2 resultados para IABP

em Université de Lausanne, Switzerland


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND & AIMS: The study was designed to investigate and quantify nutritional support, and particularly enteral nutrition (EN), in critically ill patients with severe hemodynamic failure. METHODS: Prospective, descriptive study in a surgical intensive care unit (ICU) in a university teaching hospital: patients aged 67+/-13 yrs (mean+/-SD) admitted after cardiac surgery with extracorporeal circulation, staying 5 days in the ICU with acute cardiovascular failure. Severity of disease was assessed with SAPS II, and SOFA scores. Variables were energy delivery and balance, nutrition route, vasopressor doses, and infectious complications. Artificial feeding delivered according to ICU protocol. EN was considered from day 2-3. Energy target was set 25 kcal/kg/day to be reached stepwise over 5 days. RESULTS: Seventy out of 1114 consecutive patients were studied, aged 67+/-17 years, and staying 10+/-7 days in the ICU. Median SAPS II was 43. Nine patients died (13%). All patients had circulatory failure: 18 patients required intra-aortic balloon-pump support (IABP). Norepinephrine was required in 58 patients (83%). Forty patients required artificial nutrition. Energy delivery was very variable. There was no abdominal complication related to EN. As a mean, 1360+/-620 kcal/kg/day could be delivered enterally during the first 2 weeks, corresponding to 70+/-35% of energy target. Enteral nutrient delivery was negatively influenced by increasing dopamine and norepinephrine doses, but not by the use of IABP. CONCLUSION: EN is possible in the majority of patients with severe hemodynamic failure, but usually results in hypocaloric feeding. EN should be considered in patients with careful abdominal and energy monitoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intra-aortic balloon pump (IABP) is the most frequently used mechanical circulatory support. Repeated trauma on the aortic wall has been reported as a cause of balloon perforation by endothelial denudation of atheromatous plaque. This study analyses the effect of IABP on the endothelium of the calf aorta. In 12 calves (mean weight: 72 +/- 6 kg) an IABP was inserted by femoral route and left during 6 hours on internal mode with a frequency of 80 cycles/min. The animals were sacrificed after the procedure (n = 4), at postoperative day (POD) 7 (n = 4), and at POD 14 (n = 4). In the aorta facing the balloon, nine transmural samples were taken proximally (n = 3), at mid height (n = 3) and distally (n = 3), for histological analysis of the percentage of aortic surface covered with endothelium. The percentage of aortic surface covered with endothelium at POD 0, 7 and 14 was proximally: 72.5 +/- 27.5%, 83.7 +/- 16.9% and 93.3 +/- 8.9% respectively; at mid-height: 50.8 +/- 30.7%, 65 +/- 25% and 95 +/- 5%; and distally: 31.4 +/- 20.1%, 48.3 +/- 34.4% and 85 +/- 10%. A large portion of the aortic endothelium is abraded after 6 hours of IAB pumping. This effect is more important at the distal level of the aorta. After two weeks, most of the endothelium has regenerated.