51 resultados para INHALED FRUSEMIDE

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhaled therapies play a significant role in the management of cystic fibrosis patients. Mucolytic and airway-rehydrating agents improve mucociliary clearance and respiratory functional status. Nebulized antibiotherapy achieve high local concentration, while reducing systemic toxicity. Tolerance to inhaled treatments is good excepting frequent bronchoconstriction which can usually be prevented by prior administration of beta2-mimetics. The majority of treatments are only available in liquid formulations. Thus, nebulization is the most frequently used inhalation mode. Vibrating-mesh nebulizers have significantly reduced inhalation time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An assessment of sewage workers' exposure to airborne cultivable bacteria, fungi and inhaled endotoxins was performed at 11 sewage treatment plants. We sampled the enclosed and unenclosed treatment areas in each plant and evaluated the influence of seasons (summer and winter) on bioaerosol levels. We also measured personal exposure to endotoxins of workers during special operation where a higher risk of bioaerosol inhalation was assumed. Results show that only fungi are present in significantly higher concentrations in summer than in winter (2331 +/- 858 versus 329 +/- 95 CFU m(-3)). We also found that there are significantly more bacteria in the enclosed area, near the particle grids for incoming water, than in the unenclosed area near the aeration basins (9455 +/- 2661 versus 2435 +/- 985 CFU m(-3) in summer and 11 081 +/- 2299 versus 2002 +/- 839 CFU m(-3) in winter). All bioaerosols were frequently above the recommended values of occupational exposure. Workers carrying out special tasks such as cleaning tanks were exposed to very high levels of endotoxins (up to 500 EU m(-3)) compared to routine work. The species composition and concentration of airborne Gram-negative bacteria were also studied. A broad spectrum of different species within the Pseudomonadaceae and the Enterobacteriaceae families were predominant in nearly all plants investigated. [Authors]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the sensitivity of the perfusion parameters derived from Intravoxel Incoherent Motion (IVIM) MR imaging to hypercapnia-induced vasodilatation and hyperoxygenation-induced vasoconstriction in the human brain. Materials and Methods: This study was approved by the local ethics committee and informed consent was obtained from all participants. Images were acquired with a standard pulsed-gradient spin-echo sequence (Stejskal-Tanner) in a clinical 3-T system by using 16 b values ranging from 0 to 900 sec/mm(2). Seven healthy volunteers were examined while they inhaled four different gas mixtures known to modify brain perfusion (pure oxygen, ambient air, 5% CO(2) in ambient air, and 8% CO(2) in ambient air). Diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), and blood flow-related parameter (fD*) maps were calculated on the basis of the IVIM biexponential model, and the parametric maps were compared among the four different gas mixtures. Paired, one-tailed Student t tests were performed to assess for statistically significant differences. Results: Signal decay curves were biexponential in the brain parenchyma of all volunteers. When compared with inhaled ambient air, the IVIM perfusion parameters D*, f, and fD* increased as the concentration of inhaled CO(2) was increased (for the entire brain, P = .01 for f, D*, and fD* for CO(2) 5%; P = .02 for f, and P = .01 for D* and fD* for CO(2) 8%), and a trend toward a reduction was observed when participants inhaled pure oxygen (although P > .05). D remained globally stable. Conclusion: The IVIM perfusion parameters were reactive to hyperoxygenation-induced vasoconstriction and hypercapnia-induced vasodilatation. Accordingly, IVIM imaging was found to be a valid and promising method to quantify brain perfusion in humans. © RSNA, 2012.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adverse events in utero are associated with the occurrence of chronic diseases in adulthood. We previously demonstrated in mice that perinatal hypoxia resulted in altered pulmonary circulation in adulthood, with a decreased endothelium-dependent relaxation of pulmonary arteries, associated with long-term alterations in the nitric oxide (NO)/cyclic GMP pathway. The present study investigated whether inhaled NO (iNO) administered simultaneously to perinatal hypoxia could have potential beneficial effects on the adult pulmonary circulation. Indeed, iNO is the therapy of choice in humans presenting neonatal pulmonary hypertension. Long-term effects of neonatal iNO therapy on adult pulmonary circulation have not yet been investigated. Pregnant mice were placed in hypoxia (13% O2) with simultaneous administration of iNO 5 days before delivery until 5 days after birth. Pups were then raised in normoxia until adulthood. Perinatal iNO administration completely restored acetylcholine-induced relaxation, as well as endothelial nitric oxide synthase protein content, in isolated pulmonary arteries of adult mice born in hypoxia. Right ventricular hypertrophy observed in old mice born in hypoxia compared to controls was also prevented by perinatal iNO treatment. Therefore, simultaneous administration of iNO during perinatal hypoxic exposure seems able to prevent adverse effects of perinatal hypoxia on the adult pulmonary circulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We compared cerebral blood flow velocity during anesthesia with sevoflurane and halothane in 23 children admitted for elective surgery (age, 0.4-9.7 yr; median age, 1.9 yr; ASA physical status I-II). Inhaled induction was performed in a randomized sequence with sevoflurane or halothane. Under steady-state conditions, cerebral blood flow velocity (systolic [V(s)], mean [V(mn)], and diastolic [VD]) were measured by a blinded investigator using transcranial pulsed Doppler ultrasonography. The anesthetic was then changed. CBFV measurements were repeated after washout of the first anesthetic and after steady-state of the second (equivalent minimal alveolar concentration to first anesthetic). The resistance index was calculated. VD and V(mn) were significantly lower during sevoflurane (V(mn) 1.35 m/s) than during halothane (V(mn) 1.50 m/s; P = 0.001), whereas V(s) was unchanged. The resistance index was lower during halothane (P < 0.001). Our results indicate lower vessel resistance and higher mean velocity during halothane than during sevoflurane. IMPLICATIONS: The mean cerebral blood flow velocity is significantly decreased in children during inhaled anesthesia with sevoflurane than during halothane. This might be relevant for the choice of anesthetic in children with risk of increased intracranial pressure, neurosurgery, or craniofacial osteotomies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acute severe asthma is defined by the occurrence of an acute exacerbation resistant to the initial medical treatment, complicated by life-threatening respiratory distress due to severe lung hyperinflation. The conventional therapeutic approach is based on oxygen therapy and on the combined treatment of inhaled beta2-agonists at repeated doses and systemic corticosteroids. Inhaled or systemic magnesium sulfate is also recommended. The unresponsiveness to the initial bronchodilating therapy and the development of respiratory distress requiring intubation significantly increases mortality, due to the complications induced by mechanical ventilation. In these situations, a ventilatory strategy, including controlled hypoventilation with permissive hypercapnia, aiming at preventing lung hyperinflation, is indicated. Non-invasive ventilation may be successful in certain patients and represents an effective alternative to intubation. In ventilated patients, helium-oxygen mixtures can be considered as adjunctive therapies. After having reviewed the basic pathophysiological principles, this article will focus on the current medical treatment and of the modalities of mechanical ventilation in acute severe asthma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulmonary involvement in Fabry disease has received less attention than the effects of the disease on the kidneys, nervous system or heart. However, data from FOS -the Fabry Outcome Survey - are now helping to elucidate the pulmonary manifestations of Fabry disease. Twenty-three patients out of a cohort of 67 analysed in FOS have been identified with airway obstruction, as defined by a ratio of forced expiratory volume in 1 second to forced vital capacity of less than 0.7. This prevalence is much greater than would be expected in the general population, with the main risk factors appearing to be increasing age and male gender. Spirometric analysis has revealed that the airway obstruction is clinically much more similar to chronic obstructive pulmonary disease than to asthma. Although little is known about the anatomical changes responsible for airway obstruction in patients with Fabry disease, airway wall hyperplasia and/or fibrosis are potential causes. Treatment of patients with moderate or severe airway obstruction should include inhaled bronchodilators, and individuals who smoke should be encouraged to stop. Further studies and future analyses of FOS data should determine whether enzyme replacement therapy is able to help or prevent the pulmonary manifestations of Fabry disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Occupational risks, the present nuclear threat, and the potential danger associated with nuclear power have raised concerns regarding the metabolism of plutonium in pregnant women. OBJECTIVE: We measured plutonium levels in the milk teeth of children born between 1951 and 1995 to assess the potential risk that plutonium incorporated by pregnant women might pose to the radiosensitive tissues of the fetus through placenta transfer. METHODS: We used milk teeth, whose enamel is formed during pregnancy, to investigate the transfer of plutonium from the mother's blood plasma to the fetus. We measured plutonium using sensitive sector field inductively coupled plasma mass spectrometry techniques. We compared our results with those of a previous study on strontium-90 ((90)Sr) released into the atmosphere after nuclear bomb tests. RESULTS: Results show that plutonium activity peaks in the milk teeth of children born about 10 years before the highest recorded levels of plutonium fallout. By contrast, (90)Sr, which is known to cross the placenta barrier, manifests differently in milk teeth, in accordance with (90)Sr fallout deposition as a function of time. CONCLUSIONS: These findings demonstrate that plutonium found in milk teeth is caused by fallout that was inhaled around the time the milk teeth were shed and not from any accumulation during pregnancy through placenta transfer. Thus, plutonium may not represent a radiologic risk for the radiosensitive tissues of the fetus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Although endogenous nitric oxide (NO) is an excitatory mediator in the central nervous system, inhaled NO is not considered to cause neurologic side effects because of its short half-life. This study was motivated by a recent case report about neurologic symptoms and our own observation of severe electroencephalogram (EEG) abnormalities during NO inhalation. DESIGN: Blind, retrospective analyses of EEGs which were registered before, during, and after NO inhalation. EEG was classified in a 5-point rating system by an independent electroencephalographer who was blinded to the patients' clinical histories. Comparisons were made with the previous evaluation documented at recording. Other EEG-influencing parameters such as oxygen saturation, hemodynamics, electrolytes, and pH were evaluated. SETTING: Pediatric intensive care unit of a tertiary care university children's hospital. PATIENTS: Eleven ventilated, long-term paralyzed, sedated children (1 mo to 14 yrs) who had EEG or clinical assessment before NO treatment and EEG during NO inhalation. They were divided into two groups according to the NO-indication (e.g., congenital heart defect, acute respiratory distress syndrome). MEASUREMENTS AND MAIN RESULTS: All 11 patients had an abnormal EEG during NO inhalation. EEG-controls without NO showed remarkable improvement. EEG abnormalities were background slowing, low voltage, suppression burst (n = 2), and sharp waves (n = 2) independent of patients' age, NO-indication, and other EEG-influencing parameters. CONCLUSIONS: These preliminary data suggest the occurrence of EEG-abnormalities after application of inhaled NO in critically ill children. We found no correlation with other potential EEG-influencing parameters, although clinical state, medication, or hypoxemia might contribute. Comprehensive, prospective, clinical assessment regarding a causal relationship between NO-inhalation and EEG-abnormalities and their clinical importance is needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Given the significant impact the use of glucocorticoids can have on fracture risk independent of bone density, their use has been incorporated as one of the clinical risk factors for calculating the 10-year fracture risk in the World Health Organization's Fracture Risk Assessment Tool (FRAX(®)). Like the other clinical risk factors, the use of glucocorticoids is included as a dichotomous variable with use of steroids defined as past or present exposure of 3 months or more of use of a daily dose of 5 mg or more of prednisolone or equivalent. The purpose of this report is to give clinicians guidance on adjustments which should be made to the 10-year risk based on the dose, duration of use and mode of delivery of glucocorticoids preparations. A subcommittee of the International Society for Clinical Densitometry and International Osteoporosis Foundation joint Position Development Conference presented its findings to an expert panel and the following recommendations were selected. 1) There is a dose relationship between glucocorticoid use of greater than 3 months and fracture risk. The average dose exposure captured within FRAX(®) is likely to be a prednisone dose of 2.5-7.5 mg/day or its equivalent. Fracture probability is under-estimated when prednisone dose is greater than 7.5 mg/day and is over-estimated when the prednisone dose is less than 2.5 mg/day. 2) Frequent intermittent use of higher doses of glucocorticoids increases fracture risk. Because of the variability in dose and dosing schedule, quantification of this risk is not possible. 3) High dose inhaled glucocorticoids may be a risk factor for fracture. FRAX(®) may underestimate fracture probability in users of high dose inhaled glucocorticoids. 4) Appropriate glucocorticoid replacement in individuals with adrenal insufficiency has not been found to increase fracture risk. In such patients, use of glucocorticoids should not be included in FRAX(®) calculations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To evaluate outcome of patients treated "off-label" by bosentan and/or sildenafil for chronic thromboembolic pulmonary hypertension (CTEPH). Patients and methods: Since 2003, 18 patients (mean age 69 ± 11 years) have been treated with bosentan and/or sildenafil for CTEPH (mean pulmonary arterial resistance 8.1 ± 3.7 U Wood) in Lausanne University Hospital, with a follow-up of at least 12 months. Sixteen of them were inoperable because of distal disease and/or age or significant co-morbidities and 2 had persistent or recurrent pulmonary hypertension despite surgery. Efficacy of treatment was evaluated by comparison of New York Heart Association functional class (NYHA), six-minute walk test (6-MWT) and serum levels of N-terminal-pro brain natriuretic peptide (NT pro-BNP) at baseline (T0) and at 12 months (T12). Wilcoxon rank test was used for statistics. Results: At T0, median NYHA class was III (range II-IV), 6-MWT was 348 meters (5 and 95 centiles:0, 539) and NT pro-BNP was 387 mmol/l (58, 3508). At T12, 11 patients were treated with bosentan, 5 with sildenafil, 1 with inhaled Iloprost (because of failure of the two other treatments) and 1 with a combination of sildenafil and Iloprost. NYHA had improved in 10 patients, remained stable in 7 and worsened in 1 (median decrease 0.5 (-2; 0.2) p = 0.013). Six-MWT improved by a median of 15 meters (-142, +270) (p = 0.047) and NT pro-BNP decreased by a median of 65 mmol/l (-2988, +187) (p = n.s.). Among the 10 patients with a follow-up of 2 years or longer, two thirds remained stable and one third had worsened at 24 month. Treatments were well tolerated and only one patient had significant side effects (cutaneous reaction to bosentan) necessitating a switch to another treatment. Conclusion: In agreement with published data, bosentan and sildenafil improved functional status (NYHA, 6-MWT) and haemodynamics (NT pro BNP) in our patients with inoperable CTEPH. However these medications should not be used as substitute for surgery when the latter is applicable.