14 resultados para Fixed effect
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND: A possible strategy for increasing smoking cessation rates could be to provide smokers who have contact with healthcare systems with feedback on the biomedical or potential future effects of smoking, e.g. measurement of exhaled carbon monoxide (CO), lung function, or genetic susceptibility to lung cancer. OBJECTIVES: To determine the efficacy of biomedical risk assessment provided in addition to various levels of counselling, as a contributing aid to smoking cessation. SEARCH STRATEGY: We systematically searched the Cochrane Collaboration Tobacco Addiction Group Specialized Register, Cochrane Central Register of Controlled Trials 2008 Issue 4, MEDLINE (1966 to January 2009), and EMBASE (1980 to January 2009). We combined methodological terms with terms related to smoking cessation counselling and biomedical measurements. SELECTION CRITERIA: Inclusion criteria were: a randomized controlled trial design; subjects participating in smoking cessation interventions; interventions based on a biomedical test to increase motivation to quit; control groups receiving all other components of intervention; an outcome of smoking cessation rate at least six months after the start of the intervention. DATA COLLECTION AND ANALYSIS: Two assessors independently conducted data extraction on each paper, with disagreements resolved by consensus. Results were expressed as a relative risk (RR) for smoking cessation with 95% confidence intervals (CI). Where appropriate a pooled effect was estimated using a Mantel-Haenszel fixed effect method. MAIN RESULTS: We included eleven trials using a variety of biomedical tests. Two pairs of trials had sufficiently similar recruitment, setting and interventions to calculate a pooled effect; there was no evidence that CO measurement in primary care (RR 1.06, 95% CI 0.85 to 1.32) or spirometry in primary care (RR 1.18, 95% CI 0.77 to 1.81) increased cessation rates. We did not pool the other seven trials. One trial in primary care detected a significant benefit of lung age feedback after spirometry (RR 2.12; 95% CI 1.24 to 3.62). One trial that used ultrasonography of carotid and femoral arteries and photographs of plaques detected a benefit (RR 2.77; 95% CI 1.04 to 7.41) but enrolled a population of light smokers. Five trials failed to detect evidence of a significant effect. One of these tested CO feedback alone and CO + genetic susceptibility as two different intervention; none of the three possible comparisons detected significant effects. Three others used a combination of CO and spirometry feedback in different settings, and one tested for a genetic marker. AUTHORS' CONCLUSIONS: There is little evidence about the effects of most types of biomedical tests for risk assessment. Spirometry combined with an interpretation of the results in terms of 'lung age' had a significant effect in a single good quality trial. Mixed quality evidence does not support the hypothesis that other types of biomedical risk assessment increase smoking cessation in comparison to standard treatment. Only two pairs of studies were similar enough in term of recruitment, setting, and intervention to allow meta-analysis.
Resumo:
BACKGROUND: A possible strategy for increasing smoking cessation rates could be to provide smokers who have contact with healthcare systems with feedback on the biomedical or potential future effects of smoking, e.g. measurement of exhaled carbon monoxide (CO), lung function, or genetic susceptibility to lung cancer. OBJECTIVES: To determine the efficacy of biomedical risk assessment provided in addition to various levels of counselling, as a contributing aid to smoking cessation. SEARCH METHODS: For the most recent update, we searched the Cochrane Collaboration Tobacco Addiction Group Specialized Register in July 2012 for studies added since the last update in 2009. SELECTION CRITERIA: Inclusion criteria were: a randomized controlled trial design; subjects participating in smoking cessation interventions; interventions based on a biomedical test to increase motivation to quit; control groups receiving all other components of intervention; an outcome of smoking cessation rate at least six months after the start of the intervention. DATA COLLECTION AND ANALYSIS: Two assessors independently conducted data extraction on each paper, with disagreements resolved by consensus. Results were expressed as a relative risk (RR) for smoking cessation with 95% confidence intervals (CI). Where appropriate, a pooled effect was estimated using a Mantel-Haenszel fixed-effect method. MAIN RESULTS: We included 15 trials using a variety of biomedical tests. Two pairs of trials had sufficiently similar recruitment, setting and interventions to calculate a pooled effect; there was no evidence that carbon monoxide (CO) measurement in primary care (RR 1.06, 95% CI 0.85 to 1.32) or spirometry in primary care (RR 1.18, 95% CI 0.77 to 1.81) increased cessation rates. We did not pool the other 11 trials due to the presence of substantial clinical heterogeneity. Of the remaining 11 trials, two trials detected statistically significant benefits: one trial in primary care detected a significant benefit of lung age feedback after spirometry (RR 2.12, 95% CI 1.24 to 3.62) and one trial that used ultrasonography of carotid and femoral arteries and photographs of plaques detected a benefit (RR 2.77, 95% CI 1.04 to 7.41) but enrolled a population of light smokers and was judged to be at unclear risk of bias in two domains. Nine further trials did not detect significant effects. One of these tested CO feedback alone and CO combined with genetic susceptibility as two different interventions; none of the three possible comparisons detected significant effects. One trial used CO measurement, one used ultrasonography of carotid arteries and two tested for genetic markers. The four remaining trials used a combination of CO and spirometry feedback in different settings. AUTHORS' CONCLUSIONS: There is little evidence about the effects of most types of biomedical tests for risk assessment on smoking cessation. Of the fifteen included studies, only two detected a significant effect of the intervention. Spirometry combined with an interpretation of the results in terms of 'lung age' had a significant effect in a single good quality trial but the evidence is not optimal. A trial of carotid plaque screening using ultrasound also detected a significant effect, but a second larger study of a similar feedback mechanism did not detect evidence of an effect. Only two pairs of studies were similar enough in terms of recruitment, setting, and intervention to allow meta-analyses; neither of these found evidence of an effect. Mixed quality evidence does not support the hypothesis that other types of biomedical risk assessment increase smoking cessation in comparison to standard treatment. There is insufficient evidence with which to evaluate the hypothesis that multiple types of assessment are more effective than single forms of assessment.
Resumo:
Introduction: Therapeutic drug monitoring (TDM) of imatinib has been increasingly proposed for chronic myeloid leukaemia (CML) patients, as several studies have found a correlation between trough concentrations (Cmin) >=1000ng/ml and improved response. The pharmacological monitoring project of EUTOS (European Treatment and Outcome Study) was launched to increase the availability of imatinib TDM, standardize labs, and validate proposed Cmin thresholds. Using the collected data, the objective of this analysis was to characterize imatinib Population pharmacokinetics (Pop-PK) in a large cohort of European patients, to quantify its variability and the influence of demographic factors and comedications, and to derive individual exposure variables suitable for further concentration-effect analyses.¦Methods: 4095 PK samples from 2478 adult patients were analyzed between 2006 and 2010 by LC-MS-MS and considered for Pop-PK analysis by NONMEM®. Model building used data from 973 patients with >=2 samples available (2590 samples). A sensitivity analysis was performed using all data. Available comedications (27%) were classified into inducers or inhibitors of P-glycoprotein, CYP3A4/5 and organic-cation-transporter-1 (hOCT-1).¦Results: A one-compartment model with linear elimination, zero-order absorption fitted the data best. Estimated Pop-PK parameters (interindividual variability, IIV %CV) for a 40-year old male patient were: clearance CL = 17.3 L/h (37.7%), volume V = 429L (51.1%), duration of absorption D1 = 3.2h. Outliers, reflecting potential compliance and time recording errors, were taken into account by estimating an IIV on the residual error (35.4%). Intra-individual residuals were 29.1% (proportional) plus ± 84.6 ng/mL (additive). Female patients had a 15.2% lower CL (14.6 L/h). A piece-wise linear effect of age estimated a CL of 18.7 L/h at 20 years, 17.3 L/h at 40 and 13.8 L/h at 60 years. These covariates explained 2% (CL) and 4.5% (V) of IIV variability. No effect of comedication was found. The sensitivity analysis expectedly estimated increased IIV, but similar fixed effect parameters.¦Conclusion: Imatinib PK was well described in a large cohort of CML patients under field conditions and results were concordant with previous studies. Patient characteristics explain only little IIV, confirming limited utility of prior dosage adjustment. As intra-variability is smaller than inter-patient variability, dose adjustment guided by TDM could however be beneficial in order to bring Cmin into a given therapeutic target.
Resumo:
Introduction: Neuronal oscillations have been the focus of increasing interest in the neuroscientific community, in part because they have been considered as a possible integrating mechanism through which internal states can influence stimulus processing in a top-down way (Engel et al., 2001). Moreover, increasing evidence indicates that oscillations in different frequency bands interact with one other through coupling mechanisms (Jensen and Colgin, 2007). The existence and the importance of these cross-frequency couplings during various tasks have been verified by recent studies (Canolty et al., 2006; Lakatos et al., 2007). In this study, we measure the strength and directionality of two types of couplings - phase-amplitude couplings and phase-phase couplings - between various bands in EEG data recorded during an illusory contour experiment that were identified using a recently-proposed adaptive frequency tracking algorithm (Van Zaen et al., 2010). Methods: The data used in this study have been taken from a previously published study examining the spatiotemporal mechanisms of illusory contour processing (Murray et al., 2002). The EEG in the present study were from a subset of nine subjects. Each stimulus was composed of 'pac-man' inducers presented in two orientations: IC, when an illusory contour was present, and NC, when no contour could be detected. The signals recorded by the electrodes P2, P4, P6, PO4 and PO6 were averaged, and filtered into the following bands: 4-8Hz, 8-12Hz, 15-25Hz, 35-45Hz, 45-55Hz, 55-65Hz and 65-75Hz. An adaptive frequency tracking algorithm (Van Zaen et al., 2010) was then applied in each band in order to extract the main oscillation and estimate its frequency. This additional step ensures that clean phase information is obtained when taking the Hilbert transform. The frequency estimated by the tracker was averaged over sliding windows and then used to compare the two conditions. Two types of cross-frequency couplings were considered: phase-amplitude couplings and phase-phase couplings. Both types were measured with the phase locking value (PLV, Lachaux et al., 1999) over sliding windows. The phase-amplitude couplings were computed with the phase of the low frequency oscillation and the phase of the amplitude of the high frequency one. Different coupling coefficients were used when measuring phase-phase couplings in order to estimate different m:n synchronizations (4:3, 3:2, 2:1, 3:1, 4:1, 5:1, 6:1, 7:1, 8:1 and 9:1) and to take into account the frequency differences across bands. Moreover, the direction of coupling was estimated with a directionality index (Bahraminasab et al., 2008). Finally, the two conditions IC and NC were compared with ANOVAs with 'subject' as a random effect and 'condition' as a fixed effect. Before computing the statistical tests, the PLV values were transformed into approximately normal variables (Penny et al., 2008). Results: When comparing the mean estimated frequency across conditions, a significant difference was found only in the 4-8Hz band, such that the frequency within this band was significantly higher for IC than NC stimuli starting at ~250ms post-stimulus onset (Fig. 1; solid line shows IC and dashed line NC). Significant differences in phase-amplitude couplings were obtained only when the 4-8 Hz band was taken as the low frequency band. Moreover, in all significant situations, the coupling strength is higher for the NC than IC condition. An example of significant difference between conditions is shown in Fig. 2 for the phase-amplitude coupling between the 4-8Hz and 55-65Hz bands (p-value in top panel and mean PLV values in the bottom panel). A decrease in coupling strength was observed shortly after stimulus onset for both conditions and was greater for the condition IC. This phenomenon was observed with all other frequency bands. The results obtained for the phase-phase couplings were more complex. As for the phase-amplitude couplings, all significant differences were obtained when the 4-8Hz band was considered as the low frequency band. The stimulus condition exhibiting the higher coupling strength depended on the ratio of the coupling coefficients. When this ratio was small, the IC condition exhibited the higher phase-phase coupling strength. When this ratio was large, the NC condition exhibited the higher coupling strength. Fig. 3 shows the phase-phase couplings between the 4-8Hz and 35-45Hz bands for the coupling coefficient 6:1, and the coupling strength was significantly higher for the IC than NC condition. By contrast, for the coupling coefficient 9:1 the NC condition gave the higher coupling strength (Fig. 4). Control analyses verified that it is not a consequence of the frequency difference between the two conditions in the 4-8Hz band. The directionality measures indicated a transfer of information from the low frequency components towards the high frequency ones. Conclusions: Adaptive tracking is a feasible method for EEG analyses, revealing information both about stimulus-related differences and coupling patterns across frequencies. Theta oscillations play a central role in illusory shape processing and more generally in visual processing. The presence vs. absence of illusory shapes was paralleled by faster theta oscillations. Phase-amplitude couplings were decreased more for IC than NC and might be due to a resetting mechanism. The complex patterns in phase-phase coupling between theta and beta/gamma suggest that the contribution of these oscillations to visual binding and stimulus processing are not as straightforward as conventionally held. Causality analyses further suggest that theta oscillations drive beta/gamma oscillations (see also Schroeder and Lakatos, 2009). The present findings highlight the need for applying more sophisticated signal analyses in order to establish a fuller understanding of the functional role of neural oscillations.
Resumo:
BACKGROUND: In most of the emergency departments (ED) in developed countries, a subset of patients visits the ED frequently. Despite their small numbers, these patients are the source of a disproportionally high number of all ED visits, and use a significant proportion of healthcare resources. They place a heavy economic burden on hospital and healthcare systems budgets overall. Several interventions have been carried out to improve the management of these ED frequent users. Case management has been shown in some North American studies to reduce ED utilization and costs. In these studies, cost analyses have been carried out from the hospital perspective without examining the costs induced by healthcare consumed in the community. However, case management might reduce ED visits and costs from the hospital's perspective, but induce substitution effects, and increase health service utilization outside the hospital. This study examined if an interdisciplinary case-management intervention-compared to standard ED care -reduced costs generated by frequent ED users not only from the hospital perspective, but also from the healthcare system perspective-that is, from a broader perspective taking into account the costs of healthcare services used outside the hospital. METHODS: In this randomized controlled trial, 250 adult frequent emergency department users (5 or more visits during the previous 12 months) who visited the ED of the University Hospital of Lausanne, Switzerland, between May 2012 and July 2013 were allocated to one of two groups: case management intervention (CM) or standard ED care (SC), and followed up for 12 months. Depending on the perspective of the analysis, costs were evaluated differently. For the analysis from the hospital's perspective, the true value of resources used to provide services was used as a cost estimate. These data were obtained from the hospital's analytical accounting system. For the analysis from the health-care system perspective, all health-care services consumed by users and charged were used as an estimate of costs. These data were obtained from health insurance providers for a subsample of participants. To allow comparisons in a same time period, individual monthly average costs were calculated. Multivariate linear models including a fixed effect "group" were run using socio-demographic characteristics and health-related variables as controlling variables (age, gender, educational level, citizenship, marital status, somatic and mental health problems, and risk behaviors).
Resumo:
Background: In most of the emergency departments (ED) in developed countries, a subset of patients visits the ED frequently. Despite their small numbers, these patients are the source of a disproportionally high number of all ED visits, and use a significant proportion of healthcare resources. They place a heavy economic burden on hospital and healthcare system budgets overall. In order to improve the management of these patients, the University hospital of Lausanne, Switzerland implemented a case management intervention (CM) between May 2012 and July 2013. In this randomized controlled trial, 250 frequent ED users (visits>5 during previous 12 months) were allocated to either the CM group or the standard ED care (SC) group and followed up for 12 months. The first result of the CM was to reduce significantly the ED visits. The present study examined whether the CM intervention also reduced the costs generated by the ED frequent users not only from the hospital perspective, but also from the healthcare system perspective. Methods: Cost data were obtained from the hospital's analytical accounting system and from health insurances. Multivariate linear models including a fixed effect "group" and socio-demographic characteristics and health-related variables were run.
Resumo:
Background: Many studies have found considerable variations in the resource intensity of physical therapy episodes. Although they have identified several patient-and provider-related factors, few studies have examined their relative explanatory power. We sought to quantify the contribution of patients and providers to these differences and examine how effective Swiss regulations are (nine-session ceiling per prescription and bonus for first treatments). Methods: Our sample consisted of 87,866 first physical therapy episodes performed by 3,365 physiotherapists based on referrals by 6,131 physicians. We modeled the number of visits per episode using a multilevel log linear regression with crossed random effects for physiotherapists and physicians and with fixed effects for cantons. The three-level explanatory variables were patient, physiotherapist and physician characteristics. Results: The median number of sessions was nine (interquartile range 6-13). Physical therapy use increased with age, women, higher health care costs, lower deductibles, surgery and specific conditions. Use rose with the share of nine-session episodes among physiotherapists or physicians, but fell with the share of new treatments. Geographical area had no influence. Most of the variance was explained at the patient level, but the available factors explained only 4% thereof. Physiotherapists and physicians explained only 6% and 5% respectively of the variance, although the available factors explained most of this variance. Regulations were the most powerful factors. Conclusion: Against the backdrop of abundant physical therapy supply, Swiss financial regulations did not restrict utilization. Given that patient-related factors explained most of the variance, this group should be subject to closer scrutiny. Moreover, further research is needed on the determinants of patient demand.
Resumo:
Arterial hypertension is a highly heterogeneous condition. It is therefore not surprising that blood pressure lowering agents acting via a given mechanism allow a normalization of blood pressure in a fraction of hypertensive subjects only. The combination of drugs with different mechanisms of action on the cardiovascular system results in a considerably higher antihypertensive efficacy, not only with regard to the absolute blood pressure reduction but also in the number of responders. This effect is not achieved at the expenses of tolerance, because usually lower doses of the combined agents are sufficient to achieve the target blood pressure. The administration of antihypertensive agents in fixed combination has the advantage of its simplicity for both the physician as well as the patient. This aspect also explains the increasing popularity of fixed combinations as a valuable option in the initial treatment of the hypertensive patient.
Resumo:
Background and Aims: To protect the population from environmental tobacco smoke (ETS) Switzerland introduced a nationwide rather heterogeneous smoking ban in May 2010. The exposure situation of non-smoking hospitality workers before and after implementation of the new law is being assessed in a prospective cohort study. Methods: Exposure to ETS was measured using a novel method developed by the Institute for Work and Health in Lausanne. It is a passive sampler called MoNIC (Monitor of NICotine). The nicotine of the ETS is fixed onto a filter and transformed into salt of not volatile nicotine. Subsequently the number of passively smoked cigarettes is calculated. Badges were placed at the workplace as well as distributed to the participants for personal measuring. Additionally a salivary sample was taken to determine nicotine concentration. Results: At baseline Spearman's correlation between workplace and personal badge was 0.47. The average cigarette equivalents per day at the workplace obtained by badge significantly dropped from 5.1 (95%- CI: 2.4 to 7.9) at baseline to 0.3 (0.2 to 0.4) at first follow-up (n=29) three months later (p<0.001). For personal badges the number of passively smoked cigarettes declined from 1.5 (2.7 to 0.4) per day to 0.5 (0.3 to 0.8) (n=16).Salivary nicotine concentration in a subset of 13 participants who had worked on the day prior to the examination was 2.63 ng/ml before and 1.53 ng/ml after the ban (p=0.04). Spearman's correlation of salivary nicotine was 0.56 with workplace badge and 0.79 with personal badge concentrations. Conclusions: Workplace measurements clearly reflect the smoking regulation in a venue. The MoNIC badge proves to be a sensitive measuring device to determine personal ETS exposure and it is a demonstrative measure for communication with lay audiences and study participants as the number of passively smoked cigarettes is an easily conceivable result.
Resumo:
Background: Prognostic and predictive markers are of great importance for future study designs and essential for the interpretation of clinical trials incorporating an EGFR-inhibitor. The current study prospectively assessed and validated KRAS, BRAF and PIK3CA mutations in rectal cancer patients screened for the trial SAKK41/07 of concomitant preoperative radio-chemotherapy with or without panitumumab.Methods: Macrodissection was performed on pretreatment formalin fixed paraffin embedded biopsy tissue sections to arrive at a minimum of 50% of tumor cells. DNA was extracted with the Maxwell 16 FFPE Tissue LEV DNA purification kit. After PCR amplification, mutations were identified by pyrosequencing. We prospectively analysed pretreatment biopsy material from 149 rectal cancer pts biopsies for KRAS (exon 2 codon 12 [2-12] and 13 [2-13], exon 3 codon 59 [3-59]) and 61 [3-61], exon 4 codon 117 [4-117] and 146 [4-146]). Sixty-eight pts (KRASwt exon 2, 3 only) were further analysed for BRAF (exon 15 codon 600) and PIK3CA (exon 9 codon 542, 545 and 546, exon 20 codon 1043 [20-1043] and 1047 [20-1047]) mutations, and EGFR copy number by qPCR. For the calculation of the EGFR copy number, we used KRAS copy number as internal reference standard. The calculation was done on the basis of the two standard curves relative quantification method.Results: In 149 screened pts with rectal cancer, the prevalence of KRAS mutations was 36%. Among the 68 pts enrolled in SAKK 41/07 based on initially presumed KRASwt status (exon 2/codons 12+13), 18 pts (26%) had a total of 23 mutations in the RAS/PIK3CA-pathways upon validation analysis. Twelve pts had a KRAS mutation, 7 pts had a PIK3CA mutation, 3 pts had a NRAS mutation, 1 patient a BRAF mutation. Surprisingly, five of these pts had double- mutations, including 4 pts with KRAS plus PIK3CA mutations, and 1 pt with NRAS plus PIK3CA mutations. The median normalized EGFR copy number was 1. Neither mutations of KRAS, BRAF, and PIK3CA, nor EGFR copy number were statistically associated with the primary study endpoint pCR (pathological complete regression).Conclusions: The prevalence of KRAS mutations in rectal and in colon cancer appears to be similar. BRAF mutations are rare; PIK3CA mutations are more common (10%). EGFR copy number is not increased in rectal cancer. A considerable number or KRAS exon 2 wt tumors harbored KRAS exon 3+4 mutations. Further study is needed to determine if KRAS testing should include exons 2-4.
Resumo:
Effet d'un bolus intraveineux de phénylephrine ou d'éphedríne sur le flux sanguin cutané lors d'une anesthésie rachidienne Introduction : La phénylephrine et l'éphedrine sont des substances vaso-actives utilisées de routine pour corriger des épisodes d'hypotension artérielle induits par l'anesthésie intrarachidienne. L'influence de ces deux vasopresseurs sur le flux sanguin cutané (FSC) dans ce contexte n'a jusqu'à maintenant pas été décrite. Cette étude évalue l'effet d'une injection intraveineuse de 75 µg de phénylephrine ou de 7.5 mg d'éphedrine sur le FSC mesuré par Laser Doppler, dans les zones concernées parle bloc sympathiqué induit par l'anesthésie intrarachidienne (membres inférieurs) et dans les zones non concernées (membres supérieurs). Méthode :Après acceptation par le Comité d'Éthique, et obtention de leur accord écrit, 20 patients devant subir une intervention chirurgicale élective en décubitus dorsal sous anesthésie. intrarachidienne ont été inclus dans cette étude randomisée en double insu. Le FSC a été mesuré en continu par deux sondes fixées l'une à la cuisse (zone avec bloc sympathique) et l'autre sur l'avantbras (zone sans bloc sympathique). Les valeurs de FSC ont été enregistrées après l'anesthésie rachidienne (valeur contrôle), puis après l'injection i.v. dè phénylephrine (10 patients) ou d'éphedrine (10 patients) pour corriger une hypotension définie comme une chute de 20 mmHg de la pression artérielle systolique. Les variations de FSC exprimées en pourcentage de la valeur contrôle moyenne (+/- écart type) ont été analysées par le test t de Student. Résultats :Les données démographiques des patients et le niveau sensitif induit par l'anesthésie rachidienne sont similaires dans les deux groupes. Aux doses utilisées, seule l'éphedrine restaure la pression artérielle aux valeurs précédant l'anesthésie rachidienne. La phénylephrine augmente le FSC de l'avant-bras de 44% (+/- 79%) et de la cuisse de 34% (+/-24%), alors que l'éphedrine diminue le débit sanguin cutané de l'avant-bras de 16% (+/- 15%) et de la cuisse de 22% (+/-11%). Conclusion : L'injection intraveineuse de phénylephrine et d'éphedrine ont des effets opposés sur le flux sanguin cutané, et cette réponse n'est pas modifiée par le bloc sympathique.. Cette différence peut s'expliquer par la distribution des sous-types de récepteurs adrénergiques alpha et leur prédominance relative dans les veines et les artères de différents diamètres perfusant le tissu sous-cutané et la peau. L'éphedrine, èn raison de sa meilleure efficacité pour traiter les épisodes d'hypotension artérielle après anesthésie intrarachidienne devrait être préféré à la phénylephrine, leurs effets opposés sur le flux sanguin cutané n'étant pas pertinents en pratique clinique. SUMMARY Background: Phenylephrine or ephedrine is routinely used to correct hypotensive episodes fallowing spinal anaesthesia (SA). The influence of these two vasopressors on skin blood flow (SBF) has not yet been described. We have therefore evaluated the effects of an i.v. bolus of 75 µg phenylephrine or 7.5 mg of ephedrine on SBF measured by laser Doppler flowmetry during sympathetic blockade induced by SA. Methods: With Ethical Committee approval and written consent, 20 patients scheduled for elective procedures in supine position under SA were enrolled in this double-blind randomized study. SBF was measured continuously by two probes fixed at the thigh (area with sympathic blockade) and forearm level (area without sympathic blockade) respectively. SBF values were recorded after SA (control values) and then after a bolus administration of phenylephriné (n=10) or ephedrine (n=10) when systolic blood pressure decreased by 20 mmHg. Changes were expressed as percentage of control SBF values and analysed by Student's paired t-test. Results: Patient characteristics and dermatomal sensory levels were similar in both groups. Phenylephrine increases mean SBF at the forearm level by 44% (79%) [mean (SD)j and at the thigh by 34% (24%). Ephedrine decreases SBF at the forearm level by 16% (15%) and at the thigh by 22% (il%). Ephedrine bolus restores arterial blood pressure to pre-anaesthesia values, whereas phenylephrine does not. Conclusion: Administratión of phenylephrine and ephedrine has opposite effects on skin blood flow and sympathetic blockade does not modify this response. These findings could be explained by the distribution of the alpha-adrenoréceptor subtypes and their relative predominance among veins and arteries of different size perfusing the subcutaneous tissue and the skin. Ephedrine, due to its better efficacy to correct hypotensive episodes following SA, should be preferred, to phenylephrine, their opposite effects on SBF being not relevant for clinical practice.
Resumo:
BACKGROUND: Non-steroidal anti-inflammatory drugs are known to promote sodium retention and to blunt the blood pressure lowering effects of several classes of antihypertensive agents including beta-blockers, diuretics and angiotensin converting enzyme (ACE) inhibitors. The purpose of the present study was to investigate the acute and sustained effects of indomethacin on the renal response to the angiotensin II receptor antagonist valsartan and to the ACE inhibitor enalapril. METHODS: Twenty normotensive subjects maintained on fixed sodium intake (100 mmol sodium/day) were randomized to receive for one week: valsartan 80 mg o.d., enalapril 20 mg o.d., valsartan 80 mg o.d. + indomethacin 50 mg bid and enalapril 20 mg o.d. + indomethacin 50 mg bid. This single-blind study was designed as a parallel (valsartan vs. enalapril) and cross-over trial (valsartan or enalapril vs. valsartan + indomethacin or enalapril + indomethacin). Renal hemodynamics and urinary electrolyte excretion were measured for six hours after the first and seventh administration of each treatment regimen. RESULTS: The results show that valsartan and enalapril have comparable renal effects characterized by no change in glomerular filtration rate and significant increases in renal plasma flow and sodium excretion. The valsartan- and enalapril-induced renal vasodilation is not significantly blunted by indomethacin. However, indomethacin similarly abolishes the natriuresis induced by the angiotensin II antagonist and the ACE inhibitor. CONCLUSIONS: This observation suggests that although angiotensin receptor antagonists do not affect prostaglandin metabolism, the administration of a non-steroidal anti-inflammatory drug blunts the natriuretic response to angiotensin receptor blockade.
Resumo:
BACKGROUND: Normal weight obesity (NWO) is defined as an excessive body fat associated with a normal body mass index (BMI < 25 kg/m(2)), but its prevalence in the general population is unknown. AIM OF THE STUDY: To assess the prevalence of NWO in Switzerland according to different cut points used to define excess body fat. METHODS: Cross-sectional study including 3,213 women and 2,912 men aged 35-75 years. Body fat was assessed by bioelectrical impedance analysis and prevalence of NWO was assessed using four previously published definitions for excess body fat. RESULTS: Percent body fat increased with age: in men, the values (mean +/- SD) were 20.2 +/- 5.4, 23.0 +/- 5.4, 26.3 +/- 5.2 and 28.2 +/- 4.6 for age groups 35-44, 45-54, 55-64 and 65-75 years, respectively; the corresponding values for women were 29.9 +/- 7.8, 33.1 +/- 7.4, 36.7 +/- 7.5 and 39.6 +/- 6.9. In men, prevalence of NWO was <1% irrespective of the definition used. Conversely, in women, a 1- to 20-fold difference (from 1.4 to 27.8%) in NWO prevalence was found. The prevalence of NWO increased with age when age-independent cut points were used in women, but not in men. CONCLUSIONS: Prevalence of NWO is low in the general population and higher in women than in men. The prevalence is highly dependent on the criteria used to define excess body fat, namely in women. The use of gender- and age-specific cut points to define excess body fat is better than fixed or gender-specific only cut points.
Resumo:
Purpose: The aim of this review was to systematically evaluate and compare the frequency of veneer chipping and core fracture of zirconia fixed dental prostheses (FOPS) and porcelain-fused-to-metal (PFM) FDPs and determine possible influencing factors. Materials and Methods: The SCOPUS database and International Association of Dental Research abstracts were searched for clinical studies involving zirconia and PFM FDPs. Furthermore, studies that were integrated into systematic reviews on PFM FDPs were also evaluated. The principle investigators of any clinical studies on zirconia FDPs were contacted to provide additional information. Based on the available information for each FOP, a data file was constructed. Veneer chipping was divided into three grades (grade 1 = polishing, grade 2 = repair, grade 3 = replacement). To assess the frequency of veneer chipping and possible influencing factors, a piecewise exponential model was used to adjust for a study effect. Results: None of the studies on PFM FDPs (reviews and additional searching) sufficiently satisfied the criteria of this review to be included. Thirteen clinical studies on zirconia FDPs and two studies that investigated both zirconia and PFM FDPs were identified. These studies involved 664 zirconia and 134 PFM FDPs at baseline. Follow-up data were available for 595 zirconia and 127 PFM FDPs. The mean observation period was approximately 3 years for both groups. The frequency of core fracture was less than 1% in the zirconia group and 0% in the PFM group. When all studies were included, 142 veneer chippings were recorded for zirconia FDPs (24%) and 43 for PFM FDPs (34%). However, the studies differed extensively with regard to veneer chipping of zirconia: 85% of all chippings occurred in 4 studies, and 43% of all chippings included zirconia FDPs. If only studies that evaluated both types of core materials were included, the frequency of chipping was 54% for the zirconia-supported FDPs and 34% for PFM FDPs. When adjusting the survival rate for the study effect, the difference between zirconia and PFM FDPs was statistically significant for all grades of chippings (P = .001), as well as for chipping grade 3 (P = .02). If all grades of veneer chippings were taken into account, the survival of PFM FDPs was 97%, while the survival rate of the zirconia FDPs was 90% after 3 years for a typical study. For both PFM and zirconia FDPs, the frequency of grades 1 and 2 veneer chippings was considerably higher than grade 3. Veneer chipping was significantly less frequent in pressed materials than in hand-layered materials, both for zirconia and PFM FDPs (P = .04). Conclusions: Since the frequency of veneer chipping was significantly higher in the zirconia FDPs than PFM FDPs, and as refined processing procedures have started to yield better results in the laboratory, new clinical studies with these new procedures must confirm whether the frequency of veneer chipping can be reduced to the level of PFM. Int J Prosthodont 2010;23:493-502