150 resultados para Gated-SPECT

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purposes of this study were to characterize the performance of a 3-dimensional (3D) ordered-subset expectation maximization (OSEM) algorithm in the quantification of left ventricular (LV) function with (99m)Tc-labeled agent gated SPECT (G-SPECT), the QGS program, and a beating-heart phantom and to optimize the reconstruction parameters for clinical applications. METHODS: A G-SPECT image of a dynamic heart phantom simulating the beating left ventricle was acquired. The exact volumes of the phantom were known and were as follows: end-diastolic volume (EDV) of 112 mL, end-systolic volume (ESV) of 37 mL, and stroke volume (SV) of 75 mL; these volumes produced an LV ejection fraction (LVEF) of 67%. Tomographic reconstructions were obtained after 10-20 iterations (I) with 4, 8, and 16 subsets (S) at full width at half maximum (FWHM) gaussian postprocessing filter cutoff values of 8-15 mm. The QGS program was used for quantitative measurements. RESULTS: Measured values ranged from 72 to 92 mL for EDV, from 18 to 32 mL for ESV, and from 54 to 63 mL for SV, and the calculated LVEF ranged from 65% to 76%. Overall, the combination of 10 I, 8 S, and a cutoff filter value of 10 mm produced the most accurate results. The plot of the measures with respect to the expectation maximization-equivalent iterations (I x S product) revealed a bell-shaped curve for the LV volumes and a reverse distribution for the LVEF, with the best results in the intermediate range. In particular, FWHM cutoff values exceeding 10 mm affected the estimation of the LV volumes. CONCLUSION: The QGS program is able to correctly calculate the LVEF when used in association with an optimized 3D OSEM algorithm (8 S, 10 I, and FWHM of 10 mm) but underestimates the LV volumes. However, various combinations of technical parameters, including a limited range of I and S (80-160 expectation maximization-equivalent iterations) and low cutoff values (< or =10 mm) for the gaussian postprocessing filter, produced results with similar accuracies and without clinically relevant differences in the LV volumes and the estimated LVEF.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As guidelines de cardiologia nuclear europeia e americanas não são específicas na escolha dos melhores parâmetros de reconstrução de imagem a utilizar na Cintigrafia de Perfusão do Miocárdio (CPM). Assim, o presente estudo teve como objectivo estabelecer e comparar o efeito dos parâmetros quantitativos dos métodos de reconstrução: Retroprojecção Filtrada (FBP) e Ordered ‑Sub‑set Expectation Maximization (OSEM). Métodos: Foi utilizado um fantoma cardíaco, cujos valores do volume telediastólico (VTD), volume telesistólico (VTS) e fracção de ejecção ventricular esquerda (FEVE) eram conhecidos. O software Quantitative Gated SPECT/Quantitative Perfusion SPECT foi utilizado em modo semi‑automático, a fim de obter esses parâmetros quantitativos. O filtro Butterworth foi usado no FBP com as frequências de corte entre 0,2 e 0,8 ciclos/pixel combinadas com as ordens de 5, 10, 15 e 20. Na reconstrução OSEM, foram utilizados os subconjuntos 2, 4, 6, 8, 10, 12 e 16, combinados com os números de iterações de 2, 4, 6, 8, 10, 12, 16, 32 e 64. Durante a reconstrução OSEM efectuou‑se uma outra reconstrução baseada no número de iterações equivalentes - Expectation‑Maximization (EM) 12, 14, 16, 18, 20, 22, 26, 28, 30 e 32. Resultados: Após a reconstrução com FBP verificou‑se que os valores de VTD e VTS aumentavam com o aumento da frequência de corte, enquanto o valor da FEVE diminui. Esse mesmo padrão é verificado na reconstrução OSEM. No entanto, com OSEM há uma estimativa mais precisa dos parâmetros quantitativos, especialmente com as combinações 2I × 10S e 12S × 2I. Conclusão: A reconstrução OSEM apresenta uma melhor estimativa dos parâmetros quantitativos e uma melhor qualidade de imagem do que a reconstrução com FBP. Este estudo recomenda o uso de 2 iterações com 10 ou 12 subconjuntos para a reconstrução OSEM e uma frequência de corte de 0,5 ciclos/pixel com as ordens 5, 10 ou 15 para a reconstrução com FBP como a melhor estimativa para a quantificação da FEVE através da CPM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The results of several large multicenter CMR studies were reported in 2012, thus, constantly corroborating the evidence on CMR performance. In this review, we present results of the MR-IMPACT programme and the CE-MARC study, which demonstrated the superiority of perfusion-CMR over gated SPECT for the workup of suspected CAD, the currently available data from the European CMR registry, comprising almost 30,000 patients from 57 participating centers in 15 European countries, and finally, the results of the Advisa-MRI study, which documented the safety of a MRI-compatible pacemaker system. These large trials and others set the basis for the recommendations in the new European guidelines on heart failure to use CMR as a first line method if echocardiographic quality is inadequate or the etiology of heart failure is unclear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Voltage-gated sodium channels (Nav1.x) are important players in chronic pain. A particular interest has grown in Nav1.7, expressed in nociceptors, since mutations in its gene are associated to two inherited pain syndromes or insensitivity to pain. Rufinamide, a drug used to treat refractory epilepsy such as the Lennox-Gastaut syndrome, has been shown to reduce the number of action potentials in cortical neurons without completely blocking Na channels. Aim: The goal of this study was to investigate the effect of rufinamide on Nav1.7 current. Methods and results: Whole-cell patch clamp experiments were performed using HEK293 cells stably expressing Nav1.7. Rufinamide significantly decreased peak sodium current by 28.3, 21.2 and 12.5% at concentrations of 500, 100 and 50μM respectively (precise EC50 could not be calculated since higher rufinamide concentrations could not be achieved in physiological buffer solution). No significant difference on the V1/2 of voltage-dependence of activation was seen; however a shift in the steady-state inactivation curve was observed (-82.6 mV to -88.8 mV and -81.8 to -87.6 mV for 50 and 100 μM rufinamide respectively, p <0.005). Frequency-dependent inhibition of Nav1.7 was also influenced by the drug. One hundred μM rufinamide reduced the peak sodium current (in % of the peak current taken at the first sweep of a train of 50) from 90.8 to 80.8% (5Hz), 88.7 to 71.8% (10 Hz), 69.1 to 49.2% (25 Hz) and 22.3 to 9.8% (50 Hz) (all p <0.05). Onset of fast inactivation was not influenced by the drug since no difference in the time constant of current decay was observed. Conclusion: In the concentration range of plasma level in human treated for epilepsy, 15 μM, rufinamide only minimally blocks Nav1.7. However, it stabilizes the inactivated state and exerts frequencydependent inhibition of Nav1.7. These pharmacological properties may be of use in reducing ectopic discharges as a causal and symptom related contributor of neuropathic pain syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim: Neuropathic pain (NP) is a frequent and disabling disorder occurring as a consequence of a direct lesion of the nervous system and recurrently associated with a positive shift toward nervous system excitability. Peripheral nerve activity is mainly carried by voltage-gated sodium channels (VGSC), with Nav1.7 isoform being an important candidate since loss of function mutations of its gene is associated with congenital inability to experience pain. Interestingly, ubiquitin ligases from the Nedd4 family are well known proteins that regulate the turnover of many membrane proteins such as VGSC and we showed Nedd2-2 is downregualted in experimental models of chronic pain. The aim of this study was to investigate the importance of Nedd4-2 in the modulation of Nav1.7 at the membrane. Methods: In vitro: whole cell patch clamp on HEK293 cell line stably expressing Nav1.7 was used to record sodium currents (INa), where the peak current of INa reflects the quantity of functional Nav1.7 expressed at the membrane. The possibility that Nedd4-2 modulates the currents was assessed by investigating the effect of its cotransfection on INa. Biotinylation of cell surface was used to isolate membrane-targeted Nav1.7. Furthermore, as the interaction between Nedd4-2 and Nav isoforms was previously reported to rely on an xPPxYx sequence (PY-motif), we mutated this latter to study its impact in the specific interaction between Nav1.7 and Nedd4-2. GST-fusion proteins composed of the Nav1.7 c terminal 66 amino acids (wild-type or PY mutated) and GST were used to pull-down Nedd4-2 from lysates. Results: Co-transfection of Nav1.7 with Nedd4-2 reduced the Nav1.7 current amplitude by ~80% (n = 36, p <0.001), without modifying the biophysical properties of INa. In addition, we show that the quantity of Nav1.7 at the membrane was decreased when Nedd4-2 was present. This effect was dependent on the PY-motif since mutations in this sequence abolished the down-regulatory effect of Nedd4-2. The importance of this motif was further confirmed by pull down experiments since the PY mutant completely eliminate the interaction with Nedd4-2. Perspectives: Altogether, these results point to the importance of Nedd4-2 as a Nav1.7 regulator through cell surface modulation of this sodium channel. Further experiments in freshly dissociated neurons from wild type and Scn1bflox/Nedd4-2Cre mice are needed to confirm in vivo these preliminary data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractAcidosis is encountered during tissue inflammation and triggers pain in humans. H+-gated ion channels are expressed at high levels in sensory neurons of the peripheral nervous system. Ion channels from two different families present the required pH sensitivity to detect the acidosis associated with peripheral inflammation: Acid-Sensing Ion Channels (ASICs) and the Transient Receptor Potential Vanilloid-1 (TRPV1) channel.ASICs are members of the Degenerin/Epithelial Na+ Channel family of ion channels. Six ASIC subunits have been identified in mammals (ASICla, -lb, -2a, -2b, -3 and -4). ASICs form In-activated voltage-insensitive homo- or heterotrimeric Na+ channels. TRPV1 is a member of the TRP family of ion channels and forms non-selective cation channels that mediate a sustained current. TRPV1 is activated by H+, heat (T>43°C), lipids, capsaicin, voltage and other stimuli. A stimulus can increase TRPV1 response to a different stimulus. For example H+ can shift the capsaicin concentration dependence of TRPV1 to lower values. ASICs and TRPV1 have been shown to be involved in inflammatory pain. Using the patch-clamp technique, we studied different aspects of the function of ASICs and TRPV1 in the physiological context of pain.In the first part of this thesis, we characterize the effect of a temperature increase from 25 to 35°C on the function of ASICs and TRPV1 in transfected CHO cells and primary cultures of rat DRG sensory neurons. ASICs give rise to transient currents while TRPV1 mediates a sustained current. In addition, ASICs and TRPV1 respond to H+ with distinct pH dependences. We assess the relative contribution of ASICs and TRPV1 to H+-evoked electrical signaling in rat DRG neurons and we conclude that ASICs are the most important pH sensors in the pH range 7.4 to 6.0 at 35°C in sensory neurons.ASICs and TRPV1 are expressed in the epithelium lining the lumen of the bladder (urothelium). The Bladder Pain Syndrome/Interstitial Cystitis (BPS/IC) is a painful condition associated with a dysfunction of the urothelial barrier and with inflammation. In the second part of this thesis, we show that human urothelial cells -the cell line TEU2 and primary cultures of human bladder urothelium- express functional ASICs but no functional TRPV1 channels. In addition, we show that the levels of ASIC2 and ASIC3 mRNA are increased in the urothelium of patients suffering from BPS/IC. These data suggest that ASICs are involved in the pathology of BPS/IC.Finally, we demonstrate that APETx2 inhibits the sensory neuron specific voltage-dependent Na+ channel Nav1.8. APETx2 was previously shown to inhibit homo- or heterotrimeric ASIC3- containing channels with IC5o from 0.08 to 1 μΜ. We show that APETx2 also inhibits Nav1.8 with an ICsoof «2.6 μΜ. APETx2 reduces the maximal conductance and induces a depolarizing shift in the voltage dependence of activation of Nav1.8. In current-clamp experiments, APETx2 reduces the number of action potentials (APs) evoked by a current ramp. Nav1.8 mediates most of the current during the AP upstroke and has been shown to be an important mediator of inflammatory pain. The fact that APETx2 inhibits two ion channels involved in inflammatory pain suggests that APETx2 or derivatives may represent novel analgesic compounds.RésuméL'acidose tissulaire est observée durant l'inflammation et entraine la douleur chez l'humain. Des canaux ioniques activés par les protons (H+) sont fortement exprimés dans les neurones sensoriels du système nerveux périphérique. De ceux-ci, les Acid-Sensing Ion Channels [ASICs) et Transient Receptor Potential Vanilloid-1 (TRPV1) présentent une sensibilité adéquate à l'acidité pour servir de détecteurs d'acidose.Les ASICs sont membres de la famille Degenerin/Epithelial Na* Channel. Six sous-unités ASIC ont été identifiées chez les mammifères (ASICla, -lb, -2a, -2b, -3 et -4). Les ASICs forment des canaux sélectifs au Na\ insensibles au voltage et activés par les H+. Les canaux fonctionnels sont des homo- ou hétérotrimères de sous-unités ASIC. TRPV1 est un membre de la famille TRP de canaux ioniques. Les canaux TRPV1 sont activés par les H+, la chaleur (T>43°Ç), les lipides, la capsaicine, le voltage et d'autres stimulus. L'activation de TRPV1 entraine un courant soutenu non-sélectif. Un stimulus peut augmenter la réponse de TRPV1 à un autre stimulus. Les H+ peuvent, par exemple, induire un décalage vers des valeurs plus faibles de la courbe de dépendance à la concentration de TRPV1 pour la capsaicine. Il a été démontré que les ASICs et TRPV1 sont impliqués dans la douleur inflammatoire. En utilisant la technique du patch-clamp, nous avons étudié différents aspects de la fonction des ASICs et de TRPV1 dans des contextes associés à la douleur.Dans la première partie de cette thèse, nous caractérisons l'effet d'une augmentation de température de 25 à 35°C sur la fonction des canaux ASICs et TRPV1, dans des cellules CHO transfectées et dans des cultures primaires de neurones sensoriels (DRG) de rat. L'activation des ASICs entraine l'apparition d'un courant transitoire tandis que l'activation de TRPV1 entraine un courant soutenu. De plus, les ASICs et TRPV1 possèdent des dépendances au pH différentes. Nous évaluons la contribution relative des ASICs et de TRPV1 au signalement électrique induit par les H+ et nous concluons que les ASICs sont les senseurs d'acidité les plus importants dans les neurones sensoriels, dans le domaine de pH de 7.4 à 6.0, à température corporelle.Les ASICs et TRPV1 sont exprimés dans l'épithélium recouvrant l'intérieur de la vessie (l'urothélium). Le Bladder Pain Syndrome/Interstitial Cystitis (BPS/IC) est une condition médicale douloureuse associée à une dysfonction de la barrière urothéliale et à une inflammation. Dans la seconde partie de cette thèse, nous démontrons que des cellules urothéliales (de la lignée cellulaire TEU2) et des cellules provenant de cultures primaires d'épithéliums de vessies humaines expriment des canaux ASIC fonctionnels mais pas de TRPV1 fonctionnels. De plus, nous montrons que le niveau d'expression de ASIC2 et -3 est augmenté dans l'urothélium de la vessie de patients souffrant de BPS/IC. Ces données suggèrent que les ASICs sont impliqués dans la pathologie BPS/IC.Pour finir, nous démontrons que la toxine APETx2 inhibe le canal spécifique aux neurones sensoriels Nav1.8, un membre de la famille des canaux sodiques dépendants du potentiel. Il a été démontré précédemment que la toxine APETx2 inhibe les canaux contenant une ou plusieurs sous-unités ASIC3 avec un ICso entre 0.08 et 1 μΜ. Nous montrons que la toxine APETx2 inhibe Nav1.8 avec un IC50 de «2.6 μΜ. La toxine APETx2 réduit la conductance maximale et induit un décalage de la dépendance au potentiel de Nav1.8 vers des valeurs plus positives. Dans des expériences de courant imposé sur des neurones sensoriels, la toxine APETx2 réduit le nombre de potentiels d'action induits par une rampe de courant. Nav1.8 est responsable de la majeure partie du courant durant la phase ascendante du potentiel d'action et a été démontré comme étant un médiateur important de la douleur inflammatoire. L'inhibition de deux types de canaux, impliqués dans la douleurs inflammatoire, par la toxine APETx2, suggère que cette dernière ou ses dérivés représentent des composés analgésiques prometteurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Recent developments of MR imaging equipment enabled high-quality steady state-free-precession (Balanced FFE, True-FISP) MR-imaging with a substantial 'T2 like' contrast, resulting in a high signal intensity of the blood-pool without the application of exogenous contrast agents. It is hypothesized that Balanced-FFE may be valuable for contrast enhancement in 3D free-breathing coronary MRA. MATERIALS AND METHODS: Navigator-gated free-breathing cardiac triggered coronary MRA was performed in 10 healthy adult subjects and three patients with radiograph defined coronary artery disease using a segmented k-space 3D Balanced FFE imaging sequence. RESULTS: High contrast-to-noise ratio between the blood-pool and the myocardium (29 +/- 8) and long segment visualization of both coronary arteries could be obtained in about 5 minutes during free breathing using the present navigator-gated Balanced-FFE coronary MRA approach. First patient results demonstrated successful display of coronary artery stenoses. CONCLUSION: Balanced FFE offers a potential alternative for endogenous contrast enhancement in navigator-gated free-breathing 3D coronary MRA. The obtained results together with the relatively short scanning time warrant further studies in larger patient collectives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voltage-gated Na(+) channels (NaV channels) are specifically blocked by guanidinium toxins such as tetrodotoxin (TTX) and saxitoxin (STX) with nanomolar to micromolar affinity depending on key amino acid substitutions in the outer vestibule of the channel that vary with NaV gene isoforms. All NaV channels that have been studied exhibit a use-dependent enhancement of TTX/STX affinity when the channel is stimulated with brief repetitive voltage depolarizations from a hyperpolarized starting voltage. Two models have been proposed to explain the mechanism of TTX/STX use dependence: a conformational mechanism and a trapped ion mechanism. In this study, we used selectivity filter mutations (K1237R, K1237A, and K1237H) of the rat muscle NaV1.4 channel that are known to alter ionic selectivity and Ca(2+) permeability to test the trapped ion mechanism, which attributes use-dependent enhancement of toxin affinity to electrostatic repulsion between the bound toxin and Ca(2+) or Na(+) ions trapped inside the channel vestibule in the closed state. Our results indicate that TTX/STX use dependence is not relieved by mutations that enhance Ca(2+) permeability, suggesting that ion-toxin repulsion is not the primary factor that determines use dependence. Evidence now favors the idea that TTX/STX use dependence arises from conformational coupling of the voltage sensor domain or domains with residues in the toxin-binding site that are also involved in slow inactivation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Typically at dawn on a hot summer day, land plants need precise molecular thermometers to sense harmless increments in the ambient temperature to induce a timely heat shock response (HSR) and accumulate protective heat shock proteins in anticipation of harmful temperatures at mid-day. Here, we found that the cyclic nucleotide gated calcium channel (CNGC) CNGCb gene from Physcomitrella patens and its Arabidopsis thaliana ortholog CNGC2, encode a component of cyclic nucleotide gated Ca(2+) channels that act as the primary thermosensors of land plant cells. Disruption of CNGCb or CNGC2 produced a hyper-thermosensitive phenotype, giving rise to an HSR and acquired thermotolerance at significantly milder heat-priming treatments than in wild-type plants. In an aequorin-expressing moss, CNGCb loss-of-function caused a hyper-thermoresponsive Ca(2+) influx and altered Ca(2+) signaling. Patch clamp recordings on moss protoplasts showed the presence of three distinct thermoresponsive Ca(2+) channels in wild-type cells. Deletion of CNGCb led to a total absence of one and increased the open probability of the remaining two thermoresponsive Ca(2+) channels. Thus, CNGC2 and CNGCb are expected to form heteromeric Ca(2+) channels with other related CNGCs. These channels in the plasma membrane respond to increments in the ambient temperature by triggering an optimal HSR, leading to the onset of plant acquired thermotolerance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Mutations in the SCN9A gene cause chronic pain and pain insensitivity syndromes. We aimed to study clinical, genetic, and electrophysiological features of paroxysmal extreme pain disorder (PEPD) caused by a novel SCN9A mutation. METHODS: Description of a 4-generation family suffering from PEPD with clinical, genetic and electrophysiological studies including patch clamp experiments assessing response to drug and temperature. RESULTS: The family was clinically comparable to those reported previously with the exception of a favorable effect of cold exposure and a lack of drug efficacy including with carbamazepine, a proposed treatment for PEPD. A novel p.L1612P mutation in the Nav1.7 voltage-gated sodium channel was found in the four affected family members tested. Electrophysiologically the mutation substantially depolarized the steady-state inactivation curve (V1/2 from -61.8 ± 4.5 mV to -30.9 ± 2.2 mV, n = 4 and 7, P < 0.001), significantly increased ramp current (from 1.8% to 3.4%, n = 10 and 12) and shortened recovery from inactivation (from 7.2 ± 5.6 ms to 2.2 ± 1.5 ms, n = 11 and 10). However, there was no persistent current. Cold exposure reduced peak current and prolonged recovery from inactivation in wild-type and mutated channels. Amitriptyline only slightly corrected the steady-state inactivation shift of the mutated channel, which is consistent with the lack of clinical benefit. CONCLUSIONS: The novel p.L1612P Nav1.7 mutation expands the PEPD spectrum with a unique combination of clinical symptoms and electrophysiological properties. Symptoms are partially responsive to temperature but not to drug therapy. In vitro trials of sodium channel blockers or temperature dependence might help predict treatment efficacy in PEPD.