7 resultados para IPO Failures

em Université de Lausanne, Switzerland


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Cone-beam computed tomography (CBCT) image-guided radiotherapy (IGRT) systems are widely used tools to verify and correct the target position before each fraction, allowing to maximize treatment accuracy and precision. In this study, we evaluate automatic three-dimensional intensity-based rigid registration (RR) methods for prostate setup correction using CBCT scans and study the impact of rectal distension on registration quality. METHODS: We retrospectively analyzed 115 CBCT scans of 10 prostate patients. CT-to-CBCT registration was performed using (a) global RR, (b) bony RR, or (c) bony RR refined by a local prostate RR using the CT clinical target volume (CTV) expanded with 1-to-20-mm varying margins. After propagation of the manual CT contours, automatic CBCT contours were generated. For evaluation, a radiation oncologist manually delineated the CTV on the CBCT scans. The propagated and manual CBCT contours were compared using the Dice similarity and a measure based on the bidirectional local distance (BLD). We also conducted a blind visual assessment of the quality of the propagated segmentations. Moreover, we automatically quantified rectal distension between the CT and CBCT scans without using the manual CBCT contours and we investigated its correlation with the registration failures. To improve the registration quality, the air in the rectum was replaced with soft tissue using a filter. The results with and without filtering were compared. RESULTS: The statistical analysis of the Dice coefficients and the BLD values resulted in highly significant differences (p<10(-6)) for the 5-mm and 8-mm local RRs vs the global, bony and 1-mm local RRs. The 8-mm local RR provided the best compromise between accuracy and robustness (Dice median of 0.814 and 97% of success with filtering the air in the rectum). We observed that all failures were due to high rectal distension. Moreover, the visual assessment confirmed the superiority of the 8-mm local RR over the bony RR. CONCLUSION: The most successful CT-to-CBCT RR method proved to be the 8-mm local RR. We have shown the correlation between its registration failures and rectal distension. Furthermore, we have provided a simple (easily applicable in routine) and automatic method to quantify rectal distension and to predict registration failure using only the manual CT contours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY DESIGN: Prospective, controlled, observational outcome study using clinical, radiographic, and patient/physician-based questionnaire data, with patient outcomes at 12 months follow-up. OBJECTIVE: To validate appropriateness criteria for low back surgery. SUMMARY OF BACKGROUND DATA: Most surgical treatment failures are attributed to poor patient selection, but no widely accepted consensus exists on detailed indications for appropriate surgery. METHODS: Appropriateness criteria for low back surgery have been developed by a multispecialty panel using the RAND appropriateness method. Based on panel criteria, a prospective study compared outcomes of patients appropriately and inappropriately treated at a single institution with 12 months follow-up assessment. Included were patients with low back pain and/or sciatica referred to the neurosurgical department. Information about symptoms, neurologic signs, the health-related quality of life (SF-36), disability status (Roland-Morris), and pain intensity (VAS) was assessed at baseline, at 6 months, and at 12 months follow-up. The appropriateness criteria were administered prospectively to each clinical situation and outside of the clinical setting, with the surgeon and patients blinded to the results of the panel decision. The patients were further stratified into 2 groups: appropriate treatment group (ATG) and inappropriate treatment group (ITG). RESULTS: Overall, 398 patients completed all forms at 12 months. Treatment was considered appropriate for 365 participants and inappropriate for 33 participants. The mean improvement in the SF-36 physical component score at 12 months was significantly higher in the ATG (mean: 12.3 points) than in the ITG (mean: 6.8 points) (P = 0.01), as well as the mean improvement in the SF-36 mental component score (ATG mean: 5.0 points; ITG mean: -0.5 points) (P = 0.02). Improvement was also significantly higher in the ATG for the mean VAS back pain (ATG mean: 2.3 points; ITG mean: 0.8 points; P = 0.02) and Roland-Morris disability score (ATG mean: 7.7 points; ITG mean: 4.2 points; P = 0.004). The ATG also had a higher improvement in mean VAS for sciatica (4.0 points) than the ITG (2.8 points), but the difference was not significant (P = 0.08). The SF-36 General Health score declined in both groups after 12 months, however, the decline was worse in the ITG (mean decline: 8.2 points) than in the ATG (mean decline: 1.2 points) (P = 0.04). Overall, in comparison to ITG patients, ATG patients had significantly higher improvement at 12 months, both statistically and clinically. CONCLUSION: In comparison to previously reported literature, our study is the first to assess the utility of appropriateness criteria for low back surgery at 1-year follow-up with multiple outcome dimensions. Our results confirm the hypothesis that application of appropriateness criteria can significantly improve patient outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The high density of slope failures in western Norway is due to the steep relief and to the concentration of various structures that followed protracted ductile and brittle tectonics. On the 72 investigated rock slope instabilities, 13 were developed in soft weathered mafic and phyllitic allochthons. Only the intrinsic weakness of such rocks increases the susceptibility to gravitational deformation. In contrast, the gravitational structures in the hard gneisses reactivate prominent ductile or/and brittle fabrics. At 30 rockslides along cataclinal slopes, weak mafic layers of foliation are reactivated as basal planes. Slope-parallel steep foliation forms back-cracks of unstable columns. Folds are specifically present in the Storfjord area, together with a clustering of potential slope failures. Folding increases the probability of having favourably orientated planes with respect to the gravitational forces and the slope. High water pressure is believed to seasonally build up along the shallow-dipping Caledonian detachments and may contribute to destabilization of the rock slope upwards. Regional cataclastic faults localized the gravitational structures at 45 sites. The volume of the slope instabilities tends to increase with the amount of reactivated prominent structures and the spacing of the latter controls the size of instabilities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Poorly controlled cardiovascular risk factors are common. Evaluating whether physicians respond appropriately to poor risk factor control in patients may better reflect quality of care than measuring proportions of patients whose conditions are controlled. OBJECTIVES: To evaluate therapy modifications in response to poor control of hypertension, dyslipidemia, or diabetes in a large clinical population. DESIGN: Retrospective cohort study within an 18-month period in 2002 to 2003. SETTING: Kaiser Permanente of Northern California. PATIENTS: 253,238 adult members with poor control of 1 or more of these conditions. MEASUREMENTS: The authors assessed the proportion of patients with poor control who experienced a change in pharmacotherapy within 6 months, and they defined "appropriate care" as a therapy modification or return to control without therapy modification within 6 months. RESULTS: A total of 64% of patients experienced modifications in therapy for poorly controlled systolic blood pressure, 71% for poorly controlled diastolic blood pressure, 56% for poorly controlled low-density lipoprotein cholesterol level, and 66% for poorly controlled hemoglobin A1c level. Most frequent modifications were increases in number of drug classes (from 70% to 84%) and increased dosage (from 15% to 40%). An additional 7% to 11% of those with poorly controlled blood pressure, but only 3% to 4% of those with elevated low-density lipoprotein cholesterol level or hemoglobin A1c level, returned to control without therapy modification. Patients with more than 1 of the 3 conditions, higher baseline values, and target organ damage were more likely to receive "appropriate care." LIMITATIONS: Patient preferences and suboptimal adherence to therapy were not measured and may explain some failures to act. CONCLUSIONS: As an additional measure of the quality of care, measuring therapy modifications in response to poor control in a large population is feasible. Many patients with poorly controlled hypertension, dyslipidemia, or diabetes had their therapy modified and, thus, seemed to receive clinically "appropriate care" with this new quality measure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adiponectin is an adipokine, present in the circulation in comparatively high concentrations and different molecular weight isoforms. For the first time, the distribution of these isoforms in serum and follicular fluid (FF) and their usefulness as biological markers for infertility investigations was studied. In vitro study. University based hospital. Fifty-four women undergoing intracytoplasmic sperm injection (ICSI). Oocytes were retrieved, fertilized in vitro using ICSI, and the resulting embryos transferred. Serum was collected immediately prior to oocyte retrieval. Adiponectin isoforms (high molecular weight (HMW), medium and low molecular weight) were determined in serum and FF. Total adiponectin and the different isoform levels were compared with leptin and ovarian steroid concentrations. Adiponectin isoforms in serum and FF. Adiponectin isoform distribution differed between serum and FF; the HMW fraction made up half of all adiponectin in the serum but only 23.3% in the FF. Total and HMW adiponectin in both serum and FF correlated negatively with the body mass index and the concentration of leptin. No correlations were observed for total adiponectin or its isoforms with estradiol, progesterone, anti-Mullerian hormone, inhibin B, or the total follicle stimulating hormone (FSH) dose administered during the ovarian stimulation phase. This study shows for the first time that adiponectin isoform distribution varies between the serum and FF compartments in gonadotropin stimulated patients. A trend towards higher HMW adiponectin serum levels in successful ICSI cycles compared to implantation failures was observed; studies with larger patient groups are required to confirm this observation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Skeletal Muscle Biopsy is a minor surgical procedure for the diagnosis of different neuromuscular pathological conditions and has recently gained popularity also in the research field of age-related muscular modifications and sarcopenia. Few studies focused on the application of mini-invasive muscular biopsy in both normal and pathological conditions. The aim of our study was to describe a mini invasive ultrasound-guided skeletal muscular biopsy technique in complete spinal cord injured (SCI) patients and healthy controls with a tri-axial end-cut needle. PATIENTS AND METHODS: Skeletal muscle biopsies were collected from 6 chronic SCI patients and 3 healthy controls vastus lateralis muscle with a tri-axial end cut needle (Biopince© - Angiotech). Muscle samples were stained for ATPase to determine fibers composition, moreover, gene expression of cyclooxygenase-1 (COX-1) and prostaglandin E2 receptor has been analyzed by Real Time RT-PCR. RESULTS: All the procedures were perfomed easily without failures and complications. Control tissue was macroscopically thicker than SCI one. Control specimen displayed an equal distribution of type I and type II fibers, while SCI sample displayed a prevalence of type II fibers SCI specimen displayed a significant reduction in COX-1 gene expression. This mini-invasive approach was easy, accurate and with low complication rate in performing skeletal muscle biopsy in both SCI patients and controls. CONCLUSIONS: This technique could be useful in conditions in which the overall quantity of specimen required is small like for molecular biology analysis. For histological diagnostic purposes and/or conditions in which the original tissue is already pathologically modified, this technique should be integrated with more invasive techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study design: A retrospective study of image guided cervical implant placement precision. Objective: To describe a simple and precise classification of cervical critical screw placement. Summary of Background Data: "Critical" screw placement is defined as implant insertion into a bone corridor which is surrounded circumferentially by neurovascular structures. While the use of image guidance has improved accuracy, there is currently no classification which provides sufficient precision to assess the navigation success of critical cervical screw placement. Methods: Based on postoperative clinical evaluation and CT imaging, the orthogonal view evaluation method (OVEM) is used to classify screw accuracy into grade I (no cortical breach), grade la (screw thread cortical breach), grade II (internal diameter cortical breach) and grade III (major cortical breach causing neural or vascular injury). Grades II and III are considered to be navigation failures, after accounting for bone corridor / screw mismatch (minimal diameter of targeted bone corridor being smaller than an outer screw diameter). Results: A total of 276 screws from 91 patients were classified into grade I (64.9%), grade la (18.1%), and grade II (17.0%). No grade III screw was observed. The overall rate of navigation failure was 13%. Multiple logistic regression indicated that navigational failure was significantly associated with the level of instrumentation and the navigation system used. Navigational failure was rare (1.6%) when the margin around the screw in the bone corridor was larger than 1.5 mm. Conclusions: OVEM evaluation appears to be a useful tool to assess the precision of critical screw placement in the cervical spine. The OVEM validity and reliability need to be addressed. Further correlation with clinical outcomes will be addressed in future studies.