119 resultados para Extensor Muscles

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present pilot study evaluated the effect of botulinum toxin A on primarily non-dystonic tremors using accelerometry in a single-blind, placebo-controlled design. Resting, postural, intention, or head tremor were assessed before and approximately 1 month after intramuscular saline and botulinum toxin A (25-50 U) respectively. Half of the patients showed > or = 30% placebo effect. Tremor in 10 of 17 patients (60%) studied improved further after botulinum toxin A (range 30-95%), exceeding the placebo effect by > or = 30%. Nine patients demonstrated clinically significant focal weakness in the extensor muscles after botulinum toxin A which interfered with fine movements. Patients were subdivided into PD-like and ET-like tremor(s). Both groups experienced large placebo effects for resting tremor, with little or no further improvement after botulinum toxin A. The improvement in postural tremor after botulinum toxin A, of 40% in the PD-like and 57% in the ET-like groups, however, was approximately twice that of placebo. In conclusion, botulinum toxin A exerts a modest tremorlytic effect, however the dose, and its distribution over the sites injected, need to be optimised to minimise focal weakness.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In previous years, several publications have reported cases of infants presenting neurological and gastrointestinal symptoms after ingestion of star anise tea. Such teas are sometimes given in various cultures for the treatment of infant colic pains. In most cases, the cause of intoxication was contamination of Chinese star anise (Illicium verum) by Japanese star anise (Illicium anisatum). Indeed, the toxicity of Illicium anisatum, also known as Shikimi, is caused by its content in potent neurotoxins (anisatin, neoanisatin, and pseudoanisatin), due to their activity as non-competitive antagonists of GABA receptors. The main reasons explaining the frequent contaminations are the strong macroscopic resemblance of the 2 substances, as well as the fact that the fruits are often sold partially broken or in ground form. Therefore, in most cases, chemical analysis is required to determine the possible adulterations. CASE REPORT: A 2-month-old infant, in good general health, was brought to the emergency unit after 3 consecutive episodes of central cyanosis and tetany of the limbs with spontaneous recovery the same afternoon. The child was also very irritable, regurgitated a lot, and positioned himself in opisthotonos. Between these episodes, the neurological exam showed some perturbations (horizontal nystagmus and Bell's phenomenon, hypertony of the extensor muscles, and mild hypotony of the axial flexor muscles) with slow improvement over the following hours. The remaining clinical exam, the laboratory work (complete blood count, renal, hepatic, and muscular tests, capillary blood gas, plasmatic amino acids, and urinary organic acids), and the electroencephalogram findings were all normal. In the course of a detailed interview, the parents reported having given 3 bottles to their child, each one containing 200 mL of an infusion with 4 to 5 fruits of star anise, in the hours preceding the symptoms to relieve colic pains. The last seizure-like event took place approximately 8h after the last ingestion. We could prove the ingestion of anisatin, the toxic substance found in Japanese star anise, and the contamination of Chinese star anise by the Japanese species. Indeed, the anisatin analysis by liquid chromatography and mass spectroscopy (LC-MS) in a urine sample taken 22 h after the last infusion ingestion showed trace amounts of the substance. In another urine sample taken 33 h after ingestion, no anisatin could be detected. Furthermore, the analysis of the fruit sample gave an anisatin concentration of 7800 μg/kg while the maximum tolerance value in Switzerland is 1000 μg/kg. CONCLUSION: The evaluation of ALTE in infants should always include the possibility of intoxication. Star anise is generally considered a harmless medicine. Nevertheless, it can sometimes cause a severe intoxication resulting in various neurological and gastrointestinal symptoms. To prevent such events, not only the parents, but also the care personnel and pharmacists must be informed about the possible adverse effects caused either by the overdose of Chinese star anise or by the eventual contamination of herbal teas with Japanese star anise. A better control of the substances by the health authorities is also necessary.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the study was to test the hypothesis of the involvement of type II fibres in the V.O (2) slow component phenomenon by using two prior fatiguing protocols on the knee extensor muscles. Nine subjects performed three constant-load cycling exercises at a work rate corresponding to 80 % of their V.O (2) max: (i) preceded by a 20-min fatiguing protocol using electromyostimulation (EMS), (ii) preceded by a 20-min fatiguing protocol using voluntary contractions (VOL), and (iii) without fatiguing protocol (NFP). Voluntary and evoked neuromuscular properties of the knee extensor muscles were tested before (PRE) and after (POST) the two fatiguing protocols. Results show a significant reduction in voluntary force after both fatiguing protocols (-19.9 % and -11.8 %, in EMS and VOL, respectively p<0.01). After EMS, this decrease was greater than after VOL (p<0.05) and was combined with a slackening of muscle contractile properties which was absent after VOL (p<0.05). Regarding the effects on oxygen uptake kinetics, the appearance of the slow component was delayed after EMS and its amplitude was lower than those obtained in VOL and NFP conditions (0.48+/-0.07 vs. 0.75+/-0.09 and 0.69+/-0.08 L . min (-1), respectively; p<0.05). It can thus be concluded that exercises dedicated to preferentially fatiguing type II fibres may alter V.O (2) kinetics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It has been already demonstrated that thyroid hormone (T3) is one of the most important stimulating factors in peripheral nerve regeneration. We have recently shown that local administration of T3 in silicon tubes at the level of the transected rat sciatic nerve enhanced axonal regeneration and improved functional recovery. Silicon, however, cannot be used in humans because it causes a chronic inflammatory reaction. Therefore, in order to provide future clinical applications of thyroid hormone in human peripheral nerve lesions, we carried out comparative studies on the regeneration of transected rat sciatic nerve bridged either by biodegradable P(DLLA-(-CL) or by silicon nerve guides, both guides filled with either T3 or phosphate buffer. Our macroscopic observation revealed that 85% of the biodegradable guides allowed the expected regeneration of the transected sciatic nerve. The morphological, morphometric and electrophysiological analysis showed that T3 in biodegradable guides induces a significant increase in the number of myelinated regenerated axons (6862 +/- 1831 in control vs. 11799 +/- 1163 in T3-treated). Also, T3 skewed the diameter of myelinated axons toward larger values than in controls. Moreover, T3 increases the compound muscle action potential amplitude of the flexor and extensor muscles of the treated rats. This T3 stimulation in biodegradable guides was equally well to that obtained by using silicone guides. In conclusion, the administration of T3 in biodegradable guides significantly improves sciatic nerve regeneration, confirming the feasibility of our technique to provide a serious step towards future clinical application of T3 in human peripheral nerve injuries.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The alteration in neuromuscular function of knee extensor muscles was characterised after a squash match in 10 trained players. Maximal voluntary contraction (MVC) and surface EMG activity of vastus lateralis (VL) and vastus medialis (VM) muscles were measured before and immediately after a 1-h squash match. M-wave and twitch contractile properties were analysed following single stimuli. MVC declined (280.5+/-46.8 vs. 233.6+/-35.4 Nm, -16%; P<0.001) after the exercise and this was accompanied by an impairment of central activation, as attested by decline in voluntary activation (76.7+/-10.4 vs. 71.3+/-9.6%, -7%; P<0.05) and raw EMG activity of the two vastii (-17%; P<0.05), whereas RMS/M decrease was lesser (VL: -5%; NS and VM: -12%; P=0.10). In the fatigued state, no significant changes in M-wave amplitude (VL: -9%; VM: -5%) or duration were observed. Following exercise, the single twitch was characterised by lower peak torque (-20%; P<0.001) as well as shorter half-relaxation time (-13%; P<0.001) and reduced maximal rate of twitch tension development (-23%; P<0.001) and relaxation (-17%; P<0.05). A 1-h squash match play caused peripheral fatigue by impairing excitation-contraction coupling, whereas sarcolemmal excitability seems well preserved. Our results also emphasise the role of central activation failure as a possible mechanism contributing to the torque loss observed in knee extensors. Physical conditioners should consider these effects when defining their training programs for squash players.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: First, to report ECU subsheath's normal MRI appearance and the findings in athletic injuries. Second, to determine the best MRI sequence for diagnosis. Methods and materials: Sixteen patients (13 males, 3 females, mean age 30.3 years) with ECU subsheath's athletic injuries sustained between January 2003 and June 2009 were retrospectively reviewed. Wrist MRI studies were performed on 1.5-T units and consisted of at least transverse T1 and STIR sequences in pronation, and FS Gd T1 in pronation and supination. Two radiologists assessed the following items, in consensus: injury type (A to C according to Inoue), ECU tendon stability, and associated lesions (ulnar head oedema, extensor retinaculum injury, ECU tendinosis and tenosynovitis). Then, each reader independently rated the sequences' diagnostic value: 0 = questionable, 1 = suggestive, 2 = certain. Follow-up studies were present in 8 patients. ECU subsheath's normal visibility (medial, central and lateral parts) was retrospectively evaluated in 30 consecutive control MRI studies. Results: FS Gd T1 sequences in supination (1.63) and pronation (1.59) were the most valuable for diagnosis, compared to STIR (1.22) and T1 (1). The study group included 9 type A, 1 type B and 6 type C injuries. There were trends towards diminution in pouches' size, signal intensity and enhancement in follow-up studies, along with tendon stabilization within the ulnar groove. In control studies, ECU subsheath's visibility in medial, central and lateral parts were noted in 66.7-80%, 63.3-80% and 30-50% respectively. Conclusion: ECU subsheath's athletic injuries are visible on 1.5-T MRI studies. FS Gd T1 sequences in supination and pronation are the most valuable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mice in which peroxisome proliferator-activated receptor beta (PPARbeta) is selectively ablated in skeletal muscle myocytes were generated to elucidate the role played by PPARbeta signaling in these myocytes. These somatic mutant mice exhibited a muscle fiber-type switching toward lower oxidative capacity that preceded the development of obesity and diabetes, thus demonstrating that PPARbeta is instrumental in myocytes to the maintenance of oxidative fibers and that fiber-type switching is likely to be the cause and not the consequence of these metabolic disorders. We also show that PPARbeta stimulates in myocytes the expression of PGC1alpha, a coactivator of various transcription factors, known to play an important role in slow muscle fiber formation. Moreover, as the PGC1alpha promoter contains a PPAR response element, the effect of PPARbeta on the formation and/or maintenance of slow muscle fibers can be ascribed, at least in part, to a stimulation of PGC1alpha expression at the transcriptional level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To report the MRI features of ECU accessory tendinous slips, assess their observable prevalence and evaluate a potential link between this anatomical variation and ECU tenosynovitis or tendinopathy. Methods and materials: Institutional review board approved this retrospective study, with waiver of patient informed consent. One hundred sixty wrist MRI studies from 158 patients (85 females, 73 males, mean age 45.6 years, range 14-86) performed between March 2008 and February 2009 on a 1.5-T unit were included. MR images were analyzed by two radiologists in consensus. The observable prevalence of ECU accessory tendinous slips was assessed and their origin, diameter and insertion sites were noted. The presence of ECU tenosynovitis and/or tendinopathy was also evaluated. Results: The observable prevalence of ECU accessory tendinous slips was 21.9% (35/160). The origin was always seen: 8 were at the level of, and 27 distal to the ECU subsheath. The slip median diameter was 0.67 mm (range 0.43-0.88). The insertion was seen in 17.1% (6/35): 2 were on the fifth metacarpal bone, 4 on the extensor apparatus of the fifth finger. ECU tenosynovitis (20%), tendinopathy (5.7%) as well as concomitant tenosynovitis and tendinopathy (25.7%) were more frequently encountered in the patients with the anatomical variation than in the control patients group (0.8%, 3.2% and 9.6% respectively). Differences were statistically significant for tenosynovitis (p = 0.0001) and concomitant tenosynovitis and tendinopathy (p = 0.02) of the ECU. Conclusion: ECU accessory tendinous slips are frequent and visible on 1.5-T wrist MRI studies. ECU tenosynovitis and tendinopathy are more frequent in patients bearing this anatomical variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the physiological consequences of the most challenging mountain ultra-marathon (MUM) in the world: a 330-km trail run with 24000 m of positive and negative elevation change. Neuromuscular fatigue (NMF) was assessed before (Pre-), during (Mid-) and after (Post-) the MUM in experienced ultra-marathon runners (n = 15; finish time  = 122.43 hours ±17.21 hours) and in Pre- and Post- in a control group with a similar level of sleep deprivation (n = 8). Blood markers of muscle inflammation and damage were analyzed at Pre- and Post-. Mean ± SD maximal voluntary contraction force declined significantly at Mid- (-13±17% and -10±16%, P<0.05 for knee extensor, KE, and plantar flexor muscles, PF, respectively), and further decreased at Post- (-24±13% and -26±19%, P<0.01) with alteration of the central activation ratio (-24±24% and -28±34% between Pre- and Post-, P<0.05) in runners whereas these parameters did not change in the control group. Peripheral NMF markers such as 100 Hz doublet (KE: -18±18% and PF: -20±15%, P<0.01) and peak twitch (KE: -33±12%, P<0.001 and PF: -19±14%, P<0.01) were also altered in runners but not in controls. Post-MUM blood concentrations of creatine kinase (3719±3045 Ul·(1)), lactate dehydrogenase (1145±511 UI·L(-1)), C-Reactive Protein (13.1±7.5 mg·L(-1)) and myoglobin (449.3±338.2 µg·L(-1)) were higher (P<0.001) than at Pre- in runners but not in controls. Our findings revealed less neuromuscular fatigue, muscle damage and inflammation than in shorter MUMs. In conclusion, paradoxically, such extreme exercise seems to induce a relative muscle preservation process due likely to a protective anticipatory pacing strategy during the first half of MUM and sleep deprivation in the second half.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To report the magnetic resonance imaging (MRI) findings in athletic injuries of the extensor carpi ulnaris (ECU) subsheath, assessing the utility of gadolinium-enhanced (Gd) fat-saturated (FS) T1-weighted sequences with wrist pronation and supination. Methods and Materials: Sixteen patients (13 males, 3 females; mean age 30.3 years) with athletic injuries of the ECU subsheath sustained between January 2003 and June 2009 were included in this retrospective study. Initial and follow‑up 1.5-T wrist MRIs were performed with transverse T1-weighted and STIR sequences in pronation, and Gd FS T1-weighted sequences with wrist pronation and supination. Two radiologists assessed the type of injury (A to C), ECU tendon stability, associated lesions and rated pulse sequences using a three-point scale: 1 = poor, 2 = good and 3 = excellent. Results: Gd-enhanced FS T1-weighted transverse sequences in supination (2.63) and pronation (2.56) were most valuable, compared with STIR (2.19) and T1 weighted (1.94). Nine type A, one type B and six type C injuries were found. There were trends towards diminution in size, signal intensity and enhancement of associated pouches on follow‑up MRI and tendon stabilisation within the ulnar groove. Conclusion: Gd-enhanced FS T1-weighted sequences with wrist pronation and supination are most valuable in assessing and follow‑up athletic injuries of the ECU subsheath on 1.5-T MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

C57BL/6J mice were fed a high-fat, carbohydrate-free diet (HFD) for 9 mo. Approximately 50% of the mice became obese and diabetic (ObD), approximately 10% lean and diabetic (LD), approximately 10% lean and nondiabetic (LnD), and approximately 30% displayed intermediate phenotype. All of the HFD mice were insulin resistant. In the fasted state, whole body glucose clearance was reduced in ObD mice, unchanged in the LD mice, and increased in the LnD mice compared with the normal-chow mice. Because fasted ObD mice were hyperinsulinemic and the lean mice slightly insulinopenic, there was no correlation between insulin levels and increased glucose utilization. In vivo, tissue glucose uptake assessed by 2-[(14)C]deoxyglucose accumulation was reduced in most muscles in the ObD mice but increased in the LnD mice compared with the values of the control mice. In the LD mice, the glucose uptake rates were reduced in extensor digitorum longus (EDL) and total hindlimb but increased in soleus, diaphragm, and heart. When assessed in vitro, glucose utilization rates in the absence and presence of insulin were similar in diaphragm, soleus, and EDL muscles isolated from all groups of mice. Thus, in genetically homogenous mice, HFD feeding lead to different metabolic adaptations. Whereas all of the mice became insulin resistant, this was associated, in obese mice, with decreased glucose clearance and hyperinsulinemia and, in lean mice, with increased glucose clearance in the presence of mild insulinopenia. Therefore, increased glucose clearance in lean mice could not be explained by increased insulin level, indicating that other in vivo mechanisms are triggered to control muscle glucose utilization. These adaptive mechanisms could participate in the protection against development of obesity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.