic ostracods, who had their own discussion group, IRGPO. Gradually, the merger of this latter group with those dealing with post-Palaeozoic ostracods at various meetings improved communication between the two groups of specialists. A second period was approximately delineated between 1983 and 2003. During this time-slice, more emphasis was addressed to environmental research with topics such as the study of global events and long-term climate change. Ostracodologists profited also from the research "politics" within national and international programmes. Large international research teams emerged using new research methods. During the third period (2003-2013), communication and collaborative research reached a global dimension. Amongst the topics of research we cite the reconstruction of palaeoclimate using transfer functions, the building of large datasets of ostracod distributions for regional and intercontinental studies, and the implementation of actions that should lead to taxonomic harmonisation. Projects within which molecular biological techniques are routinely used, combined with sophisticated morphological information, expanded now in their importance. The documentation of the ostracod description improved through new techniques to visualise morphological details, which stimulated also communication between ostracodologists. Efforts of making available ostracod information through newsletters and electronic media are evoked.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To describe the clinical, histologic and genetic findings of corneal opacities in the trisomy 8 mosaic syndrome. Methods: 3 children aged 8 years (Patients A), 6 years (Patients B) and 1 month (Patients C) respectively, were referred with corneal opacities for ophthalmologic evaluation. The 2 older patients had been previously diagnosed with trisomy 8 mosaicism, while the third was diagnosed after the ocular examination. Automated lamellar keratoplasty (ALTK) was performed on the most amblyopic eye. Histopathologic analysis with immunohistochemical markers and cytogenetic studies by FISH using haploid probes for chromosome 8 and chromosome 16 (control) were performed on the excised corneal lesion. Results: All patients presented vascularized corneal opacities involving the superficial stroma, and amblyopia with a bilateral involvement in two of them (Patients A and B). Post-operative follow-up (range 6-20 months) was satisfactory, with the graft remaining clear and improved visual acuity, allowing iso-acuity and stereoscopy in the one month old child (Patients C). The clinically observed corneal opacities corresponded histopathologically to the replacement of the normal anterior corneal stroma by a choristomatous loose richly vascularized connective tissue containing mucopolysacharides. Bowman's membrane was absent. There were no adnexal structures. The overlaying epithelium expressed keratin 3 in all three cases. Keratin 19 was found in the suprabasal epithelial cells in one case but was absent in the other cases. There were no expression of keratin 7 and 1 as well as MUC5AC in the epithelial cells. FISH analysis from 100 interphase cells of the affected tissue and normal conjontival probe revealed normal diploid cells. Conclusions: In this series, the corneal opacities associated with trisomy 8 mosaic syndrome share a common clinical, histopathological and genetic features. ALTK should be considered at diagnosis to prevent amblyopia in these children.

Relevância:

10.00% 10.00%

Publicador: