64 resultados para Geometric stiffness
em Université de Lausanne, Switzerland
Resumo:
Age is the main clinical determinant of large artery stiffness. Central arteries stiffen progressively with age, whereas peripheral muscular arteries change little with age. A number of clinical studies have analyzed the effects of age on aortic stiffness. Increase of central artery stiffness with age is responsible for earlier wave reflections and changes in pressure wave contours. The stiffening of aorta and other central arteries is a potential risk factor for increased cardiovascular morbidity and mortality. Arterial stiffening with aging is accompanied by an elevation in systolic blood pressure (BP) and pulse pressure (PP). Although arterial stiffening with age is a common situation, it has now been confirmed that older subjects with increased arterial stiffness and elevated PP have higher cardiovascular morbidity and mortality. Increase in aortic stiffness with age occurs gradually and continuously, similarly for men and women. Cross-sectional studies have shown that aortic and carotid stiffness (evaluated by the pulse wave velocity) increase with age by approximately 10% to 15% during a period of 10 years. Women always have 5% to 10% lower stiffness than men of the same age. Although large artery stiffness increases with age independently of the presence of cardiovascular risk factors or other associated conditions, the extent of this increase may depend on several environmental or genetic factors. Hypertension may increase arterial stiffness, especially in older subjects. Among other cardiovascular risk factors, diabetes type 1 and 2 accelerates arterial stiffness, whereas the role of dyslipidemia and tobacco smoking is unclear. Arterial stiffness is also present in several cardiovascular and renal diseases. Patients with heart failure, end stage renal disease, and those with atherosclerotic lesions often develop central artery stiffness. Decreased carotid distensibility, increased arterial thickness, and presence of calcifications and plaques often coexist in the same subject. However, relationships between these three alterations of the arterial wall remain to be explored.
Resumo:
The stiffness of tumor cells varies during cancer progression. In particular, metastatic carcinoma cells analyzed by Atomic Force Microscopy (AFM) appear softer than non-invasive and normal cells. Here we examined by AFM how the stiffness of melanoma cells varies during progression from non-invasive Radial Growth Phase (RGP) to invasive Vertical Growth Phase (VGP) and to metastatic tumors. We show that transformation of melanocytes to RGP and to VGP cells is characterized by decreased cell stiffness. However, further progression to metastatic melanoma is accompanied by increased cell stiffness and the acquisition of higher plasticity by tumor cells, which is manifested by their ability to greatly augment or reduce their stiffness in response to diverse adhesion conditions. We conclude that increased plasticity, rather than decreased stiffness as suggested for other tumor types, is a marker of melanoma malignancy. These findings advise caution about the potential use of AFM for melanoma diagnosis. FROM THE CLINICAL EDITOR: This study investigates the changes to cellular stiffness in metastatic melanoma cells examined via atomic force microscopy. The results demonstrate that increased plasticity is a marker of melanoma malignancy, as opposed to decreased stiffness.
Resumo:
OBJECTIVE: To evaluate the impact of body position on the arterial stiffness indices provided by radial applanation tonometry in pregnant and nonpregnant women. METHODS: Twenty-four young women (18-30 years) in the third trimester of a normal pregnancy and 20 healthy nonpregnant women of the same age were enrolled. In each, applanation tonometry was carried out in the sitting and supine position. The following stiffness indices were analyzed: systolic augmentation index (sAix), sAix adjusted for heart rate (sAix@75) and diastolic augmentation index (dAix), all expressed in % of central aortic pulse pressure. RESULTS: The sAix was apparently not influenced by body position, but the transition from seated to supine was associated with a substantial decrease in heart rate. When correcting for this confounder by calculating the sAix@75, systolic augmentation was substantially lower when individuals were supine (mean ± SD: nonpregnant 3.0 ± 14.4%, pregnant 8.8 ± 9.7%) than when they were sitting (nonpregnant 5.7 ± 13.0%, pregnant 11.1 ± 83%, P = 0.005 supine vs. seated in both study groups, P > 0.2 for pregnant vs. nonpregnant). The influence of body position on the dAix went in the opposite direction (supine: nonpregnant 9.7 ± 6.6%, pregnant 4.4 ± 3.5%; seated: nonpregnant 7.7 ± 5.8%, pregnant 3.3 ± 2.4%, P < 0.00001 supine vs. seated in both study groups, P = 0.001 for pregnant vs. nonpregnant). CONCLUSION: Body position has a major impact on the pattern of central aortic pressure augmentation by reflected waves in healthy young women examined either during third trimester pregnancy or in the nonpregnant state.
Resumo:
Stiffness tomography is a new atomic force microscopy imaging technique that allows highlighting structures located underneath the surface of the sample. In this imaging mode, such structures are identified by investigating their mechanical properties. We present here, for the first time, a description of the use of this technique to acquire detailed stiffness maps of fixed and living macrophages. Indeed, the mechanical properties of several macrophages were studied through stiffness tomography imaging, allowing some insight of the structures lying below the cell's surface. Through these investigations, we were able to evidence the presence and properties of stiff column-like features located underneath the cell membrane. To our knowledge, this is the first evidence of the presence, underneath the cell membrane, of such stiff features, which are in dimension and form compatible with phagosomes. Moreover, by exposing the cells to cytochalasin, we were able to study the induced modifications, obtaining an indication of the location and mechanical properties of the actin cytoskeleton. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
In response to Catani et al., we show that corticospinal pathways adhere via sharp turns to two local grid orientations; that our studies have three times the diffusion resolution of those compared; and that the noted technical concerns, including crossing angles, do not challenge the evidence of mathematically specific geometric structure. Thus, the geometric thesis gives the best account of the available evidence.
Resumo:
A traditional photonic-force microscope (PFM) results in huge sets of data, which requires tedious numerical analysis. In this paper, we propose instead an analog signal processor to attain real-time capabilities while retaining the richness of the traditional PFM data. Our system is devoted to intracellular measurements and is fully interactive through the use of a haptic joystick. Using our specialized analog hardware along with a dedicated algorithm, we can extract the full 3D stiffness matrix of the optical trap in real time, including the off-diagonal cross-terms. Our system is also capable of simultaneously recording data for subsequent offline analysis. This allows us to check that a good correlation exists between the classical analysis of stiffness and our real-time measurements. We monitor the PFM beads using an optical microscope. The force-feedback mechanism of the haptic joystick helps us in interactively guiding the bead inside living cells and collecting information from its (possibly anisotropic) environment. The instantaneous stiffness measurements are also displayed in real time on a graphical user interface. The whole system has been built and is operational; here we present early results that confirm the consistency of the real-time measurements with offline computations.
Resumo:
Résumé Introduction et objectif : l'articulation du coude est vulnérable à l'enraidissement, en particulier après un traumatisme. Le but de cette étude est d'évaluer les résultats du traitement chirurgical des raideurs post-traumatiques du coude. Type d'étude : étude rétrospective de cohorte. Les patients : dix-huit patients ont été évalués cliniquement par un observateur indépendant dans un intervalle moyen de 16 mois (6 à 43) après avoir subi une arthrolyse ouverte du coude, avec comme indication opératoire une raideur post traumatique du coude. Les traumatismes subis étaient : 11 fractures isolées, 1 luxation isolée, 6 fracture-luxations complexes. Les prises en charge initiales étaient : non-chirurgicales pour 3 patients, résection de la tête radiale pour 1 patient, réduction ouverte et ostéosynthèse pour 14 patients. Les patients ont présenté des types de raideurs mixtes pour la plupart d'entre eux. Type d'intervention : arthrolyse ouverte du coude. Evaluation : la fonction du coude et la satisfaction des patients furent les principales données récoltées. Lacs de l'évaluation, les scores de SECEC (Société Européenne de Chirurgie d'Epaule et du Coude) ont été calculés. Une analyse radiologique a aussi été effectuée. Résultats : trois patients ont présenté des complications postopératoires mineures : 1 déhiscence de plaie, 1 infection sous-cutanée, 1 sérome. Aucune de ces complications n'a eu de répercussion sur le résultat final. Le gain d'amplitude articulaire moyen était de 40°, avec un gain moyen en flexion du coude de 14° (0°-45°), et de 26° en extension (5°-67°) Aucun patient n'a présenté d'instabilité du coude. Il n'y a pas eu de signe de progression d'arthrose sur les clichés radiographiques à la revue. Nous n'avons pas mis en évidence de rapport entre le type de raideur et la voie d'abord sur les résultats. Les patients ayant présentés les raideurs les plus importantes ont bénéficiés des meilleurs résultats en terme de mobilité (p<0.001). Les meilleurs résultats ont été obtenus pour les patients opérés dans la première année aptes le traumatisme initial (p=0.008). Le score SECEC moyen était de 88 points pour les coudes opérés (52-100), et de 96 points pour les coudes sains (88-100). Conclusion : l'arthrolyse ouverte confère de bons résultats pour les patients présentant une raideur post traumatique du coude. Les meilleurs résultats sont obtenus pour les patients présentant une raideur sévère, prise en charge dans l'année qui suit le traumatisme initial.
Resumo:
Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.
Resumo:
Vertebroplasty and kyphoplasty have been reported to alter the mechanical behavior of the treated and adjacent-level segments, and have been suggested to increase the risk for adjacent-level fractures. The intervertebral disc (IVD) plays an important role in the mechanical behavior of vertebral motion segments. Comparisons between normal and degenerative IVD motion segments following cement augmentation have yet to be reported. A microstructural finite element model of a degenerative IVD motion segment was constructed from micro-CT images. Microdamage within the vertebral body trabecular structure was used to simulate a slightly (I = 83.5% of intact stiffness), moderately (II = 57.8% of intact stiffness), and severely (III = 16.0% of intact stiffness) damaged motion segment. Six variable geometry single-segment cement repair strategies (models A-F) were studied at each damage level (I-III). IVD and bone stresses, and motion segment stiffness, were compared with the intact and baseline damage models (untreated), as well as, previous findings using normal IVD models with the same repair strategies. Overall, small differences were observed in motion segment stiffness and average stresses between the degenerative and normal disc repair models. We did however observe a reduction in endplate bulge and a redistribution in the microstructural tissue level stresses across both endplates and in the treated segment following early stage IVD degeneration. The cement augmentation strategy placing bone cement along the periphery of the vertebra (model E) proved to be the most advantageous in treating the degenerative IVD models by showing larger reductions in the average bone stresses (vertebral and endplate) as compared to the normal IVD models. Furthermore, only this repair strategy, and the complete cement fill strategy (model F), were able to restore the slightly damaged (I) motion segment stiffness above pre-damaged (intact) levels. Early stage IVD degeneration does not have an appreciable effect in motion segment stiffness and average stresses in the treated and adjacent-level segments following vertebroplasty and kyphoplasty. Placing bone cement in the periphery of the damaged vertebra in a degenerative IVD motion segment, minimizes load transfer, and may reduce the likelihood of adjacent-level fractures.
Resumo:
How do cells sense their own size and shape? And how does this information regulate progression of the cell cycle? Our group, in parallel to that of Paul Nurse, have recently demonstrated that fission yeast cells use a novel geometry-sensing mechanism to couple cell length perception with entry into mitosis. These rod-shaped cells measure their own length by using a medially-placed sensor, Cdr2, that reads a protein gradient emanating from cell tips, Pom1, to control entry into mitosis. Budding yeast cells use a similar molecular sensor to delay entry into mitosis in response to defects in bud morphogenesis. Metazoan cells also modulate cell proliferation in response to their own shape by sensing tension. Here I discuss the recent results obtained for the fission yeast system and compare them to the strategies used by these other organisms to perceive their own morphology.
Resumo:
The determination of the characteristics of micro-organisms in clinical specimens is essential for the rapid diagnosis and treatment of infections. A thorough investigation of the nanoscale properties of bacteria can prove to be a fundamental tool. Indeed, in the latest years, the importance of high resolution analysis of the properties of microbial cell surfaces has been increasingly recognized. Among the techniques available to observe at high resolution specific properties of microscopic samples, the Atomic Force Microscope (AFM) is the most widely used instrument capable to perform morphological and mechanical characterizations of living biological systems. Indeed, AFM can routinely study single cells in physiological conditions and can determine their mechanical properties with a nanometric resolution. Such analyses, coupled with high resolution investigation of their morphological properties, are increasingly used to characterize the state of single cells. In this work, we exploit the capabilities and peculiarities of AFM to analyze the mechanical properties of Escherichia coli in order to evidence with a high spatial resolution the mechanical properties of its structure. In particular, we will show that the bacterial membrane is not mechanically uniform, but contains stiffer areas. The force volume investigations presented in this work evidence for the first time the presence and dynamics of such structures. Such information is also coupled with a novel stiffness tomography technique, suggesting the presence of stiffer structures present underneath the membrane layer that could be associated with bacterial nucleoids.
Resumo:
OBJECTIVES: The elbow joint is vulnerable to stiffness, especially after trauma. The aim of this study was to evaluate the results of open arthrolysis for posttraumatic elbow stiffness. DESIGN: Cohort retrospective study. PATIENTS: Eighteen consecutive patients were evaluated by an independent observer at an average of 16 months (6 to 43) after open elbow arthrolysis was performed for posttraumatic stiffness. Initial traumas were: isolated fractures (11) or dislocation (1) and complex fracture-dislocations (6). Initial treatments were: nonoperative (3), radial head resection (1), and ORIF (14). Patients presented predominantly with mixed contractures (combined extrinsic and intrinsic contractures). INTERVENTION: Open elbow arthrolysis. MAIN OUTCOME MEASUREMENTS: Elbow function and patient satisfaction were the principal outcome measures. At follow-up European Society for Shoulder and Elbow Surgery (SECEC) elbow scores were calculated. RESULTS AND CONCLUSIONS: Three patients had minor postoperative complications: 1 partial wound dehiscence, 1 subcutaneous infection, and one seroma. None of these complications influenced the final result clinically. The mean total increase in range of motion was 40 degrees (13 to 112 degrees), with a mean gain in flexion of 14 degrees (0 to 45 degrees) and 26 degrees in extension (5 to 67 degrees). No patient showed signs of elbow instability. There was no radiographic evidence of osteoarthritis progression at follow-up. We did not find any correlations between the type of stiffness, the approaches used, and the results. However, patients with the greatest preoperative stiffness had significantly better improvement of mobility (P<0.001). The best results were obtained in patients who had arthrolysis done within 1 year after the initial trauma (P=0.008). The mean SECEC scores were 88 (52 to 100) for the injured elbows, and 96 (88 to 100) for the contralateral elbows. CONCLUSION: Open elbow arthrolysis for patients with posttraumatic stiffness improves joint function and provides patient satisfaction. The best results, in terms of gain of motion and patient satisfaction, were obtained in patients with severe stiffness who had operations within the first year after initial trauma.
Resumo:
This study aimed to determine changes in spring-mass model (SMM) characteristics, plantar pressures, and muscle activity induced by the repetition of sprints in soccer-specific conditions; i.e., on natural grass with soccer shoes. Thirteen soccer players performed 6 × 20 m sprints interspersed with 20 s of passive recovery. Plantar pressure distribution was recorded via an insole pressure recorder device divided into nine areas for analysis. Stride temporal parameters allowed to estimate SMM characteristics. Surface electromyographic activity was monitored for vastus lateralis, rectus femoris, and biceps femoris muscles. Sprint time, contact time, and total stride duration lengthened from the first to the last repetition (+6.7, +12.9, and +9.3%; all P < 0.05), while flight time, swing time, and stride length remained constant. Stride frequency decrease across repetitions approached significance (-6.8%; P = 0.07). No main effect of the sprint number or any significant interaction between sprint number and foot region was found for maximal force, mean force, peak pressure and mean pressure (all P > 0.05). Center of mass vertical displacement increased (P < 0.01) with time, together with unchanged (both P > 0.05) peak vertical force and leg compression. Vertical stiffness decreased (-15.9%; P < 0.05) across trials, whereas leg stiffness changes were not significant (-5.9%; P > 0.05). Changes in root mean square activity of the three tested muscles over sprint repetitions were not significant. Although repeated sprinting on natural grass with players wearing soccer boots impairs their leg-spring behavior (vertical stiffness), there is no substantial concomitant alterations in muscle activation levels or plantar pressure patterns.
Resumo:
Liver stiffness values in transient elastography (TE) have to be interpreted with caution. Steatosis, congestion, acute inflammation and extrahepatic cholestasis can indeed influence measurements. Obtained stiffness values in the cirrhotic range can also be present in the absence of fibrosis as in hepatic amyloidosis. Here we report two cases of systemic amyloidosis with hepatic involvement where high stiffness values were measured at TE. In fact, deposits of amyloid may increase the rigidity of the liver parenchyma resulting in higher liver stiffness values. Therefore, results of TE should always be interpreted in their clinical context and if inconsistent, the performance of a liver biopsy might be necessary.
Resumo:
In the latest years the importance of high resolution analysis of the microbial cell surface has been increasingly recognized. Indeed, in order to better understand bacterial physiology and achieve rapid diagnostic and treatment techniques, a thorough investigation of the surface modifications induced on bacteria by different environmental conditions or drugs is essential. Several instruments are nowadays available to observe at high resolution specific properties of microscopic samples. Among these, AFM can routinely study single cells in physiological conditions, measuring the mechanical properties of their membrane at a nanometric scale (force volume). Such analyses, coupled with high resolution investigation of their morphological properties, are increasingly used to characterize the state of single cells. In this work we exploit such technique to characterize bacterial systems. We have performed an analysis of the mechanical properties of bacteria (Escherichia coli) exposed to different conditions. Such measurements were performed on living bacteria, by changing in real-time the liquid environment: standard phosphate buffered saline, antibiotic (ampicillin) in PBS and growth medium. In particular we have focused on the determination of the membrane stiffness modifications induced by these solutions, in particular between stationary and replicating phases and what is the effect of the antibiotic on the bacterial structure.