141 resultados para Gastric foreign bodies
em Université de Lausanne, Switzerland
Resumo:
Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.
Resumo:
BACKGROUND: Persisting metallic intraocular foreign bodies (IOFB) with a ferrous content have been associated with ocular siderosis and retinal degeneration. We describe two patients in whom a metallic IOFB containing iron was left embedded for many years in the choroid and sclera after having penetrated through the vitreous and the retina. HISTORY AND SIGNS: Two male patients, aged 41 and 48 years, presented with a metallic IOFB sustained during a work accident involving metal tools. THERAPY AND OUTCOME: For the first patient it was deemed unwise to operate, as the IOFB was also lodged very deeply in the choroid and sclera in the inferior temporal quadrant. The second patient underwent pars plana vitrectomy, but the IOFB could not be removed surgically as it was too deeply embedded in the sclera and choroid. After a period of 6 years (Case 1) and 4 years (Case 2) of follow-up, visual acuity remained at 1.0 and the IOFB was encased in a fibrotic capsule in both cases. Full-field and multifocal electroretinograms showed an inter-ocular asymmetry at baseline, which remained stable during the follow-up. CONCLUSIONS: Ocular siderosis may not develop in patients with a deeply embedded metallic IOFB. Regular monitoring of both visual function and the electroretinogram is mandatory when the IOFB is left inside the eye.
Resumo:
OBJECTIVES: The presence of intravascular foreign bodies is underreported in the literature and is more commonly encountered in clinical practice. We report on a case where an attempt to position a carotid stent resulted in misdeployment of the stent in the femoral artery and its surgical removal. METHODS: A 63-year-old patient admitted to hospital for cerebral stroke underwent thrombolysis for occlusive dissection of right carotid artery and was transferred to our hospital for additional thrombo-aspiration and carotid stenting. RESULTS: The carotid stent was misdeployed incompletely in the femoral artery and had to be removed surgically. CONCLUSIONS: Appropriate knowledge of intravascular migration and deployment failure management should be considered as important as the optimal device deployment.
Resumo:
OBJECTIVE: As part of the WHO ICD-11 development initiative, the Topic Advisory Group on Quality and Safety explores meta-features of morbidity data sets, such as the optimal number of secondary diagnosis fields. DESIGN: The Health Care Quality Indicators Project of the Organization for Economic Co-Operation and Development collected Patient Safety Indicator (PSI) information from administrative hospital data of 19-20 countries in 2009 and 2011. We investigated whether three countries that expanded their data systems to include more secondary diagnosis fields showed increased PSI rates compared with six countries that did not. Furthermore, administrative hospital data from six of these countries and two American states, California (2011) and Florida (2010), were analysed for distributions of coded patient safety events across diagnosis fields. RESULTS: Among the participating countries, increasing the number of diagnosis fields was not associated with any overall increase in PSI rates. However, high proportions of PSI-related diagnoses appeared beyond the sixth secondary diagnosis field. The distribution of three PSI-related ICD codes was similar in California and Florida: 89-90% of central venous catheter infections and 97-99% of retained foreign bodies and accidental punctures or lacerations were captured within 15 secondary diagnosis fields. CONCLUSIONS: Six to nine secondary diagnosis fields are inadequate for comparing complication rates using hospital administrative data; at least 15 (and perhaps more with ICD-11) are recommended to fully characterize clinical outcomes. Increasing the number of fields should improve the international and intra-national comparability of data for epidemiologic and health services research, utilization analyses and quality of care assessment.
Resumo:
BACKGROUND: Electrophysiological cardiac devices are increasingly used. The frequency of subclinical infection is unknown. We investigated all explanted devices using sonication, a method for detection of microbial biofilms on foreign bodies. METHODS AND RESULTS: Consecutive patients in whom cardiac pacemakers and implantable cardioverter/defibrillators were removed at our institution between October 2007 and December 2008 were prospectively included. Devices (generator and/or leads) were aseptically removed and sonicated, and the resulting sonication fluid was cultured. In parallel, conventional swabs of the generator pouch were performed. A total of 121 removed devices (68 pacemakers, 53 implantable cardioverter/defibrillators) were included. The reasons for removal were insufficient battery charge (n=102), device upgrading (n=9), device dysfunction (n=4), or infection (n=6). In 115 episodes (95%) without clinical evidence of infection, 44 (38%) grew bacteria in sonication fluid, including Propionibacterium acnes (n=27), coagulase-negative staphylococci (n=11), Gram-positive anaerobe cocci (n=3), Gram-positive anaerobe rods (n=1), Gram-negative rods (n=1), and mixed bacteria (n=1). In 21 of 44 sonication-positive episodes, bacterial counts were significant (>or=10 colony-forming units/mL of sonication fluid). In 26 sterilized controls, sonication cultures remained negative in 25 cases (96%). In 112 cases without clinical infection, conventional swab cultures were performed: 30 cultures (27%) were positive, and 18 (60%) were concordant with sonication fluid cultures. Six devices and leads were removed because of infection, growing Staphylococcus aureus, Streptococcus mitis, and coagulase-negative staphylococci in 6 sonication fluid cultures and 4 conventional swab cultures. CONCLUSIONS: Bacteria can colonize cardiac electrophysiological devices without clinical signs of infection.
Resumo:
PURPOSE: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. RESULTS: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). CONCLUSION: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.
Resumo:
PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.
Resumo:
All manner of foreign bodies have been extracted from the bladder. Introduction into the bladder may be through self-insertion, iatrogenic means or migration from adjacent organs. Extraction should be tailored according to the nature of the foreign body and should minimise bladder and urethral trauma. We report a case of a bullet injury to the bladder, which finally presented as a gross hematuria after remaining asymptomatic for four years. We present here an alternative to suprapubic cystostomy with a large bladder foreign body treated via a combined transurethral unroofing followed by removal using a grasper passed through a suprapubic laparoscopic port.
Resumo:
A young patient suffering from schizophrenia had intense headaches and photophobia which were induced by intra-ocular injections of mercury. The clinical diagnosis was established once foreign bodies were visualized on regular X-rays of the patients skull. The mercury intoxication in combination with the secondary irreversible lesions to the eyes necessitated a bilateral enucleation and the use of a chelating treatment with sodium-dimercapto-1-propane sulfate (DMP). Automutilation is a very rare and dramatic complication of schizophrenia. The psychiatric handling and meaning of such dramatic automutilation is discussed in this case report together with a recent review of the toxicologic treatment of mercury intoxication in humans.
Resumo:
Introduction. Selective embolization of the left-gastric artery (LGA) reduces levels of ghrelin and achieves significant short-term weight loss. However, embolization of the LGA would prevent the performance of bariatric procedures because the high-risk leakage area (gastroesophageal junction [GEJ]) would be devascularized. Aim. To assess an alternative vascular approach to the modulation of ghrelin levels and generate a blood flow manipulation, consequently increasing the vascular supply to the GEJ. Materials and methods. A total of 6 pigs underwent a laparoscopic clipping of the left gastroepiploic artery. Preoperative and postoperative CT angiographies were performed. Ghrelin levels were assessed perioperatively and then once per week for 3 weeks. Reactive oxygen species (ROS; expressed as ROS/mg of dry weight [DW]), mitochondria respiratory rate, and capillary lactates were assessed before and 1 hour after clipping (T0 and T1) and after 3 weeks of survival (T2), on seromuscular biopsies. A celiac trunk angiography was performed at 3 weeks. Results. Mean (±standard deviation) ghrelin levels were significantly reduced 1 hour after clipping (1902 ± 307.8 pg/mL vs 1084 ± 680.0; P = .04) and at 3 weeks (954.5 ± 473.2 pg/mL; P = .01). Mean ROS levels were statistically significantly decreased at the cardia at T2 when compared with T0 (0.018 ± 0.006 mg/DW vs 0.02957 ± 0.0096 mg/DW; P = .01) and T1 (0.0376 ± 0.008mg/DW; P = .007). Capillary lactates were significantly decreased after 3 weeks, and the mitochondria respiratory rate remained constant over time at the cardia and pylorus, showing significant regional differences. Conclusions. Manipulation of the gastric flow targeting the gastroepiploic arcade induces ghrelin reduction. An endovascular approach is currently under evaluation.
Augmentation cystoplasty using pedicled and de-epithelialized gastric patches in the mini-pig model.
Resumo:
PURPOSE: The most common methods of bladder augmentation are gastrocystoplasty and enterocystoplasty. Gastrocystoplasty is advantageous due to minimal mucous secretion and a well developed muscular wall as well as good urodynamic properties of the patch. However, the permanent contact of urine with the gastric mucosa is not free of complications. We report the urodynamic, macroscopic and histological outcomes of a pedicled de-epithelialized gastric patch incorporated in the bladder. We compared the results to those of our previous study, which sought to analyze these techniques of patch coverage using sigmoid patches. MATERIALS AND METHODS: We performed 20 augmentation cystoplasties in the mini-pig model using a pedicled de-epithelialized gastric patch and 5 techniques of patch coverage. RESULTS: Three months after surgery all bladders had an increase in volume except those in which the auto-augmentation technique was used. However, all gastric patches were smaller compared to preoperative size. Many had irregular fibrosed inner surfaces and histological evaluation revealed a fibrosed newly formed submucosal layer with a complete urothelial coverage in every patch. No gastric mucosal remnant was found. CONCLUSIONS: De-epithelialized gastrocystoplasty is an attractive procedure that can increase bladder capacity as well as provide a complete urothelial lining without mucosal remnants. However, the success of this procedure seems to be limited by increased morbidity and fibrotic changes, and decreased surface of the patch.