90 resultados para Flat panel displays
em Université de Lausanne, Switzerland
Resumo:
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.
Resumo:
The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).
Resumo:
Purpose: To set local dose reference levels (DRL) that allow radiologists to control stochastic and deterministic effects. Methods and materials: Dose indicators for cerebral angiographies and hepatic embolizations were collected during 4 months and analyzed in our hospital. The data were compared when an image amplifier was used instead of a flat panel detector. The Mann and Whitney test was used. Results: For the 40 cerebral angiographies performed the DRL for DAP, fluoroscopy time and number of images were respectively: 166 Gy.cm2, 19 min, 600. The maximum DAP was 490 Gy.cm2 (fluoroscopy time: 84 min). No significant difference for fluoroscopy time and DAP for image amplifier and flat panel detector (p = 0.88) was observed. The number of images was larger for flat panel detector (p = 0.004). The values obtained were slightly over the present proposed DRL: 150 Gy.cm2, 15 min, 400. Concerning the 13 hepatic embolizations the DRL for DAP fluoroscopy time and number of images were: 315 Gy.cm2, 25 min, 370. The maximum DAP delivered was 845 Gy.cm2 (fluoroscopy time of 48 min). No significant difference between image amplifier and flat panel detector was observed (p = 0.005). The values obtained were also slightly over the present proposed DRL: 300 Gy.cm2, 20 min, 200. Conclusion: These results show that the introduction of flat panel detector did not lead to an increase in patient dose. A DRL concerning the cumulative dose (that allow to control the deterministic effect) should be introduced to allow radiologists to have full control on the risks associated with ionizing radiations. Results of this on going study will be presented.
Resumo:
BACKGROUND: Multimodality treatment suites for patients with cerebral arteriovenous malformations (AVM) have recently become available. This study was designed to evaluate feasibility, safety and impact on treatment of a new intraoperative flat-panel (FP) based integrated surgical and imaging suite for combined endovascular and surgical treatment of cerebral AVM. METHODS: Twenty-five patients with AVMs to treat with combined endovascular and surgical interventions were prospectively enrolled in this consecutive case series. The hybrid suite allows combined endovascular and surgical approaches with intraoperative scanner-like imaging (XperCT®) and intraoperative 3D rotational angiography (3D-RA). The impact of intraoperative multimodal imaging on feasibility, workflow of combined interventions, surgery, and unexpected imaging findings were analyzed. RESULTS: Twenty-five patients (mean age 38 ± 18.6 year) with a median Spetzler-Martin grade 2 AVM (range 1-4) underwent combined endovascular and surgical procedures. Sixteen patients presented with a ruptured AVM and nine with an unruptured AVM. In 16 % (n = 4) of cases, intraoperative imaging visualized AVM remnants ≤3 mm and allowed for completion of the resections in the same sessions. Complete resection was confirmed in all n = 16 patients who had follow-up angiography one year after surgery so far. All diagnostic and therapeutical steps, including angiographic control, were performed without having to move the patients CONCLUSION: The hybrid neurointerventional suite was shown to be a safe and useful setup which allowed for unconstrained combined microsurgical and neuroradiological workflow. It reduces the need for extraoperative angiographic controls and subsequent potential surgical revisions a second time, as small AVM remnants can be detected with high security.
Resumo:
The number of fluoroscopy-guided procedures in cardiology is increasing over time and it is appropriate to wonder whether technological progress or change of techniques is influencing patient exposure. The aim of this study is to examine whether patient dose has been decreasing over the years. Patient dose data of more than 7700 procedures were collected from two cardiology centres. A steady increase in the patient dose over the years was observed in both the centres for the two cardiological procedures included in this study. Significant increase in dose was also observed after the installation of a flat-panel detector. The increasing use of radial access may lead to an increase in the patient exposure. The monitoring of dose data over time showed a considerable increase in the patient exposure over time. Actions have to be taken towards dose reduction in both the centres.
Resumo:
NlmCategory="UNASSIGNED">A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.
Resumo:
PURPOSE: The Cancer Vaccine Consortium of the Cancer Research Institute (CVC-CRI) conducted a multicenter HLA-peptide multimer proficiency panel (MPP) with a group of 27 laboratories to assess the performance of the assay. EXPERIMENTAL DESIGN: Participants used commercially available HLA-peptide multimers and a well characterized common source of peripheral blood mononuclear cells (PBMC). The frequency of CD8+ T cells specific for two HLA-A2-restricted model antigens was measured by flow cytometry. The panel design allowed for participants to use their preferred staining reagents and locally established protocols for both cell labeling, data acquisition and analysis. RESULTS: We observed significant differences in both the performance characteristics of the assay and the reported frequencies of specific T cells across laboratories. These results emphasize the need to identify the critical variables important for the observed variability to allow for harmonization of the technique across institutions. CONCLUSIONS: Three key recommendations emerged that would likely reduce assay variability and thus move toward harmonizing of this assay. (1) Use of more than two colors for the staining (2) collect at least 100,000 CD8 T cells, and (3) use of a background control sample to appropriately set the analytical gates. We also provide more insight into the limitations of the assay and identified additional protocol steps that potentially impact the quality of data generated and therefore should serve as primary targets for systematic analysis in future panels. Finally, we propose initial guidelines for harmonizing assay performance which include the introduction of standard operating protocols to allow for adequate training of technical staff and auditing of test analysis procedures.
Resumo:
One of the key problems in conducting surveys is convincing people to participate.¦However, it is often difficult or impossible to determine why people refuse. Panel surveys¦provide information from previous waves that can offer valuable clues as to why people¦refuse to participate. If we are able to anticipate the reasons for refusal, then we¦may be able to take appropriate measures to encourage potential respondents to participate¦in the survey. For example, special training could be provided for interviewers¦on how to convince potential participants to participate.¦This study examines different influences, as determined from the previous wave,¦on refusal reasons that were given by the respondents in the subsequent wave of the¦telephone Swiss Household Panel. These influences include socio-demography, social¦inclusion, answer quality, and interviewer assessment of question understanding and¦of future participation. Generally, coefficients are similar across reasons, and¦between-respondents effects rather than within-respondents effects are significant.¦While 'No interest' reasons are easier to predict, the other reasons are more situational. Survey-specific issues are able to distinguish¦different reasons to some extent.
Resumo:
This paper describes the construction of monthly income from employment and self employment in the Swiss Household Panel (SHP). It documents the assumptions that have to be taken and addresses possibilities and difficulties when relating monthly income variables with the number of working hours. Finally, some descriptive statistics of the monthly wages are provided from 1999 to 2008. These show a high correlation of wages across the years, which is higher than correlation from yearly wages. This underlies the suitability of these variables on monthly wages for labour market research with the SHP. Median and average hourly wages have increased slightly from 2002 to 2008. The inequality of wages has remained stable for the total population.
Resumo:
Little is known about sample behavior and fieldwork effects of different incentives introduced in a household panel survey. This is especially true for telephone surveys. In a randomized experiment, the Swiss Household Panel implemented one prepaid and two promised nonmonetary incentives in the range of 10 to 15 Swiss Francs (7-10 e), plus a no incentive control group. The aim of the paper is to compare effects of these incentives especially on cooperation, but also on sample selection and fieldwork effort, separated by the household and the subsequent individual level. We find small positive cooperation effects of the prepaid incentive on both the household and the individual level especially in larger households. Sample composition is affected to a very minor extent. Finally, incentives tend to save fieldwork time and partially the number of contacts needed on the individual level.
Resumo:
INTRODUCTION: Trialing for intrathecal pump placement is an essential part of the decision-making process in placing a permanent device. In both the United States and the international community, the proper method for trialing is ill defined. METHODS: The Polyanalgesic Consensus Conference (PACC) is a group of well-published experienced practitioners who meet to update the state of care for intrathecal therapies on the basis of current knowledge in the literature and clinical experience. Anexhaustive search is performed to create a base of information that the panel considers when making recommendations for best clinical practices. This literature, coupled with clinical experience, is the basis for recommendations and for identification of gaps in the base of knowledge regarding trialing for intrathecal pump placement. RESULTS: The panel has made recommendations for the proper methods of trialing for long-term intrathecal drug delivery. CONCLUSION: The use of intrathecal drug delivery is an important part of the treatment algorithm for moderate to severe chronic pain. It has become common practice to perform a temporary neuroaxial infusion before permanent device implantation. On the basis of current knowledge, the PACC has developed recommendations to improve care. The need to update these recommendations will be very important as new literature is published.
Resumo:
Attrition is mostly caused by not contacted or refusing sample members. On one hand it is well-known that reasons to attrite due to non-contact are different from those that are due to refusal. On the other hand does non-contact most probably affect household attrition, while refusal can be effective on both households and individuals. In this article, attrition on both the household and (conditional on household participation) the individual level is analysed in three panel surveys from the Cross National Equivalent File (CNEF): the German Socio- Economic Panel (GSOEP), the British Household Panel Study (BHPS), and the Swiss Household Panel (SHP). To follow households over time we use a common rule in all three surveys. First, we find different attrition magnitudes and patterns both across the surveys and also on the household and the individual level. Second, there is more evidence for reinforced rather than compensated household level selection effects if the individual level is also taken into account.
Resumo:
BACKGROUND: Increasing the appropriateness of use of upper gastrointestinal (GI) endoscopy is important to improve quality of care while at the same time containing costs. This study explored whether detailed explicit appropriateness criteria significantly improve the diagnostic yield of upper GI endoscopy. METHODS: Consecutive patients referred for upper GI endoscopy at 6 centers (1 university hospital, 2 district hospitals, 3 gastroenterology practices) were prospectively included over a 6-month period. After controlling for disease presentation and patient characteristics, the relationship between the appropriateness of upper GI endoscopy, as assessed by explicit Swiss criteria developed by the RAND/UCLA panel method, and the presence of relevant endoscopic lesions was analyzed. RESULTS: A total of 2088 patients (60% outpatients, 57% men) were included. Analysis was restricted to the 1681 patients referred for diagnostic upper GI endoscopy. Forty-six percent of upper GI endoscopies were judged to be appropriate, 15% uncertain, and 39% inappropriate by the explicit criteria. No cancer was found in upper GI endoscopies judged to be inappropriate. Upper GI endoscopies judged appropriate or uncertain yielded significantly more relevant lesions (60%) than did those judged to be inappropriate (37%; odds ratio 2.6: 95% CI [2.2, 3.2]). In multivariate analyses, the diagnostic yield of upper GI endoscopy was significantly influenced by appropriateness, patient gender and age, treatment setting, and symptoms. CONCLUSIONS: Upper GI endoscopies performed for appropriate indications resulted in detecting significantly more clinically relevant lesions than did those performed for inappropriate indications. In addition, no upper GI endoscopy that resulted in a diagnosis of cancer was judged to be inappropriate. The use of such criteria improves patient selection for upper GI endoscopy and can thus contribute to efforts aimed at enhancing the quality and efficiency of care. (Gastrointest Endosc 2000;52:333-41).
Resumo:
CONTEXT: New trial data and drug regimens that have become available in the last 2 years warrant an update to guidelines for antiretroviral therapy (ART) in human immunodeficiency virus (HIV)-infected adults in resource-rich settings. OBJECTIVE: To provide current recommendations for the treatment of adult HIV infection with ART and use of laboratory-monitoring tools. Guidelines include when to start therapy and with what drugs, monitoring for response and toxic effects, special considerations in therapy, and managing antiretroviral failure. DATA SOURCES, STUDY SELECTION, AND DATA EXTRACTION: Data that had been published or presented in abstract form at scientific conferences in the past 2 years were systematically searched and reviewed by an International Antiviral Society-USA panel. The panel reviewed available evidence and formed recommendations by full panel consensus. DATA SYNTHESIS: Treatment is recommended for all adults with HIV infection; the strength of the recommendation and the quality of the evidence increase with decreasing CD4 cell count and the presence of certain concurrent conditions. Recommended initial regimens include 2 nucleoside reverse transcriptase inhibitors (tenofovir/emtricitabine or abacavir/lamivudine) plus a nonnucleoside reverse transcriptase inhibitor (efavirenz), a ritonavir-boosted protease inhibitor (atazanavir or darunavir), or an integrase strand transfer inhibitor (raltegravir). Alternatives in each class are recommended for patients with or at risk of certain concurrent conditions. CD4 cell count and HIV-1 RNA level should be monitored, as should engagement in care, ART adherence, HIV drug resistance, and quality-of-care indicators. Reasons for regimen switching include virologic, immunologic, or clinical failure and drug toxicity or intolerance. Confirmed treatment failure should be addressed promptly and multiple factors considered. CONCLUSION: New recommendations for HIV patient care include offering ART to all patients regardless of CD4 cell count, changes in therapeutic options, and modifications in the timing and choice of ART in the setting of opportunistic illnesses such as cryptococcal disease and tuberculosis.