4 resultados para ICCS-tutkimus
em Université de Lausanne, Switzerland
Resumo:
Decline in gait stability has been associated with increased fall risk in older adults. Reliable and clinically feasible methods of gait instability assessment are needed. This study evaluated the relative and absolute reliability and concurrent validity of the testing procedure of the clinical version of the Narrow Path Walking Test (NPWT) under single task (ST) and dual task (DT) conditions. Thirty independent community-dwelling older adults (65-87 years) were tested twice. Participants were instructed to walk within the 6-m narrow path without stepping out. Trial time, number of steps, trial velocity, number of step errors, and number of cognitive task errors were determined. Intraclass correlation coefficients (ICCs) were calculated as indices of agreement, and a graphic approach called "mountain plot" was applied to help interpret the direction and magnitude of disagreements between testing procedures. Smallest detectable change and smallest real difference (SRD) were computed to determine clinically relevant improvement at group and individual levels, respectively. Concurrent validity was assessed using Performance Oriented Mobility Assessment Tool (POMA) and the Short Physical Performance Battery (SPPB). Test-retest agreement (ICC1,2) varied from 0.77 to 0.92 in ST and from 0.78 to 0.92 in DT conditions, with no apparent systematic differences between testing procedures demonstrated by the mountain plot graphs. Smallest detectable change and smallest real change were small for motor task performance and larger for cognitive errors. Significant correlations were observed for trial velocity and trial time with POMA and SPPB. The present results indicate that the NPWT testing procedure is highly reliable and reproducible.
Resumo:
ABSTRACT: BACKGROUND: Most scales that assess the presence and severity of psychotic symptoms often measure a broad range of experiences and behaviours, something that restricts the detailed measurement of specific symptoms such as delusions or hallucinations. The Psychotic Symptom Rating Scales (PSYRATS) is a clinical assessment tool that focuses on the detailed measurement of these core symptoms. The goal of this study was to examine the psychometric properties of the French version of the PSYRATS. METHODS: A sample of 103 outpatients suffering from schizophrenia or schizoaffective disorders and presenting persistent psychotic symptoms over the previous three months was assessed using the PSYRATS. Seventy-five sample participants were also assessed with the Positive And Negative Syndrome Scale (PANSS). RESULTS: ICCs were superior to .90 for all items of the PSYRATS. Factor analysis replicated the factorial structure of the original version of the delusions scale. Similar to previous replications, the factor structure of the hallucinations scale was partially replicated. Convergent validity indicated that some specific PSYRATS items do not correlate with the PANSS delusions or hallucinations. The distress items of the PSYRATS are negatively correlated with the grandiosity scale of the PANSS. CONCLUSIONS: The results of this study are limited by the relatively small sample size as well as the selection of participants with persistent symptoms. The French version of the PSYRATS partially replicates previously published results. Differences in factor structure of the hallucinations scale might be explained by greater variability of its elements. The future development of the scale should take into account the presence of grandiosity in order to better capture details of the psychotic experience.
Resumo:
The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.
Resumo:
PURPOSE: To examine the reproducibility of carotid artery dimension measurements using 3T MRI. MATERIALS AND METHODS: Ten healthy volunteers underwent three scans on two occasions for assessment of total vessel wall area (TVWA), total luminal area (TLA), and minimum (MinT) and maximum (MaxT) vessel wall thickness. A double inversion-recovery (IR) fast gradient-echo (FGRE) sequence was used on a commercial 3T system. During the first visit the subjects were scanned twice. The third scan was performed at least four days later. One observer traced all scans, and a second observer retraced the first scan series. RESULTS: For TVWA an interclass correlation (ICC) of 0.994 was calculated with all three scans taken into account. The interobserver ICC was 0.984. The agreement between the scans for TLA showed an ICC of 0.982 with an interobserver ICC of 0.998. For MinT and MaxT an ICC of 0.843 and 0.935 were calculated, with interobserver ICCs of 0.860 and 0.726, respectively. CONCLUSION: With the use of a commercial 3T MR system, TVWA, TLA, and wall thickness measurements of the carotid artery can be assessed with good reproducibility.