58 resultados para Extraction yield
em Université de Lausanne, Switzerland
Resumo:
Among the various determinants of treatment response, the achievement of sufficient blood levels is essential for curing malaria. For helping us at improving our current understanding of antimalarial drugs pharmacokinetics, efficacy and toxicity, we have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 200mul of plasma for the simultaneous determination of 14 antimalarial drugs and their metabolites which are the components of the current first-line combination treatments for malaria (artemether, artesunate, dihydroartemisinin, amodiaquine, N-desethyl-amodiaquine, lumefantrine, desbutyl-lumefantrine, piperaquine, pyronaridine, mefloquine, chloroquine, quinine, pyrimethamine and sulfadoxine). Plasma is purified by a combination of protein precipitation, evaporation and reconstitution in methanol/ammonium formate 20mM (pH 4.0) 1:1. Reverse-phase chromatographic separation of antimalarial drugs is obtained using a gradient elution of 20mM ammonium formate and acetonitrile both containing 0.5% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 21min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effect variability, overall process efficiency, standard addition experiments as well as antimalarials short- and long-term stability in plasma. The reactivity of endoperoxide-containing antimalarials in the presence of hemolysis was tested both in vitro and on malaria patients samples. With this method, signal intensity of artemisinin decreased by about 20% in the presence of 0.2% hemolysed red-blood cells in plasma, whereas its derivatives were essentially not affected. The method is precise (inter-day CV%: 3.1-12.6%) and sensitive (lower limits of quantification 0.15-3.0 and 0.75-5ng/ml for basic/neutral antimalarials and artemisinin derivatives, respectively). This is the first broad-range LC-MS/MS assay covering the currently in-use antimalarials. It is an improvement over previous methods in terms of convenience (a single extraction procedure for 14 major antimalarials and metabolites reducing significantly the analytical time), sensitivity, selectivity and throughput. While its main limitation is investment costs for the equipment, plasma samples can be collected in the field and kept at 4 degrees C for up to 48h before storage at -80 degrees C. It is suited to detecting the presence of drug in subjects for screening purposes and quantifying drug exposure after treatment. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of antimalarials and better define the therapeutic dose ranges in different patient populations.
Resumo:
The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.
Resumo:
Because of the large variability in the pharmacokinetics of anti-HIV drugs, therapeutic drug monitoring in patients may contribute to optimize the overall efficacy and safety of antiretroviral therapy. An LC-MS/MS method for the simultaneous assay in plasma of the novel antiretroviral agents rilpivirine (RPV) and elvitegravir (EVG) has been developed to that endeavor. Plasma samples (100 μL) extraction is performed by protein precipitation with acetonitrile, and the supernatant is subsequently diluted 1:1 with 20-mM ammonium acetate/MeOH 50:50. After reverse-phase chromatography, quantification of RPV and EVG, using matrix-matched calibration samples, is performed by electrospray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The stable isotopic-labeled compounds RPV-(13) C6 and EVG-D6 were used as internal standards. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<6.4%), as well as EVG and RPV short and long-term stability in plasma. Calibration curves were validated over the clinically relevant concentrations ranging from 5 to 2500 ng/ml for RPV and from 50 to 5000 ng/ml for EVG. The method is precise (inter-day CV%: 3-6.3%) and accurate (3.8-7.2%). Plasma samples were found to be stable (<15%) in all considered conditions (RT/48 h, +4°C/48 h, -20°C/3 months and 60°C/1 h). Selected metabolite profiles analysis in patients' samples revealed the presence of EVG glucuronide, that was well separated from parent EVG, allowing to exclude potential interferences through the in-source dissociation of glucuronide to parent drug. This new, rapid and robust LCMS/MS assay for the simultaneous quantification of plasma concentrations of these two major new anti-HIV drugs EVG and RPV offers an efficient analytical tool for clinical pharmacokinetics studies and routine therapeutic drug monitoring service. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
The aim of this study was to evaluate the forensic protocol recently developed by Qiagen for the QIAsymphony automated DNA extraction platform. Samples containing low amounts of DNA were specifically considered, since they represent the majority of samples processed in our laboratory. The analysis of simulated blood and saliva traces showed that the highest DNA yields were obtained with the maximal elution volume available for the forensic protocol, that is 200 ml. Resulting DNA extracts were too diluted for successful DNA profiling and required a concentration. This additional step is time consuming and potentially increases inversion and contamination risks. The 200 ml DNA extracts were concentrated to 25 ml, and the DNA recovery estimated with real-time PCR as well as with the percentage of SGM Plus alleles detected. Results using our manual protocol, based on the QIAamp DNA mini kit, and the automated protocol were comparable. Further tests will be conducted to determine more precisely DNA recovery, contamination risk and PCR inhibitors removal, once a definitive procedure, allowing the concentration of DNA extracts from low yield samples, will be available for the QIAsymphony.
Resumo:
The goal of this study was to compare the quantity and purity of DNA extracted from biological tracesusing the QIAsymphony robot with that of the manual QIAamp DNA mini kit currently in use in ourlaboratory. We found that the DNA yield of robot was 1.6-3.5 times lower than that of the manualprotocol. This resulted in a loss of 8% and 29% of the alleles correctly scored when analyzing 1/400 and 1/800 diluted saliva samples, respectively. Specific tests showed that the QIAsymphony was at least 2-16times more efficient at removing PCR inhibitors. The higher purity of the DNA may therefore partlycompensate for the lower DNA yield obtained. No case of cross-contamination was observed amongsamples. After purification with the robot, DNA extracts can be automatically transferred in 96-wellsplates, which is an ideal format for subsequent RT-qPCR quantification and DNA amplification. Lesshands-on time and reduced risk of operational errors represent additional advantages of the robotic platform.
Resumo:
The aim of this study was to evaluate the combination of abdominoplasty with liposuction of both flanks with regards to length of scar, complications, and patient's satisfaction. A retrospective analysis of 35 patients who underwent esthetic abdominoplasty at our institution between 2002 and 2004 was performed. Thirteen patients underwent abdominoplasty with liposuction of both flanks, 22 patients underwent conventional abdominoplasty. Liposuction of the flanks did not increase the rate of complications of the abdominoplasty procedures. We found a tendency toward shorter scars in patients who underwent abdominoplasty combined with liposuction of the flanks. Implementation of 3-dimensional laser surface scanning to objectify the postoperative outcomes, documented a comparable degree of flatness of the achieved body contouring in both procedures. 3-dimensional laser surface scanning can be a valuable tool to objectify assessment of postoperative results.
Resumo:
We present a new method for lysis of single cells in continuous flow, where cells are sequentially trapped, lysed and released in an automatic process. Using optimized frequencies, dielectrophoretic trapping allows exposing cells in a reproducible way to high electrical fields for long durations, thereby giving good control on the lysis parameters. In situ evaluation of cytosol extraction on single cells has been studied for Chinese hamster ovary (CHO) cells through out-diffusion of fluorescent molecules for different voltage amplitudes. A diffusion model is proposed to correlate this out-diffusion to the total area of the created pores, which is dependent on the potential drop across the cell membrane and enables evaluation of the total pore area in the membrane. The dielectrophoretic trapping is no longer effective after lysis because of the reduced conductivity inside the cells, leading to cell release. The trapping time is linked to the time required for cytosol extraction and can thus provide additional validation of the effective cytosol extraction for non-fluorescent cells. Furthermore, the application of one single voltage for both trapping and lysis provides a fully automatic process including cell trapping, lysis, and release, allowing operating the device in continuous flow without human intervention.
Resumo:
INTRODUCTION: Although long-term video-EEG monitoring (LVEM) is routinely used to investigate paroxysmal events, short-term video-EEG monitoring (SVEM) lasting <24 h is increasingly recognized as a cost-effective tool. Since, however, relatively few studies addressed the yield of SVEM among different diagnostic groups, we undertook the present study to investigate this aspect. METHODS: We retrospectively analyzed 226 consecutive SVEM recordings over 6 years. All patients were referred because routine EEGs were inconclusive. Patients were classified into 3 suspected diagnostic groups: (1) group with epileptic seizures, (2) group with psychogenic nonepileptic seizures (PNESs), and (3) group with other or undetermined diagnoses. We assessed recording lengths, interictal epileptiform discharges, epileptic seizures, PNESs, and the definitive diagnoses obtained after SVEM. RESULTS: The mean age was 34 (±18.7) years, and the median recording length was 18.6 h. Among the 226 patients, 127 referred for suspected epilepsy - 73 had a diagnosis of epilepsy, none had a diagnosis of PNESs, and 54 had other or undetermined diagnoses post-SVEM. Of the 24 patients with pre-SVEM suspected PNESs, 1 had epilepsy, 12 had PNESs, and 11 had other or undetermined diagnoses. Of the 75 patients with other diagnoses pre-SVEM, 17 had epilepsy, 11 had PNESs, and 47 had other or undetermined diagnoses. After SVEM, 15 patients had definite diagnoses other than epilepsy or PNESs, while in 96 patients, diagnosis remained unclear. Overall, a definitive diagnosis could be reached in 129/226 (57%) patients. CONCLUSIONS: This study demonstrates that in nearly 3/5 patients without a definitive diagnosis after routine EEG, SVEM allowed us to reach a diagnosis. This procedure should be encouraged in this setting, given its time-effectiveness compared with LVEM.
Resumo:
BACKGROUND: Increasing the appropriateness of use of upper gastrointestinal (GI) endoscopy is important to improve quality of care while at the same time containing costs. This study explored whether detailed explicit appropriateness criteria significantly improve the diagnostic yield of upper GI endoscopy. METHODS: Consecutive patients referred for upper GI endoscopy at 6 centers (1 university hospital, 2 district hospitals, 3 gastroenterology practices) were prospectively included over a 6-month period. After controlling for disease presentation and patient characteristics, the relationship between the appropriateness of upper GI endoscopy, as assessed by explicit Swiss criteria developed by the RAND/UCLA panel method, and the presence of relevant endoscopic lesions was analyzed. RESULTS: A total of 2088 patients (60% outpatients, 57% men) were included. Analysis was restricted to the 1681 patients referred for diagnostic upper GI endoscopy. Forty-six percent of upper GI endoscopies were judged to be appropriate, 15% uncertain, and 39% inappropriate by the explicit criteria. No cancer was found in upper GI endoscopies judged to be inappropriate. Upper GI endoscopies judged appropriate or uncertain yielded significantly more relevant lesions (60%) than did those judged to be inappropriate (37%; odds ratio 2.6: 95% CI [2.2, 3.2]). In multivariate analyses, the diagnostic yield of upper GI endoscopy was significantly influenced by appropriateness, patient gender and age, treatment setting, and symptoms. CONCLUSIONS: Upper GI endoscopies performed for appropriate indications resulted in detecting significantly more clinically relevant lesions than did those performed for inappropriate indications. In addition, no upper GI endoscopy that resulted in a diagnosis of cancer was judged to be inappropriate. The use of such criteria improves patient selection for upper GI endoscopy and can thus contribute to efforts aimed at enhancing the quality and efficiency of care. (Gastrointest Endosc 2000;52:333-41).
Resumo:
Objectives: To determine characteristics of older patients referred to a geriatric outpatient clinic; 2) to determine the prevalence of geriatric syndromes in this population; 3) to identify main recommendations made to referring primary care physicians. Design: Cross-sectional analysis Setting: Outpatient clinic of the service of geriatric medicine at the University of Lausanne Medical Center, Lausanne, Switzerland. Participants: Community-dwelling patients aged 65 and over referred to the clinic. Measurements: Demographics, social, functional and health status data, main diagnoses identified and recommendations made for primary care physicians were collected prospectively. Results: Subjects (N=206, mean age 79.7±7.6 years, 57.3% women, 48.5% living alone, 36.9% receiving formal home care) were referred by primary care physicians (76%), hospitalists (18%), or family members (7%). Main reasons for referral were request for comprehensive assessment, cognitive evaluation, and mobility assessment (45.2%, 26.2%, and 15.5%, respectively). 21.4% of patients are independent in Lawton's Instrumental ADL and 47.1% are independent in Katz's Basic ADL, and 57.3% of patients reported having fallen once or more over the last year. Overall, 76.2% of patients had gait and balance impairment, 72.8% cognitive impairment, 57.3% polypharmacy (≥6 drugs; median 6.5±3.9, IQR 4-8), 54.4% affective disorder, 48.3% osteoporosis, 45.1% urinary incontinence and 33.8% orthostatic hypotension. Polymorbidity (≥6 geriatric syndromes) was present in 58.3% of referred patients. On average, patients received 10.6±4.0 recommendations, including fall prevention interventions (85.2 % of patients: walking aid adaptation in 48.1%, vitamin D prescription in 59.7%, home hazards assessment in 59.2%, and exercise prescription in 53.4%), referral to a memory clinic (45.6%), and treatment modifications (69.9 % of all patients and 81.6% of patients with polypharmacy, mostly psychotropic drugs discontinuation). Conclusions: Polymorbidity was frequent in these older outpatients, with polypharmacy, mobility and cognitive impairments being most prevalent. Outpatient geriatric consultation is a good opportunity to identify geriatric syndromes and propose interventions to prevent or delay functional decline.
Resumo:
Estimating the time since the last discharge of firearms and/or spent cartridges may be a useful piece of information in forensic firearm-related cases. The current approach consists of studying the diffusion of selected volatile organic compounds (such as naphthalene) released during the shooting using solid phase micro-extraction (SPME). However, this technique works poorly on handgun car-tridges because the extracted quantities quickly fall below the limit of detection. In order to find more effective solutions and further investigate the aging of organic gunshot residue after the discharge of handgun cartridges, an extensive study was carried out in this work using a novel approach based on high capacity headspace sorptive extraction (HSSE). By adopting this technique, for the first time 51 gunshot residue (GSR) volatile organic compounds could be simultaneously detected from fired handgun cartridge cases. Application to aged specimens showed that many of those compounds presented significant and complementary aging profiles. Compound-to-compound ratios were also tested and proved to be beneficial both in reducing the variability of the aging curves and in enlarging the time window useful in a forensic casework perspective. The obtained results were thus particularly promising for the development of a new complete forensic dating methodology.
Resumo:
Immunotherapy with monoclonal and polyclonal immunoglobulin is successfully applied to improve many clinical conditions, including infection, autoimmune diseases, or immunodeficiency. Most immunoglobulin products, recombinant or plasma-derived, are based on IgG antibodies, whereas to date, the use of IgA for therapeutic application has remained anecdotal. In particular, purification or production of large quantities of secretory IgA (SIgA) for potential mucosal application has not been achieved. In this work, we sought to investigate whether polymeric IgA (pIgA) recovered from human plasma is able to associate with secretory component (SC) to generate SIgA-like molecules. We found that ∼15% of plasma pIgA carried J chain and displayed selective SC binding capacity either in a mixture with monomeric IgA (mIgA) or after purification. The recombinant SC associated covalently in a 1:1 stoichiometry with pIgA and with similar efficacy as colostrum-derived SC. In comparison with pIgA, the association with SC delayed degradation of SIgA by intestinal proteases. Similar results were obtained with plasma-derived IgM. In vitro, plasma-derived IgA and SIgA neutralized Shigella flexneri used as a model pathogen, resulting in a delay of bacteria-induced damage targeted to polarized Caco-2 cell monolayers. The sum of these novel data demonstrates that association of plasma-derived IgA or IgM with recombinant/colostrum-derived SC is feasible and yields SIgA- and SIgM-like molecules with similar biochemical and functional characteristics as mucosa-derived immunoglobulins.