6 resultados para Exhalation
em Université de Lausanne, Switzerland
Resumo:
INTRODUCTION. NAVA is a new spontaneous-assisted ventilatory mode based on thedetection of diaphragmatic electrical activity (Eadi) and its feedback to adjust ventilatorsettings. NAVA uses the Eadi, an expression of the respiratory center's activity, to initiatepressurization, set the level of pressure support and cycle the ventilator into exhalation.Therefore, NAVA should theoretically allow near-perfect synchronization between the patientand the ventilator. However there are few data documenting these effects in intensive carepatients.OBJECTIVES. To determine whether NAVA can improve patient-ventilator synchronycompared to standard pressure support (PS) in intubated intensive care patients.METHODS. Comparative study of patient-ventilator interaction during PS with cliniciandetermined ventilator settings and NAVA with NAVA gain (proportionality factor betweenEadi and the amount of delivered inspiratory pressure) set as to obtain the same peak airwaypressure as the total pressure obtained in PS. A 20 min continuous recording with eachventilatory mode was performed allowing determination of trigger delay (Td), patient neuralinspiratory time (Tin), duration of pressurization by the ventilator (Tiv), excess durationof pressurization (Ti excess = Tiv - Tin/Tin 9 100) and number of asynchrony events byminute: non-triggering breaths, auto-triggering, double triggering, premature and delayedcycling.Results are given in mean ± SD. p is considered significant if\0.05.RESULTS. Preliminary results (mean ± SD): five patients (age 75 ± 12 years, 1 M/4F,BMI 25.7 ± 4.1 kg m-2), two pts with COPD, 1 with restrictive disease, initial settings: PS14.6 ± 1.7 cm H2O, PEEP 6.4 ± 1.5 cm H2O, NAVA gain 2.8 ± 1.3PS NAVA % reduction NAVAversus PSTd (ms) 210.4 ± 63.0 51.8 ± 12.1* 74.5 ± 5.0Ti excess (%) 12.9 ± 19.6 2.2 ± 0.6 70.8 ± 37.8n asynchrony/minute 7.6 ± 6.4 4.1 ± 3.7* 47.5 ± 17.0Respiratory rate (min-1) 16.8 ± 2.6 20.4 ± 4.7 NA* p\0.05CONCLUSION. Compared to standard PS, NAVA improves patient ventilator interaction byreducing Td and the overall incidence of asynchrony events. There is also a strong trend inreducing delayed cycling. This ongoing trial should provide evidence that NAVA can indeedimprove patient-ventilator synchrony in intubated patients undergoing PS.REFERENCE(S). 1. Sinderby C, Navalesi P et al (1995) Neural control of mechanicalventilation in respiratory failure. Nat Med 5(12):1433-1436.2. Colombo D, Cammarota G et al (2008) Physiologic response to varying levels of pressuresupport and neurally adjusted ventilator assist in patients with acute respiratory failure.Intensive Care Med 34(11):2010-2018.
Resumo:
The aim of this pilot project was to evaluate the feasibility of assessing the deposited particle dose in the lungs by applying the dynamic light scattering-based methodology in exhaled breath condensateur (EBC). In parallel, we developed and validated two analytical methods allowing the determination of inflammatory (hydrogen peroxide - H2O2) and lipoperoxidation (malondialdehyde - MDA) biomarkers in exhaled breath condensate. Finally, these methods were used to assess the particle dose and consecutive inflammatory effect in healthy nonsmoker subjects exposed to environmental tobacco smoke in controlled situations was done.
Resumo:
Invasive studies suggest that healthy children living at high altitude display pulmonary hypertension, but the data to support this assumption are sparse. Nitric oxide (NO) synthesized by the respiratory epithelium regulates pulmonary artery pressure, and its synthesis was reported to be increased in Aymara high-altitude dwellers. We hypothesized that pulmonary artery pressure will be lower in Aymara children than in children of European ancestry at high altitude, and that this will be related to increased respiratory NO. We therefore compared pulmonary artery pressure and exhaled NO (a marker of respiratory epithelial NO synthesis) between large groups of healthy children of Aymara (n = 200; mean +/- SD age, 9.5 +/- 3.6 years) and European ancestry (n = 77) living at high altitude (3,600 to 4,000 m). We also studied a group of European children (n = 29) living at low altitude. The systolic right ventricular to right atrial pressure gradient in the Aymara children was normal, even though significantly higher than the gradient measured in European children at low altitude (22.5 +/- 6.1 mm Hg vs 17.7 +/- 3.1 mm Hg, p < 0.001). In children of European ancestry studied at high altitude, the pressure gradient was 33% higher than in the Aymara children (30.0 +/- 5.3 mm Hg vs 22.5 +/- 6.1 mm Hg, p < 0.0001). In contrast to what was expected, exhaled NO tended to be lower in Aymara children than in European children living at the same altitude (12.4 +/- 8.8 parts per billion [ppb] vs 16.1 +/- 11.1 ppb, p = 0.06) and was not related to pulmonary artery pressure in either group. Aymara children are protected from hypoxic pulmonary hypertension at high altitude. This protection does not appear to be related to increased respiratory NO synthesis.
Resumo:
Health assessment and medical surveillance of workers exposed to combustion nanoparticles are challenging. The aim was to evaluate the feasibility of using exhaled breath condensate (EBC) from healthy volunteers for (1) assessing the lung deposited dose of combustion nanoparticles and (2) determining the resulting oxidative stress by measuring hydrogen peroxide (H2O2) and malondialdehyde (MDA). Methods: Fifteen healthy nonsmoker volunteers were exposed to three different levels of sidestream cigarette smoke under controlled conditions. EBC was repeatedly collected before, during, and 1 and 2 hr after exposure. Exposure variables were measured by direct reading instruments and by active sampling. The different EBC samples were analyzed for particle number concentration (light-scattering-based method) and for selected compounds considered oxidative stress markers. Results: Subjects were exposed to an average airborne concentration up to 4.3×10(5) particles/cm(3) (average geometric size ∼60-80 nm). Up to 10×10(8) particles/mL could be measured in the collected EBC with a broad size distribution (50(th) percentile ∼160 nm), but these biological concentrations were not related to the exposure level of cigarette smoke particles. Although H2O2 and MDA concentrations in EBC increased during exposure, only H2O2 showed a transient normalization 1 hr after exposure and increased afterward. In contrast, MDA levels stayed elevated during the 2 hr post exposure. Conclusions: The use of diffusion light scattering for particle counting proved to be sufficiently sensitive to detect objects in EBC, but lacked the specificity for carbonaceous tobacco smoke particles. Our results suggest two phases of oxidation markers in EBC: first, the initial deposition of particles and gases in the lung lining liquid, and later the start of oxidative stress with associated cell membrane damage. Future studies should extend the follow-up time and should remove gases or particles from the air to allow differentiation between the different sources of H2O2 and MDA.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.