354 resultados para INTRAOCULAR-PRESSURE FLUCTUATIONS
em Université de Lausanne, Switzerland
Resumo:
PURPOSE: To evaluate the effect of intraocular administration of nitric oxide (NO) donors in the rabbit eye on intraocular pressure (IOP), inflammation, and toxicity. METHODS: Intravitreal and intracameral injections of two NO donors, SIN-1 and SNAP, and SIN-1C and BSS were performed. Clinical examination, IOP measurements, protein evaluation in aqueous humor, and histologic analysis of the ocular globes were realized. Nitric oxide release was demonstrated by nitrite production in the aqueous humor and in the vitreous using the Griess reaction. RESULTS: The drastic decrease of IOP, observed after a single NO donor injection, was correlated directly with nitrite production and, thus, to NO release. Injection of inactive metabolite of SIN-1, SIN-1C, which is not able to release NO, did not modulate IOP. When administered in the aqueous humor or in the vitreous, NO did not diffuse from one segment of the eye to another. No inflammation or histologic damage was observed as a result of a single NO donor administration. CONCLUSIONS: Nitric oxide is implicated directly in the regulation of IOP and its acute, and massive release into the rabbit eye did not induce inflammation or other growth toxic effects on the ocular tissues.
Resumo:
Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.
Resumo:
Background: Phacoemulsification is known to induce postoperative intraocular pressure (IOP) reduction, the degree of which varies according to glaucoma subtype and race. The authors set out to investigate the effect of cataract surgery on IOP, in a Swiss Caucasian population, and identify ocular predictive factors. Patients and Methods: 234 consecutive cases of 188 patients undergoing phacoemulsification between January 2011 and December 2012 were retrospectively reviewed and data collected. Exclusion criteria included acute angle closure, malignant glaucoma and pre-existing or subsequent glaucoma surgery. Pre- and post-operative visual acuity, IOP, gonioscopic findings, glaucoma medications, and laser treatments were recorded for eligible eyes. All eyes received the same postoperative regimen. Using multivariate analysis the predictive power of preoperative IOP, iridocorneal angle width, axial length on IOP reduction following phacoemulsification at months 3, 6 and 12 postoperatively were assessed. Eyes with narrow angles were compared against those with open angles. Results: 172 eyes of 121 patients met the inclusion criteria; mean age was 70.3 years (SD ± 10.7 years), with 77 males. Preoperatively median IOP was 16 mmHg (range 9-32 mmHg), mean number of glaucoma medications was 1.2 (SD ± 1.1), median visual acuity was 0.28 LogMAR (range 0-2.3LogMar). At 3 months post-operatively mean IOP decreased to 14 mmHg (p < 0.01) and remained statistically significantly reduced until 12 months, mean number of glaucoma medications was reduced to 1.0 and mean Snellen visual acuity increased to 0.8. Multivariate analysis revealed that pre-operative IOP and iridocorneal angle width (at 3 months) were significant predictive indicators of IOP reduction. At 12 months, IOP reduction was similar between open and narrow angle groups and total IOP reduction was no longer statistically significant. No intraoperative complications were recorded. Conclusions: Intraocular pressure reduction following phacoemulsification was greatest during the very early post-operative period, particularly in narrow angle patients. By one year, angle size was no longer predictive of IOP lowering, however pre-operative IOP and number of anti-glaucoma medications remained correlated with total IOP reduction.
Resumo:
PURPOSE: To determine the mechanisms and treatment of ocular hypertension in patients with thyroid-associated orbitopathy and to differenciate it from glaucomatous damage. DESIGN: Three case reports. METHODS: Retrospective review of clinical findings, course, and treatment of the three patients. RESULTS: Elevated intraocular pressure in thyroid-associated orbitopathy observed in the three cases may involve different physiopathological abnormalities such as disturbances of venous circulation, compression by infiltrative muscles, and long corticosteroid use. In the first two cases, defects demonstrated in the perimetry are in consistent with glaucomatous damage. In the third case, visual field abnormalities may be compatible with a glaucomatous disease, but all defects resolved after therapy. Treatement was of the greatest difficulty for the three cases, associating antiglaucomatous medication, steroids, orbital radiotherapy, orbital decompression and extraocular muscle surgery. Intraocular pressure was controlled in all cases. CONCLUSIONS: Elevated intraocular pressure in thyroid-associated orbitopathy is distinguished from glaucomatous disease by its physiopathological mechanisms, clinical course, visual field defects, and treatment. The management of this hypertension is closely related to the treatment of dysthyroid orbitopathy.
Resumo:
AbstractPurpose: to evaluate the tolerability, comfort and precision of the signal transmission of an ocular Sensor used for 24-hour intraocular pressure fluctuation monitoring in humans.Patients and methods: In this uncontrolled open trial involving 10 healthy volunteers an 8.7 mm radius prototype ocular telemetry Sensor (SENSIMED Triggerfish®, Lausanne, Switzerland) and an orbital bandage containing a loop antenna were applied and connected to a portable recorder after full eye examination. Best corrected visual acuity and position, surface wetting ability and mobility of the Sensor were assessed after 5 and 30 minutes, 4, 12 and 24 hours. Subjective wearing comfort was scored and activities documented in a logbook. After Sensor removal a full eye examination was repeated and the recorded signal analyzed.Results: The comfort score was high and did not fluctuate significantly over time. The mobility of the Sensor was limited across follow-up visits and its surface wetting ability remained good. Best corrected visual acuity was significantly reduced during Sensor wear and immediately after its removal (from 1.07 before, to 0.85 after, P-value 0.008). Three subjects developed a mild, transient corneal abrasion. In all but one participant we obtained usable data of a telemetric signal recording with sufficient sensitivity to depict ocular pulsation.Conclusions: This 24-hour- trial has encouraging results on the tolerability and functionality of the ocular telemetric Sensor for intraocular pressure fluctuation monitoring. Further studies with different Sensor radii conducted on a larger study population are needed to improve comfort, precision and interpretation of the telemetric signal.
Resumo:
BACKGROUND: Intraocular gas bubbles expand as patients move up to higher altitude. This may cause an acute intraocular pressure (IOP) rise with associated vascular obstructions and visual loss. MATERIALS AND METHODS: Two pseudophakic patients underwent a pars plana vitrectomy and 23% SF6 gas tamponade for a pseudophakic retinal detachment. During the immediate post-operative phase, the patients travelled daily up to their domicile, which was situated approximately 600 m higher than the level where they had been operated on. These travels were always without any pain or visual loss. However 1 week after surgery both patients developed severe ocular pain, and one patient had complete temporary loss of vision after ascending to altitude levels, which had previously presented no problem. Both episodes occurred in parallel with a change in barometric pressure. RESULTS: Treatment with acetazolamide reduced the increased IOP to normal levels, and visual acuity recovered. CONCLUSIONS: Although the post-operative size of an intraocular gas bubble decreases progressively over time, problems with bubble expansion may still occur even at a late stage if meteorological factors, that may increase the bubble size, change.
Resumo:
The biocompatibility of a viscous, hydrophobic, bioerodible poly(ortho ester) (POE) intended for intraocular application was investigated. POE was evaluated as a blank carrier and as containing modulators of degradation. Each formulation was injected intracamerally and intravitreally in rabbit eyes, and clinical and histological examinations were performed postoperatively for 2 weeks. In the case of intracameral injections, polymer biocompatibility appeared to depend on the amount injected in the anterior chamber. When 50 microL was administered, the polymer degraded within 2 weeks, and clinical observations showed good biocompatibility of POE with no toxicity to the ocular tissues or increase in intraocular pressure. The injection of a larger volume, 100 microL, of POE, appeared inappropriate because of direct contact of polymeric material with the corneal endothelium, and triggered reversible edema and inflammation in the anterior chamber of the eye that regressed after a few days. After intravitreal administration, POE was well tolerated and no inflammatory reaction developed during the observation period. The polymer degraded slowly, appearing as a round whitish bubble in the vitreous cavity. The presence of modulators of degradation both improved POE biocompatibility and prolonged polymer lifetime in the eye. POE appears to be a promising biomaterial for clinical intraocular application.
Resumo:
PURPOSE: To describe methods and outcomes of excisional revision of a filtering bleb (bleb revision) using free conjunctival autologous graft either for bleb repair or for bleb reduction after trabeculectomy and deep sclerectomy with an implant. METHODS: Retrospective medical records were reviewed for a consecutive non-comparative case series comprising patients who underwent excisional revision of a filtering bleb between May 1998-January 2001. Excisional revision using free conjunctival autologous graft (bleb revision) was performed either for bleb repair, to treat early and late leaks and hypotony with maculopathy, or for bleb reduction, to improve ocular pain, discomfort, burning, foreign body sensation, tearing, and fluctuations of visual acuity. The revision consisted of bleb excision and free conjunctival autologous graft. The bleb histopathology was analyzed in patients who underwent bleb repair. RESULTS: Sixteen patients were included in the study, consisting of nine patients who had a trabeculectomy and seven patients who had a deep sclerectomy with an implant. Bleb revision was necessary in 14 patients due to leaking filtering bleb (bleb repair), and in 2 patients due to bleb dysesthesia (bleb reduction). After a follow-up of 15.1 +/- 8.4 months, the mean intraocular pressure (IOP) rose from 7.8 +/- 6.3 mm Hg to 14.3 +/- 6.5 mm Hg, and the visual acuity from 0.4 +/- 0.3 to 0.7 +/- 0.3, with a P value of 0.008 and 0.03, respectively. The complete success rate at 32 months, according to the Kaplan-Meier survival curve, was 38.3%, and the qualified success rate was 83.3%. Four patients (25%) required additional suturing for persistent bleb leak. To control IOP, antiglaucoma medical therapy was needed for six patients (37.5%) and repeated glaucoma surgery was needed for one patient. CONCLUSION: Free conjunctival autologous graft is a safe and successful procedure for bleb repair and bleb reduction. However, patients should be aware of the postoperative possibility of requiring medical or surgical intervention for IOP control after revision.
Resumo:
PURPOSE: To assess the role of vitreoretinal surgery in maximizing treatment outcome following complications after proton therapy for uveal melanoma and to evaluate its safety. METHODS: Retrospective chart study on 21 patients (2% of a total of 1,005 treated by proton therapy between January 2003 and August 2007) who had developed a complication requiring vitreoretinal surgery. Mean/median total follow-up after irradiation was 43/43 months (range, 12-70 months). RESULTS: Indications for surgery included vitreous hemorrhage (n = 13), epimacular membrane (n = 5), rhegmatogenous retinal detachment (n = 1), combined vitreous hemorrhage with total serous retinal detachment (n = 1), and vitritis (n = 1). Mean/median interval for vitreoretinal surgery after irradiation was 21/20 months (range, 4-45 months), and mean/median follow-up after pars plana vitrectomy was 22/23 months (range, 2-56 months). Pars plana vitrectomy was combined with retinal photocoagulation (n = 5), air/gas (n = 5), or silicone oil tamponade (n = 1). Mean Snellen visual acuity was 20/200 (0-20/40) before and 20/100 (0-20/25) after pars plana vitrectomy. A transient postoperative rise in intraocular pressure was measured in seven patients. Four patients developed phthisis bulbi. CONCLUSION: Vitreoretinal surgery was efficient in maximizing treatment outcome after proton therapy, as it allowed a better oncologic follow-up. Pars plana vitrectomy permitted panretinal photocoagulation to avoid neovascular glaucoma or retinal detachment repair. Macular surgery improved visual acuity, especially in anterior melanoma, whereas repeated surgery may increase the risk of enucleation.
Resumo:
BACKGROUND: The aim of this study was to evaluate the mid-term biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. METHODS: Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. IOP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. RESULTS: For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. CONCLUSIONS: The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
BACKGROUND AND OBJECTIVE: To compare the efficacy and longevity of nonpenetrating glaucoma surgery with and without the use of a nonabsorbable hydrophilic implant at the Oxford Eye Centre, Johannesburg, South Africa, and the Glaucoma Unit, Jules Gonin Ophthalmic Hospital, Lausanne, Switzerland. PATIENTS AND METHODS: In a nonrandomized, prospective study between March 1997 and December 2001, 48 eyes of 32 patients aged 18 to 86 years with primary open-angle glaucoma underwent nonpenetrating glaucoma surgery; 25 eyes with the implant and 23 eyes without it. Intraocular pressure (IOP) was recorded preoperatively and postoperatively at 1, 7, and 14 days, at 1, 3, and 6 months, and thereafter every 6 months. RESULTS: The mean preoperative IOP was 27.5 +/- 11.8 mm Hg (range, 20 to 64 mm Hg) in the implant group and 24.8 +/- 7.1 mm Hg (range, 16 to 38 mm Hg) in the control group. During the first 18 months of follow-up, both groups showed identical IOP progression and the mean IOP remained less than 14 mm Hg. After 2 years of follow-up, the IOP started to rise in the control group but remained stable in the implant group. After 30 months, the mean IOP was 12.4 +/- 2 mm Hg and the IOP decrease in percentage was 62% +/- 6% in the implant group (n = 13) versus 16.1 +/- 3 mm Hg and 34% +/- 13% in the control group (n = 15) (mean IOP, P = .0022; mean IOP decrease in percentage, P = .01). CONCLUSIONS: During the first 18 months, there was no difference in the outcomes between the two groups. After 2 years of follow-up, the mean IOP was lower and the IOP decrease in percentage was greater in the implant group compared with the control group.
Resumo:
INTRODUCTION: Melanoma of the iris and ciliary body may be associated with secondary glaucoma. Treatment with proton beam radiotherapy (PBRT) to the anterior segment can also elevate intraocular pressure (IOP), resulting in uncontrolled glaucoma, often requiring enucleation. This is the first prospective study of Baerveldt aqueous shunts in irradiated eyes with anterior uveal melanoma (AUM; affecting the iris or ciliary body). METHODS: Thirty-one eyes with uncontrolled IOP following anterior segment PBRT treatment for AUM were prospectively recruited to undergo Baerveldt shunt implantation. Postoperative examinations were performed on day 1; weeks 1, 3, 6, 9; months 3, 6, 9, 12 and annually thereafter. Surgical success was defined as IOP 21 mm Hg or less and 20% reduction from baseline. All complications were recorded. RESULTS: Mean follow-up was 15.7 months (SD ±8.3 months). Mean interval from irradiation to shunt implantation was 2.5 years. Mean preoperative IOP was 31.0 (±10.3) mm Hg; mean IOP at last visit was 15.0 (±5.0) mm Hg; mean pre-operative glaucoma medications were 3.3 (±1.3); postoperatively 0.7 (±1.3) glaucoma medications. Surgical success rate was 86% using glaucoma medications. Four eyes had minor postoperative complications, none of which were sight threatening. There were no local tumour recurrences or systemic metastases. There were no enucleations caused by ocular hypertension. CONCLUSIONS: Baerveldt shunts were effective in lowering IOP, with few complications, in eyes treated with total anterior segment irradiation for AUM.