42 resultados para Gardens, Miniature
em Université de Lausanne, Switzerland
Resumo:
Miniature is an extracellular zona pellucida domain-containing protein, required for flattening of pupal wing epithelia in Drosophila. Here, we show that Miniature also plays an important role in the post-eclosion wing maturation processes triggered by the neurohormone bursicon. Wing expansion and epithelial apoptosis are drastically delayed in miniature loss-of-function mutants, and sped up upon overexpression of the protein in wings. Miniature acts upstream from the heterotrimeric Gs protein transducing the bursicon signal in wing epithelia. We propose that Miniature interacts with bursicon and regulates its diffusion through or stability within the wing tissue.
Resumo:
Miniature diffusion size classifiers (miniDiSC) are novel handheld devices to measure ultrafine particles (UFP). UFP have been linked to the development of cardiovascular and pulmonary diseases; thus, detection and quantification of these particles are important for evaluating their potential health hazards. As part of the UFP exposure assessments of highwaymaintenance workers in western Switzerland, we compared a miniDiSC with a portable condensation particle counter (P-TRAK). In addition, we performed stationary measurements with a miniDiSC and a scanning mobility particle sizer (SMPS) at a site immediately adjacent to a highway. Measurements with miniDiSC and P-TRAK correlated well (correlation of r = 0.84) but average particle numbers of the miniDiSC were 30%âeuro"60% higher. This difference was significantly increased for mean particle diameters below 40 nm. The correlation between theminiDiSC and the SMPSduring stationary measurements was very high (r = 0.98) although particle numbers from the miniDiSC were 30% lower. Differences between the three devices were attributed to the different cutoff diameters for detection. Correction for this size dependent effect led to very similar results across all counters.We did not observe any significant influence of other particle characteristics. Our results suggest that the miniDiSC provides accurate particle number concentrations and geometric mean diameters at traffic-influenced sites, making it a useful tool for personal exposure assessment in such settings.
Resumo:
Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.
Resumo:
This article analyses how Radha was depicted in miniature paintings between the 16th and 19th century in North India. Interrogating the link between text and image, contrasting poetry, style and historical settings with the visual representations of this central figure, my reflections focus on the changing nature of Radha. Through various examples from miniature paintings of different periods and schools, this article analyses the way the rich personality of Radha was transposed into images. In order to stress the changes brought to this female figure, I compare her to Krishna, the masculine figure who is always at her side. The main goal of the article is to show the normative power of images on the figure of Radha, with normativity being understood as the simplification, iconisation, aestheticisation and stereotypification of a figure with polysemous references.
Resumo:
Study Objectives: Interspecific variation in sleep measured in captivity correlates with various physiological and environmental factors, including estimates of predation risk in the wild. However, it remains unclear whether prior comparative studies have been confounded by the captive recording environment. Herein we examine the impact of predation pressure on sleep in sloths living in the wild. Design: Comparison of two closely related sloth species, one exposed to predation and one free from predation. Setting: Panamanian mainland rainforest (predators present) and island mangrove (predators absent). Participants: Mainland (Bradypus variegatus, 5 males and 4 females) and island (Bradypus pygmaeus, 6 males) sloths. Interventions: None. Measurements and Results: EEG and EMG activity were recorded using a miniature data logger. Although both species spent between 9 and 10 hours per day sleeping, the mainland sloths showed a preference for sleeping at night, whereas island sloths showed no preference for sleeping during the day or night. EEG activity during NREM sleep showed lower low-frequency power, and increased spindle and higher frequency power in island sloths when compared to mainland sloths. Conclusions: In sloths sleeping in the wild, predation pressure influenced the timing of sleep, but not the amount of time spent asleep. The preference for sleeping at night in mainland sloths may be a strategy to avoid detection by nocturnal cats. The pronounced differences in the NREM sleep EEG spectrum remain unexplained, but might be related to genetic or environmental factors.
Resumo:
Introduction: Coordination is a strategy chosen by the central nervous system to control the movements and maintain stability during gait. Coordinated multi-joint movements require a complex interaction between nervous outputs, biomechanical constraints, and pro-prioception. Quantitatively understanding and modeling gait coordination still remain a challenge. Surgeons lack a way to model and appreciate the coordination of patients before and after surgery of the lower limbs. Patients alter their gait patterns and their kinematic synergies when they walk faster or slower than normal speed to maintain their stability and minimize the energy cost of locomotion. The goal of this study was to provide a dynamical system approach to quantitatively describe human gait coordination and apply it to patients before and after total knee arthroplasty. Methods: A new method of quantitative analysis of interjoint coordination during gait was designed, providing a general model to capture the whole dynamics and showing the kinematic synergies at various walking speeds. The proposed model imposed a relationship among lower limb joint angles (hips and knees) to parameterize the dynamics of locomotion of each individual. An integration of different analysis tools such as Harmonic analysis, Principal Component Analysis, and Artificial Neural Network helped overcome high-dimensionality, temporal dependence, and non-linear relationships of the gait patterns. Ten patients were studied using an ambulatory gait device (Physilog®). Each participant was asked to perform two walking trials of 30m long at 3 different speeds and to complete an EQ-5D questionnaire, a WOMAC and Knee Society Score. Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. The outcomes of the eight patients undergoing total knee arthroplasty, recorded pre-operatively and post-operatively at 6 weeks, 3 months, 6 months and 1 year were compared to 2 age-matched healthy subjects. Results: The new method provided coordination scores at various walking speeds, ranged between 0 and 10. It determined the overall coordination of the lower limbs as well as the contribution of each joint to the total coordination. The difference between the pre-operative and post-operative coordination values were correlated with the improvements of the subjective outcome scores. Although the study group was small, the results showed a new way to objectively quantify gait coordination of patients undergoing total knee arthroplasty, using only portable body-fixed sensors. Conclusion: A new method for objective gait coordination analysis has been developed with very encouraging results regarding the objective outcome of lower limb surgery.
Augmentation cystoplasty using pedicled and de-epithelialized gastric patches in the mini-pig model.
Resumo:
PURPOSE: The most common methods of bladder augmentation are gastrocystoplasty and enterocystoplasty. Gastrocystoplasty is advantageous due to minimal mucous secretion and a well developed muscular wall as well as good urodynamic properties of the patch. However, the permanent contact of urine with the gastric mucosa is not free of complications. We report the urodynamic, macroscopic and histological outcomes of a pedicled de-epithelialized gastric patch incorporated in the bladder. We compared the results to those of our previous study, which sought to analyze these techniques of patch coverage using sigmoid patches. MATERIALS AND METHODS: We performed 20 augmentation cystoplasties in the mini-pig model using a pedicled de-epithelialized gastric patch and 5 techniques of patch coverage. RESULTS: Three months after surgery all bladders had an increase in volume except those in which the auto-augmentation technique was used. However, all gastric patches were smaller compared to preoperative size. Many had irregular fibrosed inner surfaces and histological evaluation revealed a fibrosed newly formed submucosal layer with a complete urothelial coverage in every patch. No gastric mucosal remnant was found. CONCLUSIONS: De-epithelialized gastrocystoplasty is an attractive procedure that can increase bladder capacity as well as provide a complete urothelial lining without mucosal remnants. However, the success of this procedure seems to be limited by increased morbidity and fibrotic changes, and decreased surface of the patch.
Resumo:
Introduction: In order to improve safety of pedicle screw placement several techniques have been developed. More recently robotically assisted pedicle insertion has been introduced aiming at increasing accuracy. The aim of this study was to compare this new technique with the two main pedicle insertion techniques in our unit namely fluoroscopically assisted vs EMG aided insertion. Material and methods: A total of 382 screws (78 thoracic,304 lumbar) were introduced in 64 patients (m/f = 1.37, equally distributed between insertion technique groups) by a single experienced spinal surgeon. From those, 64 (10 thoracic, 54 lumbar) were introduced in 11 patients using a miniature robotic device based on pre operative CT images under fluoroscopic control. 142 (4 thoracic, 138 lumbar) screws were introduced using lateral fluoroscopy in 27 patients while 176 (64 thoracic, 112 lumbar) screws in 26 patients were inserted using both fluoroscopy and EMG monitoring. There was no difference in the distribution of scoliotic spines between the 3 groups (n = 13). Screw position was assessed by an independent observer on CTs in axial, sagittal and coronal planes using the Rampersaud A to D classification. Data of lumbar and thoracic screws were processed separately as well as data obtained from axial, sagittal and coronal CT planes. Results: Intra- and interobserver reliability of the Rampersaud classification was moderate, (0.35 and 0.45 respectively) being the least good on axial plane. The total number of misplaced screws (C&D grades) was generally low (12 thoracic and 12 lumbar screws). Misplacement rates were same in straight and scoliotic spines. The only difference in misplacement rates was observed on axial and coronal images in the EMG assisted thoracic screw group with a higher proportion of C or D grades (p <0.05) in that group. Recorded compound muscle action potentials (CMAP) values of the inserted screws were 30.4 mA for the robot and 24.9mA for the freehand technique with a CI of 3.8 of the mean difference of 5.5 mA. Discussion: Robotic placement did improve the placement of thoracic screws but not that of lumbar screws possibly because our misplacement rates in general near that of published navigation series. Robotically assisted spine surgery might therefore enhance the safety of screw placement in particular in training settings were different users at various stages of their learning curve are involved in pedicle instrumentation.
Resumo:
Purpose of the study: Reconstruction of the anterior cruciate ligament (ACL) controls laxity but does not enable restoration of strictly normal 3D kinematics. The purpose of this study was to compare the kinematics of the pathological knee with that of the healthy knee after ACL plasty. This study applied a new ambulatory system using miniature captors. Material and method: Five patients with an isolated injury of the ACL participated in this study. The patients were assessed after injury (T1), at five months (T2), and at 14 months (T3) after surgery. The assessment included laxity (KT-1000), the IKDC score and the Lysholm score. The 3D angles of the knees were measured when walking 30 m on flat ground using a system composed of to small inertia units (3D accelerometer and 3D gyroscope) and a portable recorder. Functional settings were optimised and validating to ensure easy precise measurement of the 3D angles. Symmetry of the two knees was quantified using a symmetry index (SI) (difference in amplitude normalised in relation to mean amplitude) and the correlation coefficient CC. Results: Clinical indicators improved during the follow-up (IKDC T1: 3C, 2C; T2: 5B; T3: 2A, 3B; subjective IKD: 53-95; Lysholm 67-96). Mean laxity improved from 8.6m to 2.5 mm. The gait analysis showed increased symmetry in terms of amplitude for flexion-extension (SI: −17% at T1, −1% at T2, 1% at T3), and an increase in symmetry in terms of the rotation signature (CC: 0.16 at T1, 0.99 at T2, 0.99 at T3). There was no trend to varus-valgus. Discussion: This study demonstrates the clinical application of the new ambulatory system for measuring 3D angles of the knee joint. Joint symmetry increased after ACL plasty but still showed some perturbation at 14 months. The results observed here are in agreement with the literature. Other patients and other types of gait are being analysed. Conclusion: This portable system allows gait analysis outside the laboratory, before and after ACL injury. It is very useful for follow-up after surgery.
Resumo:
Introduction: Rotenone is a botanical pesticide derived from extracts of Derris roots, which is traditionally used as piscicide, but also as an industrial insecticide for home gardens. Its mechanism of action is potent inhibition of mitochondrial respiratory chain by uncoupling oxidative phosphorylation by blocking electron transport at complex-I. Despite its classification as mild to moderately toxic to humans (estimated LD50, 300-500 mg/kg), there is a striking variety of acute toxicity of rotenone depending on the formulation (solvents). Human fatalities with rotenone-containing insecticides have been rarely reported, and a rapid deterioration within a few hours of the ingestion has been described previously in one case. Case report: A 49-year-old Tamil man with a history of asthma, ingested 250 mL of an insecticide containing 1.24% of rotenone (3.125 g, 52.1-62.5 mg/kg) in a suicide attempt at home. The product was not labeled as toxic. One hour later, he vomited repeatedly and emergency services were alerted. He was found unconscious with irregular respiration and was intubated. On arrival at the emergency department, he was comatose (GCS 3) with fixed and dilated pupils, and absent corneal reflexes. Physical examination revealed hemodynamic instability with hypotension (55/30 mmHg) and bradycardia (52 bpm). Significant laboratory findings were lactic acidosis (pH 6.97, lactate 17 mmol/L) and hypokalemia (2 mmol/L). Cranial computed tomography (CT) showed early cerebral edema. A single dose of activated charcoal was given. Intravenous hydration, ephedrine, repeated boli of dobutamine, and a perfusor with 90 micrograms/h norepinephine stabilized blood pressure temporarily. Atropine had a minimal effect on heart rate (58 bpm). Intravenous lipid emulsion was considered (log Pow 4.1), but there was a rapid deterioration with refractory hypotension and acute circulatory failure. The patient died 5h after ingestion of the insecticide. No autopsy was performed. Quantitative analysis of serum performed by high-resolution/accurate mass-mass spectrometry and liquid chromatography (LC-HR/AM-MS): 560 ng/mL rotenone. Other substances were excluded by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS/MS). Conclusion: The clinical course was characterized by early severe symptoms and a rapidly fatal evolution, compatible with inhibition of mitochondrial energy supply. Although rotenone is classified as mild to moderately toxic, physicians must be aware that suicidal ingestion of emulsified concentrates may be rapidly fatal. (n=3): stridor, cyanosis, cough (one each). Local swelling after chewing or swallowing soap developed at the earliest after 20 minutes and persisted beyond 24 hours in some cases. Treatment with antihistamines and/or steroids relieved the symptoms in 9 cases. Conclusion: Bar soap ingestion by seniors carries a risk of severe local reactions. Half the patients developed symptoms, predominantly swellings of tongue and/or lips (38%). Cognitive impairment, particularly in the cases of dementia (37%), may increase the risk of unintentional ingestion. Chewing and intraoral retention of soap leads to prolonged contact with the mucosal membranes. Age-associated physiological changes of oral mucosa probably promote the irritant effects of the surfactants. Medical treatment with antihistamines and corticosteroids usually leads to rapid decline of symptoms. Without treatment, there may be a risk of airway obstruction.