16 resultados para Hysteresis of Suction
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND: Suction-based wound healing devices with open-pore foam interfaces are widely used to treat complex tissue defects. The impact of changes in physicochemical parameters of the wound interfaces has not been investigated. METHODS: Full-thickness wounds in diabetic mice were treated with occlusive dressing or a suction device with a polyurethane foam interface varying in mean pore size diameter. Wound surface deformation on day 2 was measured on fixed tissues. Histologic cross-sections were analyzed for granulation tissue thickness (hematoxylin and eosin), myofibroblast density (α-smooth muscle actin), blood vessel density (platelet endothelial cell adhesion molecule-1), and cell proliferation (Ki67) on day 7. RESULTS: Polyurethane foam-induced wound surface deformation increased with polyurethane foam pore diameter: 15 percent (small pore size), 60 percent (medium pore size), and 150 percent (large pore size). The extent of wound strain correlated with granulation tissue thickness that increased 1.7-fold in small pore size foam-treated wounds, 2.5-fold in medium pore size foam-treated wounds, and 4.9-fold in large pore size foam-treated wounds (p < 0.05) compared with wounds treated with an occlusive dressing. All polyurethane foams increased the number of myofibroblasts over occlusive dressing, with maximal presence in large pore size foam-treated wounds compared with all other groups (p < 0.05). CONCLUSIONS: The pore size of the interface material of suction devices has a significant impact on the wound healing response. Larger pores increased wound surface strain, tissue growth, and transformation of contractile cells. Modification of the pore size is a powerful approach for meeting biological needs of specific wounds.
Resumo:
The Admiral, a new microporous membrane oxygenator with a low surface area, decreased priming volume and two separate reservoirs, was tested in 30 adult patients. This study was undertaken to evaluate blood path resistance, gas exchange capabilities and blood trauma in clinical use, with and without shed blood separation. Patients were divided into 3 groups. Group 1 had valve surgery without separation of suction, Group 2 had coronary artery bypass grafting (CABG) with direct blood aspiration and Group 3 had coronary artery bypass grafting with shed blood separation. The suctioned, separated, cardiotomy blood in Group 3 was treated with an autotransfusion device at the end of bypass before being returned to the patient. Theoretical blood flow could be achieved in all cases without problem. The pressure drop through the oxygenator averaged 88 +/- 13 mmHg at 4 l/min and 109 +/- 12 mmHg at 5 l/min. O(2) transfer was 163 +/- 27 ml/min. Free plasma haemoglobin rose in all groups, but significantly less in group 3. Lactate dehydrogenase (LDH) rose significantly in Groups 1 and 2. Platelets decreased in all groups without significant differences. Clinical experience with this new oxygenator was safe, the reduced membrane surface did not impair gas exchange and blood trauma could be minimized easily by separating shed blood, using the second cardiotomy reservoir.
Resumo:
BACKGROUND: Critical decisions and interpretation of observations by the nurse caring for the paediatric intensive care (PIC) patient can have dramatic and potential adverse impact on the clinical stability of the patient. A common PIC procedure is endotracheal tube (ETT) suction, however there is inconsistent evidence regarding the clinical indicators to guide and support nursing action. Justification for performing this procedure is not clearly defined within the literature. Further, a review of the literature has failed to establish clear standards for determining if the procedure is warranted, especially for paediatric patients. OBJECTIVE: The objective of the review is to identify current clinical indicators used in practice to determine why ETT suction should be performed. METHOD: An integrative review using a systematic approach to summarise the empirical and theoretical evidence within the literature as it relates to clinical practice was used. RESULTS: Consensus of opinion indicates that ETT suctioning should only be performed when clinically indicated. There is no general consensus regarding which clinical indicators should be measured and used to guide the decision to perform ETT suctioning. CONCLUSION: Research is required to identify the clinical indicators that could be used to design a valid and clinically appropriate tool to use to assist in the decision making process to perform ETT suction.
Resumo:
Since the inception of cardiopulmonary bypass (CPB), little progress has been made concerning the design of cardiotomy suction (CS). Because this is a major source of hemolysis, we decided to test a novel device (Smartsuction [SS]) specifically aimed at minimizing hemolysis during CPB in a clinical setting. Block randomization was carried out on a treated group (SS, n=28) and a control group (CTRL, n=26). Biochemical parameters were taken pre-, peri-, and post CPB and were compared between the two groups using the Student's t-test with statistical significance when P<0.05. No significant differences in patient demographics were observed between the two groups. Lactate dehydrogenase (LDH) and plasma free hemoglobin (PFH) pre-CPB were comparable for the CTRL and SS groups, respectively. LDH peri-CPB was 275+/-100 U/L versus 207+/-83 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 486+/-204 mg/L versus 351+/-176 mg/L for the CTRL and SS groups, respectively (P<0.05). LDH post CPB was 354+/-116 U/L versus 275+/-89 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 549+/-271 mg/L versus 460+/-254 mg/L for the CTRL and SS groups, respectively (P<0.05). Preoperative hematocrit (Hct) of 43+/-5% (CTRL) versus 37+/-5% (SS), and hemoglobin (Hb) of 141+/-16 g/L (CTRL) versus 122+/-17 g/L (SS) were significantly lower in the SS group. However, when normalized (N), the SS was capable of conserving Hct, Hb, and erythrocyte count perioperatively. Erythrocytes (N) were 59+/-5% (CTRL) versus 67+/-9% (SS); Hct (N) was 59+/-6% (CTRL) versus 68+/-9% (SS), and Hb (N) was 61+/-6% (CTRL) versus 70+/-10% (SS) (all P<0.05). This novel SS device evokes significantly lowered blood PFH and LDH values peri- and post CPB compared with the CTRL blood using a CS system. The SS may be a valuable alternative compared to traditional CS techniques.
Resumo:
OBJECTIVES: The presence of intravascular foreign bodies is underreported in the literature and is more commonly encountered in clinical practice. We report on a case where an attempt to position a carotid stent resulted in misdeployment of the stent in the femoral artery and its surgical removal. METHODS: A 63-year-old patient admitted to hospital for cerebral stroke underwent thrombolysis for occlusive dissection of right carotid artery and was transferred to our hospital for additional thrombo-aspiration and carotid stenting. RESULTS: The carotid stent was misdeployed incompletely in the femoral artery and had to be removed surgically. CONCLUSIONS: Appropriate knowledge of intravascular migration and deployment failure management should be considered as important as the optimal device deployment.
Resumo:
This article examines the existence of a habituation effect to unemployment: Does the subjective well-being of unemployed people decline less if unemployment is more widespread? The underlying idea is that unemployment hysteresis may operate through a sociological channel: if many people in the community lose their job and remain unemployed over an extended period, the psychological cost of being unemployed diminishes and the pressure to accept a new job declines. We analyze this question with individual-level data from the German Socio-Economic Panel (1984-2010) and the Swiss Household Panel (2000-2010). Our fixed-effects estimates show no evidence for a mitigating effect of high surrounding unemployment on the subjective well-being of the unemployed. Becoming unemployed hurts as much when regional unemployment is high as when it is low. Likewise, the strongly harmful impact of being unemployed on well-being does not wear off over time, nor do repeated episodes of unemployment make it any better. It thus appears doubtful that an unemployment shock becomes persistent because the unemployed become used to, and hence reasonably content with, being without a job.
Resumo:
In a prospective nonrandomized study, using each baby as his or her own control, we compared intracranial pressure (anterior fontanel pressure as measured with the Digilab pneumotonometer), cerebral perfusion pressure, BP, heart rate, transcutaneous Po2, and transcutaneous Pco2 before, during, and after endotracheal suctioning, with and without muscle paralysis, in 28 critically ill preterm infants with respiratory distress syndrome. With suctioning, there was a small but significant increase in intracranial pressure in paralyzed patients (from 13.7 [mean] +/- 4.4 mm Hg [SD] to 15.8 +/- 5.2 mm Hg) but a significantly larger (P less than .001) increase when they were not paralyzed (from 12.5 +/- 3.6 to 28.5 +/- 8.3 mm Hg). Suctioning led to a slight increase in BP with (from 45.3 +/- 9.1 to 48.0 +/- 8.7 mm Hg) and without muscle paralysis (from 45.1 +/- 9.4 to 50.0 +/- 11.7 mm Hg); but there was no significant difference between the two groups. The cerebral perfusion pressure in paralyzed infants did not show any significant change before, during, and after suctioning (31.5 +/- 9.1 mm Hg before v 32.0 +/- 8.7 mm Hg during suctioning), but without muscle paralysis cerebral perfusion pressure decreased (P less than .001) from 32.8 +/- 9.7 to 21.3 +/- 13.1 mm Hg. Suctioning induced a slight decrease in mean heart rate and transcutaneous Po2, but pancuronium did not alter these changes. There was no statistical difference in transcutaneous Pco2 before, during, and after suctioning with and without muscle paralysis.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
Colloidal transport has been shown to enhance the migration of plutonium in groundwater downstream from contaminated sites, but little is known about the adsorption of ⁹⁰Sr and plutonium onto colloids in the soil solution of natural soils. We sampled soil solutions using suction cups, and separated colloids using ultrafiltration to determine the distribution of ²³⁹Pu and ⁹⁰Sr between the truly dissolved fraction and the colloidal fraction of the solutions of three Alpine soils contaminated only by global fallout from the nuclear weapon tests. Plutonium was essentially found in the colloidal fraction (>80%) and probably associated with organic matter. A significant amount of colloidal ⁹⁰Sr was detected in organic-rich soil solutions. Our results suggest that binding to organic colloids in the soil solutions plays a key role with respect to the mobility of plutonium in natural alpine soils and, to a lesser extent, to the mobility of ⁹⁰Sr.
Resumo:
Instead of standard rigid thoracoscopes, we used a modified gastroscope for video assistance during 12 minimally invasive left internal mammary harvesting. Flexibility and remote control of its last centimeters give to the gastroscope a total freedom of movements, and perfect positioning in every direction. The scope is equipped with cold light, a suction canal and an irrigation canal, which allow for in situ washing without needing to remove it from the thoracic cavity. Thanks to these advantages, vision and lighting are always perfect.
Resumo:
Unexpected ejaculation failure on the day of oocyte retrieval for IVF occurs once or twice a year in our Reproductive Medicine Unit, where approximately 500 oocyte retrievals are performed each year. Two clinical situations which occurred in 2001 are presented. In the first case, sperm were finally obtained by epididymal aspiration and resulted in the fertilization of five oocytes by ICSI. The transfer of two fresh embryos did not result in a pregnancy and the three supernumerary zygotes were cryopreserved. The male patient presented an anxio-depressive episode necessitating psychiatric hospitalization 1 week after the oocyte retrieval. In the second case, no sperm were obtained and the four oocytes were therefore lost. The couple went through a crisis in their relationship and tried another cycle of IVF 10 months later, after the preventive cryopreservation of a sperm sample. On the day of oocyte retrieval the patient was unable to produce a fresh sample but three zygotes were obtained through ICSI using the back-up cryopreserved sperm. Two embryos were transferred but no pregnancy ensued. The clinical decision-making processes for these two cases are described, as well as the measures employed to help prevent these unfortunate situations.
Resumo:
Background: Complex wounds pose a major challenge in reconstructive and trauma surgery. Several approaches to increase the healing process have been proposed in the last decades. In this study we study the mechanism of action of the Vacuum Assisted Closure device in diabetic wounds. Methods: Full-thickness wounds were excised in diabetic mice and treated with the VAC device or its isolated components: an occlusive dressing (OD) alone, subathmospheric pressure at 125 mm Hg (Suction), and a polyurethane foam without (Foam) and with (Foamc) downward compression of approximately 125 mm Hg. The last goups were treated with either the complete VAC device (VAC) or with a silicne interface that alows fluid removel (Mepithel-VAC). The effects of the treatment modes on the wound surface were quantified by a two-dimensional immunohistochemical staging system based on vasculature, as defined by blood vessel density (CD31) and cell proliferation (defined by ki67 positivity), 7 days post wounding. Finite element modelling was used to predict wound surface deformation under dressing modes and cross sections of in situ fixed tissues were used to measure actual microstrain. Results: The foam-wound interface of the Vacuum Assisted Closure device causes significant wound stains (60%) causing a deformation of the single cell level leading to a profound upregulation of cell proliferation (4-fold) and angiogenisis (2.2-fold) compared to OD treated wounds. Polyurethane foam exposure itself causes a frather unspecific angiogenic response (Foamc, 2 - fold, Foam, 2.2 - fold) without changes of the cell proliferation rate of the wound bed. Suction alone without a specific interface does not have an effect on meassured parameters, showing similar results to untreated wounds. A perforated silicone interface caused a significant lower microdeforamtion of the wound bed correlating to changes of the wound tissues. Conclusion: The Vacuum Assisted Closure device induce significanttissue growth in diabetic wounds. The wound foam interface under suction causes profound macrodeformation that stimulates tissue growth by angiogenesis and cell proliferation. It needs to be taken in consideration that in the clinical setting different wound types may profit from different elements of this suction device.
Resumo:
BACKGROUND: Pancreatic fistula (PF), which is a major complication of pancreaticoduodenectomy (PD), can be treated conservatively or by reoperation. The aim of this study was to evaluate conservative management of PF, which was attempted whenever possible as a first-intention treatment in a large series of PD. STUDY DESIGN: From 1990 to 2000, 242 patients underwent PD with pancreaticogastrostomy. PF was observed in 31 (13%) and was defined by an amylase-rich surgical drainage fluid (above fivefold serum amylase) after postoperative day 5, or by presence on CT scan of a fluid collection located close to the anastomosis or containing amylase-rich fluid, or by operative findings in case of reoperation. Conservative management included total parenteral nutrition, nasogastric suction, imaging-guided percutaneous drainage of collection when necessary, and somatostatin or its analogues. RESULTS: PF was symptomatic in 20 patients (65%). Amylase level on surgical drainage fluid was elevated in 23 patients (74%). Four patients (13%), including two with hemorrhage and two with intraabdominal collection not accessible by percutaneous approach, were not considered for conservative management and underwent early reoperation. Conservative management was successful in the 27 patients (100%) in whom it was attempted, including the 10 who required percutaneous drainage. The only death (3%) occurred after massive hemorrhage complicating misdiagnosed PF. Mean hospital stay was 36 +/- 12 days (range 18 to 71) after successful conservative management. CONCLUSIONS: Conservative management of PF complicating PD is feasible and successful in above 85% of patients.
Resumo:
OBJECTIVE: The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-up to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. METHODS: In a calf model (n=10; mean weight, 69.3+/-4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blood was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. RESULTS: In the Smart suction group, red cell count, plasma protein and free hemoglobin levels remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683+/-201*10(9)/l, 5 h: 280+/-142*10(9)/l, P=0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6+/-0.9*10(12)/l, 6 h: 6.3+/-0.4*10(12)/l, P=0.02), of the platelet count from the first hour onwards (prebypass: 630+/-97*10(9)/l, 1 h: 224+/-75*10(9)/l, P<0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7+/-0.6 g/l, 1 h: 29.3+/-9.1 g/l, P<0.01). CONCLUSIONS: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences.
Resumo:
This paper examines the existence of a habituation effect to unemployment: Do theunemployed suffer less from job loss if unemployment is more widespread, if their ownunemployment lasts longer and if unemployment is a recurrent experience? Theunderlying idea is that unemployment hysteresis may operate through a sociologicalchannel: if many people in the community lose their job and remain unemployed over anextended period, the psychological cost of being unemployed diminishes and the pressureto accept a new job declines. We analyze this question with individual-level data from theGerman Socio-Economic Panel (1984-2009) and the Swiss Household Panel (2000-2009). We find no evidence for a mitigating effect of high surrounding unemployment onunemployed individuals' subjective well-being: Becoming unemployed hurts as muchwhen regional unemployment is high as when it is low. Likewise, the strongly harmfulimpact of being unemployed on well-being does not wear off over time, nor do repeatedepisodes of unemployment make it any better. It thus appears doubtful that anunemployment shock becomes persistent because the unemployed become used to, andhence reasonably content with, being without a job.