123 resultados para Heart valve diseases
em Université de Lausanne, Switzerland
Resumo:
Trans-apical aortic valve replacement (AVR) is a new and rapidly growing therapy. However, there are only few training opportunities. The objective of our work is to build an appropriate artificial model of the heart that can replace the use of animals for surgical training in trans-apical AVR procedures. To reduce the necessity for fluoroscopy, we pursued the goal of building a translucent model of the heart that has nature-like dimensions. A simplified 3D model of a human heart with its aortic root was created in silico using the SolidWorks Computer-Aided Design (CAD) program. This heart model was printed using a rapid prototyping system developed by the Fab@Home project and dip-coated two times with dispersion silicone. The translucency of the heart model allows the perception of the deployment area of the valved-stent without using heavy imaging support. The final model was then placed in a human manikin for surgical training on trans-apical AVR procedure. Trans-apical AVR with all the necessary steps (puncture, wiring, catheterization, ballooning etc.) can be realized repeatedly in this setting.
Resumo:
The importance of the right ventricle as a determinant of clinical symptoms, exercise capacity, peri-operative survival and postoperative outcome has been underestimated for a long time. Right ventricular ejection fraction has been used as a measure of right ventricular function but has been found to be dependent on loading conditions, ventricular interaction as well as on myocardial structure. Altered left ventricular function in patients with valvular disease influences right ventricular performance mainly by changes in afterload but also by ventricular interaction. Right ventricular function and regional wall motion can be determined with right ventricular angiography, radionuclide ventriculography, two-dimensional echocardiography or magnetic resonance imaging. However, the complex structure of the right ventricle and its pronounced translational movements render quantification difficult. True regional wall motion analysis is, however, possible with myocardial tagging based on magnetic resonance techniques. With this technique a baso-apical shear motion of the right ventricle was observed which was enhanced in patients with aortic stenosis.
Resumo:
In the developing heart, Notch signaling plays an essential role in several key developmental processes, such as epithelial-to-mesenchymal transition and myocyte proliferation and differentiation. The importance of Notch in cardiac development has been demonstrated in knockout mice carrying null mutations in genes encoding components of the Notch pathway. Furthermore, humans with inactivating mutations in the Notch ligand Jagged1 suffer from Alagille syndrome, a condition characterized by several cardiac defects. Notch1 receptor haploinsufficiency has also been involved in aortic valve disease in humans. In addition, accumulating evidence indicates that Notch may also regulate homeostasis in the adult heart. Notch may protect the heart from an excessive and detrimental hypertrophic response and increase cardiomyocyte survival. Emerging evidence also suggests that Notch could be important for cardiac tissue renewal by controlling the maintenance and commitment of a cardiac stem cell compartment.
Resumo:
In some high-risk patients, standard mitral valve replacement can represent a challenging procedure, requiring a risky extensive decalcification of the annulus. In particular, high-risk redo patients and patients with a previously implanted transcatheter aortic valve, who develop calcific mitral disease, would benefit from the development of new, minimally invasive, transcatheter or hybrid techniques for mitral valve replacement. In particular, mixing transcatheter valve therapies and well-established minimally invasive techniques for mitral replacement or repair can help in decreasing the surgical risk and the technical complexity. Thus, placing transcatheter, balloon-expandable Sapien? XT stent-valves in calcified, degenerated mitral valves through a right thoracotomy, a left atriotomy and on an on-pump fibrillating heart, represents an attractive alternative to standard surgery in redo patients, in patients with concomitant transcatheter aortic stent-valves in place and in patients with a high-risk profile. We describe this hybrid technique in detail.
Resumo:
The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.
Resumo:
Recent advances in CT technologies had significantly improved the clinical utility of cardiac CT. Major efforts have been made to optimize the image quality, standardize protocols and limit the radiation exposure. Rapid progress in post-processing tools dedicated not only to the coronary artery assessment but also to the cardiac cavities, valves and veins extended applications of cardiac CT. This potential might be however used optimally considering the current appropriate indications for use as well as the current technical imitations. Coronary artery disease and related ischemic cardiomyopathy remain the major applications of cardiac CT and at the same time the most complex one. Integration of a specific knowledge is mandatory for optimal use in this area for asymptomatic as for symptomatic patients, with a specific regards to patient with acute chest pain. This review aimed to propose a practical approach to implement appropriate indications in our routine practice. Emerging indications and future direction are also discussed. Adequate preparation of the patient, training of physicians, and the multidisciplinary interaction between actors are the key of successful implementation of cardiac CT in daily practice.
Resumo:
CONTEXT: Infection of implantable cardiac devices is an emerging disease with significant morbidity, mortality, and health care costs. OBJECTIVES: To describe the clinical characteristics and outcome of cardiac device infective endocarditis (CDIE) with attention to its health care association and to evaluate the association between device removal during index hospitalization and outcome. DESIGN, SETTING, AND PATIENTS: Prospective cohort study using data from the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), conducted June 2000 through August 2006 in 61 centers in 28 countries. Patients were hospitalized adults with definite endocarditis as defined by modified Duke endocarditis criteria. MAIN OUTCOME MEASURES: In-hospital and 1-year mortality. RESULTS: CDIE was diagnosed in 177 (6.4% [95% CI, 5.5%-7.4%]) of a total cohort of 2760 patients with definite infective endocarditis. The clinical profile of CDIE included advanced patient age (median, 71.2 years [interquartile range, 59.8-77.6]); causation by staphylococci (62 [35.0% {95% CI, 28.0%-42.5%}] Staphylococcus aureus and 56 [31.6% {95% CI, 24.9%-39.0%}] coagulase-negative staphylococci); and a high prevalence of health care-associated infection (81 [45.8% {95% CI, 38.3%-53.4%}]). There was coexisting valve involvement in 66 (37.3% [95% CI, 30.2%-44.9%]) patients, predominantly tricuspid valve infection (43/177 [24.3%]), with associated higher mortality. In-hospital and 1-year mortality rates were 14.7% (26/177 [95% CI, 9.8%-20.8%]) and 23.2% (41/177 [95% CI, 17.2%-30.1%]), respectively. Proportional hazards regression analysis showed a survival benefit at 1 year for device removal during the initial hospitalization (28/141 patients [19.9%] who underwent device removal during the index hospitalization had died at 1 year, vs 13/34 [38.2%] who did not undergo device removal; hazard ratio, 0.42 [95% CI, 0.22-0.82]). CONCLUSIONS: Among patients with CDIE, the rate of concomitant valve infection is high, as is mortality, particularly if there is valve involvement. Early device removal is associated with improved survival at 1 year.
Resumo:
Because of its severity, it is agreed that infectious endocarditis should be prevented whenever possible. Determining adequate prophylactic measures involves establishing (a) the patients at risk, (b) the procedures that might provoke bacteraemia, (c) the most effective prophylactic regimen, and (d) a balance between the risks of side effects from prophylaxis and of developing infectious endocarditis. Patients at risk and procedures inducing bacteraemia have been identified by clinical studies. On the other hand, the efficacy of prophylactic antibiotics has been based on animal studies. Randomised, placebo-controlled studies do not exist in humans because they would require large patient numbers and would raise ethical issues due to the severity of the disease. Case-control studies have indicated that infectious endocarditis prophylaxis is effective, but prevents only a limited number of cases. Animal experiments have revealed several key issues for human application. First, antibiotics do not prevent the early stages of valve colonisation, but rather kill the microorganisms after their attachment to the cardiac lesions. Second, the duration of antibiotic presence in the serum is critical. Under experimental conditions, the drugs must remain above their minimal inhibitory concentration for the organisms for > or = 10 h, to allow time for bacterial clearance from the valves. Third, antibiotic-induced killing is not the only mechanism allowing bacterial clearance. Other factors, such as platelet microbicidal proteins, may act in concert with the drugs to sterilise the lesions. Recommendations for prophylaxis have recently been revised in Europe and the USA. New information has improved the definition of groups at risk. Since most cases of infectious endocarditis are not preceded by medical procedures, primary prevention of infectious endocarditis should target infected foci responsible for spontaneous bacteraemia (e.g. poor dental hygiene). The purpose of this article is to update the existing recommendations in Switzerland, under the perspective of changing epidemiology, the availability of new drugs, and harmonisation with recommendations in other countries.
Resumo:
The short and the long-term results of our experience with 25 consecutive patients who underwent multivalvular surgery for infective endocarditis are analysed. Preoperatively, 20/25 (80%) patients were in New York Heart Association (NYHA) stage III or IV, and 2/25 (8%) patients were in cardiogenic shock. All the diseased valves were replaced with mechanical bileaflet prosthesis except seven mitral valves and one tricuspid valve, which could be repaired. Major postoperative complications occurred in 3/25 (12%) patients: a fatal cerebral haemorrhage, a reversible cerebellar syndrome and an intractable heart failure, which required transplantation. During a mean follow-up of 4.7 years (range 6 months to 16.8 years), 7/25 (28%) patients suffered from valve-related complications: five bleedings (one died), one embolic event and one prosthetic valve thrombosis. The actuarial freedom of valve-related event at 10 years was 61.8 +/- 12.4%. There was no prosthetic endocarditis. At follow-up, 20/21 (95%) survivors were in NYHA stage I or II. Long-term outcome in our patient population operated on for multivalvular endocarditis, is satisfactory with no recurrent infection and excellent functional results.
Resumo:
Between September 1979 and December 1982, 56 St Jude Medical valvular prostheses were implanted in 54 patients over 65 years of age. Surgery consisted in simple aortic valve replacement (35 cases), simple mitral valve replacement (12 cases), double aortic and mitral valve replacement (2 cases), valve replacement and coronary artery bypass surgery (3 cases), aortic valve replacement and replacement of the ascending aorta (1 case) and mitral valve replacement and tricuspid annuloplasty (1 case). The operative mortality (within 30 days of surgery) was 3.5% (2 cases). Patients were assessed by clinical examination, ECG, chest X-ray, echocardiogram and laboratory investigations on average 19 months after surgery. There were 3 late deaths (1 endocarditis, 1 cardiac failure and 1 subdural haematoma). No cases of significant haemolysis were observed. There were no cases of thrombosis of the valve or any deaths directly related to the valve. Four patients had cerebral embolism (4.9% per patient/year). None were fatal and only 1 patient had sequellae. Clinical improvement was very significant; 96% of the patients are now in the NYHA Classes I and II whilst 80% were in Class III or IV before surgery. The cardiothoracic ratio decreased significantly from 0.56 to 0.51 (p less than 0.01). The authors conclude that elderly patients may derive great benefits from valvular cardiac surgery and that age in itself is not a contraindication to this type of surgery. The St Jude Medical prosthesis is an excellent prosthesis but thromboembolism remains a major problem as with other mechanical prostheses. Anticoagulation for life is essential.
Resumo:
Echocardiography is a key tool in the diagnosis of infective endocarditis. Although transthoracic echocardiography is the first step in the work-up, transoesophageal echocardiography is mandatory for the evaluation of the exact extent of the infectious process. Indeed, perivalvular abscess can fistulate towards different heart chambers, leading sometimes to critical clinical situations.
Resumo:
Because of the development of modern transportation facilities, an ever rising number of individuals including many patients with preexisting diseases visit high-altitude locations (>2500 m). High-altitude exposure triggers a series of physiologic responses intended to maintain an adequate tissue oxygenation. Even in normal subjects, there is enormous interindividual variability in these responses that may be further amplified by environmental factors such as cold temperature, low humidity, exercise, and stress. These adaptive mechanisms, although generally tolerated by most healthy subjects, may induce major problems in patients with preexisting cardiovascular diseases in which the functional reserves are already limited. Preexposure assessment of patients helps to minimize risk and detect contraindications to high-altitude exposure. Moreover, the great variability and nonpredictability of the adaptive response should encourage physicians counseling such patients to adapt a cautionary approach. Here, we will briefly review how high-altitude adjustments may interfere with and aggravate/decompensate preexisting cardiovascular diseases. Moreover, we will provide practical recommendations on how to investigate and counsel patients with cardiovascular disease desiring to travel to high-altitude locations.
Resumo:
We reviewed our surgery registry, to identify predictive risk factors for operative results, and to analyse the long-term survival outcome in octogenarians operated for primary isolated aortic valve replacement (AVR). A total of 124 consecutive octogenarians underwent open AVR from January 1990 to December 2005. Combined procedures and redo surgery were excluded. Selected variables were studied as risk factors for hospital mortality and early neurological events. A follow-up (FU; mean FU time: 77 months) was obtained (90% complete), and Kaplan-Meier plots were used to determine survival rates. The mean age was 82+/-2.2 (range: 80-90 years; 63% females). Of the group, four patients (3%) required urgent procedures, 10 (8%) had a previous myocardial infarction, six (5%) had a previous coronary angioplasty and stenting, 13 patients (10%) suffered from angina and 59 (48%) were in the New York Heart Association (NYHA) class III-IV. We identified 114 (92%) degenerative stenosis, six (5%) post-rheumatic stenosis and four (3%) active endocarditis. The predicted mortality calculated by logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) was 12.6+/-5.7%, and the observed hospital mortality was 5.6%. Causes of death included severe cardiac failure (four patients), multi-organ failure (two) and sepsis (one). Complications were transitory neurological events in three patients (2%), short-term haemodialysis in three (2%), atrial fibrillation in 60 (48%) and six patients were re-operated for bleeding. Atrio-ventricular block, myocardial infarction or permanent stroke was not detected. The age at surgery and the postoperative renal failure were predictors for hospital mortality (p value <0.05), whereas we did not find predictors for neurological events. The mean FU time was 77 months (6.5 years) and the mean age of surviving patients was 87+/-4 years (81-95 years). The actuarial survival estimates at 5 and 10 years were 88% and 50%, respectively. Our experience shows good short-term results after primary isolated standard AVR in patients more than 80 years of age. The FU suggests that aortic valve surgery in octogenarians guarantees satisfactory long-term survival rates and a good quality of life, free from cardiac re-operations. In the era of catheter-based aortic valve implantation, open-heart surgery for AVR remains the standard of care for healthy octogenarians.
Resumo:
When we think of cardiac affection in the context of systemic lupus erythematosus (SLE), we usually refer to pericarditis first. As frequent as this affection is, it is actually not the only cardio-vascular problem that occurs with this systemic inflammatory disease. Are the cardiac events--ranging from multiple heart valve involvements to increased cardiovascular risks--clinically significant? And are they involving a specific follow-up, treatment or support? We are therefore trying to evaluate these questions in order to give some recommendations to any practitioners following up a lupus patient, or a patient suffering from any other inflammatory systemic disease.