40 resultados para Excellent performance

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microsatellite instability (MSI) occurs in 10-20% of colorectal tumours and is associated with good prognosis. Here we describe the development and validation of a genomic signature that identifies colorectal cancer patients with MSI caused by DNA mismatch repair deficiency with high accuracy. Microsatellite status for 276 stage II and III colorectal tumours has been determined. Full-genome expression data was used to identify genes that correlate with MSI status. A subset of these samples (n = 73) had sequencing data for 615 genes available. An MSI gene signature of 64 genes was developed and validated in two independent validation sets: the first consisting of frozen samples from 132 stage II patients; and the second consisting of FFPE samples from the PETACC-3 trial (n = 625). The 64-gene MSI signature identified MSI patients in the first validation set with a sensitivity of 90.3% and an overall accuracy of 84.8%, with an AUC of 0.942 (95% CI, 0.888-0.975). In the second validation, the signature also showed excellent performance, with a sensitivity 94.3% and an overall accuracy of 90.6%, with an AUC of 0.965 (95% CI, 0.943-0.988). Besides correct identification of MSI patients, the gene signature identified a group of MSI-like patients that were MSS by standard assessment but MSI by signature assessment. The MSI-signature could be linked to a deficient MMR phenotype, as both MSI and MSI-like patients showed a high mutation frequency (8.2% and 6.4% of 615 genes assayed, respectively) as compared to patients classified as MSS (1.6% mutation frequency). The MSI signature showed prognostic power in stage II patients (n = 215) with a hazard ratio of 0.252 (p = 0.0145). Patients with an MSI-like phenotype had also an improved survival when compared to MSS patients. The MSI signature was translated to a diagnostic microarray and technically and clinically validated in FFPE and frozen samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L'expérience Belle, située dans le centre de recherche du KEK, au Japon, est consacrée principalement à l'étude de la violation de CP dans le système des mésons B. Elle est placée sur le collisionneur KEKB, qui produit des paires Banti-B. KEKB, l'une des deux « usines à B » actuellement en fonction, détient le record du nombre d'événements produits avec plus de 150 millions de paires. Cet échantillon permet des mesures d'une grande précision dans le domaine de la physique du méson B. C'est dans le cadre de ces mesures de précision que s'inscrit cette analyse. L'un des phénomènes remarquables de la physique des hautes énergies est la faculté qu'a l'interaction faible de coupler un méson neutre avec son anti-méson. Dans le présent travail, nous nous intéressons au méson B neutre couplé à l'anti-méson B neutre, avec une fréquence d'oscillation _md mesurable précisément. Outre la beauté de ce phénomène lui-même, une telle mesure trouve sa place dans la quête de l'origine de la violation de CP. Cette dernière n'est incluse que d'une façon peu satisfaisante dans le modèle standard des interactions électro-faibles. C'est donc la recherche de phénomènes physiques encore inexpliqués qui motive en premier lieu la collaboration Belle. Il existe déjà de nombreuses mesures de _md antérieures. Celle que nous présentons ici est cependant d'une précision encore jamais atteinte grâce, d'une part, à l'excellente performance de KEKB et, d'autre part, à une approche originale qui permet de réduire considérablement la contamination de la mesure par des événements indésirés. Cette approche fut déjà mise à profit par d'autres expériences, dans des conditions quelque peu différentes de celles de Belle. La méthode utilisée consiste à reconstruire partiellement l'un des mésons dans le canal ___D*(D0_)l_l, en n'utilisant que les informations relatives au lepton l et au pion _. L'information concernant l'autre méson de la paire Banti-B initiale n'est tirée que d'un seul lepton de haute énergie. Ainsi, l'échantillon à disposition ne souffre pas de grandes réductions dues à une reconstruction complète, tandis que la contamination due aux mésons B chargés, produits par KEKB en quantité égale aux B0, est fortement diminuée en comparaison d'une analyse inclusive. Nous obtenons finalement le résultat suivant : _md = 0.513±0.006±0.008 ps^-1, la première erreur étant l'erreur statistique et la deuxième, l'erreur systématique.<br/><br/>The Belle experiment is located in the KEK research centre (Japan) and is primarily devoted to the study of CP violation in the B meson sector. Belle is placed on the KEKB collider, one of the two currently running "B-meson factories", which produce Banti-B pairs. KEKB has created more than 150 million pairs in total, a world record for this kind of colliders. This large sample allows very precise measurements in the physics of beauty mesons. The present analysis falls within the framework of these precise measurements. One of the most remarkable phenomena in high-energy physics is the ability of weak interactions to couple a neutral meson to its anti-meson. In this work, we study the coupling of neutral B with neutral anti-B meson, which induces an oscillation of frequency _md we can measure accurately. Besides the interest of this phenomenon itself, this measurement plays an important role in the quest for the origin of CP violation. The standard model of electro-weak interactions does not include CP violation in a fully satisfactory way. The search for yet unexplained physical phenomena is, therefore, the main motivation of the Belle collaboration. Many measurements of _md have previously been performed. The present work, however, leads to a precision on _md that was never reached before. This is the result of the excellent performance of KEKB, and of an original approach that allows to considerably reduce background contamination of pertinent events. This approach was already successfully used by other collaborations, in slightly different conditions as here. The method we employed consists in the partial reconstruction of one of the B mesons through the decay channel ___D*(D0_)l_l, where only the information on the lepton l and the pion _ are used. The information on the other B meson of the initial Banti-B pair is extracted from a single high-energy lepton. The available sample of Banti-B pairs thus does not suffer from large reductions due to complete reconstruction, nor does it suffer of high charged B meson background, as in inclusive analyses. We finally obtain the following result: _md = 0.513±0.006±0.008 ps^-1, where the first error is statistical, and the second, systematical.<br/><br/>De quoi la matière est-elle constituée ? Comment tient-elle ensemble ? Ce sont là les questions auxquelles la recherche en physique des hautes énergies tente de répondre. Cette recherche est conduite à deux niveaux en constante interaction. D?une part, des modèles théoriques sont élaborés pour tenter de comprendre et de décrire les observations. Ces dernières, d?autre part, sont réalisées au moyen de collisions à haute énergie de particules élémentaires. C?est ainsi que l?on a pu mettre en évidence l?existence de quatre forces fondamentales et de 24 constituants élémentaires, classés en « quarks » et « leptons ». Il s?agit là de l?une des plus belles réussites du modèle en usage aujourd?hui, appelé « Modèle Standard ». Il est une observation fondamentale que le Modèle Standard peine cependant à expliquer, c?est la disparition quasi complète de l?anti-matière (le « négatif » de la matière). Au niveau fondamental, cela doit correspondre à une asymétrie entre particules (constituants de la matière) et antiparticules (constituants de l?anti-matière). On l?appelle l?asymétrie (ou violation) CP. Bien qu?incluse dans le Modèle Standard, cette asymétrie n?est que partiellement prise en compte, semble-t-il. En outre, son origine est inconnue. D?intenses recherches sont donc aujourd?hui entreprises pour mettre en lumière cette asymétrie. L?expérience Belle, au Japon, en est une des pionnières. Belle étudie en effet les phénomènes physiques liés à une famille de particules appelées les « mésons B », dont on sait qu?elles sont liées de près à l?asymétrie CP. C?est dans le cadre de cette recherche que se place cette thèse. Nous avons étudié une propriété remarquable du méson B neutre : l?oscillation de ce méson avec son anti-méson. Cette particule est de se désintégrer pour donner l?antiparticule associée. Il est clair que cette oscillation est rattachée à l?asymétrie CP. Nous avons ici déterminé avec une précision encore inégalée la fréquence de cette oscillation. La méthode utilisée consiste à caractériser une paire de mésons B à l?aide de leur désintégration comprenant un lepton chacun. Une plus grande précision est obtenue en recherchant également une particule appelée le pion, et qui provient de la désintégration d?un des mésons. Outre l?intérêt de ce phénomène oscillatoire en lui-même, cette mesure permet d?affiner, directement ou indirectement, le Modèle Standard. Elle pourra aussi, à terme, aider à élucider le mystère de l?asymétrie entre matière et anti-matière.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coxiella burnetii and members of the genus Rickettsia are obligate intracellular bacteria. Since cultivation of these organisms requires dedicated techniques, their diagnosis usually relies on serological or molecular biology methods. Immunofluorescence is considered the gold standard to detect antibody-reactivity towards these organisms. Here, we assessed the performance of a new automated epifluorescence immunoassay (InoDiag) to detect IgM and IgG against C. burnetii, Rickettsia typhi and Rickettsia conorii. Samples were tested with the InoDiag assay. A total of 213 sera were tested, of which 63 samples from Q fever, 20 from spotted fever rickettsiosis, 6 from murine typhus and 124 controls. InoDiag results were compared to micro-immunofluorescence. For acute Q fever, the sensitivity of phase 2 IgG was only of 30% with a cutoff of 1 arbitrary unit (AU). In patients with acute Q fever with positive IF IgM, sensitivity reached 83% with the same cutoff. Sensitivity for chronic Q fever was 100% whereas sensitivity for past Q fever was 65%. Sensitivity for spotted Mediterranean fever and murine typhus were 91% and 100%, respectively. Both assays exhibited a good specificity in control groups, ranging from 79% in sera from patients with unrelated diseases or EBV positivity to 100% in sera from healthy patients. In conclusion, the InoDiag assay exhibits an excellent performance for the diagnosis of chronic Q fever but a very low IgG sensitivity for acute Q fever likely due to low reactivity of phase 2 antigens present on the glass slide. This defect is partially compensated by the detection of IgM. Because it exhibits a good negative predictive value, the InoDiag assay is valuable to rule out a chronic Q fever. For the diagnosis of rickettsial diseases, the sensitivity of the InoDiag method is similar to conventional immunofluorescence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Falls efficacy, defined as confidence in performing activities without falling, is a measure of fear of falling associated with gait impairment, falls and functional decline in frail older people. This relationship has not been well studied in high-functioning older people. Objective: To evaluate the relationship between falls efficacy and gait performance in a cohort of high-functioning older people. Methods: Subjects (N = 864) were a subsample of communitydwelling older people aged 65 to 70 years, enrolled in the "Lc65+" cohort, who completed gait assessment at baseline. Data were collected on demographics, functional, cognitive, affective, and health status. Falls efficacy was assessed using the Falls Efficacy Scale- International (FES-I) that measures confidence in performing 16 activities of daily life (ADL) without falling (score from 16 to 64, higher score indicates lower confidence). Gait parameters were measured over a 20 m walk at preferred gait speed using Physilog, an ambulatory gait monitoring system. Results: Participants (mean age 68.0 ± 1.4 years, 55.0% women) had excellent physical (92.2% independent in basic ADL, mean gait speed 1.13 ± 0.16 m/sec) and cognitive (98.0% with MMSE 024) performance. Nevertheless, 22.1% reported depressive symptoms and 16.1% one or more fall in the previous year. Mean FES-I score was 18.8 ± 4.1. Falls efficacy was associated with gait speed (Spearman rho -0.23, P <.001) and gait variability (Spearman rho 0.10, P = .006), measured by the coefficient of variation of stride velocity. These associations remained in multivariate analysis for both gait speed (adj [beta] coeff: -0.008, 95%CI -0.005 to -0.010, P <.001) and gait variability (adj [beta] coeff 0.024, 95%CI 0.003 to 0.045, P = .023) independent of gender, falls, functional, affective, cognitive, and frailty (Fried's criteria) status. On average, compared to subjects with poor confidence in performing one ADL without falling, those with full confidence had a 0.02 m/sec (2%) faster gait speed and a 2% decrease in gait variability. Conclusion: Even in high-functioning older people, poor falls efficacy is associated with reduced gait speed and stability, independent of health, functional, and frailty status. The direction of this relationship needs to be investigated prospectively to determine causality and design interventions to improve gait performance, reduce fall risk, and prevent functional decline.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In many countries, primary care physicians determine whether or not older drivers are fit to drive. Little, however, is known regarding the effects of cognitive decline on driving performance and the means to detect it. This study explores to what extent the trail making test (TMT) can provide indications to clinicians about their older patients' on-road driving performance in the context of cognitive decline. METHODS: This translational study was nested within a cohort study and an exploratory psychophysics study. The target population of interest was constituted of older drivers in the absence of important cognitive or physical disorders. We therefore recruited and tested 404 home-dwelling drivers, aged 70 years or more and in possession of valid drivers' licenses, who volunteered to participate in a driving refresher course. Forty-five drivers also agreed to undergo further testing at our lab. On-road driving performance was evaluated by instructors during a 45 minute validated open-road circuit. Drivers were classified as either being excellent, good, moderate, or poor depending on their score on a standardized evaluation of on-road driving performance. RESULTS: The area under the receiver operator curve for detecting poorly performing drivers was 0.668 (CI95% 0.558 to 0.778) for the TMT-A, and 0.662 (CI95% 0.542 to 0.783) for the TMT-B. TMT was related to contrast sensitivity, motion direction, orientation discrimination, working memory, verbal fluency, and literacy. Older patients with a TMT-A ≥ 54 seconds or a TMT-B ≥ 150 seconds have a threefold (CI95% 1.3 to 7.0) increased risk of performing poorly during the on-road evaluation. TMT had a sensitivity of 63.6%, a specificity of 64.9%, a positive predictive value of 9.5%, and a negative predictive value of 96.9%. CONCLUSION: In screening settings, the TMT would have clinicians uselessly consider driving cessation in nine drivers out of ten. Given the important negative impact this could have on older drivers, this study confirms the TMT not to be specific enough for clinicians to justify driving cessation without complementary investigations on driving behaviors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Our institution (University hospital) is encouraging physical activities for health through various popular sporting events in the city of Lausanne, the biggest of which is a road race of 2, 4, 10 and 20km. Objective To create an efficient and sustainable training program in preparation of the race for a group of motivated hospital employees without any prior experience with structured training and to identifying the benefits and limitations encountered.. Methods Subjects of various fitness levels were recruited by add and agreed to undergo lab and field testing before a 12-week 3 times/week running program, based on maximal aerobic speed (MAS-30/30 sec intervals), running technique exercises and endurance training. The interval session was the only one supervised. Their goal was the 10km (11 subjects) and the 20km (6 subjects). Results A group of 17 subjects (7 male and 10 female), mean age 36.6±7.3 years, VO2max 44.0±5.5 ml/kg/min, filed test interval MAS 15.1±2.4 km/h started the program. 2 were lost because of injury (while skiing). Adherence to interval sessions was excellent, although 3 weekly training sessions proved to be difficult for most of the subjects. Performance in the race was satisfying for all of them, 6/7 subjects having improved their running time from the previous year, the others participated for the first time and 7/8 completed the race satisfyingly, one DNF-ed because of sinusitis. Repeat MAS field test was available for 6 subjects, who improved by 5.9% (p<0.01). Subjectively, all of the participants were very satisfied with improvement, interaction with colleagues from various professions, and with self achievement and confidence. Conclusions Implementation of a structured training program for recreational or non-athletes can be very successful in creating a better self-confidence, a better working environment inside a hospital facility and obviously in improvement of physical fitness and athletic performance. Above all, it can only encourage health institutions to promote the health of their own employees through physical activity, which can allow people to connect through sports. As a result, subjects in this study tend to encourage other employees to be more active and are hungry for more advice and continued offers for physical activities benefiting both them and the institution through better efficiency at work and less absenteeism common to more active people.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Therapy of chronic hepatitis C (CHC) with pegIFNa/ribavirin achieves sustained virologic response (SVR) in ~55%. Pre-activation of the endogenous interferon system in the liver is associated non-response (NR). Recently, genome-wide association studies described associations of allelic variants near the IL28B (IFNλ3) gene with treatment response and with spontaneous clearance of the virus. We investigated if the IL28B genotype determines the constitutive expression of IFN stimulated genes (ISGs) in the liver of patients with CHC. Methods: We genotyped 93 patients with CHC for 3 IL28B single nucleotide polymorphisms (SNPs, rs12979860, rs8099917, rs12980275), extracted RNA from their liver biopsies and quantified the expression of IL28B and of 8 previously identified classifier genes which discriminate between SVR and NR (IFI44L, RSAD2, ISG15, IFI22, LAMP3, OAS3, LGALS3BP and HTATIP2). Decision tree ensembles in the form of a random forest classifier were used to calculate the relative predictive power of these different variables in a multivariate analysis. Results: The minor IL28B allele (bad risk for treatment response) was significantly associated with increased expression of ISGs, and, unexpectedly, with decreased expression of IL28B. Stratification of the patients into SVR and NR revealed that ISG expression was conditionally independent from the IL28B genotype, i.e. there was an increased expression of ISGs in NR compared to SVR irrespective of the IL28B genotype. The random forest feature score (RFFS) identified IFI27 (RFFS = 2.93), RSAD2 (1.88) and HTATIP2 (1.50) expression and the HCV genotype (1.62) as the strongest predictors of treatment response. ROC curves of the IL28B SNPs showed an AUC of 0.66 with an error rate (ERR) of 0.38. A classifier with the 3 best classifying genes showed an excellent test performance with an AUC of 0.94 and ERR of 0.15. The addition of IL28B genotype information did not improve the predictive power of the 3-gene classifier. Conclusions: IL28B genotype and hepatic ISG expression are conditionally independent predictors of treatment response in CHC. There is no direct link between altered IFNλ3 expression and pre-activation of the endogenous system in the liver. Hepatic ISG expression is by far the better predictor for treatment response than IL28B genotype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: Pollen and seed dispersal in herbaceous insect-pollinated plants are often restricted, inducing strong population structure. To what extent this influences mating within and among patches is poorly understood. This study investigates the influence of population structure on pollen performance using controlled pollinations and genetic markers. METHODS: Population structure was investigated in a patchily distributed population of gynodioecious Silene vulgaris in Switzerland using polymorphic microsatellite markers. Experimental pollinations were performed on 21 hermaphrodite recipients using pollen donors at three spatial scales: (a) self-pollination; (b) within-patch cross-pollinations; and (c) between-patch cross-pollinations. Pollen performance was then compared with respect to crossing distance. KEY RESULTS: The population of S. vulgaris was characterized by a high degree of genetic sub-structure, with neighbouring plants more related to one another than to distant individuals. Inbreeding probably results from both selfing and biparental inbreeding. Pollen performance increased with distance between mates. Between-patch pollen performed significantly better than both self- and within-patch pollen donors. However, no significant difference was detected between self- and within-patch pollen donors. CONCLUSIONS: The results suggest that population structure in animal-pollinated plants is likely to influence mating patterns by favouring cross-pollinations between unrelated plants. However, the extent to which this mechanism could be effective as a pre-zygotic barrier preventing inbred mating depends on the patterns of pollinator foraging and their influence on pollen dispersal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: We previously reported the results of a phase II study for patients with newly diagnosed primary CNS lymphoma (PCNSL) treated with autologous peripheral blood stem-cell transplantation (aPBSCT) and responseadapted whole brain radiotherapy (WBRT). The purpose of this report is to update the initial results and provide long-term data regarding overall survival, prognostic factors, and the risk of treatment-related neurotoxicity.Methods: A long-term follow-up was conducted on surviving primary central nervous system lymphoma patients having been treated according to the ,,OSHO-53 study", which was initiated by the Ostdeutsche Studiengruppe Hamatologie-Onkologie. Between August 1999 and October 2004 twentythree patients with an average age of 55 and median Karnofsky performance score of 70% were enrolled and received high-dose mthotrexate (HD-MTX) on days 1 and 10. In case of at least a partial remission (PR), high-dose busulfan/ thiotepa (HD-BuTT) followed by aPBSCT was performed. Patients without response to induction or without complete remission (CR) after HD-BuTT received WBRT. All patients (n=8), who are alive in 2011, were contacted and Mini Mental State examination (MMSE) and the EORTC QLQ-C30 were performed.Results: Eight patients are still alive with a median follow-up of 116,9 months (79 - 141, range). One of them suffered from a late relapse eight and a half years after initial diagnosis of PCNSL, another one suffers from a gall bladder carcinoma. Both patients are alive, the one with the relapse of PCNSL has finished rescue therapy and is further observed, the one with gall baldder carcinoma is still under therapy. MMSE and QlQ-C30 showed impressive results in the patients, who were not irradiated. Only one of the irradiated patients is still alive with a clear neurologic deficit but acceptable quality of life.Conclusions: Long-term follow-up of our patients, who were included in the OSHO-53 study show an overall survival of 30 percent. If WBRT can be avoided no long-term neurotoxicity has been observed and the patients benefit from excellent Quality of Life. Induction chemotherapy with two cycles of HD-MTX should be intensified to improve the unsatisfactory OAS of 30 percent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential and applicability of UHPSFC-MS/MS for anti-doping screening in urine samples were tested for the first time. For this purpose, a group of 110 doping agents with diverse physicochemical properties was analyzed using two separation techniques, namely UHPLC-MS/MS and UHPSFC-MS/MS in both ESI+ and ESI- modes. The two approaches were compared in terms of selectivity, sensitivity, linearity and matrix effects. As expected, very diverse retentions and selectivities were obtained in UHPLC and UHPSFC, proving a good complementarity of these analytical strategies. In both conditions, acceptable peak shapes and MS detection capabilities were obtained within 7min analysis time, enabling the application of these two methods for screening purposes. Method sensitivity was found comparable for 46% of tested compounds, while higher sensitivity was observed for 21% of tested compounds in UHPLC-MS/MS and for 32% in UHPSFC-MS/MS. The latter demonstrated a lower susceptibility to matrix effects, which were mostly observed as signal suppression. In the case of UHPLC-MS/MS, more serious matrix effects were observed, leading typically to signal enhancement and the matrix effect was also concentration dependent, i.e., more significant matrix effects occurred at the lowest concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been introduced in diagnostic microbiology laboratories for the identification of bacterial and yeast strains isolated from clinical samples. In the present study, we prospectively compared MALDI-TOF MS to the conventional phenotypic method for the identification of routine isolates. Colonies were analyzed by MALDI-TOF MS either by direct deposition on the target plate or after a formic acid-acetonitrile extraction step if no valid result was initially obtained. Among 1,371 isolates identified by conventional methods, 1,278 (93.2%) were putatively identified to the species level by MALDI-TOF MS and 73 (5.3%) were identified to the genus level, but no reliable identification was obtained for 20 (1.5%). Among the 1,278 isolates identified to the species level by MALDI-TOF MS, 63 (4.9%) discordant results were initially identified. Most discordant results (42/63) were due to systematic database-related taxonomical differences, 14 were explained by poor discrimination of the MALDI-TOF MS spectra obtained, and 7 were due to errors in the initial conventional identification. An extraction step was required to obtain a valid MALDI-TOF MS identification for 25.6% of the 1,278 valid isolates. In conclusion, our results show that MALDI-TOF MS is a fast and reliable technique which has the potential to replace conventional phenotypic identification for most bacterial strains routinely isolated in clinical microbiology laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Emergency room reading performances have been a point of interest in recent studies comparing radiologists to other physician groups. Our objective was to evaluate and compare the reading performances of radiologists and surgeons in an emergency room setting of non-traumatic abdominal CTs. Methods and materials: A total of ten readers representing four groups participated in this study: three senior radiologists and visceral surgeons, respectively, and two junior radiologists and surgeons, respectively. Each observer blindedly evaluated a total of 150 multi-slice acute abdominal CTs. CTs were chosen representing established proportions of acute abdomen pathologies in a Level I trauma centre from 2003 to 2005. Each answer was interpretated as right or wrong regarding pathology location, diagnosis and need for operation. Gold standard was the intraoperative result, and the clinical patient follow-up for non-operated patients. Significance was assumed at a p <.05 level. Results: Senior radiologists had a mean score of 2.38 ± 1.14, junior radiologists a score of 2.34 ± 1.14, whereas senior surgeons scored 2.07 ± 1.30 and junior surgeons 1.62 ± 1.42. No significant difference was found between the two radiologist groups, but results were significantly better for senior surgeons as compared to junior surgeons and better for the two radiologist groups as compared to each of the surgeon groups (all p <.05). Conclusion: Abdominal CT reading in an acute abdomen setting should continue to rely on an evaluation by a radiologist, whether senior or junior. Satisfying reading results can be achieved by senior visceral surgeons, but junior surgeons need more experience for a good reading performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.