6 resultados para IMMEDIATE DENTAL IMPLANT LOADING

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: This systematic review aims to assess the risks (both thromboembolic and bleeding) of an oral anticoagulation therapy (OAT) patient undergoing implant therapy and to provide a management protocol to patients under OAT undergoing implant therapy. MATERIAL AND METHODS: Medline, Cochrane Data Base of Systematic Reviews, the Cochrane Central Register of Controlled Trials and EMBASE (from 1980 to December 2008) were searched for English-language articles published between 1966 and 2008. This search was completed by a hand research accessing the references cited in all identified publications. RESULTS: Nineteen studies were identified reporting outcomes after oral surgery procedures (mostly dental extractions in patients on OAT following different management protocols and haemostatic therapies). Five studies were randomized-controlled trials (RCTs), 11 were controlled clinical trials (CCTs) and three were prospective case series. The OAT management strategies as well as the protocols during and after surgery were different. This heterogeneity prevented any possible data aggregation and synthesis. The results from these studies are very homogeneous, reporting minor bleeding in very few patients, without a significant difference between the OAT patients who continue with the vitamin K antagonists vs. the patients who stopped this medication before surgery. These post-operative bleeding events were controlled only with local haemostatic measures: tranexamic acid mouthwashes, gelatine sponges and cellulose gauzes's application were effective. Post-operative bleeding did not correlate with the international normalised ratio (INR) status. In none of the studies was a thromboembolic event reported. CONCLUSIONS: OAT patients (INR 2-4) who do not discontinue the AC medication do not have a significantly higher risk of post-operative bleeding than non-OAT patients and they also do not have a higher risk of post-operative bleeding than OAT patients who discontinue the medication. In patients with OAT (INR 2-4) without discontinuation, topical haemostatic agents were effective in preventing post-operative bleeding. OAT discontinuation is not recommended for minor oral surgery, such as single tooth extraction or implant placement, provided that this does not involve autogenous bone grafts, extensive flaps or osteotomy preparations extending outside the bony envelope. Evidence does not support that dental implant placement in patients on OAT is contraindicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To analyze available evidence on the incidence of anatomical variations or disease of the maxillary sinuses as identified by cone beam computed tomography (CBCT) in dentistry. MATERIALS AND METHODS: A focused question was developed to search the electronic databases MEDLINE, EMBASE, the Cochrane Oral Health Group Trials Register, and CENTRAL and identify all relevant papers published between 1980 and January 19, 2013. Unpublished literature at ClinicalTrials.gov, in the National Research Register, and in the Pro-Quest Dissertation Abstracts and Thesis database was also included. Studies were included irrespective of language. These results were supplemented by hand and gray literature searches. RESULTS: Twenty-two studies were identified. Twenty were retrospective cohort studies, one was a prospective cohort study, and one was a case control study. The main indication for CBCT was dental implant treatment planning, and the majority of studies used a small field of view for imaging. The most common anatomical variations included increased thickness of the sinus membrane, the presence of sinus septa, and pneumatization. Reported sinus disease frequency varied widely, ranging from 14.3% to 82%. There was a wide range in the reported prevalence of mucosal thickening related to apical pathology, the degree of lumenal opacification, features of sinusitis, and the presence of retention cysts and polyps. More pathologic findings in the maxillary sinus were reported in men than in women, and the medial wall and sinus floor were most frequently affected. CONCLUSION: CBCT is used primarily to evaluate bony anatomy and to screen for overt pathology of the maxillary sinuses prior to dental implant treatment. Differences in the classification of mucosal findings are problematic in the consistent and valid assessment of health and disease of the maxillary sinus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant.Material and Methods Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms.The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the microvements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion.Results 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present.Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns).Discussion Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established.Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this systematic review is to evaluate, analysing the dental literature, whether: * Patients on intravenous (IV) or oral bisphosphonates (BPs) can receive oral implant therapy and what could be the risk of developing bisphosphonate-related osteonecrosis of the jaw (BRONJ)? * Osseointegrated implants could be affected by BP therapy. MATERIAL AND METHODS: A Medline search was conducted and all publications fulfilling the inclusion and exclusion criteria from 1966 until December 2008 were included in the review. Moreover, the Cochrane Data Base of Systematic Reviews, and the Cochrane Central Register of Controlled Trials and EMBASE (from 1980 to December 2008) were searched for English-language articles published between 1966 and 2008. Literature search was completed by a hand research accessing the references cited in all identified publications. RESULTS: The literature search rendered only one prospective and three retrospective studies. The prospective controlled non-randomized clinical study followed patients with and without BP medication up to 36 months after implant therapy. The patients in the experimental group had been on oral BPs before implant therapy for periods ranging between 1 and 4 years. None of the patients developed BRONJ and implant outcome was not affected by the BP medication. The three selected retrospective studies (two case-controls and one case series) yielded very similar results. All have followed patients on oral BPs after implant therapy, with follow-up ranging between 2 and 4 years. BRONJ was never reported and implant survival rates ranged between 95% and 100%. The literature search on BRONJ including guidelines and recommendations found 59 papers, from which six were retrieved. Among the guidelines, there is a consensus on contraindicating implants in cancer patients under IV-BPs and not contraindicating dental implants in patients under oral-BPs for osteoporosis. CONCLUSIONS: From the analysis of the one prospective and the three retrospective series (217 patients), the placement of an implant may be considered a safe procedure in patients taking oral BPs for <5 years with regard to the occurrence of BRONJ since in these studies no BRONJ has been reported. Moreover, the intake of oral-BPs did not influence short-term (1-4 years) implant survival rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI). SETTING: Glaucoma Unit, Department of Ophthalmology, Hôpital Ophtalmique Jules Gonin, University of Lausanne, Lausanne, Switzerland. METHODS: This nonrandomized prospective trial comprised 105 eyes of 105 patients with medically uncontrolled primary and secondary open-angle glaucoma. Visual acuity, intraocular pressure (IOP), and slitlamp examinations were performed before surgery and after surgery at 1 and 7 days, and 1, 3, 6, 9, 12, 18, 24, 30, 36, 48, 54, 60, 66, 72, 78, 84, 90, and 96 months. Visual field examinations were repeated every 6 months. RESULTS: Mean follow-up period was 64 months +/- 26.6 (SD). Mean preoperative IOP was 26.8 +/- 7.7 mm Hg, and mean postoperative IOP was 5.2 +/- 3.35 mm Hg at day 1 and 12 +/- 3 mm Hg at month 78. At 96 months, the qualified success rate (ie, patients who achieved IOP <21 mm Hg with and without medication) was 91%, and the complete success rate (ie, IOP <21 mm Hg without medication) was 57%. At 96 months, 34% of patients had an IOP <21 mm Hg with medication. Fifty-one patients (49%) achieved an IOP < or =15 mm Hg without medication. Neodymium:YAG goniopuncture was performed in 54 patients (51%); mean time of goniopuncture performance was 21 months, and mean IOP before goniopuncture was 20 mm Hg, dropping to 11 mm Hg after goniopuncture. No shallow or flat anterior chamber, endophthalmitis, or surgery-induced cataract was observed. However, 26 patients (25%) showed a progression of preexisting senile cataract (mean time 26 months; range 18 to 37 months). Injections of 5-fluorouracil were administered to 25 patients (23%) who underwent DSCI to salvage encysted blebs. Mean number of medications per patient was reduced from 2.3 +/- 0.7 to 0.5 +/- 0.7 (signed rank P<.0001). CONCLUSION: Deep sclerectomy with collagen implant appears to provide stable and reasonable control of IOP at long-term follow-up with few immediate postoperative complications.