99 resultados para Hand-held devices
em Université de Lausanne, Switzerland
Resumo:
The motivation for this research initiated from the abrupt rise and fall of minicomputers which were initially used both for industrial automation and business applications due to their significantly lower cost than their predecessors, the mainframes. Later industrial automation developed its own vertically integrated hardware and software to address the application needs of uninterrupted operations, real-time control and resilience to harsh environmental conditions. This has led to the creation of an independent industry, namely industrial automation used in PLC, DCS, SCADA and robot control systems. This industry employs today over 200'000 people in a profitable slow clockspeed context in contrast to the two mainstream computing industries of information technology (IT) focused on business applications and telecommunications focused on communications networks and hand-held devices. Already in 1990s it was foreseen that IT and communication would merge into one Information and communication industry (ICT). The fundamental question of the thesis is: Could industrial automation leverage a common technology platform with the newly formed ICT industry? Computer systems dominated by complex instruction set computers (CISC) were challenged during 1990s with higher performance reduced instruction set computers (RISC). RISC started to evolve parallel to the constant advancement of Moore's law. These developments created the high performance and low energy consumption System-on-Chip architecture (SoC). Unlike to the CISC processors RISC processor architecture is a separate industry from the RISC chip manufacturing industry. It also has several hardware independent software platforms consisting of integrated operating system, development environment, user interface and application market which enables customers to have more choices due to hardware independent real time capable software applications. An architecture disruption merged and the smartphone and tablet market were formed with new rules and new key players in the ICT industry. Today there are more RISC computer systems running Linux (or other Unix variants) than any other computer system. The astonishing rise of SoC based technologies and related software platforms in smartphones created in unit terms the largest installed base ever seen in the history of computers and is now being further extended by tablets. An underlying additional element of this transition is the increasing role of open source technologies both in software and hardware. This has driven the microprocessor based personal computer industry with few dominating closed operating system platforms into a steep decline. A significant factor in this process has been the separation of processor architecture and processor chip production and operating systems and application development platforms merger into integrated software platforms with proprietary application markets. Furthermore the pay-by-click marketing has changed the way applications development is compensated: Three essays on major trends in a slow clockspeed industry: The case of industrial automation 2014 freeware, ad based or licensed - all at a lower price and used by a wider customer base than ever before. Moreover, the concept of software maintenance contract is very remote in the app world. However, as a slow clockspeed industry, industrial automation has remained intact during the disruptions based on SoC and related software platforms in the ICT industries. Industrial automation incumbents continue to supply systems based on vertically integrated systems consisting of proprietary software and proprietary mainly microprocessor based hardware. They enjoy admirable profitability levels on a very narrow customer base due to strong technology-enabled customer lock-in and customers' high risk leverage as their production is dependent on fault-free operation of the industrial automation systems. When will this balance of power be disrupted? The thesis suggests how industrial automation could join the mainstream ICT industry and create an information, communication and automation (ICAT) industry. Lately the Internet of Things (loT) and weightless networks, a new standard leveraging frequency channels earlier occupied by TV broadcasting, have gradually started to change the rigid world of Machine to Machine (M2M) interaction. It is foreseeable that enough momentum will be created that the industrial automation market will in due course face an architecture disruption empowered by these new trends. This thesis examines the current state of industrial automation subject to the competition between the incumbents firstly through a research on cost competitiveness efforts in captive outsourcing of engineering, research and development and secondly researching process re- engineering in the case of complex system global software support. Thirdly we investigate the industry actors', namely customers, incumbents and newcomers, views on the future direction of industrial automation and conclude with our assessments of the possible routes industrial automation could advance taking into account the looming rise of the Internet of Things (loT) and weightless networks. Industrial automation is an industry dominated by a handful of global players each of them focusing on maintaining their own proprietary solutions. The rise of de facto standards like IBM PC, Unix and Linux and SoC leveraged by IBM, Compaq, Dell, HP, ARM, Apple, Google, Samsung and others have created new markets of personal computers, smartphone and tablets and will eventually also impact industrial automation through game changing commoditization and related control point and business model changes. This trend will inevitably continue, but the transition to a commoditized industrial automation will not happen in the near future.
Resumo:
OBJECTIVES: To test the validity of a simple, rapid, field-adapted, portable hand-held impedancemeter (HHI) for the estimation of lean body mass (LBM) and percentage body fat (%BF) in African women, and to develop specific predictive equations. DESIGN: Cross-sectional observational study. SETTINGS: Dakar, the capital city of Senegal, West Africa. SUBJECTS: A total sample of 146 women volunteered. Their mean age was of 31.0 y (s.d. 9.1), weight 60.9 kg (s.d. 13.1) and BMI 22.6 kg/m(2) (s.d. 4.5). METHODS: Body composition values estimated by HHI were compared to those measured by whole body densitometry performed by air displacement plethysmography (ADP). The specific density of LBM in black subjects was taken into account for the calculation of %BF from body density. RESULTS: : Estimations from HHI showed a large bias (mean difference) of 5.6 kg LBM (P<10(-4)) and -8.8 %BF (P<10(-4)) and errors (s.d. of the bias) of 2.6 kg LBM and 3.7 %BF. In order to correct for the bias, specific predictive equations were developed. With the HHI result as a single predictor, error values were of 1.9 kg LBM and 3.7 %BF in the prediction group (n=100), and of 2.2 kg LBM and 3.6 %BF in the cross-validation group (n=46). Addition of anthropometrical predictors was not necessary. CONCLUSIONS: The HHI analyser significantly overestimated LBM and underestimated %BF in African women. After correction for the bias, the body compartments could easily be estimated in African women by using the HHI result in an appropriate prediction equation with a good precision. It remains to be seen whether a combination of arm and leg impedancemetry in order to take into account lower limbs would further improve the prediction of body composition in Africans.
Resumo:
Background and Aims: normal weight obesity (NWO) has been defined as an excessive body fat (BF) associated with a normal body mass index (BMI). Little is known regarding its prevalence in the general population or which cut-offs for BF should be used. Methods: convenience sample of 1,523 Portuguese adults. BF was measured by validated hand-held bioimpedance. NWO was defined as a BMI<25 kg/m2 and a %BF mass>30%, along other published criteria. Results: prevalence of NWO was 10.1% in women and 3.2% in men. In women, prevalence of NWO increased considerably with age, and virtually all women aged over 55 with a BMI<25 kg/m2 were actually considered as NWO. Using gender specific cut-offs for BF (29.1% in men and 37.2% in women) led to moderately lower of NWO in women. Using gender- and age-specific cut-points for %BF considerably decreased the prevalence of NWO in women (0.5 to 2.5% depending on the criterion) but not in men (1.9 to 3.4%). Conclusions: gender- and age- specific or at least gender-specific, instead of single cut-offs for %BF, should be used to characterize and study NWO.
Resumo:
BACKGROUND AND AIMS: There is little information regarding the effect of different definitions of obesity on nutritional epidemiology. The aim was thus to assess: (a) the values of percentage of body fat (%BF) by gender and age; (b) the prevalence of obesity according to different %BF cut-offs; and (c) the sensitivity and specificity of BMI according to different %BF cut-offs used to define obesity. METHODS: Cross-sectional study on 2494 boys and 2519 girls aged 1018 years from the Lisbon area. %BF was measured using a hand-held device. In a sub sample of 211 boys and 724 girls %BF was assessed using skin folds. RESULTS: %BF levels were higher in girls and decreased with age in both genders. Prevalence of obesity varied considerably according to the %BF cut-off used: in boys, it ranged from 4.7% (age-specific 95th percentile) to 26.5% (fixed 25% cut-off), whereas by BMI it was 5.3%. In girls, prevalence of obesity ranged from 0.4% (age-specific BMI-derived %BF values) to 25.4% (fixed 30% cut-off), whereas by BMI it was 4.7%. The specificity of BMI criteria was over 95% irrespective of the %BF cut-off used; conversely, most sensitivities were below 40%. Sensitivities over 50% were obtained for the age-specific BMI-derived %BF values in boys and the age-specific 95th %BF percentile in both genders. Using %BF derived from the skin fold measurements leads to similar results. CONCLUSIONS: Prevalence of obesity varies considerably according to the %BF cut-off used. BMI cut-offs have a low sensitivity but a high specificity. Age- and gender-specific cut-offs for %BF should be used to define pediatric obesity.
Resumo:
BACKGROUND AND AIMS: Normal weight obesity (NWO) has been defined as an excessive body fat (BF) associated with a normal body mass index (BMI). Still, little is known regarding the effect of differing cut-offs for %BF on the prevalence of NWO. We thus conducted a study to assess the effect of modifying the cut-offs for excessive %BF on the prevalence of NWO. METHODS: We examined a convenience sample of 1523 Portuguese adults. BF was measured by validated hand-held bioimpedance. NWO was defined as a BMI < 25 kg/m2 and a %BF >30% or according to sex- and age-specific %BF cut-offs. RESULTS: Prevalence of NWO was 10.1% in women and 3.2% in men. In women, prevalence of NWO increased considerably with age, and virtually all women aged over 55 with a BMI < 25 kg/m2 were actually considered as NWO. Using sex-specific cut-offs for BF (men: 29.1%; women: 37.2%) led to moderately lower prevalence of NWO in women. Using sex and age-specific cut-offs for %BF considerably decreased the prevalence of NWO in women, i.e. 0.5e2.5% (depending on the criterion) but not in men, i.e. 1.9e3.4%. CONCLUSIONS: In women, the prevalence of NWO varies considerably according to the cut-off used to define excess BF, whereas a much smaller variation is found in men. While further studies are needed to describe the risk associated with NWO using various %BF cut-offs, this study suggests that sex- and age-specific cut-offs may be preferred.
Resumo:
Prospective comparative evaluation of patent V blue, fluorescein and (99m)TC-nanocolloids for intraoperative sentinel lymph node (SLN) mapping during surgery for non-small cell lung cancer (NSCLC). Ten patients with peripherally localised clinical stage I NSCLC underwent thoracotomy and peritumoral subpleural injection of 2 ml of patent V blue dye, 1 ml of 10% fluorescein and 1ml of (99m)Tc-nanocolloids (0.4 mCi). The migration and spatial distribution pattern of the tracers was assessed by direct visualisation (patent V blue), visualisation of fluorescence signalling by a lamp of Wood (fluorescein) and radioactivity counting with a hand held gamma-probe ((99m)Tc-nanocolloids). Lymph nodes at interlobar (ATS 11), hilar (ATS 10) and mediastinal (right ATS 2,4,7; left ATS 5,6,7) levels were systematically assessed every 10 min up to 60 min after injection, followed by lobectomy and formal lymph node dissection. Successful migration from the peritumoral area to the mediastinum was observed for all three tracers up to 60 min after injection. The interlobar lympho-fatty tissue (station ATS 11) revealed an early and preferential accumulation of all three tracers for all tumours assessed and irrespective of the tumour localisation. However, no preferential accumulation in one or two distinct lymph nodes was observed up to 60 min after injection for all three tracers assessed. Intraoperative SLN mapping revealed successful migration of the tracers from the site of peritumoral injection to the mediastinum, but in a diffuse pattern without preferential accumulation in sentinel lymph nodes.
Resumo:
BACKGROUND: Living in a multisensory world entails the continuous sensory processing of environmental information in order to enact appropriate motor routines. The interaction between our body and our brain is the crucial factor for achieving such sensorimotor integration ability. Several clinical conditions dramatically affect the constant body-brain exchange, but the latest developments in biomedical engineering provide promising solutions for overcoming this communication breakdown. NEW METHOD: The ultimate technological developments succeeded in transforming neuronal electrical activity into computational input for robotic devices, giving birth to the era of the so-called brain-machine interfaces. Combining rehabilitation robotics and experimental neuroscience the rise of brain-machine interfaces into clinical protocols provided the technological solution for bypassing the neural disconnection and restore sensorimotor function. RESULTS: Based on these advances, the recovery of sensorimotor functionality is progressively becoming a concrete reality. However, despite the success of several recent techniques, some open issues still need to be addressed. COMPARISON WITH EXISTING METHOD(S): Typical interventions for sensorimotor deficits include pharmaceutical treatments and manual/robotic assistance in passive movements. These procedures achieve symptoms relief but their applicability to more severe disconnection pathologies is limited (e.g. spinal cord injury or amputation). CONCLUSIONS: Here we review how state-of-the-art solutions in biomedical engineering are continuously increasing expectances in sensorimotor rehabilitation, as well as the current challenges especially with regards to the translation of the signals from brain-machine interfaces into sensory feedback and the incorporation of brain-machine interfaces into daily activities.
Resumo:
To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.
Resumo:
Workers performing preparation and administration of radiopharmaceuticals in NM departments are likely to receive high local skin doses to the hands which may even surpass the dose limit of 500 mSv whenever radiation protection standards are insufficient. A large measurement campaign was organised within the framework of the ORAMED project to determine the dose distribution across the hands received during preparation and administration of 18F- and 99mTc-labelled radiopharmaceuticals. The final data, collected over almost 3 years, include 641 measurements from 96 workers in 30 NM departments from 6 European countries. Results have provided levels of reference doses for the considered standard NM diagnostic procedures (mean maximum normalised skin dose of 230 μSv/GBq, 430 μSv/GBq, 930 μSv/GBq and 1200 μSv/GBq for the administration of 99mTc, preparation of 99mTc, administration of 18F and preparation of 18F, respectively). Finger dose was analysed as a function of the potential parameters of influence showing that shielding is the most efficient means of radiation protection to reduce skin dose. An appropriate method for routine monitoring of the extremities is also proposed: the base of the index finger of the non-dominant hand is a suitable position to place the ring dosemeter, with its sensitive part oriented towards the palm side; its reading may be multiplied by a factor of 6 to estimate the maximum local skin dose. Finally, results were compared to earlier published data, which correspond mostly to individual works with a reduced number of workers and measurements.
Resumo:
Background: Temporary percutaneous left ventricular assist devices (TPLVAD) can be inserted and removed in awake patients. They substitute left ventricular function for a period of up to a few weeks and provide an excellent backup and bridge to recovery or decision. Methods: Retrospective analysis of 75 patients who received TPLVAD to treat cardiogenic shock (n = 49) or to facilitate high-risk percutaneous coronary intervention (PCI) (n = 26). Forty-two patients with cardiogenic shock and 16 patients with high-risk PCI received a TandemHeart and 7 patients and 10 patients, respectively, received an Impella Recover LP 2.5. Outcome and related complications up to 1 month are reported with reference to device depending function. Results: One-month survival was 53% in patients with shock and 96% in patients with PCI. Conclusion: TPLVADs can support the failing heart with acceptable risk. Outcome is better in prophylactic use than in patients with cardiogenic shock. (C) 2011 Wiley-Liss, Inc.